• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 14
  • 10
  • 10
  • 10
  • 8
  • 8
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação biomecânica de prótese parcial fixa com cantilever sobre implantes em região posterior da mandíbula: estudo comparativo in vitro / Biomechanical evaluation of implant-supported cantilever fixed partial denture in posterior region of the mandible: in vitro comparative study

Peixoto, Raniel Fernandes 28 June 2017 (has links)
Nos casos de perda óssea vertical severa, principalmente em áreas posteriores da mandíbula, uma alternativa às cirurgias de enxerto ósseo, pouco empregada e estudada, é a utilização de prótese parcial fixa (PPF) com cantilever distal. Pensando no material de infraestrutura que garanta resistência adequada para suportar as forças mastigatórias em longo prazo, aliado ao desenvolvimento da zircônia (Zr) e da tecnologia CAD/CAM, o objetivo deste estudo foi avaliar o desajuste vertical, perda de torque, resistência à fratura do cantilever e distribuição de tensões em PPFs parafusadas sobre implantes do tipo cone morse, confeccionadas em diferentes materiais de infraestrutura (Co-Cr [Fundição Convencional] e Co-Cr e Zr [CAD/CAM]) e posicionadas na área correspondente à região posterior da mandíbula. Foram confeccionadas 40 PPFs com cantilever distal e distribuídas em 5 grupos (n=8), de acordo com o material da infraestrutura: 1 Co-Cr (Fundição convencional soldagem a laser); 2 Co-Cr (Fundição convencional soldagem TIG); 3 Co-Cr (Fundição convencional monobloco); 4 Co-Cr (CAD/CAM) e 5 Zr (CAD/CAM). A análise do desajuste vertical foi realizada em 4 momentos distintos, com auxílio de estereomicroscopia (aumento de 50×) e usando o método de Sheffiled: T0 Infraestrutura no modelo mestre; T1 Infraestrutura no modelo de poliuretano, antes da aplicação do revestimento cerâmico; T2 PPF após aplicação do revestimento cerâmico e antes da ciclagem termomecânica e T3 PPF após da ciclagem termomecânica. A avaliação do afrouxamento de parafusos foi realizada antes (T2) e após (T3) a ciclagem termomecânica e foi obtida com o auxílio de um torquímetro digital com precisão de 0,1 N.cm. Para a realização da ciclagem termomecânica as PPFs foram posicionadas na máquina de ensaio e uma carga de 120 N foi aplicada sobre elas, buscando simular 14 meses de utilização (1.200.000 ciclos). A resistência máxima à fratura do cantilever foi determinada por meio do ensaio de flexão e, para isso, uma carga perpendicular ao longo eixo da peça protética foi aplicada, com uma velocidade de aproximação de 0,5 mm/min. Uma nova PPF para cada grupo foi confeccionada para ser utilizada na avaliação da distribuição de tensões quando elas foram submetidas a carregamento puntiforme no cantilever e oclusal distribuído (150 N), por meio de análise fotoelástica. Em geral, PPFs com infraestruturas em monobloco (G3) apresentaram maiores desajustes verticais, especialmente no elemento solto da segunda e terceira condição experimental e foram associados com maior concentração de tensões, tanto no carregamento puntiforme (360,07 kPa) quanto oclusal distruído (302,46 kPa). Por outro lado, infraestruturas obtidas por meio do sistema CAD/CAM mostraram os menores desajustes verticais, se assemelhando estatisticamente (p>0,05), em vários momentos, com infraestruturas soldadas e melhores distribuições de tensões, atingindo valores inferiores a 280 kPa no carregamento puntiforme e a 200 kPa no oclusal distribuído. A moldagem de transferência (T0 &rarr; T1) e a ciclagem termomecânica (T2 &rarr; T3) pouco influenciaram no desajuste vertical dos grupos. Já o processo de aplicação do revestimento cerâmico (T1 &rarr; T2) e o seu efeito cumulativo com a ciclagem termomecânica (T1 &rarr; &rarr; T3) foram responsáveis por alterações consideráveis no desajuste vertical dos grupos, sobretudo naqueles fundidos convencionalmente (G1, G2 e G3). A ciclagem termomecânica teve um efeito considerável no percentual de perda de torque intragrupo (pMolar=0,039; pPré-molar=0,044), embora comparações entre os diferentes grupos não tenham demonstrado significância estatística (pMolar=0,116; pPré-molar=0,334). PPFs com infraestrutura metálica (>410,83±72,26 N) apresentaram resistência à fratura consideravelmente maior (p<0,05) do que a zirconia (277,47±39,10 N) e os primeiros sinais de fratura do revestimento cerâmico foram observados em torno de 900 N. Dentro das limitações deste estudo, PPFs com infraestruturas confeccionadas por meio do sistema CAD/CAM foram associadas com melhor adaptação cervical e distribuição de tensões, embora a secção