• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Fatty Acid Biomarker Detection for Breast Cancer Using Differential Mobility Spectrometry with Non-Radioactive Ion Source

Alberti, James Joseph 21 March 2017 (has links)
Differential Mobility Spectrometry (DMS) using a non-radioactive ion source (NRIS) is investigated as a possible medical diagnostic instrument for near real-time detection of breast cancer biomarkers. In previous clinical studies, concentrations of Linoleic, Palmitic and Stearic fatty acids have been observed at different levels in women with carcinoma breast cancer versus women with benign tumors or healthy women showing no signs of breast cancer. Present diagnostic methods require a biopsy of the suspect tissue and a microscopic lab analysis performed to determine its disease state. This process can take hours or days before the patient and doctor are informed of the results. Controlled volumetric samples of each fatty acid listed above were introduced into a DMS instrument, using a NRIS, to determine detectability of each acid. The results provide proof-of-concept that Linoleic, Palmitic and Stearic fatty acids can be uniquely identified by varying the sample temperature and scanning the ionized fatty acid molecules in both the negative and positive ion mode of the DMS instrument. Detection response times range from 2 to 6 seconds for initial detection up to 35 seconds for peak detection. The Limit of Detection for the DMS instrument is estimated in the low parts per billion.
2

Desenvolvimento de um sensor eletroquímico planar modificado com 1-2 Diaminobenzeno (DAB) para monitoração de nitrito por FIA-automatizada. / Development of a planar electrochemical sensor modified with 1-2 Diaminobenzene (DAB) for nitrite measuring by automatic FIA.

