• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise do efeito da retangularidade dos pilares nos critérios normativos de dimensionamento à punção em lajes lisas de concreto armado / Analysis of the effect of rectangularity rate of the columns in normative criteria for sizing punching in reinforced concrete flat slabs

PAIVA, Odilson da Silva de 22 October 2013 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T13:05:15Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEfeitoRetangularidade.pdf: 2760909 bytes, checksum: f7553da9a0e039bc587df51a11724a63 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-20T16:05:13Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEfeitoRetangularidade.pdf: 2760909 bytes, checksum: f7553da9a0e039bc587df51a11724a63 (MD5) / Made available in DSpace on 2017-03-20T16:05:13Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEfeitoRetangularidade.pdf: 2760909 bytes, checksum: f7553da9a0e039bc587df51a11724a63 (MD5) Previous issue date: 2013-10-22 / O sistema com lajes lisas que não dependem de vigamento apresenta sua resistência limitada pela resistência à punção, visto que a região da ligação laje-pilar é critica devido às cargas concentradas em torno dos pilares. A geometria dos pilares é um dos fatores de influência na distribuição de tensões da região de ligação laje-pilar afetando por sua vez no dimensionamento à punção de lajes lisas. Neste estudo foi realizada uma profunda coleta de dados que visa reunir em um único trabalho a maior quantidade possível de lajes englobando os maiores nomes no estudo de punção, nacionais e internacionais, apresentando um total de 131 lajes. Foi feita uma comparação entre os principais códigos normativos usados atualmente, Eurocode 2 (2004), NBR 6118 (2007), ACI 318 (2008) e CEB-FIP (2010). Os resultados experimentais foram confrontados com os obtidos teoricamente levando em consideração os efeitos do índice de retângularidade em lajes lisas de concreto armado sem armaduras de cisalhamento verificando a adequação, confiabilidade de cada recomendação, analisando as particularidades das regras e diretrizes de cada critério normativo. / The system with flat slabs that do not depend on framework of beam has limited resistance by the resistance to punching shear, since the region of the slab-column is critical due to concentrated loads around the columns. The geometry of the columns is one of the factors influencing the distribution of stresses in the region of slab-column connection affecting turn in sizing the punching shear in the flat slabs. In this study we performed a thorough data collection that aims to collect into a single job the greatest possible amount of slabs covering the biggest names in the study of national and international punch, featuring a total of 131 slabs. A comparison was made between the main normative codes currently used Eurocode 2 (2004), NBR 6118 (2007), ACI 318 (2008) and CEB-FIP (2010). The experimental results were compared with those obtained theoretically taking into account the effects of retangularidade rate index in flat slabs of reinforced concrete, without punching shear reinforcement checking the adequacy, trustworthiness of each recommendation, analyzing the particularities of the rules and guidelines of each normative criterion.
2

Análise experimental de lajes lisas unidirecionais de concreto armado com pilares retangulares ao puncionamento / Experimental unidirectional smooth flagstone analysis of armed concrete with rectangular pillars to the puncionamento

