• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 16
  • 16
  • 13
  • 11
  • 10
  • 9
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da interface entre pino pré-fabricado e dentina radicular por microscopia óptica e eletrônica de varredura com baixo e alto vácuo / Interfaces analysis between fiber post and root dentin using optic microscopy and SEM with low and high vaccum

Tavares, Andrea Urbano 01 June 2007 (has links)
Os objetivos deste estudo foram avaliar a adaptação das interfaces de união entre dentina radicular, cimento resinoso e pino pré-fabricado de fibra de vidro (presença ou não de fendas), variando: o método de avaliação (MEV, baixo vácuo, óptico), região da dentina radicular observando os terços apical(a), médio(m) e cervical(c) e o tratamento de superfície do pino (com ou sem silano). 20 dentes unirradiculares humanos foram tratados endodonticamente e após 72h houve a remoção da porção coronária e preparo dos condutos para receber o pino pré-fabricado FRC Postek Plus® (1.4 ? 14mm), condicionados com ácido fosfórico (37%-15s), aplicado sistema adesivo Excite DSC® e fotoativado(600mW/cm2?40s). Metade dos pinos (n=10) recebeu uma camada de silano. As amostras foram separados em grupo 1 (G1- sem silano) e grupo 2 (G2- com silano) Os pinos foram cimentados com Variolink II®, fotoativado(40s-600mW/cm2), após 72h, as raízes foram seccionadas (12 fatias-1mm), embutidas (RAAQ), polidas (#220- 4000), desidratadas, confeccionadas réplicas em resina epóxica e analisadas em microscópio óptico (MO), microscopia eletrônica de varredura (MEV) (réplicas e raizes), baixo vácuo (BV) e alto vácuo(AV). A fenda nas interfaces foi quantificada (?m) e os dados analisados (teste Aspin-Welch e t-Student), por porção (a,m,c), interface pino-cimento (pc) e cimento-dentina radicular (cd) (p<0,05). Para a análise em MO, os resultados de área aderida foram: G1 pc: am=c; G2 pc: a=m<c e cd: a=m=c. Para a análise em MEV, utilizando réplicas, G1/G2 pc e cd: a=m<c. Com relação às fendas , G1 pc e cd: a=m=c , G2 pc: a=m=c e cd: a>m=c. Para BV, G1 pc e cd: a<m=c, G2 pc: a=m<c, cd: a=m=c. Para MEV AV, G1 pc: a<m<c, cd:a=m<c e G2. pc: a=m<c, cd: a=m=c. Em todas as análises e em ambos os grupos, pc>cd. Concluindose que as informações obtidas com as diversas técnicas de microscopia se complementam, a interação pc promove maior área aderida que cd, existe diferença entre as porções da raiz e não existe diferença para o tratamento de superfície do pino. / The aim of this study was to evaluate the interface between resin cement and fiber post FRC Postek Plus® inside the root canal, using light transmission optical microscopy (MO) and Scanning electron microscope (SEM) with replica´s technique quantitative evaluation and samples analysed with high(HV) and low (LV) vaccum, considering different root region: apical (a), middle(m) and coronal (c) and the post surface treatment with or without silanization. 20 extracted human single rooted were endodontically- treated. They were decoronated and their root canals prepared to receive fiber post FRC Postek Plus® (#1-14mm). All canal were phosphoric acid etched (37%- 15s), washed, dried with paper points. Then, the Ecite DSC adhesive system was applied and light cured (600 mW/cm2?40s). The surface of 10 fiber posts were treated with silane (Monobond S). The samples were divided in two groups: G1(w/o silane) and G2(with silane). All posts were cimented with Variolink II light cured for 60s After 72h stored (distilled water ? 370C), roots were serially sliced perpendicular to the bond interface into twelve 1.0mm-thick slabs, which were divided in apical, middle and coronal root region.The samples were embeeded in acrylic resin, polished (#220-4000), dehidrated and observed at optic microscope. After that, replicas with epoxy resin were obtained. Samples and replicas were gold sputter-coated to be observed at SEM. Gap formations were quantified (?m). Results were analyzed with Aspin-Welch and t- Student´s test, considering the interface post-cement (pc), cement-dentin (cd) and the root region (c.m,a)(p<0.05). In MO, the adhesion area results were: G1 pc: am=c; G2 pc: a=m<c e cd: a=m=c. In SEM with replicas: G1/G2 pc and cd: a=m<c.Considering the gap size: G1 pc and cd: a=m=c , G2 pc: a=m=c and cd: a>m=c. To LV G1 pc and cd: a<m=c, G2 pc: a=m<c, cd: a=m=c. To SEM HV, G1 pc: a<m<c, cd:a=m<c and G2. pc: a=m<c, cd: a=m=c. To both groups and in total analysis pc>cd. So, results obtained with all the micrscopy technique add informantion among them, the interation pc has better adhesion area than cd, there is difference among the root region and no difference to the fiber post surface treatment.
2

Estudo da interface entre pino pré-fabricado e dentina radicular por microscopia óptica e eletrônica de varredura com baixo e alto vácuo / Interfaces analysis between fiber post and root dentin using optic microscopy and SEM with low and high vaccum