das infraestruturas seguida de soldagem pode também ser uma alternativa viável, com base na proximidade dos valores de desajustes verticais e distribuição de tensão. Adicionalmente, PPFs com infraestruturas em zircônia podem ser usadas com certo grau de segurança, tendo em vista a boa adaptação marginal e distribuição de tensões, bem como altos valores de resistência à fratura constatados. / In cases of severe vertical bone loss, especially in posterior region of the mandible, an alternative to bone graft surgery, little used and studied, is the use of implant-supported cantilever fixed partial denture (FPD). Thinking about the framework material that ensures adequate strength to resist the masticatory loads in long term, together with the development of zirconia (Zr) and of CAD/CAM technology, the aim of this study is to evaluate the vertical misfit, torque loss and fracture resistance of cantilever and stress distribution in FPDs screwretained on Morse taper implants, fabricated with different framework materials (Co-Cr [Conventional Casting] and Co-Cr and Zr [CAD/CAM]) and positioned on the posterior region of the mandible. Forty FPDs with distal cantilever were fabricated and distributed into 5 groups (n=8), according to framework material: 1 Co-Cr (Conventional casting laser welding); 2 Co-Cr (Conventional casting TIG welding); 3 Co-Cr (Conventional casting one-piece); 4 Co-Cr (CAD/CAM) and 5 Zr (CAD/CAM). Analysis of vertical misfit was performed in 4 different moments, using stereomicroscopy (50× magnification) and the Sheffield method: T0 Framework on master model; T1 Framework on polyurethane model, before the ceramic veneering application; T2 FPD after application of the ceramic veneering and before the thermomechanical cycling and T3 FPD after thermomechanical cycling. Evaluation of screw loosening was performed before (T2) and after (T3) thermomechanical cycling and was obtained by a digital torque wrench with an accuracy of 0.1 N.cm. To perform the thermomechanical cycling, FPDs were positioned in the testing machine, and a 120 N load was applied on them, seeking to simulate 14 months of use (1,200,000 cycles). Fracture maximum resistance of the cantilever was determined by the flexural test and, therefore, a perpendicular force on the cantilever was applied at a crosshead speed of 0.5 mm/min. A new FDP for each group was fabricated to be used in the evaluation of the stress distribution, when they were submitted to punctiform on the cantilever and oclusal distributed loads (150 N), by the photoelastic analysis. In general, FPDs with one-piece frameworks (G3) presented higher vertical misfits, especially in the element not tightened of the second and third experimental conditions, and were associated with higher stress concentration in both the punctiform (360.07 kPa) and oclusal distributed (302.46 kPa) loads. On the other hand, the frameworks obtained by the CAD/CAM system showed the smaller vertical misfits, being statistically similar (p>0.05) to welded frameworks at various times, and better stress distributions, reaching values less than 280 kPa in the punctiform load and 200 kPa in the occlusal distributed load. Transfer impression (T0 &rarr; T1) and thermomechanical cycling (T2 &rarr; T3) had little effect on vertical misfit of the groups. The application process of the ceramic veneering (T1 &rarr; T2) and its cumulative effect with thermomechanical cycling (T1 &rarr;T3) were responsible for considerable changes in vertical misfit of the group, especially in those conventionally cast (G1, G2 and G3). A thermomechanical cycling had considerable effect in the percentage of intragroup torque loss (pMolar=0.039; pPré-molar=0.044), although comparisons between the different groups did not show statistical significance (pMolar=0.116; pPrémolar= 0.334). FPDs with metal frameworks (>410.83±72.26 N) showed considerably higher fracture resistance (p<0.05) than zirconia (277.47±39.10 N) and the first signs of fracture of the ceramic veneering were observed around 900 N. Within the limitations of this study, FPDs with frameworks fabricated using the CAD/CAM system were associated with better cervical adaptation and stress distribution, although the section of the frameworks followed by welding may also be a viable alternative, based on the proximity of the values of vertical misfits and stress distribution. Additionally, FPDs with zirconia frameworks can be used with some degree of security, considering the good marginal adaptation and stress distribution, as well as high values of fracture resistance verified.
