Spelling suggestions: "subject:"polishing bonds"" "subject:"olishing bonds""
1 |
Avaliação do processo de remoção de fármacos e parabenos de esgoto doméstico em sistema de tratamento baseado em lagoas de lemnas / Evaluation of pharmaceutical and parabens removal process from domestic sewage in treatment system based on lemna pondAnjos, Mariane Luz dos [UNESP] 16 February 2017 (has links)
Submitted by MARIANE LUZ DOS ANJOS null (mluzanjos@bol.com.br) on 2017-03-08T23:18:04Z
No. of bitstreams: 1
Avaliação do processo de remoção de fármacos e parabenos de esgoto doméstico em sistema de tratamento baseado em lagoas de lemnas.pdf: 2472000 bytes, checksum: dda052a00851f9fefb87686b3c89414b (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-03-13T20:52:05Z (GMT) No. of bitstreams: 1
anjos_ml_me_ilha.pdf: 2472000 bytes, checksum: dda052a00851f9fefb87686b3c89414b (MD5) / Made available in DSpace on 2017-03-13T20:52:05Z (GMT). No. of bitstreams: 1
anjos_ml_me_ilha.pdf: 2472000 bytes, checksum: dda052a00851f9fefb87686b3c89414b (MD5)
Previous issue date: 2017-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A presença de fármacos e parabenos em esgoto doméstico é uma questão de grande preocupação devido seus efeitos negativos em ecossistemas e na saúde humana. Neste sentido a fitoremediação surge como sendo uma alternativa vantajosa de remoção dos micropoluentes, o baixo custo de implantação e manutenção é um fator atrativo. O presente estudo visa avaliar a capacidade de duas macrófitas aquáticas (Landoltia punctata e Lemna minor.), para remoção de fármacos (Diclofenaco e Naproxeno) e parabenos (Metil e Propil parabeno) do esgoto doméstico. Foram utilizados dois tanques de 3000 mil litros, sendo Tanque A composto por Landoltia punctata e Tanque B , Lemna minor, foram coletadas amostras a cada três dias durante 21 dias nos períodos diurno e vespertino. Os resultados de remoção para os fármacos do Tanque B, em média 0,63 g/L( remoção de 96.70% ) para diclofenaco e 30,60g/L para naproxeno (remoção de 49,29%) respectivamente, enquanto o Tanque A atingiu 3,42g/L para diclofenaco e (remoção de 80,4%) 34,47g/L para naproxeno (remoção de 36,85%). Os resultados para remoções de metilparabeno foi para tanque A (diurno e vespertino) foram de 14,36 e 14,78g/l, (remoção de 90,87% e 90,60%), enquanto o tanque B foi de 16,86 g/L para período diurno ( eficiência de 90,61%), 17,22g/L, e a sua (eficiência de 89,05%) durante o período vespertino. Para propil parabeno houve uma maior remoção para tanque B de 16,18 g/L para (PrPP), ( eficiência de 89,35%), enquanto que para o período vespertino as concentrações foram de 13,97g/L para (PrPP), (eficiência de 90,60%), para o tanque A as concentrações foram em média de saída foi de 59,52g/L para o propilparabeno, e para o período vespertino foi observado uma eficiência média de 73,73%, com uma concentração de 55,10 g/L de (PrPP).Esses resultados destacam a importância das lagoas de polimento de lemna para remoção de fármacos e parabenos. / The presence of pharmaceuticals and parabens in domestic wastewater is a question of great concern, due the negative effects on ecosystems and human health. The phytoremediation appears to be an advantageous alternative to removing the micropollutants, the low cost of implantation and maintenance is an attractive factor. The objective of this study was evaluate the capacity of two macrophytes (Landoltia punctata and Lemna minor), to remove pharmaceuticals (diclofenac and naproxen) and parabens (methyl and propyl paraben) of domestic wastewater. It were used two tanks ( 3000 liters each), tank A was composed with Landoltia punctata and tank B, Lemna minor, samples were collected every three days for 21 days, during the morning and evening periods. The results for the removal of the pharmaceuticals were achieved by tank B were 0.63 ug / L (96.70% removal) to diclofenac and 30,60g / L of naproxen (removal 49,29 %) respectively, while the tank A reached 3,42g / L diclofenac and (80.4% removal) 34,47g / L of naproxen (36.85% removal). The results achieved for removal of parabens higher for methylparaben to the tank A (morning and evening) were 14.36 and 14,78g / L (removal of 90.87% and 90.60%), while tank B was 16.86 ug / L for morning (90.61% efficiency), 17,22g / L, and its (89.05% efficiency) during the afternoon. While for propyl paraben there was a greater removal to tank B 16.18 ug / L (PRPP) (89.35% efficiency), whereas for the evening period concentrations were 13,97g / L for (PRPP), (90,60% efficiency) to the tank A the concentrations were in average of 59,52g / L propylparaben, and the evening period had an average efficiency 73.73%, with a concentration of 55.10 ug / L (PRPP) .These results emphasize the importance of lemna polishing ponds for removal of pharmaceuticals and parabens.