Andrea Urbano Tavares 01 June 2007 (has links)
Os objetivos deste estudo foram avaliar a adaptação das interfaces de união entre dentina radicular, cimento resinoso e pino pré-fabricado de fibra de vidro (presença ou não de fendas), variando: o método de avaliação (MEV, baixo vácuo, óptico), região da dentina radicular observando os terços apical(a), médio(m) e cervical(c) e o tratamento de superfície do pino (com ou sem silano). 20 dentes unirradiculares humanos foram tratados endodonticamente e após 72h houve a remoção da porção coronária e preparo dos condutos para receber o pino pré-fabricado FRC Postek Plus® (1.4 ? 14mm), condicionados com ácido fosfórico (37%-15s), aplicado sistema adesivo Excite DSC® e fotoativado(600mW/cm2?40s). Metade dos pinos (n=10) recebeu uma camada de silano. As amostras foram separados em grupo 1 (G1- sem silano) e grupo 2 (G2- com silano) Os pinos foram cimentados com Variolink II®, fotoativado(40s-600mW/cm2), após 72h, as raízes foram seccionadas (12 fatias-1mm), embutidas (RAAQ), polidas (#220- 4000), desidratadas, confeccionadas réplicas em resina epóxica e analisadas em microscópio óptico (MO), microscopia eletrônica de varredura (MEV) (réplicas e raizes), baixo vácuo (BV) e alto vácuo(AV). A fenda nas interfaces foi quantificada (?m) e os dados analisados (teste Aspin-Welch e t-Student), por porção (a,m,c), interface pino-cimento (pc) e cimento-dentina radicular (cd) (p<0,05). Para a análise em MO, os resultados de área aderida foram: G1 pc: am=c; G2 pc: a=m<c e cd: a=m=c. Para a análise em MEV, utilizando réplicas, G1/G2 pc e cd: a=m<c. Com relação às fendas , G1 pc e cd: a=m=c , G2 pc: a=m=c e cd: a>m=c. Para BV, G1 pc e cd: a<m=c, G2 pc: a=m<c, cd: a=m=c. Para MEV AV, G1 pc: a<m<c, cd:a=m<c e G2. pc: a=m<c, cd: a=m=c. Em todas as análises e em ambos os grupos, pc>cd. Concluindose que as informações obtidas com as diversas técnicas de microscopia se complementam, a interação pc promove maior área aderida que cd, existe diferença entre as porções da raiz e não existe diferença para o tratamento de superfície do pino. / The aim of this study was to evaluate the interface between resin cement and fiber post FRC Postek Plus® inside the root canal, using light transmission optical microscopy (MO) and Scanning electron microscope (SEM) with replica´s technique quantitative evaluation and samples analysed with high(HV) and low (LV) vaccum, considering different root region: apical (a), middle(m) and coronal (c) and the post surface treatment with or without silanization. 20 extracted human single rooted were endodontically- treated. They were decoronated and their root canals prepared to receive fiber post FRC Postek Plus® (#1-14mm). All canal were phosphoric acid etched (37%- 15s), washed, dried with paper points. Then, the Ecite DSC adhesive system was applied and light cured (600 mW/cm2?40s). The surface of 10 fiber posts were treated with silane (Monobond S). The samples were divided in two groups: G1(w/o silane) and G2(with silane). All posts were cimented with Variolink II light cured for 60s After 72h stored (distilled water ? 370C), roots were serially sliced perpendicular to the bond interface into twelve 1.0mm-thick slabs, which were divided in apical, middle and coronal root region.The samples were embeeded in acrylic resin, polished (#220-4000), dehidrated and observed at optic microscope. After that, replicas with epoxy resin were obtained. Samples and replicas were gold sputter-coated to be observed at SEM. Gap formations were quantified (?m). Results were analyzed with Aspin-Welch and t- Student´s test, considering the interface post-cement (pc), cement-dentin (cd) and the root region (c.m,a)(p<0.05). In MO, the adhesion area results were: G1 pc: am=c; G2 pc: a=m<c e cd: a=m=c. In SEM with replicas: G1/G2 pc and cd: a=m<c.Considering the gap size: G1 pc and cd: a=m=c , G2 pc: a=m=c and cd: a>m=c. To LV G1 pc and cd: a<m=c, G2 pc: a=m<c, cd: a=m=c. To SEM HV, G1 pc: a<m<c, cd:a=m<c and G2. pc: a=m<c, cd: a=m=c. To both groups and in total analysis pc>cd. So, results obtained with all the micrscopy technique add informantion among them, the interation pc has better adhesion area than cd, there is difference among the root region and no difference to the fiber post surface treatment.
3

Avaliação da microdureza de cimentos resinosos dual utilizados na cimentação de pinos de fibra de vidro submetidos a diferentes condições de polimerização e armazenamento em água / Evaluation of the microhardness of dual cure resin cements in the luting of fiberglass posts under different conditions of cure and water storage