12

Avaliação biomecânica de prótese parcial fixa com cantilever sobre implantes em região posterior da mandíbula: estudo comparativo in vitro / Biomechanical evaluation of implant-supported cantilever fixed partial denture in posterior region of the mandible: in vitro comparative study

Raniel Fernandes Peixoto 28 June 2017 (has links)
Nos casos de perda óssea vertical severa, principalmente em áreas posteriores da mandíbula, uma alternativa às cirurgias de enxerto ósseo, pouco empregada e estudada, é a utilização de prótese parcial fixa (PPF) com cantilever distal. Pensando no material de infraestrutura que garanta resistência adequada para suportar as forças mastigatórias em longo prazo, aliado ao desenvolvimento da zircônia (Zr) e da tecnologia CAD/CAM, o objetivo deste estudo foi avaliar o desajuste vertical, perda de torque, resistência à fratura do cantilever e distribuição de tensões em PPFs parafusadas sobre implantes do tipo cone morse, confeccionadas em diferentes materiais de infraestrutura (Co-Cr [Fundição Convencional] e Co-Cr e Zr [CAD/CAM]) e posicionadas na área correspondente à região posterior da mandíbula. Foram confeccionadas 40 PPFs com cantilever distal e distribuídas em 5 grupos (n=8), de acordo com o material da infraestrutura: 1 Co-Cr (Fundição convencional soldagem a laser); 2 Co-Cr (Fundição convencional soldagem TIG); 3 Co-Cr (Fundição convencional monobloco); 4 Co-Cr (CAD/CAM) e 5 Zr (CAD/CAM). A análise do desajuste vertical foi realizada em 4 momentos distintos, com auxílio de estereomicroscopia (aumento de 50×) e usando o método de Sheffiled: T0 Infraestrutura no modelo mestre; T1 Infraestrutura no modelo de poliuretano, antes da aplicação do revestimento cerâmico; T2 PPF após aplicação do revestimento cerâmico e antes da ciclagem termomecânica e T3 PPF após da ciclagem termomecânica. A avaliação do afrouxamento de parafusos foi realizada antes (T2) e após (T3) a ciclagem termomecânica e foi obtida com o auxílio de um torquímetro digital com precisão de 0,1 N.cm. Para a realização da ciclagem termomecânica as PPFs foram posicionadas na máquina de ensaio e uma carga de 120 N foi aplicada sobre elas, buscando simular 14 meses de utilização (1.200.000 ciclos). A resistência máxima à fratura do cantilever foi determinada por meio do ensaio de flexão e, para isso, uma carga perpendicular ao longo eixo da peça protética foi aplicada, com uma velocidade de aproximação de 0,5 mm/min. Uma nova PPF para cada grupo foi confeccionada para ser utilizada na avaliação da distribuição de tensões quando elas foram submetidas a carregamento puntiforme no cantilever e oclusal distribuído (150 N), por meio de análise fotoelástica. Em geral, PPFs com infraestruturas em monobloco (G3) apresentaram maiores desajustes verticais, especialmente no elemento solto da segunda e terceira condição experimental e foram associados com maior concentração de tensões, tanto no carregamento puntiforme (360,07 kPa) quanto oclusal distruído (302,46 kPa). Por outro lado, infraestruturas obtidas por meio do sistema CAD/CAM mostraram os menores desajustes verticais, se assemelhando estatisticamente (p>0,05), em vários momentos, com infraestruturas soldadas e melhores distribuições de tensões, atingindo valores inferiores a 280 kPa no carregamento puntiforme e a 200 kPa no oclusal distribuído. A moldagem de transferência (T0 &rarr; T1) e a ciclagem termomecânica (T2 &rarr; T3) pouco influenciaram no desajuste vertical dos grupos. Já o processo de aplicação do revestimento cerâmico (T1 &rarr; T2) e o seu efeito cumulativo com a ciclagem termomecânica (T1 &rarr; &rarr; T3) foram responsáveis por alterações consideráveis no desajuste vertical