Proposição de um sistema integrado de gestão de transformadores. / Proposition of an integrated system for transformers management.

Vasconcellos, Vagner 13 April 2007 (has links)
O transformador de potência é o ativo mais valioso e importante de uma subestação, razão pela qual se faz necessário um acompanhamento especial para estes equipamentos. A operação de qualquer equipamento fora de suas condições nominais é sempre uma situação de risco, porém, tal risco pode ser minimizado através de estudos e análises particulares para cada equipamento.Com os transformadores de potência isso não é diferente, as normas e guias de aplicação de cargas em transformadores prevêem períodos de sobrecarga dentro de algumas condições, porém, há uma grande incerteza nesses dados já que cada transformador envelhece de forma diferente ainda que sejam idênticos de projeto e fabricação. Por essa razão se faz necessária uma análise particular de cada equipamento onde serão identificados os riscos em potencial e a partir daí determinado o grau de confiabilidade do equipamento. Com base em informações históricas dos equipamentos e algoritmos desenvolvidos com base nas normas vigentes, foi desenvolvido o Sistema Integrado de Gestão denominado SGT. Através deste sistema será possível armazenar de forma organizada as informações de todas as unidades fornecendo subsídios para uma tomada de decisão minimizando os riscos. Através do Sistema Integrado será possível estabelecer uma base única de consultas, promovendo assim a otimização destes equipamentos face a regulação do setor elétrico. / The power transformer is the most valuable and important assets of a substation, for that reason is necessary a special attendance for these equipments. The operation of any equipment out of their nominal conditions it is always a risk situation, however, such a risk can be minimized through studies and private analyses for each equipment. Power transformers are not different, the norms and guides of load application foresee overload periods under some conditions, however, and there is a great uncertainty in those data since each transformer ages in a different way although they are identical of project and production. For that reason are necessary peculiar analysis of each equipment where you/they will be identified the potential risks and since then certain the degree of reliability of the equipment. Based in historical informations of the equipments and algorithms developed in agreement with the effective norms, the Integrated System of Management was developed and denominated SGT. Through this system it will be possible to store in an organized way the information of all of the units, supplying subsidies to have a safe decision minimizing the risks. Through the Integrated System it will be possible to establish an only base of consultations, promoting the assets optimization based in the new regulation of the electric section.
2

Proposição de um sistema integrado de gestão de transformadores. / Proposition of an integrated system for transformers management.

Vagner Vasconcellos 13 April 2007 (has links)
O transformador de potência é o ativo mais valioso e importante de uma subestação, razão pela qual se faz necessário um acompanhamento especial para estes equipamentos. A operação de qualquer equipamento fora de suas condições nominais é sempre uma situação de risco, porém, tal risco pode ser minimizado através de estudos e análises particulares para cada equipamento.Com os transformadores de potência isso não é diferente, as normas e guias de aplicação de cargas em transformadores prevêem períodos de sobrecarga dentro de algumas condições, porém, há uma grande incerteza nesses dados já que cada transformador envelhece de forma diferente ainda que sejam idênticos de projeto e fabricação. Por essa razão se faz necessária uma análise particular de cada equipamento onde serão identificados os riscos em potencial e a partir daí determinado o grau de confiabilidade do equipamento. Com base em informações históricas dos equipamentos e algoritmos desenvolvidos com base nas normas vigentes, foi desenvolvido o Sistema Integrado de Gestão denominado SGT. Através deste sistema será possível armazenar de forma organizada as informações de todas as unidades fornecendo subsídios para uma tomada de decisão minimizando os riscos. Através do Sistema Integrado será possível estabelecer uma base única de consultas, promovendo assim a otimização destes equipamentos face a regulação do setor elétrico. / The power transformer is the most valuable and important assets of a substation, for that reason is necessary a special attendance for these equipments. The operation of any equipment out of their nominal conditions it is always a risk situation, however, such a risk can be minimized through studies and private analyses for each equipment. Power transformers are not different, the norms and guides of load application foresee overload periods under some conditions, however, and there is a great uncertainty in those data since each transformer ages in a different way although they are identical of project and production. For that reason are necessary peculiar analysis of each equipment where you/they will be identified the potential risks and since then certain the degree of reliability of the equipment. Based in historical informations of the equipments and algorithms developed in agreement with the effective norms, the Integrated System of Management was developed and denominated SGT. Through this system it will be possible to store in an organized way the information of all of the units, supplying subsidies to have a safe decision minimizing the risks. Through the Integrated System it will be possible to establish an only base of consultations, promoting the assets optimization based in the new regulation of the electric section.
3

OPERAÇÃO EM EMERGÊNCIA DE TRANSFORMADORES DE POTÊNCIA CONSIDERANDO RISCOS E CONTRATOS DE INTERRUPÇÃO. / EMERGENCY OPERATION OF POWER TRANSFORMERS CONSIDERING RISKS AND BREAK CONTRACTS.