Ramos, Marcelo Barbosa 29 April 2009 (has links)
Este trabalho teve como objetivo avaliar a microdureza de dois cimentos resinosos de polimerização dual (RelyX U100®, 3M-ESPE e Panavia F 2.0®, Kuraray), empregados na cimentação de pinos de fibra de vidro (Fibrekor-Jeneric® Pentron) variando o modo de polimerização em químico, fotoativação imediata ou tardia após 5min através de luz halógena, avaliando também o efeito do armazenamento em água deionizada por três meses. Este trabalho testou as seguintes hipóteses nulas: não há diferença nos valores de microdureza entre os cimentos, modo de polimerização, efeito do armazenamento e entre os terços radiculares. Sessenta raízes de incisivos bovinos, com 16mm de comprimento cérvico-apical, tiveram seus condutos obturados e, posteriormente, preparados para cimentação do pino intracanal. Os espécimes foram divididos em 6 grupos (n = 10), cada um subdividido em 2 subgrupos com 5 espécimes para cada cimento. Os pinos foram cimentados de acordo com o protocolo descrito por cada fabricante. No grupo A1, os espécimes foram mantidos em ambiente à prova de luz para que ocorresse apenas a polimerização química. No grupo B1, os espécimes foram cimentados e submetidos à fotoativação imediata, e, no grupo C1, realizou-se a fotoativação após 5 minutos. As raízes foram seccionadas longitudinalmente, para que a linha de cimento pudesse ser exposta e os testes de microdureza realizados. Após 7 dias, as médias de microdureza (± desvio padrão) foram obtidas, para os terços cervical, médio e apical, respectivamente: A1 (Panavia) - 41,25 ±3,38 / 38,17±1,74 / 35,63±1,73; A1 (U100) - 59,43±4,32 / 52,14±3,00 / 50,27±4,13; B1 (Panavia) - 75,29±4,84 / 60,36±6,76 / 48,97±3,33; B1 (U100) 62,41±6,83 / 53,99±4,74 / 49,04±2,20; C1 (Panavia) - 70,22±93 / 61,00±4,48 / 56,46±7,51; C1 (U100) - 62,40±6,66 / 53,69±2,00 / 51,54±2,18. Para os grupos armazenados em água, os valores médios de microdureza (± desvio padrão) obtidos nos 3 grupos, químico (grupo A2), fotoativado imediatamente (grupo B2) e fotoativado tardiamente (grupo C2), nos terços cervical, médio e apical, respectivamente, foram: A2 (Panavia) - 37,17±1,38 / 35,01±0,74 / 34,10±2,37; A2 (U100) - 52,39±2,00 / 52,13±3,01 / 51,06±1,48; B2 (Panavia) - 63,01±2,17 / 55,94±2,10 / 48,55±1,62; B2 (U100) - 58,81±2,34 / 55,19±1,42 / 55,71±3,17; C2 (Panavia) - 56,99±1,21 / 51,29±1,81 / 48,29±3,00; C2 (U100) - 59,02±2,04 / 57,05±2,04 / 54,95±1,05. Os resultados foram submetidos ao teste ANOVA a 4 critérios (cimento, modo de polimerização, armazenamento e terços), que detectou diferenças estatísticas entre os grupos, e o teste de Tukey foi aplicado para comparações individuais. Os resultados mostraram que: a fotoativação com luz halógena promoveu um aumento significativo nos valores de microdureza para o cimento Panavia; o armaz namento em água por três meses reduziu os valores de microdureza para a maioria dos grupos, sendo que o cimento o U100 apresentou menor variação de dureza quando comparado ao Panavia; os terços que receberam maior intensidade de luz halógena tiveram maior aumento de microdureza para ambos os cimentos, especialmente para o cimento Panavia. Conclui-se, portanto, que as hipóteses de nulidade propostas foram rejeitadas. / The objective of this study was to evaluate the microhardness of two dual cure resin cements (RelyX - U100®, 3M-ESPE and Panavia F 2.0®, Kuraray), used for fiberglass posts (Fibrekor ® - Jeneric Pentron) cementation. Chemical cure and a halogen immediate and late light cure source were compared, and the effect of storage in deionized water for three months was also evaluated. This study tested the following null hypotheses: there is no difference between the microhardness values for each dual cure resin cement, cure source type, storage time, or root thirds. Sixty bovine incisor roots 16mm long had their roots restored and then prepared for post cementation. The specimens were divided into 6 groups (n = 10), and each group was subdivided into 2 subgroups with 5 specimens for each cement. The posts were cemented according to manufacturers instructions. In group A1, the specimens were kept in a light-proof environment to ensure only a chemical cure. In group B1, the specimens were restored and subjected to immediate light curing, and in group C1, light curing was performed after 5 minutes. The roots were longitudinally sectioned to expose the cement line and perform microhardness tests. After 7 days, the average microhardness (± standard deviation) values were obtained for the cervical, medium and apical thirds, respectively: A1 (Panavia ) - 41,25±3,38 / 38,17±1,74 / 35,63±1,73; A1 (U100) - 59,43±4,32 / 52,14±3,00 / 50,27±4,13; B1 (Panavia) - 75,29±4,84 / 60,36±6,76 / 48,97±3,33; B1 (U100) - 62,41±6,83 / 53,99±4,74 / 49,04±2,20; C1 (Panavia) - 70,22±1,93 / 61,00±4,48 / 56,46±7,51; C1 (U100) - 62,40±6,66 / 53,69±2,00 / 51,54±2,18. For the 3 groups stored in deionized water (chemical [group A2], immediate light curing [group B2] and late light curing [group C2]), the average microhardness values (± standard deviation) obtained for the cervical, medium and apical thirds, respectively were: A2 (Panavia) - 37,17±1,38 / 35,01±0,74 / 34,10±2,37; A2 (U100) - 52,39±2,00 / 52,13±3,01 / 51,06±1,48; B2 (Panavia) - 63,01±2,17 / 55,94±2,10 / 48,55±1,62; B2 (U100) - 58,81±2,34 / 55,19±1,42 / 55,71±3,17; C2 (Panavia) - 56,99±1,21 / 51,29±1,81 / 48,29±3,00; C2 (U100) - 59,02±2,04 / 57,05±2,04 / 54,95±1,05. ANOVA testing was used to detect statistical differences among the 4 criteria (cements, cure mode, storage and thirds) and the Tukey test was used for individual comparisons. The results showed that the halogen light cure promoted a significant increase in microhardness values for Panavia cement; storage in water for three months reduced microhardness values for most of the groups, although U100 resulted in less microhardness variation compared to Panavia; the thirds that received a higher intensity of halogen light had a higher increase in the average values of microhardness for both cements, especially for Panavia. Therefore, the null hypotheses proposed in this work were rejected.
4

Evidências científicas na utilização de pinos de fibra de vidro e núcleos metálicos fundidos / Scientific evidences on the use of glass fiber posts and cast metal posts

Moraes, Aline Pinheiro de 07 November 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-05-18T17:43:22Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Evidências científicas na utilização de pinos de fibra de vidro e nucleos metálicos fundidos.pdf: 3303685 bytes, checksum: 0b79b726661436d448f803f2526b28df (MD5) / Made available in DSpace on 2017-05-18T17:43:22Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Evidências científicas na utilização de pinos de fibra de vidro e nucleos metálicos fundidos.pdf: 3303685 bytes, checksum: 0b79b726661436d448f803f2526b28df (MD5) Previous issue date: 2014-11-07 / Sem bolsa / Tradicionalmente, os metais têm sido utilizados como retentores intrarradiculares como meio para fornecer ancoragem às restaurações devido às suas propriedades físicas adequadas e possibilidade de serem fundidos ou usinados em formas precisas. No entanto, a crescente demanda por estética tem levado ao desenvolvimento de retentores mais estéticos sendo especialmente os de fibra de vidro considerados uma alternativa aos núcleos metálicos fundidos (NMFs) na restauração de dentes tratados endodonticamente. Considerando ambos os tipos de retentores intrarradiculares, este estudo foi dividido em quatro partes. Na primeira, foi realizada uma revisão narrativa de literatura sobre os conceitos atuais na utilização de pinos de fibra de vidro. De maneira geral, concluiu-se com que o uso de pinos de fibra de vidro é uma importante opção clínica, mas deve-se tomar especial atenção às dificuldades de se obter uma boa adesão ao longo do canal radicular. Na segunda parte, foi realizada uma revisão sistemática na qual se avaliou se a utilização de silano seria benéfica para a resistência de união de pinos de fibra de vidro. Esta revisão mostrou que embora haja pouca evidência na literatura, a silanização pode melhorar a retenção de pinos de fibra de vidro quando tratamentos físicos/químicos seletivos são aplicados ao pino antes da silanização. Na terceira parte, foi realizado um estudo in vitro com o objetivo de comparar como os operadores com diferentes níveis de expertise e as técnicas de moldagem intracanal (direta ou indireta) influenciariam nas características de superfície das moldagens e qualidade dos núcleos metálicos fundidos. Os resultados mostraram que ambos os operadores e técnicas de moldagem resultaram em núcleos metálicos fundidos clinicamente aceitáveis de acordo com os padrões internacionais. No ensaio clínico randomizado foi avaliada a qualidade dos núcleos metálicos fundidos em relação a sua adaptação dependendo da posição do dente no arco e a técnica de moldagem realizada. Os resultados mostraram NMFs mais curtos quando a técnica indireta foi utilizada. No entanto, independentemente da técnica todos os pinos fundidos ficaram mais curtos do que o que foi moldado, embora clinicamente aceitáveis. A técnica indireta mostrou-se mais rápida do que a técnica direta, sendo este achado especialmente importante quando planejados casos de moldagens múltiplas e/ou espaço interoclusal reduzido. Desta forma, podemos concluir que os dados do estudo in vitro corroboram com os dados do ECR, uma vez que independentemente da técnica de moldagem, dos operadores e da posição do dente no arco, todos os núcleos metálicos fundidos foram mais curtos do que o que foi moldado, embora clinicamente aceitáveis. / Traditionally, metals have been used to fabricate dental posts because of their suitable physical properties and possibility of being cast or machined into precise shapes. However, in recent decades, the increasing demand for aesthetics has led to the development of glass fiber posts. Glass fiber posts are considered an alternative to cast metal posts to restore endodontically treated teeth. Considering both types of intracanal posts, this study was divided into four parts. In the first, a narrative literature review of current concepts in the use of glass fiber posts was performed. In general, it may be said that the use of fiber posts is an important clinical option in Dentistry, but clinicians should be aware of the difficulties in achieving good adhesion within the root canal. In the second part, a systematic review evaluated if the use of silane would be beneficial to the bond strength of glass fiber posts. This review showed that although there is little evidence in the literature, silanization might improve the retention of glass fiber posts luted into root canals provided that selective physical/chemical surface treatments are applied to the post before silanization. In the third part, an in vitro study compared how operators (experienced or not) and intracanal impression techniques (direct or indirect) influenced the surface characteristics of the impressions and the quality of cast metal posts. Results showed that both operators and techniques resulted in clinically acceptable posts according to international standards. The fourth part of this study evaluated the accuracy of cast metal posts depending on the tooth position and impression technique performed on a randomised controlled trial. Results showed that cast metal post were shorter than their respectvive impressions for all variables tested, but resulted in clinically acceptable metal posts. However, the direct technique was more time-consuming than the indirect technique, which is especially important in cases of multiple teeth involved and/or reduced interarch space. Thus, it may be concluded that data from the in vitro study corroborated with the RCT, as irrespective of the impression technique, operator level of expertise or the position of the tooth in the arch all cast metal posts were shorter, but clinically acceptable.
5