dos grupos, sobretudo naqueles fundidos convencionalmente (G1, G2 e G3). A ciclagem termomecânica teve um efeito considerável no percentual de perda de torque intragrupo (pMolar=0,039; pPré-molar=0,044), embora comparações entre os diferentes grupos não tenham demonstrado significância estatística (pMolar=0,116; pPré-molar=0,334). PPFs com infraestrutura metálica (>410,83±72,26 N) apresentaram resistência à fratura consideravelmente maior (p<0,05) do que a zirconia (277,47±39,10 N) e os primeiros sinais de fratura do revestimento cerâmico foram observados em torno de 900 N. Dentro das limitações deste estudo, PPFs com infraestruturas confeccionadas por meio do sistema CAD/CAM foram associadas com melhor adaptação cervical e distribuição de tensões, embora a secção das infraestruturas seguida de soldagem pode também ser uma alternativa viável, com base na proximidade dos valores de desajustes verticais e distribuição de tensão. Adicionalmente, PPFs com infraestruturas em zircônia podem ser usadas com certo grau de segurança, tendo em vista a boa adaptação marginal e distribuição de tensões, bem como altos valores de resistência à fratura constatados. / In cases of severe vertical bone loss, especially in posterior region of the mandible, an alternative to bone graft surgery, little used and studied, is the use of implant-supported cantilever fixed partial denture (FPD). Thinking about the framework material that ensures adequate strength to resist the masticatory loads in long term, together with the development of zirconia (Zr) and of CAD/CAM technology, the aim of this study is to evaluate the vertical misfit, torque loss and fracture resistance of cantilever and stress distribution in FPDs screwretained on Morse taper implants, fabricated with different framework materials (Co-Cr [Conventional Casting] and Co-Cr and Zr [CAD/CAM]) and positioned on the posterior region of the mandible. Forty FPDs with distal cantilever were fabricated and distributed into 5 groups (n=8), according to framework material: 1 Co-Cr (Conventional casting laser welding); 2 Co-Cr (Conventional casting TIG welding); 3 Co-Cr (Conventional casting one-piece); 4 Co-Cr (CAD/CAM) and 5 Zr (CAD/CAM). Analysis of vertical misfit was performed in 4 different moments, using stereomicroscopy (50× magnification) and the Sheffield method: T0 Framework on master model; T1 Framework on polyurethane model, before the ceramic veneering application; T2 FPD after application of the ceramic veneering and before the thermomechanical cycling and T3 FPD after thermomechanical cycling. Evaluation of screw loosening was performed before (T2) and after (T3) thermomechanical cycling and was obtained by a digital torque wrench with an accuracy of 0.1 N.cm. To perform the thermomechanical cycling, FPDs were positioned in the testing machine, and a 120 N load was applied on them, seeking to simulate 14 months of use (1,200,000 cycles). Fracture maximum resistance of the cantilever was determined by the flexural test and, therefore, a perpendicular force on the cantilever was applied at a crosshead speed of 0.5 mm/min. A new FDP for each group was fabricated to be used in the evaluation of the stress distribution, when they were submitted to punctiform on the cantilever and oclusal distributed loads (150 N), by the photoelastic analysis. In general, FPDs with one-piece frameworks (G3) presented higher vertical misfits, especially in the element not tightened of the second and third experimental conditions, and were associated with higher stress concentration in both the punctiform (360.07 kPa) and oclusal distributed (302.46 kPa) loads. On the other hand, the frameworks