• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do modo de falha de coroas cerâmicas com e sem alteração do desenho das infraestruturas / Evaluation of failure mode of ceramic crowns with and without framework design modification.

Lorenzoni, Fabio Cesar 25 March 2009 (has links)
Coroas cerâmicas têm sido amplamente utilizadas, entretanto, problemas relacionados com a fratura destes materiais persistem principalmente nos sistemas ceramocerâmicos na região de molar. As hipóteses nulas testadas foram que o desenho da infraestrutura e o tipo de material não terão efeito significante na resistência à fadiga. Coroas metalocerâmicas e ceramocerâmicas foram fabricadas sobre o preparo de um molar superior, o qual reproduzia a complexa morfologia dos preparos dentários. Quatro grupos foram estabelecidos (n=10 por grupo) baseados no desenho das infraestruturas (padrão ou alterada) das coroas metalocerâmicas (MC) e das ceramocerâmicas (CC), denominadas de MCSA e CCSA para as I.E. com desenho padrão e MCCA e CCCA para as com alteração no seu desenho. As infraestruturas com desenho padrão apresentaram espessura de 0,5mm em todas as suas paredes e as com alteração no desenho apresentaram a cinta lingual com 2,0mm de altura e postes proximais com 3,5mm de altura e as demais áreas com 0,5mm de espessura. As coroas ceramocerâmicas consistiam do sistema à base de alumina (In-Ceram Alumina slip cast) e as infraestruturas das coroas metalocerâmicas foram fabricadas com metal não nobre (Ni-Cr). Todas as coroas foram cimentadas com cimento resinoso Rely X ARC sobre uma réplica do preparo de resina composta, a qual teve a proposta de simular o módulo de elasticidade encontrado na dentina. Estas coroas foram submetidas ao teste de resistência à fadiga, ciclagem dinâmica, por 106 ciclos ou até que qualquer tipo de fratura fosse observada, com carga variando entre 30-300N. A força foi aplicada axialmente entre as vertentes palatina e vestibular, com endentador metálico esférico. Em intervalos de 125.000 as coroas eram verificadas à procura de danos com auxílio de estereomicroscopia. As coroas que não sofreram fraturas foram polidas sequencialmente e cada corpo de prova recebeu escores de acordo com o tipo de falha apresentada. O teste Kruskal Wallis foi utilizado para verificar se houve diferença estatisticamente significante entre os materiais e o teste de Student-Newman-Keusl foi utilizado para as comparações múltiplas. Diferenças estatisticamente significante foi encontrada entre materiais e desenhos, entretanto, os grupos com I.E. metálica (MCCA e MCSA) não apresentaram diferença estatisticamente significante. O grupo CCCA mostrou diferença estatisticamente significante em relação ao grupo CCSA. A presença do metal na infraestrutura foi preponderante na resistência à fadiga. A alteração no desenho da infraestrutura cerâmica provou ser superior em relação ao desenho sem alteração. / Ceramic crowns have been widely used, however, problems related to brittle fracture of these materials persist, especially in the posterior area. The present study tested the null hypothesis that there were no differences in fatigue resistance related to the framework design as well as to the materials used. One maxillary molar was prepared, reproducing the complex morphology of a dental preparation, to receive metal-ceramic and all-ceramic crowns. Four groups (n=10) were established based on framework designs (standard and modified) for metal-ceramic (MC) and all-ceramic (CC) crowns, named as MCSA and CCSA for standard framework designs and MCCA and CCCA for the proposed framework design modifications. On the standard design, frameworks presented 0.5mm thick walls and those with design modification a 0.5mm thick framework with a vertical increase of 2.0mm lingual and 3.5mm proximal walls. All-ceramic frameworks were made with In-Ceram Alumina slip cast and the metal-ceramic frameworks were made with nickel-chromium alloy. All crowns were cemented with resin cement (Rely X ARC) on resin composite replicas, witch have an elastic modulus similar to dentin. They were subjected to dynamic cycling fatigue test (106 cycles or until fracture), at ranging load of 30-300N. Load was located between the buccal and lingual cuspals of the crowns. At 125.000 cycles intervals, crowns were analysed under a stereomicroscopy to search for damages. Crowns without fracture were polished sequentially and received scores according to the failure mode. Kruskal Wallis test was used to check if there were a significant differences between the framework design and materials (metal and ceramic) and the Student-Newman-Keuls was used for multiple comparisons. Significant differences were found between materials and designs, however, both metal frameworks (MCCA e MCSA) were similar. CCCA group showed higher survival than CCSA group. The metal presence in the framework seemed to improve the resistance to fatigue test. However, the design modification in ceramics achieved better results than the standard design.
2