Avaliação da microdureza de cimentos resinosos dual utilizados na cimentação de pinos de fibra de vidro submetidos a diferentes condições de polimerização e armazenamento em água / Evaluation of the microhardness of dual cure resin cements in the luting of fiberglass posts under different conditions of cure and water storage

Marcelo Barbosa Ramos 29 April 2009 (has links)
Este trabalho teve como objetivo avaliar a microdureza de dois cimentos resinosos de polimerização dual (RelyX U100®, 3M-ESPE e Panavia F 2.0®, Kuraray), empregados na cimentação de pinos de fibra de vidro (Fibrekor-Jeneric® Pentron) variando o modo de polimerização em químico, fotoativação imediata ou tardia após 5min através de luz halógena, avaliando também o efeito do armazenamento em água deionizada por três meses. Este trabalho testou as seguintes hipóteses nulas: não há diferença nos valores de microdureza entre os cimentos, modo de polimerização, efeito do armazenamento e entre os terços radiculares. Sessenta raízes de incisivos bovinos, com 16mm de comprimento cérvico-apical, tiveram seus condutos obturados e, posteriormente, preparados para cimentação do pino intracanal. Os espécimes foram divididos em 6 grupos (n = 10), cada um subdividido em 2 subgrupos com 5 espécimes para cada cimento. Os pinos foram cimentados de acordo com o protocolo descrito por cada fabricante. No grupo A1, os espécimes foram mantidos em ambiente à prova de luz para que ocorresse apenas a polimerização química. No grupo B1, os espécimes foram cimentados e submetidos à fotoativação imediata, e, no grupo C1, realizou-se a fotoativação após 5 minutos. As raízes foram seccionadas longitudinalmente, para que a linha de cimento pudesse ser exposta e os testes de microdureza realizados. Após 7 dias, as médias de microdureza (± desvio padrão) foram obtidas, para os terços cervical, médio e apical, respectivamente: A1 (Panavia) - 41,25 ±3,38 / 38,17±1,74 / 35,63±1,73; A1 (U100) - 59,43±4,32 / 52,14±3,00 / 50,27±4,13; B1 (Panavia) - 75,29±4,84 / 60,36±6,76 / 48,97±3,33; B1 (U100) 62,41±6,83 / 53,99±4,74 / 49,04±2,20; C1 (Panavia) - 70,22±93 / 61,00±4,48 / 56,46±7,51; C1 (U100) - 62,40±6,66 / 53,69±2,00 / 51,54±2,18. Para os grupos armazenados em água, os valores médios de microdureza (± desvio padrão) obtidos nos 3 grupos, químico (grupo A2), fotoativado imediatamente (grupo B2) e fotoativado tardiamente (grupo C2), nos terços cervical, médio e apical, respectivamente, foram: A2 (Panavia) - 37,17±1,38 / 35,01±0,74 / 34,10±2,37; A2 (U100) - 52,39±2,00 / 52,13±3,01 / 51,06±1,48; B2 (Panavia) - 63,01±2,17 / 55,94±2,10 / 48,55±1,62; B2 (U100) - 58,81±2,34 / 55,19±1,42 / 55,71±3,17; C2 (Panavia) - 56,99±1,21 / 51,29±1,81 / 48,29±3,00; C2 (U100) - 59,02±2,04 / 57,05±2,04 / 54,95±1,05. Os resultados foram submetidos ao teste ANOVA a 4 critérios (cimento, modo de polimerização, armazenamento e terços), que detectou diferenças estatísticas entre os grupos, e o teste de Tukey foi aplicado para comparações individuais. Os resultados mostraram que: a fotoativação com luz halógena promoveu um aumento significativo nos valores de microdureza para o cimento Panavia; o armaz namento em água por três meses reduziu os valores de microdureza para a maioria dos grupos, sendo que o cimento o U100 apresentou menor variação de dureza quando comparado ao Panavia; os terços que receberam maior intensidade de luz halógena tiveram maior aumento de microdureza para ambos os cimentos, especialmente para o cimento Panavia. Conclui-se, portanto, que as hipóteses de nulidade propostas foram rejeitadas. / The objective of this study was to evaluate the microhardness of two dual cure resin cements (RelyX - U100®, 3M-ESPE and Panavia F 2.0®, Kuraray), used for fiberglass posts (Fibrekor ® - Jeneric Pentron) cementation. Chemical cure and a halogen immediate and late light cure source were compared, and the effect of storage in deionized water for three months was also evaluated. This study tested the following null hypotheses: there is no difference between the microhardness values for each dual cure resin cement, cure source type, storage time, or root thirds. Sixty bovine incisor roots 16mm long had their roots restored and then prepared for post cementation. The specimens were divided into 6 groups (n = 10), and each group was subdivided into 2 subgroups with 5 specimens for each cement. The posts were cemented according to manufacturers instructions. In group A1, the specimens were kept in a light-proof environment to ensure only a chemical cure. In group B1, the specimens were restored and subjected to immediate light curing, and in group C1, light curing was performed after 5 minutes. The roots were longitudinally sectioned to expose the cement line and perform microhardness tests. After 7 days, the average microhardness (± standard deviation) values were obtained for the cervical, medium and apical thirds, respectively: A1 (Panavia ) - 41,25±3,38 / 38,17±1,74 / 35,63±1,73; A1 (U100) - 59,43±4,32 / 52,14±3,00 / 50,27±4,13; B1 (Panavia) - 75,29±4,84 / 60,36±6,76 / 48,97±3,33; B1 (U100) - 62,41±6,83 / 53,99±4,74 / 49,04±2,20; C1 (Panavia) - 70,22±1,93 / 61,00±4,48 / 56,46±7,51; C1 (U100) - 62,40±6,66 / 53,69±2,00 / 51,54±2,18. For the 3 groups stored in deionized water (chemical [group A2], immediate light curing [group B2] and late light curing [group C2]), the average microhardness values (± standard deviation) obtained for the cervical, medium and apical thirds, respectively were: A2 (Panavia) - 37,17±1,38 / 35,01±0,74 / 34,10±2,37; A2 (U100) - 52,39±2,00 / 52,13±3,01 / 51,06±1,48; B2 (Panavia) - 63,01±2,17 / 55,94±2,10 / 48,55±1,62; B2 (U100) - 58,81±2,34 / 55,19±1,42 / 55,71±3,17; C2 (Panavia) - 56,99±1,21 / 51,29±1,81 / 48,29±3,00; C2 (U100) - 59,02±2,04 / 57,05±2,04 / 54,95±1,05. ANOVA testing was used to detect statistical differences among the 4 criteria (cements, cure mode, storage and thirds) and the Tukey test was used for individual comparisons. The results showed that the halogen light cure promoted a significant increase in microhardness values for Panavia cement; storage in water for three months reduced microhardness values for most of the groups, although U100 resulted in less microhardness variation compared to Panavia; the thirds that received a higher intensity of halogen light had a higher increase in the average values of microhardness for both cements, especially for Panavia. Therefore, the null hypotheses proposed in this work were rejected.
6