obtained by the CAD/CAM system showed the smaller vertical misfits, being statistically similar (p>0.05) to welded frameworks at various times, and better stress distributions, reaching values less than 280 kPa in the punctiform load and 200 kPa in the occlusal distributed load. Transfer impression (T0 &rarr; T1) and thermomechanical cycling (T2 &rarr; T3) had little effect on vertical misfit of the groups. The application process of the ceramic veneering (T1 &rarr; T2) and its cumulative effect with thermomechanical cycling (T1 &rarr;T3) were responsible for considerable changes in vertical misfit of the group, especially in those conventionally cast (G1, G2 and G3). A thermomechanical cycling had considerable effect in the percentage of intragroup torque loss (pMolar=0.039; pPré-molar=0.044), although comparisons between the different groups did not show statistical significance (pMolar=0.116; pPrémolar= 0.334). FPDs with metal frameworks (>410.83±72.26 N) showed considerably higher fracture resistance (p<0.05) than zirconia (277.47±39.10 N) and the first signs of fracture of the ceramic veneering were observed around 900 N. Within the limitations of this study, FPDs with frameworks fabricated using the CAD/CAM system were associated with better cervical adaptation and stress distribution, although the section of the frameworks followed by welding may also be a viable alternative, based on the proximity of the values of vertical misfits and stress distribution. Additionally, FPDs with zirconia frameworks can be used with some degree of security, considering the good marginal adaptation and stress distribution, as well as high values of fracture resistance verified.
13

Análise da distribuição de tensões em implantes suporte de prótese total fixa em função do número e inclinação dos implantes, tipo de liga, presença ou ausência de cantilever e forma da secção transversal da infraestrutura / Analysis of stress transfer in fixed complete prosthese supporting implants varying the number of implants, cast metal alloy, presence or absence of cantilever, angulation of distal implants and superstructure cross-sectional shape

Pinto, Humberto Oliveira 07 June 2011 (has links)
A fotoelasticidade é um método analítico usado para avaliar e calcular as tensões existentes em qualquer ponto da superfície de um material. É uma ferramenta para análise de tensões bidimensionais, usa luz monocromática polarizada e modelos de resina. O objetivo do presente estudo foi comparar as tensões induzidas na interface osso-implante em diferentes planejamentos de próteses fixas totais implantossuportadas protocolo de Branemark. As variáveis nos modelos foram: número de implantes, tipo de liga, presença ou ausência de cantilever, inclinação dos implantes distais e secção transversal da infraestrutura. Foram confeccionados 32 modelos fotoelásticos e foram realizadas análises qualitativa e quantitativa das tensões induzidas. Os modelos sofreram carga estática no valor de 50 N na porção central e distal da barra. Os implantes central e distal foram analisados sob as cargas central e distal individualmente. Os pilares receberam torque de 20 N.cm e os parafusos protéticos de fixação da barra receberam 10 N.cm. Antes de qualquer avaliação, foi certificado que os modelos fotoelásticos encontravam-se livres de tensões residuais. A tensão (MPa) acumulada nos implantes distais sob carga distal foi aproximadamente 7 vezes maior que nas outras situações de carga. Além disso, 69% de toda tensão acumulada no sistema se manifestou no implante distal sob carga distal. Houve uma clara vantagem para as estruturas fundidas em cobalto-cromo em relação às fundidas em titânio