SOUSA, Jéssica Cristina da Silva 03 April 2017 (has links)
Submitted by Maria Aparecida (cidazen@gmail.com) on 2017-05-09T13:49:19Z No. of bitstreams: 1 Jéssica Cristina da Sousa Silva.pdf: 3803180 bytes, checksum: 09661347277c0b6b6dadfa09a5e05299 (MD5) / Made available in DSpace on 2017-05-09T13:49:19Z (GMT). No. of bitstreams: 1 Jéssica Cristina da Sousa Silva.pdf: 3803180 bytes, checksum: 09661347277c0b6b6dadfa09a5e05299 (MD5) Previous issue date: 2017-04-03 / FAPEMA / As a result of a contingency, severe overloads may occur in a power transformer. One of the greatest concerns of energy utilities is to find a way to operate this equipment that ensures its useful life is preserved. However, there is a sharp reduction in the useful life in proportion to the level of overload and this increases the risk of failure. This paper sets out a framework for decision-making in emergency operations for power transformers, that rely on interruption contracts as decision variables and which take into account the risk of accepting any level of violation of the transformer´s operating limits. The risk of failure is calculated by measuring the useful life of the transformer and the presence of dissolved gases. The useful life is estimated by means of the Arrhenius model of thermal damage , while incipient faults can be detected by Dissolved Gas Analysis (DGA). The risk of transformer failure is estimated by examining the data cited above, on the basis of information theory concepts. It is formulated as a multi-period optimization problem with linear objectives and nonlinear constraints and restricted to the risk of accepting transformer overloads. The results are validated by means of an adapted version of the IEEE14 system, which is shown to be effective as a tool for emergency decision-making in the case studies included here. / Como consequência de uma contingência, sobrecargas severas podem ocorrer em transformadores de potência. Uma das maiores preocupações das concessionárias de energia, é operar estes equipamentos de forma que a vida útil seja preservada. No entanto esta diminui drasticamente em proporção ao nível de sobrecarga aplicado além do aumento do risco de falha. Este trabalho apresenta uma estrutura para o auxílio na tomada de decissões de operação em emergência de transformadores de potência, utilizando como variáveis de decisão contratos de interrupção conjugados com a decisão de aceitar um nível de sobrecarga baseado no risco. São usados modelos térmicos de envelhecimento do transformador para cálculo de perda de vida. Para atualização da probabilidade do risco de falha, são utilizadas informações de Análise de Gases Dissolvidos (DGA) e da perda de vida útil do transformador combinadas através de conceitos de teoria da informação. Os resultados são validados usando uma versão adaptada do sistema IEEE 14, mostrado-se eficaz como ferramenta de tomada de decisões nos estudos de caso apresentados. Contratos de interrup¸c~ao, teoria da informa¸c~ao.
4

Estimação relativa de tempo de vida de transformadores de distribuição, considerando cargas não lineares / Relative estimation of distribution transformers lifetime, considering nonlinear loads

Santos, Adriano Machado dos 29 July 2014 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2015-11-18T18:03:32Z No. of bitstreams: 2 Dissertação - Adriano Machado dos Santos - 2014.pdf: 9004500 bytes, checksum: 8843f32793f823e988a7913fedb9b4ca (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-11-19T14:25:06Z (GMT) No. of bitstreams: 2 Dissertação - Adriano Machado dos Santos - 2014.pdf: 9004500 bytes, checksum: 8843f32793f823e988a7913fedb9b4ca (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-11-19T14:25:06Z (GMT). No. of bitstreams: 2 Dissertação - Adriano Machado dos Santos - 2014.pdf: 9004500 bytes, checksum: 8843f32793f823e988a7913fedb9b4ca (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-07-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Electricity customers’ devices, connected to the secondary distribution network linked to distribution transformers belonging to the electrical energy distributor, modernize every year. These devices usually consist of components capable of processing energy and produce distortion at the load current. Thus these devices are typified as non-linear load and its effects influence the operation of the distribution transformers with implications for its lifetime. Therefore, this work presents the study of the influence of non-sinusoidal signals (distorted signals) in the lifetime of distribution transformers. In this sense equations are presented that allows to calculate transformers losses, their operating temperatures and estimate the percentage loss of life. To obtain results a computer program was developed in the numerical programming platform MATLAB based on the presented mathematical model. The developed program is supplied by data obtained from field as well as laboratory measurements. Results are also obtained by simulations. The focus of this study is the distribution system of the urban perimeter of the city Goiânia-GO. / Os aparelhos pertencentes aos consumidores de energia elétrica, ligados à rede de distribuição secundária conectados em transformadores de distribuição da distribuidora de energia elétrica, se modernizam a cada ano. Os referidos aparelhos normalmente são constituídos por componentes capazes de processar a energia e produzir distorção na corrente de alimentação. Deste modo estes aparelhos são tipificados como carga não linear e seus efeitos influenciam o funcionamento dos transformadores de distribuição com implicações no seu tempo de vida. Assim sendo, este trabalho apresenta estudo da influência de sinais não senoidais (sinais distorcidos) no tempo de vida destes transformadores. Neste sentido é apresentado equacionamento que permite calcular as perdas do transformador, suas temperaturas de operação e estimar a perda de vida percentual. Para a obtenção de resultados foi desenvolvido um programa computacional na plataforma de programação numérica MATLAB com base no modelo matemático apresentado. O programa desenvolvido é suprido por dados obtidos através de medições em campo e também de laboratório. Resultados são obtidos também por realização de simulações. O foco deste estudo é o sistema de distribuição do perímetro urbano da cidade de Goiânia-GO.