Estudo das propriedades mecânicas e análise da resistência à fratura de resina de metacrilato reforçada com fibra de vidro e partículas de carga utilizada para confecção de pinos intrarradiculares / Study of mechanical properties and analysis of fracture resistance of a methacrylate resin reinforced with fiberglass and filler particles used for making intracanal posts

Favarão, Isabella Negro 06 February 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-09-20T11:52:54Z No. of bitstreams: 2 Dissertação - Isabella Negro Favarão - 2014.pdf: 1147871 bytes, checksum: 0e08616a9e1bff5fb2e39258564e5493 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-09-20T11:53:59Z (GMT) No. of bitstreams: 2 Dissertação - Isabella Negro Favarão - 2014.pdf: 1147871 bytes, checksum: 0e08616a9e1bff5fb2e39258564e5493 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-09-20T11:53:59Z (GMT). No. of bitstreams: 2 Dissertação - Isabella Negro Favarão - 2014.pdf: 1147871 bytes, checksum: 0e08616a9e1bff5fb2e39258564e5493 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2014-02-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The aim of this study was to characterize the mechanical properties (Flexural strength, Diametral tensile strength, Knoop hardness, Young`s modulus, and Poisson's ratio) of a new experimental composite reinforced with glass fiber, and evaluate the fracture resistance and failure mode of bovine roots post-restored with a new experimental composite produce in direct or indirect (laboratory) mode and compare them with prefabricated fiber glass posts. Experimental composite specimens (22.5% resin, 30% 3mm-short silanized glass fibers, and 47.5% of filler particles) were prepared and tested in a universal testing machine according to the particular methodology of each test, scanning electron microscopy analysis was performed on samples fractured in bending test. Thirty endodontically treated bovine roots were divided into 3 groups (n = 10): PFP: prefabricated fiber glass posts EXP-DIR: posts made of experimental material directly polymerised into the root canal EXP-IND: posts made of experimental material indirectly polymerised. Specimens were subjected to compression load (0.5 mm/min), maximum load recorded in Newton, and fracture ranked as the failure mode. Descriptive analyzes showed averages: 259.91 ± 26.01 MPa (Flexural strength); 31.05 ± 2.97 MPa (Diametral Tensile strength); 135.6 ± 24.8 KHN (Knoop Hardness), 5.6 ± 0.95 GPa (Young`s modulus), 0.34 ± 0.02 (Poisson's ratio). ANOVA and Tukey analyzes showed statistical difference for fracture resistance (p <0.05): PFP (620.72 ± 59.29)A, EXP-IND (506.54 ± 27.07)B, EXP-DIR (157.76 ± 32.34)C. The developed composite showed appropriate mechanical properties and feasibility for production of intracanal posts, however dependent on the method of production, being the indirect method the best. / O objetivo deste estudo foi caracterizar as propriedades mecânicas (Resistência à Flexão, Resistência à Tração Diametral, Dureza Knoop, Módulo de Elasticidade, e Coeficiente de Poisson) de um novo compósito experimental reforçado com fibra de vidro polimerizado de maneira convencional, e avaliar a resistência e padrão de fratura de raízes de incisivos bovinos restauradas com pinos confeccionados com o novo compósito experimental de maneira direta ou indireta (laboratorial) e compará-las com pinos de fibra de vidro pré-fabricados. Amostras do compósito experimental (22,5% de resina, 30% de fibra de vidro curta silanizada (3mm), e 47,5% de partículas de carga) foram confeccionadas e testadas em máquina de ensaio universal de acordo com a metodologia específica de cada teste; análise em Microscopia Eletrônica de Varredura foi realizada nas amostras fraturadas no teste de flexão. Trinta raízes bovinas tratadas endodonticamente foram distribuídas em 3 grupos (n=10): PFP: pino de fibra de vidro pré-fabricado; EXP-DIR: pino de fibra de vidro confeccionado com material experimental polimerizado de forma direta no canal radicular; EXP-IND: pino de fibra de vidro confeccionado com o material experimental polimerizado de forma indireta. Os espécimes foram submetidos à carga compressiva (0,5 mm/min), carga máxima registrada em Newton, e classificados quanto ao padrão de fratura. Análises descritivas demonstraram médias: 259,91±26,01 MPa (Resistência Flexural); 31,05±2,97 MPa (Tração Diametral); 135,6±24,8 KHN (Dureza Knoop); 5,6±0,95 GPa (Módulo de Elasticidade); 0,34±0,02 (Coeficiente de Poisson). Análises com ANOVA e Tukey demonstraram diferença estatística (p<0,05) para o teste de resistência à fratura: PFP (620,72±59,29)A, EXP-IND (506,54±27,07)B, EXP-DIR (157,76±32,34)C. O compósito experimental desenvolvido demonstrou propriedades mecânicas adequadas e viabilidade para à confecção de retentores intrarradiculares, entretanto dependente do método de confecção, sendo a confecção indireta o melhor método.
7

