• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 186
  • 131
  • 131
  • 131
  • 131
  • 131
  • 129
  • 21
  • 16
  • 7
  • 2
  • Tagged with
  • 369
  • 369
  • 117
  • 109
  • 107
  • 75
  • 68
  • 43
  • 28
  • 26
  • 26
  • 21
  • 15
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Prototype fan beam optical computed tomography scanner for three-dimensional radiotherapy dose verification

Rudko, David 12 April 2010 (has links)
A prototype rapid, high precision fan beam optical computed tomography (OptCT) scanner for three-dimensional polymer gel dosimetry of complex radiotherapy protocols has been developed. This study documents the design. construction and characterization of the system, as well as preliminary reconstructed optical attenuation images and dosimetric verification experiments. The principal goal in scanner design and implementation was to satisfy the Radiotherapy Accuracy and Precision (RTAP) criteria consisting of a spatial resolution of 1 x 1 x 1 mm3, an imaging time of 60 minutes, a dose accuracy within 3% and a precision within 1%. The scanner, which employs a sixty degree fan beam of 543 nm laser light to scan irradiated polymer gel samples up to 19 cm in cross-sectional diameter. has several defining attributes. Data acquisition for a single slice through a dosimeter is achieved in two minutes, using one signal acquisition per CT projection angle over a total of 360 projections. The effects of scatter and refraction of visible light are minimized by using the unique radial design of the matching medium tank, the concentric arrangement of a prototype, computer numerical control (CNC)-machined collimator and five Hamamatsu photodiode detector arrays for light detection. The novel tertiary collimation eliminates scattered light by 13% and improves reconstructed image contrast-to-noise ratio. Other characteristics of the scanner include: a laser power output variation of only 0.7%:, signal-to-noise ratio (SNR.) for calibration projections of up to 294:1, SNR for transmission projections through an irradiated polymer gel dosimeter of up to 161:1, a large absorbance dynamic range extending from 0.1 to 1.7 absorbance units and a spatial resolution of 0.25 mm2 in the axial plane of the scan¬ning geometry and 0.8 mm along the longitudinal z-axis of the scan plane. Images of optical attenuation coefficients and concomitant dose maps extracted from irradi¬ated, normoxic N--isopropylacylamide (NIPAM) polymer gels were used to investigate the potential of the system for dosimetric verification. Three different NIPAM gel irradiation experiments were performed and the resultant OptCT dose distributions were compared to the Eclipse® (Varian Medical Systems. Palo Alto. CA.) treatment planning system model. While the fan beam OptCT scanner provides promising ini¬tial images of reconstructed optical attenuation coefficients, its dosimetric accuracy compared to Eclipse - nominally 7% in low dose gradient regions and 5% on the field edges - constitutes the most significant area for future refinement.
312

What constitutes a clinic-like radiotherapy photon beam /

Kalach, Nina, January 1900 (has links)
Thesis (M. Sc.)--Carleton University, 2001. / Includes bibliographical references (p. 64-71). Also available in electronic format on the Internet.
313

Inverse treatment planning by simulated annealing optimization of a dose-volume objective function

Sham, Edwin O. H. January 2001 (has links)
No description available.
314

Development of a portal imager and of tools for radiation treatment verification

Wang, Hui, 1964- January 1996 (has links)
No description available.
315

Photoneutrons and induced activity from medical linear accelerators

Wang, Yi Zhen, 1965- January 2004 (has links)
No description available.
316

Validation of Monte Carlo techniques for 3D-CRT of lung cancer patients and comparative evaluation of treatment plans

Dai, Jinxian January 2005 (has links)
No description available.
317

Physical parameters of narrow photon beams in radiosurgery

Sixel, Katharina E. (Katharina Elisabeth) January 1990 (has links)
No description available.
318

Dynamic wedge dosimetry on a dual energy linear accelerator

Barry, Devin P. January 1996 (has links)
No description available.
319

Characteristic angle-beta concept in electron arc therapy

Robar, Vlado January 1996 (has links)
No description available.
320

Assessment of the Effect of Cancer and its Treatment on PET Scan F-18 Tracer Distribution in Pre- and Post-treatment and its Relation to Myocardial Tissue Uptake

Earla, Janaki Ram Prasad 26 August 2005 (has links)
No description available.

Page generated in 0.0872 seconds