• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 13
  • 11
  • 3
  • 1
  • Tagged with
  • 54
  • 54
  • 12
  • 11
  • 11
  • 11
  • 11
  • 11
  • 10
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Využití fluxačních přísad pro úpravu vlastností asfaltových pojiv / Use of fluxing additives to modify the properties of asphalt binders

Šefránková, Radka January 2020 (has links)
The subject of the thesis is to describe the effect of fluxing additives on the behaviour of asphalt binders. Emphasis will be placed on changes in rheological properties of asphalt binders at intermediate temperatures, stability during aging and influence of fluxing agents on their low-temperature properties. Theoretical part will deal with the principle of asphalt binders aging and it will summarize knowledge about fluxing additives. Further, empirical and functional tests will be described in order to evaluate asphalt binders. In the practical part, all laboratory tests will be evaluated and the effects of two different fluxing additives will be compared.
52

Návrh transformátoru s regulací fáze pro laboratorní výuku / Design Laboratory Phase Shifting Transformer

Korejčík, Michal January 2012 (has links)
This thesis deals with a power flow control in the electric power system. An overview of FACTS devices is introduced; their basic characteristics as well as examples of their application are discussed. A significant part of this thesis investigates phase shifting transformers (PST´s), which seem to be suitable for implementation in the transmission system of the Czech Republic. The PST´s are useful devices that control active power flows on cross-border lines and regulate unwanted and unexpected power flows. Basic types and characteristics of the PST´s are discussed. In chapter 7 is designed laboratory task that should validate the regulatory capabilities of the transformer PST. Designs of models of individual parts of this laboratory task are presented. In the last part of this thesis the regulation effect of the PST is validated in the GLF/AES program.
53

Hodnocení vlastností pojiv typu PMB obsahujících pojivo z R-materiálu / Evaluation of properties of PMB containing binder from RAP

Měšťanová, Petra Unknown Date (has links)
Subject of this diploma thesis is to describe the effect of adding different amount of aged binder recovered from RAP on the change of properties of polymer modified bitumen. The RAP containing unmodified bitumen and the RAP where we can expect bitumen modification are used to recover binder. The binder obtained from RAP is dosed into the virgin binder in amount of 15 %, 30 % and 50 %. The methods of recycling of flexible pavements, extraction and regeneration of asphalt binders, rejuvenating of their properties and methods of empirical and functional laboratory tests are described in the theoretical part. The practical part deals with evaluating and comparison of the results mixed binders properties.
54

Techniques to assess volume status and haemodynamic stability in patients on haemodialysis

Mathavakkannan, Suresh January 2010 (has links)
Volume overload is a common feature in patients on haemodialysis (HD). This contributes significantly to the cardiovascular disease burden seen in these patients. Clinical assessments of the volume state are often inaccurate. Techniques such as interdialytic blood pressure, relative blood volume monitoring, bioimpedance are available to improve clinical effectives. However all these techniques exhibit significant shortcomings in their accuracy, reliability and applicability at the bed side. We evaluated the usefulness of a dual compartment monitoring technique using Continuous Segmental Bioimpedance Spectroscopy (CSBIS) and Relative Blood Volume (RBV) as a tool to assess hydration status and determine dry weight. We also sought to evaluate the role of Atrial Natriuretic Peptide (ANP) and B-type Natriuretic Peptide (BNP) as a volume marker in dialysis patients. The Retrospective analysis of a historical cohort (n = 376, 55 Diabetic) showed a significant reduction in post-dialysis weights in the first three months of dialysis (72.5 to 70kg, p<0.027) with a non-significant increase in weight between months 6-12. The use of anti-hypertensive agents reduced insignificantly in the first 3 months, increased marginally between months 3-6 and significantly increased over the subsequent 6 months. The residual urea clearance (KRU) fell and dialysis times increased. The cohort was very different to that dialysing at Tassin and showed a dissociation between weight reduction and BP control. This may relate to occult volume overload. CSBIS-RBV monitoring in 9 patients with pulse ultrafiltration (pulse UF) showed distinct reproducible patterns relating to extra cellular fluid (ECF) and RBV rebound. An empirical Refill Ratio was then used to define the patterns of change and this was related to the state of their hydration. A value closer to unity was consistent with the attainment of best achievable target weight. The refill ratio fell significantly between the first (earlier) and third (last) rebound phase (1.97 ± 0.92 vs 1.32 ± 0.2). CSBIS monitoring was then carried out in 31 subjects, whilst varying dialysate composition, temperature and patient posture to analyse the effects of these changes on the ECF trace and to ascertain whether any of these interventions can trigger a change in the slope of the ECF trace distinct to that caused by UF. Only, isovolemic HD caused a change in both RBV and ECF in some patients that was explained by volume re-distribution due to gravitational shifts, poor vascular reactivity, sodium gradient between plasma and dialysate and the use of vasodilating antihypertensive agents. This has not been described previously. These will need to be explored further. The study did demonstrate a significant lack of comparability of absolute values of RECF between dialysis sessions even in the same patient. This too has not been described previously. This is likely to be due to subtle changes in fluid distribution between compartments. Therefore a relative changes must be studied. This sensitivity to subtle changes may increase the usefulness of the technique for ECF tracking through dialysis. The potential of dual compartment monitoring to track volume changes in real time was further explored in 29 patients of whom 21 achieved weight reductions and were able to be restudied. The Refill Ratio decreased significantly in the 21 patients who had their dry weights reduced by 0.95 ± 1.13 kg (1.41 ± 0.25 vs 1.25 ± 0.31). Blood pressure changes did not reach statistical significance. The technique was then used to examine differences in vascular refill between a 36oC and isothermic dialysis session in 20 stable prevalent patients. Pulse UF was carried out in both these sessions. There were no significant differences in Refill Ratios, energy removed and blood pressure response between the two sessions. The core temperature (CT) of these patients was close to 36oC and administering isothermic HD did not confer any additional benefit. Mean BNP levels in 12 patients during isovolemic HD and HD with UF did not relate to volume changes. ANP concentrations fell during a dialysis session in 11 patients from a mean 249 ± 143 pg/ml (mean ± SD) at the start of dialysis to 77 ± 65 pg/ml at the end of the session (p<0.001). During isolated UF levels did not change but fell in the ensuing sham phase indicating a time lag between volume loss and decreased generation. (136±99 pg/ml to 101±77.2 pg/ml; p<0.02) In a subsequent study ANP concentrations were measured throughout dialysis and in the post-HD period for 2 hours. A rebound in ANP concentration was observed occurring at around 90 min post-HD. The degree of this rebound may reflect the prevailing fluid state and merit further study. We have shown the utility of dual compartment monitoring with CSBIS-RBV technique and its potential in assessing volume changes in real time in haemodialysis patients. We have also shown the potential of ANP as an independent marker of volume status in the same setting. Both these techniques merit further study.

Page generated in 0.2343 seconds