Avaliação da distribuição das tensões ao redor de implantes em diferentes níves de inserção / Stress distribution around dental implants placed at different depths: a photoelastic evaluation

Zanardi, Piero Rocha 16 February 2017 (has links)
A perda óssea progressiva ao redor da plataforma dos implantes dentários é um desafio a ser vencido na clínica, uma vez que, interfere na manutenção e controle dos tecidos peri-implantares e pode afetar a estética. Esta pesquisa teve como objetivo avaliar a concentração de tensões ao redor de diferentes implantes dentários, variando a macrogeometria, conexão protética e profundidade da inserção da plataforma protética, sob carregamento axial ou oblíquo. Foram criados três modelos de resina fotoelástica para cada tipo de implante avaliado (hexágono externo, hexágono externo wedge, hexágono interno e cone Morse). Cada corpo de prova se diferenciou pelo posicionamento da plataforma do implante em relação à margem superior do bloco, em três posições diferentes: I - plataforma posicionada 2mm abaixo da margem do bloco; II - plataforma posicionada no mesmo nível da margem do bloco; III - plataforma posicionada 2mm acima da margem do bloco. Foi aplicada uma força de 100N através de um dispositivo instalado sobre pilares retos e angulados, simulando um carregamento axial e oblíquo respectivamente. Um total de 4 pontos foram avaliados de um lado do implante. Dados quantitativos foram coletados e utilizados para análise estatística. A regressão linear múltipla mostrou relação entre a distribuição das tensões com relação à profundidade de inserção independentemente do tipo de conexão protética ou do carregamento oclusal. O grupo I (2mm abaixo da margem) foi o que apresentou os menores valores (p<0.05) de tensão quando comparado com os outros grupos (II e III). De acordo com as limitações deste estudo pode-se concluir que a macrogeometria, profundidade de inserção da plataforma e tipo de carregamento oclusal influenciam no comportamento da distribuição das tensões ao redor dos implantes. Em relação à conexão protética, os resultados mostraram padrões de franjas semelhantes independentemente do tipo de conexão / The progressive bone loss at the neck of dental implant is a clinical concern since it affects the maintenance of dental esthetics. The stress concentration, the connection type and the microgap appear to be factors that cause alterations at the marginal bone level. The aim of this research was to evaluate the stress concentration around different dental implants, varying the macrogeometry, prosthetic connection and depth of the insertion of the prosthetic platform, under axial or oblique loading. Three blocks of photoelastic resin for each type of implant connection (external hexagon, external hexagon flattened, internal hexagon and Morse taper) were built. Each block differed in the position of the implant platform in relative to the upper margin of the block: I (2mm below), II (at the same level) and III (2mm above). A force of 100N was applied to both a straight and tilted abutments. A multiple linear regression showed the relation between the stress distribution and the insertion depth. For all the implant types, both with straight and tilted abutments, Group I presented the lowest stress concentration around the fixture when compared to group II and III (p<0,05). According to the limitations of this study it could be concluded that the macrogeometry, depth of insertion of the platform and type of occlusal loading influence the behavior of the distribution of stresses around the implants. Regarding the prosthetic connection, the results showed similar patterns of fringes regardless of the type of connection
3

Avaliação do modo de falha de coroas cerâmicas com e sem alteração do desenho das infraestruturas / Evaluation of failure mode of ceramic crowns with and without framework design modification.

