Spelling suggestions: "subject:"perfil dde detecção"" "subject:"perfil dee detecção""
1 |
Influência do perfil de sucção em obras de contenção em solos não saturados / Influences of profile suction retaining wall in unsaturated soilsRocha, Melina Freitas 22 July 2013 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-04-20T17:51:20Z
No. of bitstreams: 3
Dissertação - Melina Freitas Rocha - 2013 - parte 01.pdf: 18877116 bytes, checksum: db6e237169520b45aaf7353c708c8366 (MD5)
Dissertação - Melina Freitas Rocha - 2013 - parte 02.pdf: 8252606 bytes, checksum: c0d1163233c3716f97b6b48d0006dada (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-04-20T17:52:46Z (GMT) No. of bitstreams: 3
Dissertação - Melina Freitas Rocha - 2013 - parte 01.pdf: 18877116 bytes, checksum: db6e237169520b45aaf7353c708c8366 (MD5)
Dissertação - Melina Freitas Rocha - 2013 - parte 02.pdf: 8252606 bytes, checksum: c0d1163233c3716f97b6b48d0006dada (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-04-20T17:52:47Z (GMT). No. of bitstreams: 3
Dissertação - Melina Freitas Rocha - 2013 - parte 01.pdf: 18877116 bytes, checksum: db6e237169520b45aaf7353c708c8366 (MD5)
Dissertação - Melina Freitas Rocha - 2013 - parte 02.pdf: 8252606 bytes, checksum: c0d1163233c3716f97b6b48d0006dada (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2013-07-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The need for the use of structures retaining wall have been increasingly used in engineering
works. The valuation of soil use has led to wide-ranging exploration of the subsoil, resulting
in large excavations that change the equilibrium state of the soil. The performance and design
of retaining wall require a good understanding of the stress state of the soil, soil-structure
interaction and varying the saturation of soil during construction and useful life. The useful
life of retaining wall must ensure stability, functionality and durability. The analysis of soilstructure
interaction becomes important by the fact that the same structure subjected to the
same external load, presents support reactions that vary with the particular conditions of the
mass of soil in which it lies. Therefore the study of soil-atmosphere interaction is an essential
factor for unsaturated soils. In order to evaluate the influence of suction on structural design
in balance were simulated real conditions of rainfall in three different soils for three
excavations (3, 6 e 9 m) and inciciais different conditions N.A. It was observed that the
behavior of the suction profile is inwardly related to the parameters as well as saturated and
unsaturated soil each, with the intensity and duration of precipitation. Through the theory of
earth pressure Rankine for saturated soils, the formulation was developed to calculate the
active and passive earth pressure into account the unsaturated soil for three different behaviors
of suction, i.e., constant suction over the depth matric suction decrease linearly with depth and
suction profile mixed (ie, the part is kept constant and decrease linearly with depth). After
determination of the active and passive earth pressure was established equilibrium limit
retaining wall and give the sheet length for safety factors of 1,0 and 1,5. It was noticed that
there is reduction in the active earth pressure and increased passive earth pressure for all
conditions in suction profile. Due to suction, there is an increased horizontal depth tension
zone that contributes to the reduction in the horizontal efforts on the structures retaining wall ,
then a reduction in the sheet length. Otherwise the specific weight natural varies with the
suction and that is a factor that can increase efforts, particularly for rainfall with relative
intensity close to 1 (q/ksat) and saturated soils with high permeability, where suction is small
and has constant distribuiton in the soil profile. / A necessidade do uso das estruturas de contenção tem sido cada vez mais frequente em obras
de engenharia. A valorização do uso do solo tem levado a exploração ampla do subsolo,
implicando em grandes escavações que alteram o estado de equilíbrio do solo. O desempenho
e dimensionamento da contenção exigem um bom entendimento do estado de tensões do solo,
da interação solo-estrutura e da variação da saturação do solo durante a construção e vida útil
da contenção. A vida útil de uma obra deve garantir estabilidade, funcionalidade e
durabilidade. A análise da interação solo-estrutura torna-se importante pelo fato de que a
mesma estrutura, submetida à mesma carga externa, apresenta reações de apoio que variam
com as condições particulares do maciço de solo em que ela se encontra. Portanto o estudo da
interação solo-atmosfera é um dos fatores essenciais para os solos não saturados. Com intuito
de avaliar a influência da sucção no dimensionamente de uma estrutura de contenção em
balanço, foram simulados condições reais de precipitações em três solos distintos para três
profundidades de escavações (3, 6 e 9 m) e para várias condições inciciais de N.A. E
observou-se que o comportamento do perfil de sucção está intimamente relacionado com os
parâmetros saturados bem como os não saturados de cada solo, com a intensidade e duração
da precipitação. Através da teoria do empuxo de terra de Rankine, para os solos saturados
foram desenvolvidas as formulação para cálculo dos empuxos ativos e passivo levando em
consideração a não saturação do solo, para três comportamentos diferentes da sucção, isto é;
sucção constante ao longo da profundidade, sucção variando linearmente com a profundidade
e perfil de sucção misto (i.e., parte é mantido constante e parte varia linearmente com a
profundidade). Após a determinação dos empuxos ativo e passivo foi estabelecido o equilíbrio
limite da contenção e determinado o comprimento da ficha para dos fatores de segurança de
1,0 e 1,5. Percebeu-se que há redução do empuxo ativo e um acréscimo do empuxo passivo
para todas as condições de perfil de sucção. Devido a sucção, há um aumento da profundidade
da tensão horizontal nula que foi um dos parâmetros que contribui para a redução dos esforços
horizontais na contenção, logo uma redução no comprimento da ficha. Por outro lado o peso
específico natural varia com a sucção e esse é um fator que pode aumentar os esforços,
principalmente para chuvas com intensidade relativa próxima de 1 (q/ksat) e solos com
permeabilidade saturada alta, onde a sucção é pequena e tem-se distribuição constante no
perfil do solo.
|
Page generated in 0.0391 seconds