• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influencia de la distribución de amortiguadores de masa sintonizada ubicados en el último piso de una edificación de concreto armado de 5 niveles para la reducción de los efectos torsionales ante respuestas sísmicas mediante un análisis estructural en Lima, Perú

Barja Rosas, Xiomara Mariela, Sotomayor Cerron, Aldahir Edgar 27 October 2021 (has links)
En este trabajo se analizará el control de la respuesta sísmica de una edificación asimétrica de 5 pisos mediante la incorporación de Amortiguadores de Masa Sintonizada (AMS) evaluando distintas distribuciones de porcentaje de masa del dispositivo para obtener una óptima ubicación en la última planta con el objeto de reducir los efectos torsionales producto de las irregularidades de planta. Para el desarrollo se designaron diversas variables para caracterizar el comportamiento de cada modelo. Estudios anteriores optaban por considerar independientemente cada variable y globalizaban la respuesta de estas a el resto de las variables. A raíz de esto, se decide analizar paralelamente y comparar en cada modelo estructural hasta obtener una óptima distribución. / A viable option to reduce seismic vibrations in structures is the use of passive control devices, within which are the Tuned Mass Dampers (AMS). In an asymmetric construction a greater flexional and torsional vibration is produced, this phenomenon leads to an increase in the forces present in the sections and an eventual collapse of the structure. In this way, the implementation of the Tuned Mass Damper in an asymmetric building, allows to dissipate the energy product of horizontal movements such as the earthquake, besides attenuating the torsional effects due to the asymmetry. In this research thesis the control of the seismic response of an asymmetric 5-story building, structured on the basis of porticos and reinforced concrete walls, will be analyzed, by incorporating Tuned Mass Dampers evaluating different distributions to obtain the optimal location and distribution in the last floor in order to control the torsional effects product of plant irregularities. / Tesis

Page generated in 0.0824 seconds