Fabio Cesar Lorenzoni 25 March 2009 (has links)
Coroas cerâmicas têm sido amplamente utilizadas, entretanto, problemas relacionados com a fratura destes materiais persistem principalmente nos sistemas ceramocerâmicos na região de molar. As hipóteses nulas testadas foram que o desenho da infraestrutura e o tipo de material não terão efeito significante na resistência à fadiga. Coroas metalocerâmicas e ceramocerâmicas foram fabricadas sobre o preparo de um molar superior, o qual reproduzia a complexa morfologia dos preparos dentários. Quatro grupos foram estabelecidos (n=10 por grupo) baseados no desenho das infraestruturas (padrão ou alterada) das coroas metalocerâmicas (MC) e das ceramocerâmicas (CC), denominadas de MCSA e CCSA para as I.E. com desenho padrão e MCCA e CCCA para as com alteração no seu desenho. As infraestruturas com desenho padrão apresentaram espessura de 0,5mm em todas as suas paredes e as com alteração no desenho apresentaram a cinta lingual com 2,0mm de altura e postes proximais com 3,5mm de altura e as demais áreas com 0,5mm de espessura. As coroas ceramocerâmicas consistiam do sistema à base de alumina (In-Ceram Alumina slip cast) e as infraestruturas das coroas metalocerâmicas foram fabricadas com metal não nobre (Ni-Cr). Todas as coroas foram cimentadas com cimento resinoso Rely X ARC sobre uma réplica do preparo de resina composta, a qual teve a proposta de simular o módulo de elasticidade encontrado na dentina. Estas coroas foram submetidas ao teste de resistência à fadiga, ciclagem dinâmica, por 106 ciclos ou até que qualquer tipo de fratura fosse observada, com carga variando entre 30-300N. A força foi aplicada axialmente entre as vertentes palatina e vestibular, com endentador metálico esférico. Em intervalos de 125.000 as coroas eram verificadas à procura de danos com auxílio de estereomicroscopia. As coroas que não sofreram fraturas foram polidas sequencialmente e cada corpo de prova recebeu escores de acordo com o tipo de falha apresentada. O teste Kruskal Wallis foi utilizado para verificar se houve diferença estatisticamente significante entre os materiais e o teste de Student-Newman-Keusl foi utilizado para as comparações múltiplas. Diferenças estatisticamente significante foi encontrada entre materiais e desenhos, entretanto, os grupos com I.E. metálica (MCCA e MCSA) não apresentaram diferença estatisticamente significante. O grupo CCCA mostrou diferença estatisticamente significante em relação ao grupo CCSA. A presença do metal na infraestrutura foi preponderante na resistência à fadiga. A alteração no desenho da infraestrutura cerâmica provou ser superior em relação ao desenho sem alteração. / Ceramic crowns have been widely used, however, problems related to brittle fracture of these materials persist, especially in the posterior area. The present study tested the null hypothesis that there were no differences in fatigue resistance related to the framework design as well as to the materials used. One maxillary molar was prepared, reproducing the complex morphology of a dental preparation, to receive metal-ceramic and all-ceramic crowns. Four groups (n=10) were established based on framework designs (standard and modified) for metal-ceramic (MC) and all-ceramic (CC) crowns, named as MCSA and CCSA for standard framework designs and MCCA and CCCA for the proposed framework design modifications. On the standard design, frameworks presented 0.5mm thick walls and those with design modification a 0.5mm thick framework with a vertical increase of 2.0mm lingual and 3.5mm proximal walls. All-ceramic frameworks were made with In-Ceram Alumina slip cast and the metal-ceramic frameworks were made with nickel-chromium alloy. All crowns were cemented with resin cement (Rely X ARC) on resin composite replicas, witch have an elastic modulus similar to dentin. They were subjected to dynamic cycling fatigue test (106 cycles or until fracture), at ranging load of 30-300N. Load was located between the buccal and lingual cuspals of the crowns. At 125.000 cycles intervals, crowns were analysed under a stereomicroscopy to search for damages. Crowns without fracture were polished sequentially and received scores according to the failure mode. Kruskal Wallis test was used to check if there were a significant differences between the framework design and materials (metal and ceramic) and the Student-Newman-Keuls was used for multiple comparisons. Significant differences were found between materials and designs, however, both metal frameworks (MCCA e MCSA) were similar. CCCA group showed higher survival than CCSA group. The metal presence in the framework seemed to improve the resistance to fatigue test. However, the design modification in ceramics achieved better results than the standard design.
4

Avaliação da distribuição das tensões ao redor de implantes em diferentes níves de inserção / Stress distribution around dental implants placed at different depths: a photoelastic evaluation