Almeida, Fernando Luis de 11 September 2009 (has links)
A presente dissertação de mestrado tem o propósito de relatar o desenvolvimento de um sensor planar eletroquímico com três eletrodos para o monitoramento de nitrito e seus interferentes (ácido úrico, ácido ascórbico e paracetamol). Para tal, no procedimento experimental é descrito o desenvolvimento do aparato extracorpóreo (mini-bomba compressora, válvulas solenóides e cela de análise). Esse é acoplado a um sistema de Análise por Injeção em Fluxo Automatizada (do inglês, Flow-injection Analysis) FIA-automatizada. Este trabalho também descreve a fabricação dos sensores em substrato de alumina, o processo de limpeza padrão dos eletrodos, o processo de obtenção dos eletrodos de referência em HCl (0,1 mol L-1) e ativação eletroquímica da superfície do eletrodo de trabalho com H2SO4 (0,1 mol L-1). Em seguida, é mostrada a estabilização dos eletrodos de referência Ag/AgCl em solução salina contendo cloretos, o estudo da secagem dos eletrodos em temperatura ambiente com exposição à luz e a caracterização dos mesmos por três métodos distintos, a saber: i) teste de reversibilidade (corrente redox vs. potencial); ii) variação do potencial com o tempo (coeficiente de degradação termodinâmica) e iii) variação do potencial com a concentração de cloretos. Também, apresenta-se a caracterização da área efetiva exposta do eletrodo de medição (trabalho) e os resultados da deposição de 1-2 Diaminobenzeno (DAB) como polímero seletivo. Além disso, são apresentados os resultados e discussões dos pseudo-eletrodos (recoberto ou não com Náfion® 117). Um ponto relacionado, a histerese associada à irreversibilidade dos eletrodos de referência resultou da ordem de 40 mVAg/AgCl Náfion® 117. Os potencias termodinâmicos observados foram da ordem de 100 ± 6 mVAg/AgCl Náfion® 117 para pseudo-eletrodo de referência sem e com Náfion® 117. Depois, foi realizado um estudo criterioso dos potenciais de resposta ao nitrito e aos interferentes por meio da técnica de DPV (do inglês, Differencial Pulse Voltammetry). Para evitar degradação acelerada (corrosão) do polímero sobre o eletrodo de trabalho, optou-se por realizar as medições com potencial igual a 0,50 VAg/AgCl Náfion® 117. Nessa condição, apresenta-se a monitoração de nitrito por FIA-automatizada na faixa de concentração de 50 a 250 mol L-1. Os resultados para a medição de nitrito mostraram que o sensor planar eletroquímico amperométrico desenvolvido é promissor, pois esse apresentou ótimo desempenho de reprodutividade (99,66%), sensibilidade (90 microA mol-1 L mm-2), seletividade (0,32%), repetitividade (91,28%) e estabilidade (15 ± 0,3 pA). / In this Master of Science, it has been developed an electrochemical planar sensor defined with three electrodes for nitrite measuring and its interferents (uric acid, ascorbic acid and paracetamol). In the experimental procedure, it is shown the development of an extracorporis set up (mini-pump, solenoid valves and analysis cell) which is coupled to a system of Flow-injection Analysis (FIA). This work also describes the sensor fabrication using alumina substrates, the standard cleaning of the electrodes, the process to obtain Ag/AgCl reference electrodes in HCl (0.1 mol L-1) and electrochemical activation of the working-electrode surface with H2SO4 (0.1 mol L-1). Following, it is shown the study of drying for electrodes at room temperature with exposition to room light and their characterization using three different methods: i) reversibility test (redox current vs. potential); ii) variation of the potential with the time (thermodynamics degradation coefficient) and iii) variation of the potential with the chloride concentration. Also, it is presented the characterization of the effective exposed area of the working electrode and the results of the deposited 1-2 Diaminobenzene (DAB) is presented as a selective polymer. In addition, the results and discussions of the pseudo-reference (recovered or not with Nafion® 117) are presented. Related to irreversibility is the hysteresis associated to the reference electrodes which resulted in the order of 40 mVAg/AgCl Nafion® 117. The observed thermodynamic potentials were of (100 ± 6) mVAg/AgCl Nafion® 117 for pseudo-electrodes recovered with Nafion® 117. Later on, a careful study of the response to nitrite and to its interferents was performed by means of the DPV technique (Differential Pulse Voltammetry). In order to avoid accelerated degradation (corrosion) of the polymer, measurements were performed at a potential of 0,5 VAg/AgCl Nafion® 117. In this condition, nitrite was monitored using the automatized-FIA (Flow Injection Analysis) for concentration in the range of 50 to 250 mol L-1. The results have shown that the planar amperometric sensor for nitrite measuring is usefull since it was observed excellent performance related to reproducibility (99.66%), sensitivity (90 microA mol-1 L mm-2), selectivity (0.32%), repetibility (91.28%) and stability (15.0 ± 0.3 pA).
3

Desenvolvimento de um sensor eletroquímico planar modificado com 1-2 Diaminobenzeno (DAB) para monitoração de nitrito por FIA-automatizada. / Development of a planar electrochemical sensor modified with 1-2 Diaminobenzene (DAB) for nitrite measuring by automatic FIA.