|
2 |
Avaliação do processo de remoção de fármacos e parabenos de esgoto doméstico em sistema de tratamento baseado em lagoas de lemnas /Anjos, Mariane Luz dos January 2017 (has links)
Orientador: Liliane Lazzari Albertin / Resumo: A presença de fármacos e parabenos em esgoto doméstico é uma questão de grande preocupação devido seus efeitos negativos em ecossistemas e na saúde humana. Neste sentido a fitoremediação surge como sendo uma alternativa vantajosa de remoção dos micropoluentes, o baixo custo de implantação e manutenção é um fator atrativo. O presente estudo visa avaliar a capacidade de duas macrófitas aquáticas (Landoltia punctata e Lemna minor.), para remoção de fármacos (Diclofenaco e Naproxeno) e parabenos (Metil e Propil parabeno) do esgoto doméstico. Foram utilizados dois tanques de 3000 mil litros, sendo Tanque A composto por Landoltia punctata e Tanque B , Lemna minor, foram coletadas amostras a cada três dias durante 21 dias nos períodos diurno e vespertino. Os resultados de remoção para os fármacos do Tanque B, em média 0,63 g/L( remoção de 96.70% ) para diclofenaco e 30,60g/L para naproxeno (remoção de 49,29%) respectivamente, enquanto o Tanque A atingiu 3,42g/L para diclofenaco e (remoção de 80,4%) 34,47g/L para naproxeno (remoção de 36,85%). Os resultados para remoções de metilparabeno foi para tanque A (diurno e vespertino) foram de 14,36 e 14,78g/l, (remoção de 90,87% e 90,60%), enquanto o tanque B foi de 16,86 g/L para período diurno ( eficiência de 90,61%), 17,22g/L, e a sua (eficiência de 89,05%) durante o período vespertino. Para propil parabeno houve uma maior remoção para tanque B de 16,18 g/L para (PrPP), ( eficiência de 89,35%), enquanto que para o período ves... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
|
3 |
Pós-tratamento de efluente anaeróbio em lagoa de polimentoSousa, Tales Abreu Tavares de 27 February 2015 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2016-03-03T13:32:02Z
No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
PDF - Tales Abreu Tavares de Sousa.pdf: 2232314 bytes, checksum: 8ae3f2a5b57f78464c1716047130f458 (MD5) / Made available in DSpace on 2016-03-03T13:32:02Z (GMT). No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
PDF - Tales Abreu Tavares de Sousa.pdf: 2232314 bytes, checksum: 8ae3f2a5b57f78464c1716047130f458 (MD5)
Previous issue date: 2015-02-27 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The domestic sewage treatment in UASBs reactors followed by polishing pond is
a sustainable alternative, especially to the northeast of Brazil. Therefore, the present study
applied polishing ponds as anaerobic effluent post-treatment. Two treatment systems were
constructed and operated: 1) compact station (UASB reactor with intermittent flow sand
filter) followed by two 0.18 m deep shallow polishing ponds; 2) UASB reactor followed by
two polishing ponds with different hydraulic systems (batch and continuous) and same depth
(0.60 m). At system 1, at experimental conditions, with low organic concentration (87
mgO2.L
-1
filtered COD and 49 mgSSV.L
-1
), high sunlight incidence (597 Wm
), high