Piero Rocha Zanardi 16 February 2017 (has links)
A perda óssea progressiva ao redor da plataforma dos implantes dentários é um desafio a ser vencido na clínica, uma vez que, interfere na manutenção e controle dos tecidos peri-implantares e pode afetar a estética. Esta pesquisa teve como objetivo avaliar a concentração de tensões ao redor de diferentes implantes dentários, variando a macrogeometria, conexão protética e profundidade da inserção da plataforma protética, sob carregamento axial ou oblíquo. Foram criados três modelos de resina fotoelástica para cada tipo de implante avaliado (hexágono externo, hexágono externo wedge, hexágono interno e cone Morse). Cada corpo de prova se diferenciou pelo posicionamento da plataforma do implante em relação à margem superior do bloco, em três posições diferentes: I - plataforma posicionada 2mm abaixo da margem do bloco; II - plataforma posicionada no mesmo nível da margem do bloco; III - plataforma posicionada 2mm acima da margem do bloco. Foi aplicada uma força de 100N através de um dispositivo instalado sobre pilares retos e angulados, simulando um carregamento axial e oblíquo respectivamente. Um total de 4 pontos foram avaliados de um lado do implante. Dados quantitativos foram coletados e utilizados para análise estatística. A regressão linear múltipla mostrou relação entre a distribuição das tensões com relação à profundidade de inserção independentemente do tipo de conexão protética ou do carregamento oclusal. O grupo I (2mm abaixo da margem) foi o que apresentou os menores valores (p<0.05) de tensão quando comparado com os outros grupos (II e III). De acordo com as limitações deste estudo pode-se concluir que a macrogeometria, profundidade de inserção da plataforma e tipo de carregamento oclusal influenciam no comportamento da distribuição das tensões ao redor dos implantes. Em relação à conexão protética, os resultados mostraram padrões de franjas semelhantes independentemente do tipo de conexão / The progressive bone loss at the neck of dental implant is a clinical concern since it affects the maintenance of dental esthetics. The stress concentration, the connection type and the microgap appear to be factors that cause alterations at the marginal bone level. The aim of this research was to evaluate the stress concentration around different dental implants, varying the macrogeometry, prosthetic connection and depth of the insertion of the prosthetic platform, under axial or oblique loading. Three blocks of photoelastic resin for each type of implant connection (external hexagon, external hexagon flattened, internal hexagon and Morse taper) were built. Each block differed in the position of the implant platform in relative to the upper margin of the block: I (2mm below), II (at the same level) and III (2mm above). A force of 100N was applied to both a straight and tilted abutments. A multiple linear regression showed the relation between the stress distribution and the insertion depth. For all the implant types, both with straight and tilted abutments, Group I presented the lowest stress concentration around the fixture when compared to group II and III (p<0,05). According to the limitations of this study it could be concluded that the macrogeometry, depth of insertion of the platform and type of occlusal loading influence the behavior of the distribution of stresses around the implants. Regarding the prosthetic connection, the results showed similar patterns of fringes regardless of the type of connection
5

A utilização de um sistema de pontuação (IPB) na avaliação comparativa entre modelos de trabalho encaminhados, para confecção de próteses parciais removíveis / The use of a scoring system (IPB) in the comparative analysis of prosthesis models forwarded for manufacturing removable parcial dentures

Rocha, Mara Rejane Barreto Alves 24 September 2012 (has links)
Este estudo avaliou a qualidade dos preparos de boca para confecção de próteses parciais removíveis (PPRs), comparando os preparos realizados na graduação da Faculdade de Odontologia da Universidade de São Paulo (FOUSP), sob supervisão de Docentes, com os preparos realizados por cirurgiões dentistas que solicitaram a confecção dessas próteses a dois laboratórios de Prótese Dentária de São Paulo. As análises foram realizadas em 92 modelos de trabalho, divididos em dois grupos: grupo I, modelos obtidos de pacientes que foram reabilitados na Disciplina de Prótese Removível da FOUSP, por alunos de graduação, e grupo II, modelos obtidos de pacientes que foram reabilitados por vários profissionais, e que foram recolhidos dos referidos laboratórios. Foi utilizado como instrumento de avaliação, o Índice de Preparo de Boca modificado (IPB), com o objetivo de avaliar comparativamente, os dois grupos, quanto a Distribuição, Localização e Forma dos descansos oclusais e de cíngulo; Presença, Distribuição e Paralelismo dos planos-guia; Características dos pontos de calibragem; e a diferença estatística dos valores do IPB, entre os grupos. Ainda foi investigada a prevalência da classificação de Kennedy (para pacientes desdentados parciais), nos dois grupos de modelos. O método estatístico utilizado foi o teste não paramétrico de Mann-Whitney. Baseado nos resultados encontrados, concluiu-se que os preparos de boca dos trabalhos realizados na Faculdade de Odontologia da Universidade de São Paulo (grupo I, modelos-USP) foram significativamente melhores do que aqueles elaborados por profissionais, cirurgiões dentistas que enviaram os modelos de seus pacientes aos laboratórios, para confecção de PPRs (grupo II, modelos-Laboratórios). Não houve associação estatisticamente significante entre os grupos de modelos no que se refere à classificação de Kennedy. / This study analysed the quality of mouth preparations for manufacturing removable parcial dentures (RPDs) by comparing preparations made by undergraduates at Faculdade de Odontologia da Universidade de São Paulo (FOUSP) working under the supervision of staff teachers with preparations made by dentist surgeons who had sent prostheses to two dental prosthesis laboratories in São Paulo for manufacturing. Analyses were carried out in 92 models divided in two groups: group I, models obtained from patients rehabilitated by undergraduates in the subject Removable Prosthesis at FOUSP and group II, models obtained from patients rehabilitated by several professional dentist surgeons and collected at the two laboratories mentioned above. The instrument of assessment used was the modified Mouth Preparation Ratio (IPB), aiming at assessing the two groups comparatively concerning the Distribution, Location and shape of rest bite and cingulum occlusion, Presence, Distribution and Paralelism of guide planes; Characteristics of the calibration points; and the statistical difference in IPB values between the two model groups. The prevalence of the Kennedy classification (for parcially toothless patients) was also investigated in both model groups. The statitical method used in both groups was the Mann-Whitney non-parametric test. Based on the results achieved, it was concluded that mouth preparations made at Faculdade de Odontologia da Universidede de São Paulo (group I, USP models) were significantly better than those made by professional dentist surgeons who had sent their patients models to the dental laboratories for manufacturing RPDs (group II, lab models). There was no statistically significant association between both groups concerning the Kennedy classification.
6

