• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do ciclo de vida e influência do tempo de vida útil dos postes de madeira e de concreto do sistema de distribuição de energia elétrica

Souza, Hugo Henrique de Simone 02 1900 (has links)
Submitted by LIVIA FREITAS (livia.freitas@ufba.br) on 2014-07-30T13:53:02Z No. of bitstreams: 1 Dissertação Hugo Henrique de Simone Souza.pdf: 3108075 bytes, checksum: 8f3f0130dc864d5a8f31ea12960018b4 (MD5) / Approved for entry into archive by LIVIA FREITAS (livia.freitas@ufba.br) on 2014-07-30T13:53:13Z (GMT) No. of bitstreams: 1 Dissertação Hugo Henrique de Simone Souza.pdf: 3108075 bytes, checksum: 8f3f0130dc864d5a8f31ea12960018b4 (MD5) / Made available in DSpace on 2014-07-30T13:53:13Z (GMT). No. of bitstreams: 1 Dissertação Hugo Henrique de Simone Souza.pdf: 3108075 bytes, checksum: 8f3f0130dc864d5a8f31ea12960018b4 (MD5) / É necessário quantificar os impactos ambientais de diversos produtos e serviços para comparar alternativas e escolher aquela menos prejudicial ao meio ambiente. Para isso, destaca-se o instrumento de Avaliação do Ciclo de Vida (ACV). O objetivo deste trabalho foi analisar os potenciais impactos ambientais dos postes de madeira e de concreto do sistema de distribuição de energia elétrica considerando a variação do tempo de vida útil que estas estruturas estão sujeitas. A estimativa do tempo de vida útil foi realizada pelo método fatorial, de modo que foram identificados diversos fatores com potencial de influenciar a durabilidade dos postes. A ACV foi aplicada a partir do software Simapro, considerando todo o ciclo de vida dos postes, desde a extração de matérias primas até a disposição final. Para o inventário do ciclo de vida, foram considerados dados primários e secundários. Foi realizada a avaliação de impactos ambientais a partir dos métodos CML 2001 e ReCiPe midpoint. O estudo contou com a análise de incerteza através do método de Monte Carlo. Basicamente, os postes de madeira apresentaram menor potencial de impacto ambiental em relação aos postes de concreto para as categorias de acidificação, eutrofização, aquecimento global, depleção abiótica, ocupação urbana da terra, ecotoxicidade marinha e de água doce. Já para as categorias de ecotoxicidade terrestre, toxicidade humana e ocupação agrícola da terra este quadro se inverte. Foi realizada uma análise de sensibilidade com o propósito de verificar possíveis reduções nos impactos ambientais. Essa pesquisa contribuiu para alertar que a definição do valor de vida útil para determinados produtos, como os postes, pode influenciar os resultados da ACV. Ainda, quanto maior o tempo de vida útil, menor deve ser a carga ambiental do produto, afinal menos recursos serão necessários para substituí-lo. Os postes para suporte de redes aéreas são amplamente utilizados em todo o mundo, portanto, qualquer redução dos impactos ambientais gerados por estas estruturas pode trazer benefícios globais.
2