temperature (20 to 30 ºC) and carbon dioxide biological consumption sufficient to raise the
average pH units; the pond 1, feed with the aerobic effluent from the compact system,
reached a 9.6 pH and provided an average removal of 86% of the total kjeldahl nitrogen, 82%
of total phosphorus and 88% ortho-phosphate and coliform less than 1000 UFC.100ml
meeting the requirements of WHO (2006) for unrestricted irrigation. Also at system 1, the
pond 2, feed with the anaerobic effluent from the compact system, reached a 8.6 pH and
removed 80% NTK-N, 53% of total phosphorus and 44% ortho-phosphate, but did not obtain
coliform final average less than 1000 UFC.100ml
-1
. Both the 0.60 m deep ponds, 9 days batch
and 12 days continuous hydraulic systems, achieved low nutrients removal and poor coliform
efficiency, 96,85 and 97,21 %, equivalent to only two log units. Also achieved a negligible
removal efficiency for both total phosphorus (efficiency <2%) and for ortho-phosphate
(efficiency <25%); the NTK-N removal, compared to the ponds of 0.18 m were inefficient
average values, 55% and 68% for PP3 and PP4 respectively. / O tratamento de esgotos domésticos em reatores UASBs seguido de lagoa de
polimento é uma alternativa sustentável, sobretudo para o nordeste do Brasil. Dessa forma, o
presente trabalho utilizou lagoas de polimento como pós-tratamento de efluente de reator
UASB. Foram construídos e operados dois sistemas de tratamento: 1) Estação compacta
(reator UASB com filtro de areia de fluxo intermitente) seguido de duas lagoas de polimento
rasas, com profundidade de 0,18 m; 2) Reator UASB seguido de duas lagoas de polimento,
com diferentes regimes hidráulicos (batelada e contínuo) e mesma profundidade (0,60 m). No
sistema 1, nas condições do experimento, com baixa concentração orgânica (83±25 mgO
de DQO filtrada e 49±6 mgSSV.L
-1
), alta incidência de luz solar (597 W.m
) temperatura
variando de 20 a 30 ºC, e consumo biológico de gás carbônico suficiente para elevar a média
das unidades de pH; a lagoa 1, alimentada pelo efluente aeróbio da estação compacta,
alcançou um pH 9,6 e garantiu remoção média de 86% de nitrogênio total kjeldahl, 82% de
fósforo total e 88% de ortofosfato e coliformes termotolerantes menor que 1000 UFC.100ml
atendendo a exigência da OMS (WHO, 2006) para irrigação irrestrita. Ainda no sistema 1, a
lagoa 2, alimentada pelo efluente anaeróbio da estação compacta rasa de polimento, alcançou
pH de 8,6 e removeu 80% de N-NTK, 53% de fósforo total e 44% de ortofosfato, e coliformes
termotolerantes maior que 1000 UFC.100ml
-1
. As lagoas 0,60 m de profundidade, operadas
em batelada e em fluxo contínuo, respectivamente com TDH de 9 e 12 dias, apresentaram
baixa remoção de nutrientes e pouca eficiência de remoção de coliformes, 96,85 e 97,21 %,
equivalentes apenas duas unidades logs. Apresentam também uma insignificante eficiência de
remoção, tanto para fósforo total (eficiência<2%) quanto para ortofosfato (eficiência < 25%),
e as remoções de N-NTK, quando comparadas com as lagoas de 0,18 m, são de valores
médios ineficientes, 55% e 68% para LP3 e LP4, respectivamente.
