• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Performance evaluation of wet-cooling tower fills with computational fluid dynamics

Gudmundsson, Yngvi 03 1900 (has links)
Thesis (MScEng)--Stellenbosch University, 2012. / ENGLISH ABSTRACT: A wet-cooling tower fill performance evaluation model developed by Reuter is derived in Cartesian coordinates for a rectangular cooling tower and compared to cross- and counterflow Merkel, e-NTU and Poppe models. The models are compared by applying them to a range of experimental data measured in the cross- and counterflow wet-cooling tower test facility at Stellenbosch University. The Reuter model is found to effectively give the same results as the Poppe method for cross- and counterflow fill configuration as well as the Merkel and e-NTU method if the assumptions as made by Merkel are implemented. A second order upwind discretization method is applied to the Reuter model for increased accuracy and compared to solution methods generally used to solve cross- and counterflow Merkel and Poppe models. First order methods used to solve the Reuter model and crossflow Merkel and Poppe models are found to need cell sizes four times smaller than the second order method to obtain the same results. The Reuter model is successfully implemented in two- and three-dimensional ANSYS-Fluent® CFD models for under- and supersaturated air. Heat and mass transfer in the fill area is simulated with a user defined function that employs a second order upwind method. The two dimensional ANSYS-Fluent® model is verified by means of a programmed numerical model for crossflow, counterflow and cross-counterflow. / AFRIKAANSE OPSOMMING: ‘n Natkoeltoring model vir die evaluering van pakkings werkverrigting, wat deur Reuter ontwikkel is, word in Kartesiese koördinate afgelei vir ‘n reghoekige koeltoring en word vergelyk met kruis- en teenvloei Merkel, e-NTU en Poppe modelle. Die verskillende modelle word vergelyk deur hulle op ‘n reeks eksperimentele data toe te pas wat in die kruis- en teenvloei natkoeltoring toetsfasiliteit by die Universiteit van Stellenbosch gemeet is. Dit is bevind dat die Reuter model effektief dieselfde resultate gee as die Poppe model vir kruis- en teenvloei pakkingskonfigurasies sowel as die Merkel en e-NTU metode, indien dieselfde aannames wat deur Merkel gemaak is geїmplementeer word. ‘n Tweede orde “upwind” metode word op die Reuter model toegepas vir hoër akkuraatheid en word vergelyk met oplossingsmetodes wat gewoonlik gebruik word om kruis- en teenvloei Merkel en Poppe modelle op te los. Eerste orde metodes wat gebruik is om die Reuter model en kruisvloei Merkel en Poppe modelle op te los benodig rooster selle wat vier keer kleiner is as vir tweede orde metodes om dieselfde resultaat te verkry. Die Reuter model is suksesvol in twee- en driedimensionele ANSYS-Fluent® BVD (“CFD”) modelle geїmplementeer vir on- en oorversadigde lug. Warmte- en massaoordrag in die pakkingsgebied word gesimuleer mbv ‘n gebruiker gedefinieerde funksie (“user defined function”) wat van ‘n tweede orde numeriese metode gebruik maak. Die tweedimensionele ANSYS-Fluent® model word m.b.v. ‘n geprogrameerde numeriese model bevestig vir kruis-, teen- en kruis-teenvloei.

Page generated in 0.0509 seconds