concernente à distribuição de tensões. A análise da secção transversal demonstrou que na comparação entre viga convencional e viga I, houve distribuição aleatória de resultados. Também ficou evidente que o número maior de implantes favorece a uma melhor distribuição de tensões. Já quando foram comparadas barras de protocolo apresentando ou não cantilever, as infraestruturas sem cantilever apresentaram um resultado marcadamente superior àquelas com cantilever. Finalmente, as infraestruturas com implantes distais retos apresentaram uma melhor distribuição de tensões. Com base nos resultados obtidos, pode-se concluir que o método de fotoelasticidade é um método laboratorial apropriado para análise de tensões; próteses tipo protocolo de Branemark com 5 implantes provêm uma melhor condição de distribuição de tensões do que com 4 implantes; a secção transversal da supraestrutura metálica e o tipo de liga utilizado na fundição não apresentaram relação direta com o padrão de distribuição de tensões nos implantes; a distribuição de tensões nos implantes dentários em uma prótese tipo protocolo é mais eficiente com implantes distais retos e sem extensão em cantilever. / Photoelastic analysis is a method used to evaluate and calculate stresses at a material surface. It is a tool for bidimensional stresses analysis. Polarized monochromatic light and resin models for stresses evaluation were used. The purpose of this study was to compare the induced stresses in the bone-implant interface using different implant supporting complete fixed prostheses Branemark protocol. The variables studied in the models were: the number of implants, cast metal alloy, presence or absence of cantilever, angulation of distal implants and superstructure cross-sectional shape. It were prepared thirty-two photoelastic models and perceived quantitative and qualitative analysis of the induced stresses. 50 Newtons static load was exerted on the central and the distal part of the superstructure. Central and distal implants were analyzed under central and distal loads individually. The abutments were tightened with a 20 N.cm torque and the prosthetic screws with a 10 N.cm torque. Before the evaluations took place, it was checked if the implants presented residual stresses. Stresses accumulated in the distal implants under distal load were nine times greater than in the other loading situations and received approximately 69% of all stresses scattered in the whole system. There was a clear advantage for cobalto-chromium cast superstructures over titanium ones about stress transfer. The analysis of the cross-sectional superstructure shape evinced that when comparing conventional beam with i-beam there was an aleatoric results distribution. It was also evident that a superstructure with more implants collaborates to a better stresses distribution. Comparing Branemark protocol bars presenting or not cantilever extension, those with no cantilever presented remarked superior results than those with cantilever. Finally, superstructures with straight implants had a better stress transfer than those with angulated ones. Based upon the obtained results, it was concluded that the photoelastic method is a laboratorial evaluation method suitable for stress transfer analysis. Five implants complete fixed prostheses provide a better stress than those with four implants. Cross-sectional metal superstructure shape and the type of cast alloy demonstrate no direct correlation about the stress transfer pattern over the implants. The stress distribution over dental implants in a Branemark procotol prosthese is more efficient with straight distal implants and a bar with no cantilever extension.