DAMASCENO, Lins Sandro Resque 20 December 2007 (has links)
Made available in DSpace on 2011-03-23T21:19:39Z (GMT). No. of bitstreams: 0 / Item created via OAI harvest from source: http://www.bdtd.ufpa.br/tde_oai/oai2.php on 2011-03-23T21:19:39Z (GMT). Item's OAI Record identifier: oai:bdtd.ufpa.br:294 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / They were analyzed 8(eight) experimentally one-way flat slabs of reinforced concrete, without punching shear reinforcement, for that the reinforcement rate in secondary direction and the largest dimension of the pillars (cmax). The flat slab were dimensions of (1.800 x 1.800 x 110) mm, same flexing reinforcement, to smallest dimension of the columns (cmin) constant and equal to 85 mm, resistance to the compression of the concrete around 40 MPa and submitted to the load in the center (symmetrical punching shear), that it simulates an internal column of a pavement. The application of the load was accomplished in passages of columns linked moliticamente to the flat slab with height 150 mm, with retangularidade rate (r = cmax/cmin) varying from 1 to 7. The objective was to evaluate the influence of the retangularidade rate, that contemplated in the increase of the control perimeter in this case, in the behavior of the slabs under flexing, and possibly a more ductile failure. The objective went to also analyze the dear rupture loads starting from the recommendations of six national and international project codes, comparing with the obtained experimental results and evaluating the estimates to the punching shear, once, when the dimensions of the pillars are substantially different can happen the polarization of tensions and the resistance earnings doesn't happen in way directly proportional to the increase of the perimeter of the columns. After analyzing the influences of the retangularidade rate of the columns and the contributions that the reinforcement rate in secondary the last loads of the flats slabs and in the failure modes, it was observed that the experimental results indicated that those varied besides elevating the resistance of the connection can supply certain ductility to the failure of the slabs. It was observed that the rate of growth of the resistances obtained in the rehearsals decreases with increments in the control perimeter. Of the observations regarding the comparison among the values of resistances of the flats slabs, it was verified that the increase of the load of experimental rupture didn't come in a lineal way, indicating that the rate of growth of the load decreases with the increase of the perimeter of the column or of the rate cmax/cmin when stays constant to smallest dimension of the column (cmin). / Foram analisadas experimentalmente 8 (oito) lajes lisas de concreto armado sem armadura de cisalhamento, variando-se a taxa de armadura de flexão secundária e a maior dimensão dos pilares (cmax). As lajes de dimensões (1.800 x 1.800 x 110) mm, mesma armadura flexão principal, menor dimensão dos pilares (cmin) constante e igual a 85 mm, resistência à compressão do concreto em torno de 40 MPa foram submetidas à carga no centro (punção simétrica), que simula um pilar interno de um pavimento. A aplicação da carga foi realizada em trechos de pilares moliticamente ligados às lajes com 150 mm de altura, com índices de retangularidade (r = cmax/cmin) variando de 1 a 7. O objetivo foi avaliar a influência do índice de retangularidade, que neste caso refletiu no aumento do perímetro de controle, no comportamento das lajes sob flexão, e possivelmente uma ruptura mais dúctil. O objetivo foi também analisar as cargas de ruptura estimadas a partir das recomendações de seis códigos de projeto nacionais e internacionais, comparando com os resultados experimentais obtidos e avaliando as estimativas ao puncionamento, uma vez que, quando as dimensões dos pilares são substancialmente diferentes pode ocorrer a polarização de tensões e o ganho de resistência não ocorre de forma diretamente proporcional ao aumento do perímetro dos pilares. Após analisar as influências do índice de retangularidade dos pilares e as contribuições da taxa de armadura de flexão secundária nas cargas últimas das lajes e nos modos de ruptura, observou-se que os resultados experimentais indicaram que essas variáveis além de elevar a resistência da ligação podem fornecer certa ductilidade à ruptura da laje. Observou-se também que a taxa de crescimento das resistências obtidas nos ensaios diminui com incrementos no perímetro de controle. Das observações referentes à comparação entre os valores de resistências das lajes, obtidas nos ensaios, verificou-se que o aumento da carga de ruptura experimental não se apresentou de forma linear, indicando que a taxa de crescimento da carga diminui com o aumento do perímetro do pilar ou da relação cmax/cmin quando se mantém constante a menor dimensão do pilar (Cmin).
3

Punção em lajes cogumelo : estudo da retangularidade dos pilares

MOURO, Valéria Conceição 31 August 2006 (has links)
Made available in DSpace on 2014-07-29T15:03:37Z (GMT). No. of bitstreams: 1 Dissertacao Christine Garrido Marquez.pdf: 3277601 bytes, checksum: e27c6b29c8e0951b47d16d9bbfeb2287 (MD5) Previous issue date: 2006-08-31 / Eight reinforced concrete square flat slabs of reinforced concrete were tested. Slabs were 130mm thick with an 1800 mm side and were submitted to central loading, and the objective was to investigate the influence of column rectangularity coefficient. Column cross section dimensions (cmáx/cmín) varyied between 1 and 4, with a constant perimeter equal to 1000mm. Results presented and analysed include ultimate loads and failure types, modes of rupture, vertical displacements, cracking and deformations of steel and concrete. Comparisons with codes, norms and results of literature results are also presented. The results indicate that as the rectangularity coefficient increases, punching shear resistance decreases for constant perimeter column flat slabs. Suggesting that punching shear has to be considered specially in regions close to column extremity, where there is a larger concentration of shear forces. A proposal for an inclusion of the retangularity parameter (cmáx/cmín) in expressions for calculation punching shear resistance of ACI (2002), CEB-FIP (1991), EC2 (2001) and NBR-6118 (2003) codes is presented. / São analisadas experimentalmente 8 (oito) lajes cogumelo de concreto armado quadradas com 1800 mm de lado e 130 mm de espessura, submetidas a carregamento central, com o objetivo de investigar a influência do índice de retanguralidade do pilar, sendo que a relação entre as dimensões da seção transversal do pilar (cmáx/cmín) variou entre 1 e 4, com perímetro mantido constante e igual a 1000 mm. São apresentados e analisados os resultados das cargas últimas, modos de ruptura, deslocamentos verticais, fissuração e deformações do aço e concreto. São apresentadas comparações dos resultados experimentais com códigos, normas de projeto e resultados da literatura. Os resultados indicam que à medida que aumenta o índice de retangularidade, a resistência à punção diminui, para lajes que possuem pilares com o perímetro constante. Sugerindo que o combate à punção pode ser mais efetivo em regiões próximas das extremidades dos pilares, onde há maior concentração de forças cortantes. É apresentada uma proposta de inclusão do parâmetro cmáx/cmín nas expressões de cálculo da resistência à punção do ACI (2002), CEB-FIP (1991), EC2 (2001) e NBR-6118 (2003).

Page generated in 0.0639 seconds