A utilização de um sistema de pontuação (IPB) na avaliação comparativa entre modelos de trabalho encaminhados, para confecção de próteses parciais removíveis / The use of a scoring system (IPB) in the comparative analysis of prosthesis models forwarded for manufacturing removable parcial dentures

Mara Rejane Barreto Alves Rocha 24 September 2012 (has links)
Este estudo avaliou a qualidade dos preparos de boca para confecção de próteses parciais removíveis (PPRs), comparando os preparos realizados na graduação da Faculdade de Odontologia da Universidade de São Paulo (FOUSP), sob supervisão de Docentes, com os preparos realizados por cirurgiões dentistas que solicitaram a confecção dessas próteses a dois laboratórios de Prótese Dentária de São Paulo. As análises foram realizadas em 92 modelos de trabalho, divididos em dois grupos: grupo I, modelos obtidos de pacientes que foram reabilitados na Disciplina de Prótese Removível da FOUSP, por alunos de graduação, e grupo II, modelos obtidos de pacientes que foram reabilitados por vários profissionais, e que foram recolhidos dos referidos laboratórios. Foi utilizado como instrumento de avaliação, o Índice de Preparo de Boca modificado (IPB), com o objetivo de avaliar comparativamente, os dois grupos, quanto a Distribuição, Localização e Forma dos descansos oclusais e de cíngulo; Presença, Distribuição e Paralelismo dos planos-guia; Características dos pontos de calibragem; e a diferença estatística dos valores do IPB, entre os grupos. Ainda foi investigada a prevalência da classificação de Kennedy (para pacientes desdentados parciais), nos dois grupos de modelos. O método estatístico utilizado foi o teste não paramétrico de Mann-Whitney. Baseado nos resultados encontrados, concluiu-se que os preparos de boca dos trabalhos realizados na Faculdade de Odontologia da Universidade de São Paulo (grupo I, modelos-USP) foram significativamente melhores do que aqueles elaborados por profissionais, cirurgiões dentistas que enviaram os modelos de seus pacientes aos laboratórios, para confecção de PPRs (grupo II, modelos-Laboratórios). Não houve associação estatisticamente significante entre os grupos de modelos no que se refere à classificação de Kennedy. / This study analysed the quality of mouth preparations for manufacturing removable parcial dentures (RPDs) by comparing preparations made by undergraduates at Faculdade de Odontologia da Universidade de São Paulo (FOUSP) working under the supervision of staff teachers with preparations made by dentist surgeons who had sent prostheses to two dental prosthesis laboratories in São Paulo for manufacturing. Analyses were carried out in 92 models divided in two groups: group I, models obtained from patients rehabilitated by undergraduates in the subject Removable Prosthesis at FOUSP and group II, models obtained from patients rehabilitated by several professional dentist surgeons and collected at the two laboratories mentioned above. The instrument of assessment used was the modified Mouth Preparation Ratio (IPB), aiming at assessing the two groups comparatively concerning the Distribution, Location and shape of rest bite and cingulum occlusion, Presence, Distribution and Paralelism of guide planes; Characteristics of the calibration points; and the statistical difference in IPB values between the two model groups. The prevalence of the Kennedy classification (for parcially toothless patients) was also investigated in both model groups. The statitical method used in both groups was the Mann-Whitney non-parametric test. Based on the results achieved, it was concluded that mouth preparations made at Faculdade de Odontologia da Universidede de São Paulo (group I, USP models) were significantly better than those made by professional dentist surgeons who had sent their patients models to the dental laboratories for manufacturing RPDs (group II, lab models). There was no statistically significant association between both groups concerning the Kennedy classification.

Page generated in 0.1366 seconds