14

Análise da distribuição de tensões em implantes suporte de prótese total fixa em função do número e inclinação dos implantes, tipo de liga, presença ou ausência de cantilever e forma da secção transversal da infraestrutura / Analysis of stress transfer in fixed complete prosthese supporting implants varying the number of implants, cast metal alloy, presence or absence of cantilever, angulation of distal implants and superstructure cross-sectional shape

Humberto Oliveira Pinto 07 June 2011 (has links)
A fotoelasticidade é um método analítico usado para avaliar e calcular as tensões existentes em qualquer ponto da superfície de um material. É uma ferramenta para análise de tensões bidimensionais, usa luz monocromática polarizada e modelos de resina. O objetivo do presente estudo foi comparar as tensões induzidas na interface osso-implante em diferentes planejamentos de próteses fixas totais implantossuportadas protocolo de Branemark. As variáveis nos modelos foram: número de implantes, tipo de liga, presença ou ausência de cantilever, inclinação dos implantes distais e secção transversal da infraestrutura. Foram confeccionados 32 modelos fotoelásticos e foram realizadas análises qualitativa e quantitativa das tensões induzidas. Os modelos sofreram carga estática no valor de 50 N na porção central e distal da barra. Os implantes central e distal foram analisados sob as cargas central e distal individualmente. Os pilares receberam torque de 20 N.cm e os parafusos protéticos de fixação da barra receberam 10 N.cm. Antes de qualquer avaliação, foi certificado que os modelos fotoelásticos encontravam-se livres de tensões residuais. A tensão (MPa) acumulada nos implantes distais sob carga distal foi aproximadamente 7 vezes maior que nas outras situações de carga. Além disso, 69% de toda tensão acumulada no sistema se manifestou no implante distal sob carga distal. Houve uma clara vantagem para as estruturas fundidas em cobalto-cromo em relação às fundidas em titânio concernente à distribuição de tensões. A análise da secção transversal demonstrou que na comparação entre viga convencional e viga I, houve distribuição aleatória de resultados. Também ficou evidente que o número maior de implantes favorece a uma melhor distribuição de tensões. Já quando foram comparadas barras de protocolo apresentando ou não cantilever, as infraestruturas sem cantilever apresentaram um resultado marcadamente superior àquelas com cantilever. Finalmente, as infraestruturas com implantes distais retos apresentaram uma melhor distribuição de tensões. Com base nos resultados obtidos, pode-se concluir que o método de fotoelasticidade é um método laboratorial apropriado para análise de tensões; próteses tipo protocolo de Branemark com 5 implantes provêm uma melhor condição de distribuição de tensões do que com 4 implantes; a secção transversal da supraestrutura metálica e o tipo de liga utilizado na fundição não apresentaram relação direta com o padrão de distribuição de tensões nos implantes; a distribuição de tensões nos implantes dentários em uma prótese tipo protocolo é mais eficiente com implantes distais retos e sem extensão em cantilever. / Photoelastic analysis is a method used to evaluate and calculate stresses at a material surface. It is a tool for bidimensional stresses analysis. Polarized monochromatic light and resin models for stresses evaluation were used. The purpose of this study was to compare the induced stresses in the bone-implant interface using different implant supporting complete fixed prostheses Branemark protocol. The variables studied in the models were: the number of implants, cast metal alloy, presence or absence of cantilever, angulation of distal implants and superstructure cross-sectional shape. It were prepared thirty-two photoelastic models and perceived quantitative and qualitative analysis of the induced stresses. 50 Newtons static load was exerted on the central and the distal part of the superstructure. Central and distal implants were analyzed under central and distal loads individually. The abutments were tightened with a 20 N.cm torque and the prosthetic screws with a 10 N.cm torque. Before the evaluations took place, it was checked if the implants presented residual stresses. Stresses accumulated in the distal implants under distal load were nine times greater than in the other loading situations and received approximately 69% of all stresses scattered in the whole system. There was a clear advantage for cobalto-chromium cast superstructures over titanium ones about stress transfer. The analysis of the cross-sectional superstructure shape evinced that when comparing conventional beam with i-beam there was an aleatoric results distribution. It was also evident that a superstructure with more implants collaborates to a better stresses distribution. Comparing Branemark protocol bars presenting or not cantilever extension, those with no cantilever presented remarked superior results than those with cantilever. Finally, superstructures with straight implants had a better stress transfer than those with angulated ones. Based upon the obtained results, it was concluded that the photoelastic method is a laboratorial evaluation method suitable for stress transfer analysis. Five implants complete fixed prostheses provide a better stress than those with four implants. Cross-sectional metal superstructure shape and the type of cast alloy demonstrate no direct correlation about the stress transfer pattern over the implants. The stress distribution over dental implants in a Branemark procotol prosthese is more efficient with straight distal implants and a bar with no cantilever extension.

Page generated in 0.0702 seconds