Avaliação da espessura de cimento e resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida / Assessment of cement thickness and bond strength of circular fiber posts in post space preparations with an ultrasonic tip developed

Cardenas, José Edgar Valdivia 30 October 2017 (has links)
Preparos para retentores intra-radiculares mais conservadores evitam desgaste desnecessário da estrutura dentinária, requer menos cimento e podem melhorar a retenção adesiva do pino. Assim o objetivo deste estudo foi avaliar a espessura de cimento ea resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida. Trinta incisivos laterais superiores foram preparados com limas reciprocantes Wave One Gold (Dentsply Sirona, Ballaigues, Suiça) e aleatoriamente divididos em 2 grupos (n=15) de acordo com a técnica de preparo para pino: grupo US foram preparados com uma ponta ultrassônica desenvolvida, e grupo WP (controle) com a broca recomendada pelo fabricante do pino. Os pinos de fibra de vidro cônicos WhitePost DC 0.5 (FGM, Joinville, SC, Brasil) foram cimentados utilizando cimento resinoso dual nos terços cervical e médio do canal radicular. Isto posto, todos os espécimes foram seccionados transversalmente em três seções (cervical, média e apical do pino) para análise da área de cimento resinoso ao redor do pino que foi calculada através do programa AutoCAD, em seguida, para avaliar a resistência adesiva, o teste de cisalhamento por extrusão foi aplicado através de uma maquina de ensaio universal numa velocidade média de 0.5 mm/min até o deslocamento do conjunto restaurador intra-radicular e o tipo de falha avaliado por estereomicroscopia. A comparação entre grupos e entre terços da área de cimento e resistência adesiva foram analisadas pelo teste t independente e Anova com Tukey; e os tipos de falha entre os grupos por Mann-Whitney, todos com nível de significância de 5%. No grupo ultrassônico foi observado a menor quantidade de cimento (p<0.05) e a resistência adesiva nos diferentes grupos e terços se manifestou maior somente no terço apical do grupo ultrassônico (p<0.05). Falha adesiva entre cimento e dentina foi a mais prevalente do terço cervical e apical do grupo US e cervical de grupo WP. Falha adesiva entre cimento e pino foi a mais prevalente nos demais terços. Conclui-se que o preparo para retentor com a ponta ultrassônica desenvolvida requer menor quantidade de cimento e influencia na melhor resistência de união no terço apical do pino de fibra de vidro. / Conservative post space preparations for intra-radicular retainers prevent unnecessary desgaste of the dentin structure, require less cement and improve bond strength of the post. The aim of this study was to evaluate the influence of resin cement thickness and bond strength of prefabricated glass fiber circular postin post space preparations with an ultrasonic tip developed. Thirtymaxillarylateral incisors were prepared with Wave One Gold reciprocating files (Dentsply Sirona, Ballaigues, Switzerland) and randomly divided into 2 groups (n=15) according to the post preparation technique: gruoup US was prepared with an ultrasonic tip developed and group WP (control) with the drill recommended by the post fabricant. Every glass fiber posts WhitePost DC 0.5 (FGM, Joinville, SC, Brazil) was cemented using dual polymerizing resin cement in the cervical and middle thirdof the root canal. After that, every specimen was sectioned transversally into three sections(cervical, middle and apical of the post) and the resin cement thickness area was calculated with AutoCAD program, the bond strength test was done with an universal testing machineat medium velocity 0.5 mm/min and the failure pattern after the test was analyzed with stereomicroscopy. Datas obtained were analyzed statistically using Student\'s t-Test, ANOVA,andTukey\'s test. The comparison of failure modes between the groups in the different thirds was done using Mann-Whitney test, All of those at a 5% significance. Ultrasonic group presented thinnest layer of cement in all thirds (p<0,05), which also obtained a higher bond strength only in apical third (p<0,05). Adhesive failurebetween cement and dentinwas the most prevalent of the cervical and apical third of G1 and cervical of G2.Adhesive failure between cement and post was the most prevalent in the others thirds. It can be concluded that the postpreparation with the ultrasonic tip developed provides a smaller thickness of resin cement that influenced thebond strength in the apical third of the glass fiber post.
8

Resistência de união de cimentos resinosos à dentina previamente submetida a radioterapia / Bonding strength of resin cements to the dentin previously submitted to radiotherapy