|
4 |
Tratamento de efluente anaeróbio em lagoas de polimento com alimentação contínua e bateladaPontes, Tatiana Gomes de 25 February 2016 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2016-05-12T12:58:24Z
No. of bitstreams: 1
PDF - Tatiana Gomes de Pontes.pdf: 2313753 bytes, checksum: 8db271a02b37c7328dd7cd2c48e554d5 (MD5) / Made available in DSpace on 2016-05-12T12:58:24Z (GMT). No. of bitstreams: 1
PDF - Tatiana Gomes de Pontes.pdf: 2313753 bytes, checksum: 8db271a02b37c7328dd7cd2c48e554d5 (MD5)
Previous issue date: 2016-02-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work represents the post-treatment of effluent reactor UASB in polishing ponds fed with continuous flow and batch investigating different depths, in two experimental phases. In the first phase of work, the experimental system consisted of four polishing ponds in which two were monitored with continuous feed (LC57 and LC45) and two with semi-continuous (LB57 and LB45) and its tributary coming from pond transshipment, both ponds LC57 and LB57 (57 cm deep), for the ponds LC45 and LB45 (45 cm deep) had HDT 12 days. In the second phase of the work experimental consisted of three ponds, which two were fed in single and HDT batch of 8 days (LBT45 and LB245) with its arising tributaries respectively, LT and TE2, and fed continuously with HDT 12 days (LC245), both ponds of the second phase had 45 cm deep. In the first phase, the efficiencies of removals nitrogen overall kjeldahl, nitrogen ammonia and fecal coliforms of pond LC45 were respectively 55%, 71% and 99.3%, higher removals of ponds LC57 (53%, 62% and 99 , 3%), LB57 (39%, 47% and 96.9%) and LB45 (35%, 49% and 97.2%). In the second phase, the ponds with feeding batch and HDT eight days did not differ significantly from the pond with feed continuous and HDT of 12 days, but stood out for the displayed efficiencies, particularly thermotolerant coliforms, in which the pond LBT45 -1 obtained 1E + 03 UFC.100mL meet the WHO requirements for irrigation unrestricted. The ponds fed batch satisfactory results, allowing treat a greater number of tributaries in less time. / Neste trabalho foi avaliado o pós-tratamento do efluente do reator UASB em lagoas de polimento alimentadas com fluxo contínuo e batelada, investigando diferentes profundidades, em duas fases experimentais. Na primeira fase do trabalho, o sistema experimental era constituído de quatro lagoas de polimento, na qual duas foram monitoradas com alimentação contínua (LC57 e LC45) e duas com alimentação semicontínua (LB57 e LB45), sendo seu afluente oriundo da lagoa de transbordo, tanto as lagoas LC57 e LB57 (57 cm de profundidade), quanto às lagoas LC45 e LB45 (45 cm de profundidade) tinham TDH de 12 dias. Na segunda fase o trabalho experimental era constituído por três lagoas, na qual duas eram alimentadas em bateladas e TDH de 8 dias (LBT45 e LB245), com seus afluentes advindos respectivamente, da LT e do TE2, e uma alimentada continuamente com TDH de 12 dias (LC245), ambas as lagoas da segunda fase tinham 45 cm de profundidade. Na primeira fase, as eficiências de remoções de nitrogênio total kjeldahl, nitrogênio amoniacal e coliformes termotolerantes da lagoa LC45 foram, respectivamente de 55%, 71% e 99,3%, superiores as remoções das lagoas LC57 (53%, 62% e 99,3%), LB57 (39%, 47% e 96,9%) e LB45 (35%, 49% e 97,2%). Na segunda fase, as lagoas com alimentação em batelada e TDH de oito dias não diferiram significativamente da lagoa com alimentação contínua e TDH de 12 dias, mas destacaram-se pelas eficiências apresentadas, sobretudo de coliformes termotolerante, no qual a lagoa LBT45 -1 obteve 1E+03 UFC.100mL atendendo as exigências da OMS para irrigação irrestrita. As lagoas alimentadas em batelada obtiveram resultados satisfatórios, permitindo tratar uma quantidade superior de afluentes em menos tempo.
|
Page generated in 0.0668 seconds