Fernando Luis de Almeida 11 September 2009 (has links)
A presente dissertação de mestrado tem o propósito de relatar o desenvolvimento de um sensor planar eletroquímico com três eletrodos para o monitoramento de nitrito e seus interferentes (ácido úrico, ácido ascórbico e paracetamol). Para tal, no procedimento experimental é descrito o desenvolvimento do aparato extracorpóreo (mini-bomba compressora, válvulas solenóides e cela de análise). Esse é acoplado a um sistema de Análise por Injeção em Fluxo Automatizada (do inglês, Flow-injection Analysis) FIA-automatizada. Este trabalho também descreve a fabricação dos sensores em substrato de alumina, o processo de limpeza padrão dos eletrodos, o processo de obtenção dos eletrodos de referência em HCl (0,1 mol L-1) e ativação eletroquímica da superfície do eletrodo de trabalho com H2SO4 (0,1 mol L-1). Em seguida, é mostrada a estabilização dos eletrodos de referência Ag/AgCl em solução salina contendo cloretos, o estudo da secagem dos eletrodos em temperatura ambiente com exposição à luz e a caracterização dos mesmos por três métodos distintos, a saber: i) teste de reversibilidade (corrente redox vs. potencial); ii) variação do potencial com o tempo (coeficiente de degradação termodinâmica) e iii) variação do potencial com a concentração de cloretos. Também, apresenta-se a caracterização da área efetiva exposta do eletrodo de medição (trabalho) e os resultados da deposição de 1-2 Diaminobenzeno (DAB) como polímero seletivo. Além disso, são apresentados os resultados e discussões dos pseudo-eletrodos (recoberto ou não com Náfion® 117). Um ponto relacionado, a histerese associada à irreversibilidade dos eletrodos de referência resultou da ordem de 40 mVAg/AgCl Náfion® 117. Os potencias termodinâmicos observados foram da ordem de 100 ± 6 mVAg/AgCl Náfion® 117 para pseudo-eletrodo de referência sem e com Náfion® 117. Depois, foi realizado um estudo criterioso dos potenciais de resposta ao nitrito e aos interferentes por meio da técnica de DPV (do inglês, Differencial Pulse Voltammetry). Para evitar degradação acelerada (corrosão) do polímero sobre o eletrodo de trabalho, optou-se por realizar as medições com potencial igual a 0,50 VAg/AgCl Náfion® 117. Nessa condição, apresenta-se a monitoração de nitrito por FIA-automatizada na faixa de concentração de 50 a 250 mol L-1. Os resultados para a medição de nitrito mostraram que o sensor planar eletroquímico amperométrico desenvolvido é promissor, pois esse apresentou ótimo desempenho de reprodutividade (99,66%), sensibilidade (90 microA mol-1 L mm-2), seletividade (0,32%), repetitividade (91,28%) e estabilidade (15 ± 0,3 pA). / In this Master of Science, it has been developed an electrochemical planar sensor defined with three electrodes for nitrite measuring and its interferents (uric acid, ascorbic acid and paracetamol). In the experimental procedure, it is shown the development of an extracorporis set up (mini-pump, solenoid valves and analysis cell) which is coupled to a system of Flow-injection Analysis (FIA). This work also describes the sensor fabrication using alumina substrates, the standard cleaning of the electrodes, the process to obtain Ag/AgCl reference electrodes in HCl (0.1 mol L-1) and electrochemical activation of the working-electrode surface with H2SO4 (0.1 mol L-1). Following, it is shown the study of drying for electrodes at room temperature with exposition to room light and their characterization using three different methods: i) reversibility test (redox current vs. potential); ii) variation of the potential with the time (thermodynamics degradation coefficient) and iii) variation of the potential with the chloride concentration. Also, it is presented the characterization of the effective exposed area of the working electrode and the results of the deposited 1-2 Diaminobenzene (DAB) is presented as a selective polymer. In addition, the results and discussions of the pseudo-reference (recovered or not with Nafion® 117) are presented. Related to irreversibility is the hysteresis associated to the reference electrodes which resulted in the order of 40 mVAg/AgCl Nafion® 117. The observed thermodynamic potentials were of (100 ± 6) mVAg/AgCl Nafion® 117 for pseudo-electrodes recovered with Nafion® 117. Later on, a careful study of the response to nitrite and to its interferents was performed by means of the DPV technique (Differential Pulse Voltammetry). In order to avoid accelerated degradation (corrosion) of the polymer, measurements were performed at a potential of 0,5 VAg/AgCl Nafion® 117. In this condition, nitrite was monitored using the automatized-FIA (Flow Injection Analysis) for concentration in the range of 50 to 250 mol L-1. The results have shown that the planar amperometric sensor for nitrite measuring is usefull since it was observed excellent performance related to reproducibility (99.66%), sensitivity (90 microA mol-1 L mm-2), selectivity (0.32%), repetibility (91.28%) and stability (15.0 ± 0.3 pA).

Page generated in 0.0592 seconds