Yamin, Paulo André 02 February 2017 (has links)
Este estudo avaliou, in vitro, a influência da radioterapia na resistência de união (RU) e na interface adesiva entre diferentes cimentos resinosos e dentina radicular. Sessenta caninos superiores foram distribuídos em 2 grupos (n=30) de acordo com a irradiação: não irradiados e irradiados. Os dentes do grupo irradiado foram submetidos à radioterapia com raios-X de 6 MV em frações de 2 Gy, com 30 ciclos, perfazendo 60 Gy. Os dentes foram seccionados para obtenção de raízes com 16 mm de comprimento, sendo realizado em seguida o preparo biomecânico com instrumento Reciproc R50 e obturação pela técnica de condensação lateral com cimento a base resina epóxica. Cada grupo foi subdividido de acordo com o cimento resinoso utilizado para a cimentação dos pinos de fibra de vidro (n=10): RelyX U200; Panavia F 2.0; RelyX ARC. Os pinos foram submetidos a tratamento de superfície com ácido fluorídrico 10% e cimentados de acordo com as recomendações de cada fabricante. Após a cimentação dos pinos, os dentes foram seccionados transversalmente em slices de 1 mm de espessura, obtendo-se 3 slices de cada terço da raiz. Os slices mais cervicais de cada terço foram utilizados para avaliar a RU, por meio do teste de push-out com velocidade de 0,5 mm/min, e posterior análise do padrão de falha em estereomicroscópio. Os slices mais apicais de cada terço foram selecionados para análise da interface cimento/dentina em MEV com aumentos de 100, 1000, 2000 e 4000X. Os dados de RU e adaptação da interface cimento/dentina foram submetidos à análise estatística pelos testes de ANOVA e Tukey, e Kruskal-Wallis e Duns, respectivamente. Os espécimes irradiados apresentaram menores valores de RU (8,23&plusmn;4,26) comparados aos dentes não irradiados (11,88&plusmn;6,42) (p<0,00001). Quanto aos cimentos resinosos, o RelyX U200 apresentou maiores valores na RU (15,17&plusmn;5,89) comparado aos cimentos RelyX ARC (7,68&plusmn;4,22) (p<0,0001) e Panavia F 2.0 (7,32&plusmn;2,71) (p<0,0001). O terço cervical apresentou maiores valores de RU (13,08&plusmn;6,10) comparado aos terços médio (9,72&plusmn;5,03) e apical (7,38&plusmn;4,53) (p<0,0001). O padrão de falhas mostrou ocorrência de falhas coesivas na dentina para os espécimes irradiados. Na análise da interface cimendo/dentina por MEV, observou-se maior desadaptação nos dentes submetidos à radioterapia. Em relação aos cimentos resinosos, foi observada maior adaptação com RelyX U200 e RelyX ARC comparados à Panavia F 2.0. Na análise qualitativa em MEV observou-se presença de fraturas e microfraturas na dentina radicular e menor presença de fibras colágenas em dentes irradiados. Para o cimento resinoso RelyX U200 e Panavia F 2.0 observou-se interface justaposta do cimento com a dentina radicular em dentes irradiados e não irradiados, sendo que para o cimento resinoso RelyX ARC foi observada formação de camada híbrida e tags de maneira similar para dentes irradiados e não irradiados. Concluiu-se que a radioterapia resultou na redução da resistência de união e na maior desadaptação da interface cimento resinoso/dentina radicular e que o cimento resinoso autoadesivo se apresentou como melhor alternativa para cimentação de pinos de fibra de vidro em dentes irradiados. / This in vitro study, evaluated the influency of radiotherapy on bond strength (BS) and adhesive interface between different resin cements and root dentin. Sixty maxillary canines were selected and distributed into two groups (n = 30) according to the irradiation protocol: non-irradiated and irradiated. The irradiated group were submitted to X-ray radiotherapy of 6 MV in fractions of 2 Gy, with 30 cycles, until complete 60 Gy. The teeth were sectioned to obtain 16 mm of root length, followed by biomechanical preparation with R50 reciproc instrument and obturation using the lateral condensation technique with epoxy resin-based sealer. Then, each group was subdivided according to the resin cement used for the glass fiber post cementation (n = 10): RelyX U200, Panavia F 2.0 and RelyX ARC. The posts were submitted to surface treatment with 10% hydrofluoric acid, and then cemented according to the manufacturer instructions. After the posts cementation, the teeth were sectioned transversely into 1 mm thick slices, and 3 slices were obtained from each root third. The most cervical slice of each third was used to evaluate the BS by the push-out test at 0.5 mm/min of velocity and the failure pattern was analyzed using stereomicroscopy. The most apical slice of each third was selected for SEM analysis, which were prepared and metalized. The dentin/cement interface analysis was performed at the following magnification: 100, 1000, 2000 and 4000X. The BS data and dentin/cement interface adaptation were submitted to statistical analysis by ANOVA, Tukey and Kruskal-Wallis, and Duns tests respectively. The irradiated specimens had lower BS values (8.23 &plusmn; 4.26) compared to non-irradiated group (11.88 &plusmn; 6.42) (p <0.00001). Regarding the resin cements, the RelyX U200 showed the higher values in BS (15.17 &plusmn; 5.89) compared to RelyX ARC (7.68 &plusmn; 4.22) and Panavia F 2.0 (7 , 32 &plusmn; 2.71) (p <0.0001). In addition, the cervical third presented higher BS values (13.08 &plusmn; 6.10) when compared to the middle (9.72 &plusmn; 5.03) and apical (7.38 &plusmn; 4.53) thirds (p <0.0001). The failure pattern showed cohesive failures in root dentin of the irradiated specimens. In the SEM dentin/cement interface analysis, a greater misadaptation was observed for the teeth submitted to radiotherapy. Regarding the resin cements, a better adaptation was observed for the RelyX U200 and RelyX ARC compared to the Panavia F 2.0. In the SEM qualitative analysis of the irradiated teeth, was possible to observe the presence of fractures and microfractures in the root dentin and a small number of collagen fibers. The resin cements RelyX U200 and Panavia F 2.0 showed a juxtaposed interface of the cement with the root dentin in irradiated and non-irradiated teeth, being that for the RelyX ARC cement the presence of hybrid layer and tags was similar for irradiated and non-irradiated groups. It was concluded that the radiotherapy promoted reduction of the bond strength and increase the gaps in the dentin/resin cement interface and the self-adhesive resin cement is the best alternative for glass fiber posts cementation in irradiated teeth.
9

Avaliação da espessura de cimento e resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida / Assessment of cement thickness and bond strength of circular fiber posts in post space preparations with an ultrasonic tip developed