Avaliação da durabilidade do concreto utilizado em postes em São Luís

Santos, Vito Assis Alencar dos 20 June 2016 (has links)
Submitted by Alison Vanceto (alison-vanceto@hotmail.com) on 2017-01-13T10:28:09Z No. of bitstreams: 1 TeseVAAS.pdf: 21831878 bytes, checksum: f3bdf9f99a849830dbfd42f7d8038e5b (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2017-01-17T13:19:14Z (GMT) No. of bitstreams: 1 TeseVAAS.pdf: 21831878 bytes, checksum: f3bdf9f99a849830dbfd42f7d8038e5b (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2017-01-17T13:19:23Z (GMT) No. of bitstreams: 1 TeseVAAS.pdf: 21831878 bytes, checksum: f3bdf9f99a849830dbfd42f7d8038e5b (MD5) / Made available in DSpace on 2017-01-17T13:19:33Z (GMT). No. of bitstreams: 1 TeseVAAS.pdf: 21831878 bytes, checksum: f3bdf9f99a849830dbfd42f7d8038e5b (MD5) Previous issue date: 2016-06-20 / Não recebi financiamento / Reinforced concrete structures built in coastal areas, such as electricity distribution poles, are constantly attacked by aggressive environmental agents. Rebar corrosion mechanism is a specific manifestation of electrochemical corrosion in an aqueous medium, thus the mechanism of corrosion of steel in concrete develops only in the presence of water or environment with high relative humidity (R.H.>60%). Chloride is known as one of the most aggressive environmental agents, causing rebar corrosion and consequent degradation of the concrete. Chlorides can reach the steel reinforcement through the pores network present in the concrete, if the device is close to marine atmosphere. The chloride content increases with time, and can attack the entire surface of the rebar, and may result in severe and dangerous corrosion velocity. Corrosion results in a decrease in rebar section and cracking of the concrete in parallel direction. The cracks occur because of corrosion products occupy more space than the original steel. In São Luis, concrete poles located on the coastal area has presented different types of pathology, mostly linked to performance of the chlorine ions. As a consequence, the life of these parts has reduced dramatically, generating maintenance costs. Therefore, this study intended to develop alternatives aimed at increasing the durability of reinforced concrete poles, by reducing the transfer of chlorides in their concrete cover, through variations in trace and concrete chemical composition, evaluating the influence of these parameters on its mechanical resistance. Therefore, many specimens were shaped with different compositions, using Type CPII E-32 Portland cement (compound slag) with water / cement ratio ranging between 0.4 and 0.5. Concrete mixtures containing silica fume (in order to reduce the capillary) and red mud additions (in order to protect the equipment by reducing the free chloride content) were also tested. Durability assessment of concrete was based on the results of its physical and mechanical characterization, on the electrical resistivity evaluation of concrete and rebar corrosion potential. Results show that silica fume and red mud addition reduces porosity and water absorption of concrete samples, as well increases mechanical strength, when compared to currently used concrete for poles manufacturing in São Luis. Additionally, it revealed a drastic reduction in rebar corrosivity when covered by concrete with these additions, tripling the life time of poles. / Estruturas de concreto armado construídas em regiões litorâneas, como postes de distribuição de energia elétrica, são, constantemente, atacadas por agentes ambientais agressivos. O mecanismo da corrosão da armadura é uma manifestação específica da corrosão eletroquímica em meio aquoso, daí o mecanismo da corrosão do aço, no concreto, só se desenvolver em presença de água ou ambiente com umidade relativa elevada (U.R. > 60%). O cloreto é conhecido como um dos mais agressivos dentre os agentes ambientais, causando, entre danos, corrosão da armadura de aço e consequente degradação do concreto. Os cloretos podem alcançar a armadura de aço através da rede de poros presente no concreto, caso o artefato esteja próximo a atmosfera marinha, tendo sua concentração aumentada em função do tempo, e pode atacar toda a superfície da armadura, podendo resultar em taxas de corrosão intensas e perigosas. A corrosão tem como consequência uma diminuição da seção de armadura e fissuração do concreto em direção paralela a esta, uma vez que os produtos da corrosão ocupam espaço maior que o aço original. Em São Luís, postes de concreto localizados na orla têm apresentado distintos tipos de patologia, em sua grande maioria ligadas a atuação dos íons cloro. Como consequencia, a vida útil destas peças tem reduzido drasticamente, gerando custos com manutenção. Por isso, o presente trabalho objetivou desenvolver alternativas visando incrementar a durabilidade de postes de concreto armado, com a redução da transferência de cloretos em seu cobrimento, variando o traço e a composição química do concreto, avaliando a influência destes parâmetros na resistência mecânica do material. Para tanto, foram moldados diversos corpos de prova (CPs), com diferentes composições, usando cimento Portland do tipo CPII-E 32 (composto com escória), com relação água/cimento variando entre 0,4 e 0,5. Traços de concreto contendo adições de sílica ativa (visando a redução da capilaridade) e de lama vermelha (no intuito de proteger a armadura pela redução do teor de cloretos livres) também foram testados. A avaliação do comportamento dos concretos se baseou em resultados de caracterização físico-mecânica do material, além da avaliação da resistividade elétrica do concreto e do potencial de corrosão da armadura. Os resultados obtidos mostram que a adição de sílica ativa e lama vermelha resultou na redução da porosidade e da absorção de água das amostras de concreto, bem como o incremento na resistência mecânica, quando comparados ao concreto utilizado atualmente na fabricação de postes em São Luís. Adicionalmente, evidenciou-se redução drástica na corrosibilidade de armaduras protegidas com concreto contendo estas adições, triplicando a vida útil das peças.

Page generated in 0.0663 seconds