José Edgar Valdivia Cardenas 30 October 2017 (has links)
Preparos para retentores intra-radiculares mais conservadores evitam desgaste desnecessário da estrutura dentinária, requer menos cimento e podem melhorar a retenção adesiva do pino. Assim o objetivo deste estudo foi avaliar a espessura de cimento ea resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida. Trinta incisivos laterais superiores foram preparados com limas reciprocantes Wave One Gold (Dentsply Sirona, Ballaigues, Suiça) e aleatoriamente divididos em 2 grupos (n=15) de acordo com a técnica de preparo para pino: grupo US foram preparados com uma ponta ultrassônica desenvolvida, e grupo WP (controle) com a broca recomendada pelo fabricante do pino. Os pinos de fibra de vidro cônicos WhitePost DC 0.5 (FGM, Joinville, SC, Brasil) foram cimentados utilizando cimento resinoso dual nos terços cervical e médio do canal radicular. Isto posto, todos os espécimes foram seccionados transversalmente em três seções (cervical, média e apical do pino) para análise da área de cimento resinoso ao redor do pino que foi calculada através do programa AutoCAD, em seguida, para avaliar a resistência adesiva, o teste de cisalhamento por extrusão foi aplicado através de uma maquina de ensaio universal numa velocidade média de 0.5 mm/min até o deslocamento do conjunto restaurador intra-radicular e o tipo de falha avaliado por estereomicroscopia. A comparação entre grupos e entre terços da área de cimento e resistência adesiva foram analisadas pelo teste t independente e Anova com Tukey; e os tipos de falha entre os grupos por Mann-Whitney, todos com nível de significância de 5%. No grupo ultrassônico foi observado a menor quantidade de cimento (p<0.05) e a resistência adesiva nos diferentes grupos e terços se manifestou maior somente no terço apical do grupo ultrassônico (p<0.05). Falha adesiva entre cimento e dentina foi a mais prevalente do terço cervical e apical do grupo US e cervical de grupo WP. Falha adesiva entre cimento e pino foi a mais prevalente nos demais terços. Conclui-se que o preparo para retentor com a ponta ultrassônica desenvolvida requer menor quantidade de cimento e influencia na melhor resistência de união no terço apical do pino de fibra de vidro. / Conservative post space preparations for intra-radicular retainers prevent unnecessary desgaste of the dentin structure, require less cement and improve bond strength of the post. The aim of this study was to evaluate the influence of resin cement thickness and bond strength of prefabricated glass fiber circular postin post space preparations with an ultrasonic tip developed. Thirtymaxillarylateral incisors were prepared with Wave One Gold reciprocating files (Dentsply Sirona, Ballaigues, Switzerland) and randomly divided into 2 groups (n=15) according to the post preparation technique: gruoup US was prepared with an ultrasonic tip developed and group WP (control) with the drill recommended by the post fabricant. Every glass fiber posts WhitePost DC 0.5 (FGM, Joinville, SC, Brazil) was cemented using dual polymerizing resin cement in the cervical and middle thirdof the root canal. After that, every specimen was sectioned transversally into three sections(cervical, middle and apical of the post) and the resin cement thickness area was calculated with AutoCAD program, the bond strength test was done with an universal testing machineat medium velocity 0.5 mm/min and the failure pattern after the test was analyzed with stereomicroscopy. Datas obtained were analyzed statistically using Student\'s t-Test, ANOVA,andTukey\'s test. The comparison of failure modes between the groups in the different thirds was done using Mann-Whitney test, All of those at a 5% significance. Ultrasonic group presented thinnest layer of cement in all thirds (p<0,05), which also obtained a higher bond strength only in apical third (p<0,05). Adhesive failurebetween cement and dentinwas the most prevalent of the cervical and apical third of G1 and cervical of G2.Adhesive failure between cement and post was the most prevalent in the others thirds. It can be concluded that the postpreparation with the ultrasonic tip developed provides a smaller thickness of resin cement that influenced thebond strength in the apical third of the glass fiber post.
10

EFEITO DE SOLUÇÕES ATIVADAS POR ULTRASSOM NA RESISTÊNCIA ADESIVA DE PINOS DE FIBRA DE VIDRO CIMENTADOS COM CIMENTO RESINOSO AUTOADESIVO / EFFECT OF INTRACANAL IRRIGANTS ON BOND STRENGH OF FIBER POSTS CEMENTED WITH A SELF-ADHESIVE RESIN CEMENT

Barreto, Mirela Sangoi 07 July 2015 (has links)
The current study aimed to evaluate the effect of irrigating and chelating solutions on bond strength of fiber glass posts cemented with RelyX U200. 60 single-rooted premolars were sectioned at 14 mm from the apex, prepared with ProTaper Universal system until F3 instrument and filled with F3 master cone and AH Plus sealer. Root canal filling was partially removed, remaining 4 mm of guta-percha at the apical third. Specimens were randomly divided into 5 experimental groups (n=12), according to the solution used before fiber post cementation (dentin surface treatment), as described: EDTA 17% (EDTA); QMix (QM); SmearClear (SC); NaOCl 2.5% (NaOCl) and saline solution as control group (SS). Ultrasonic activation was performed three times, during 20 seconds each and root canals were dried with paper points. Exacto N2 glass fiber posts were cemented with RelyX U200. Rhodamine B dye was mixed to RelyX U200 in one specimen per group, in order to provide fluorescence for confocal laser scanning microscopy (CLSM) assessment. A cutting machine was used for root s sectioning, providing 3 slices, one for each root third. Next, push-out test was performed. Stereomicroscope and CLSM were used to analyze the failure mode and to illustrate the pattern of distribution of RelyX U200 inside dentinal tubules, respectively. Bond strength mean were calculated and ANOVA and Bonferroni tests were used for statistical analysis. SS showed the higher mean of bond strength values, superior to QM, SC (P < .05). NaOCl presented intermediary bond strength values, similar to EDTA and SS (P > .05). QM and SC showed the lowest mean of bond strength (P < .05). In conclusion, SS and NaOCl associated to ultrasonic activation seems to be adequate solutions for root canal cleaning before fiber post cementation with RelyX U200, while chelating solutions, such as EDTA, QMix and SmearClear, should not be used for dentin pre-treatment when cementing with RelyX U200. / O presente estudo tem por objetivo avaliar o efeito de diferentes soluções irrigantes e quelantes na resistência adesiva de pinos de fibra de vidro cimentados com cimento autoadesivo RelyX U200. 60 pré-molares inferiores extraídos de humanos, padronizados em 14 mm, foram preparados com o sistema ProTaper Universal até o instrumento F3, obturados com cimento AH Plus e cones F3 do mesmo sistema. Os espécimes foram desobturados parcialmente, restando 4 mm apicais de material obturador e realocados em quatro grupos experimentais e um controle (n=12), de acordo com a solução de tratamento de superfície dentinária prévia à cimentação dos pinos: EDTA 17% (EDTA), QMix (QM), SmearClear (SC), Soro Fisiológico (SS) e NaOCl 2,5% (NaOCl). As soluções foram ativadas por ultrassom em três etapas, durante 20 segundos cada e os canais foram secos com pontas de papel absorventes. Os pinos de fibra de vidro do Sistema Exacto Translúcido N2 foram cimentados com RelyX U200. Em um espécime por grupo foi incorporada Rodamina B ao cimento autoadesivo como marcador fluorescente para análise em Microscopia Confocal à laser (MECL). Foram seccionados 3slices por espécime, sendo 1 slice por terço radicular, e submetidos ao teste de push-out na máquina de ensaio universal EMIC. Estereomicroscópio e MECL foram utilizados para analisar o padrão de falha dos espécimes e o padrão de penetração do cimento autoadesivo nos túbulos dentinários, respectivamente. A média de resistência adesiva de cada espécime foi calculada. Testes ANOVA e Bonferroni foram utilizados para analisar as diferenças entre os grupos. SS demonstrou a maior média de resistência adesiva, sendo superior aos grupos QM, SC (P <.05). NaOCl apresentou valores intermediários de resistência adesiva, similares ao EDTA e SS (P > .05). QM e SC apresentaram as menores médias de resistência adesiva (P < .05). Pode-se concluir que o uso de SS e NaOCl parece ser adequado para lavagem do canal prévia à cimentação de pinos de fibra de vidro, com uso de cimento resinoso autoadesivo RelyX U200. O uso de soluções quelantes como EDTA, QM e SC parece interferir negativamente nos valores de resistência adesiva.

Page generated in 0.2816 seconds