• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de um equipamento para avaliação dos potenciais miogênicos evocados vestibulares de amplo controle dos parâmetros

Oliveira, Aline Cabral de January 2008 (has links)
Os potenciais miogênicos evocados vestibulares são reflexos vestíbulo-espinhais, de média latência, decorrentes da estimulação acústica da mácula sacular, com estímulos de alta intensidade. A atividade elétrica dos músculos do pescoço, em especial do músculo esternocleidomastoideo, é captada com o auxílio de eletrodos de superfície. Esse potencial verifica se o órgão vestibular é sensível ao som e se existem alterações na mácula sacular, no nervo vestibular inferior, nas vias eferentes descendentes ou mesmo nas terminações nervosas nos músculos. Atualmente, ainda não existe um instrumento específico para a avaliação dos potencias miogênicos evocados vestibulares, sendo a mesma realizada por meio de um equipamento desenvolvido para a captação de potenciais evocados auditivos, já disponível no mercado. Assim, as funções de amplificação, filtragem, estimulação, janela de captação, rejeição de artefatos e características de promediação, bem como o próprio software de gerenciamento, ficam muito a desejar para a nova função que lhe é atribuída. O presente trabalho, então, teve como objetivo desenvolver e testar um equipamento eficiente para a avaliação dos potenciais miogênicos evocados vestibulares, de amplo controle dos parâmetros do exame pelo pesquisador. Dessa maneira, foi elaborado um equipamento específico, capaz de gerar estímulos e registrar os reflexos vestíbulo-espinhais. Após a realização de testes preliminares e da caracterização do dispositivo, foi realizado teste-piloto com onze ouvintes normais, sendo seis mulheres e cinco homens. A partir de estímulos sonoros tone bursts de 10 ms (subida: 4 ms, platô: 2 ms, descida: 4 ms), freqüência de 500 Hz, apresentados na taxa de 5 Hz, com intensidade de 90 dBNAn, foram registrados os potenciais miogênicos evocados com janelas de 80 ms. O exame era finalizado após promediação de 200 estímulos. Esse teste foi conduzido com o equipamento desenvolvido e com outro considerado padrão-ouro. As respostas foram analisadas por meio da morfologia, demarcando-se as ondas n13 e p23 pelas latências dos primeiros picos negativo e positivo. Em seguida, foi obtido o índice de assimetria e os resultados comparados entre os dois aparelhos. Aplicando-se o teste de Wilcoxon, pode-se constatar ausência de diferenças estatisticamente significativas, quando comparadas as respostas dos dois instrumentos, quanto aos parâmetros de latência e amplitude dos componentes n13 e p23, exceto para a latência de p23, com valor de p = 0,005. Pode-se observar maiores valores de assimetria para o aparelho EP25 que para o novo instrumento, no que se refere a componente n13. Quanto a componente p23, esses índices foram maiores na evocação pelo novo equipamento, entretanto o teste Qui-quadrado revelou que não existem diferenças estatisticamente significativas (valores de p= 0,14 e 0,60) para as amplitudes de n13 e p23, respectivamente. O valor do índice de assimetria inter-pico n13-p23, para o novo aparelho (2,10%), foi significativamente menor que o encontrado para o EP25 (30,55%), com p menor que 0,01. Dessa forma, conclui-se que não existem diferenças para as latências e amplitudes do VEMP entre o EP25 e o novo dispositivo desenvolvido, apresentando, esse último, maior proximidade com os valores descritos na literatura e menor índice de assimetria da amplitude interpico n13-p23. _________________________________________________________________________________________ ABSTRACT: The vestibular evoked myogenic potentials are a sacullo-colic reflexes, of middle latency, resulting from sacullo´s acoustic high intensity stimulation. The electromyographic activity of the neck muscles, especially the sternocleidomastoid muscle, is captured with surface electrodes. This potential assess both if the vestibular organ is hypersensitive to sound and if there are alterations in the sacullo (either on the vestibular nerve or on the vestibular nucleus). To date, however, there is no specific device for the assessment of vestibular evoked myogenic potentials. The evaluation of these potentials is currently conducted through an device developed for capturing auditory evoked potentials that is already available in the market. Nevertheless, the use of a non-specific, adapted device means that several important measures such as the function of amplification, filtering, stimulation, windowed, artifacts rejection, and averaging cues are not fully reached. The aim of this paper was to develop and test an efficient device for the assessment of the vestibular evoked myogenic potencials, with a broad control of the examination parameters by the researcher. Thus, a specific device to generate stimuli and register the reflexes vestibule-neck match was developed. After preliminary tests and the characterization of the device, pilot-tests were conducted with eleven normallisteners, six women and five men. From sound stimuli-tone bursts of 10 ms (rise: 4 ms, plateau: 2 ms, fall: 4 ms), frequency of 500 Hz, presented in 5 Hz rate, with 90 dB HLn of intensity, were recorded 80 ms window of vestibular evoked myogenic potencials. The examination was completed after 200 averages. This test was carried out using both the new device and another considered as the gold-standard (EP25). The responses were analyzed by morphology, observing the waves n13 and p23 latencies firsts peaks. The asymmetry index was then obtained, and the overall results compared between the two devices. Applying the Wilcoxon test, no significant differences were found between the two devices regarding the latency and amplitude parameters for the n13 and p23 components; the only significant (p = 0.0005) difference was for for the onset of p23. Higher values of asymmetry for the n13 component were observed for the EP25 when compared with the new instrument, while these indices were higher in the evocation by the new device. However, the Chi-square test showed no significant differences (p = 0.14 and 0.60 for the amplitudes of n13 and p23, respectively). The value of the n13-p23 inter-peak asymmetry index, for the new unit (2.10%) was significantly (p < 0.01) lower than that found for the EP25 unit (30.55%). Thus, it can be concluded that there were no differences for the VEMP latencies and amplitudes between the EP25 unit and the new device developed. In fact, the new device had stronger correlations with the values described in the literature and lower n13 - p23 inter-peak amplitude asymmetry index.
2

Estudo dos potenciais evocados miogênicos vestibulares de estado estável / Study of vestibular evoked myogenic potentials of steady state

Oliveira, Aline Cabral de January 2010 (has links)
A avaliação do potencial evocado miogênico vestibular é realizada por meio da captação de um potencial eletromiográfico, no domínio do tempo, decorrente da estimulação acústica da mácula sacular. Um método promissor, utilizado em outros tipos de potenciais evocados, possibilita a análise dos potenciais no domínio das frequências. A técnica de estado estável, como é conhecida, viabiliza a realização do exame com diferentes tipos de estímulos, simultaneamente, e a análise de cada uma das respostas em separado. O presente estudo teve como objetivo utilizar a técnica de estado estável para a obtenção de potenciais evocados miogênicos vestibulares, comparando a presença de respostas nos exames desses potenciais no domínio do tempo, com as obtidas nos exames, no domínio das frequências. Desse modo, captou-se o potencial evocado miogênico vestibular, no domínio do tempo, em 156 orelhas (78 adultos jovens com audição normal) nas frequências de 250, 500, 1000 e 2000 Hz e seguiu-se com a captação do potencial evocado miogênico de estado estável nessas mesmas frequências portadoras (escolhida uma frequência para cada indivíduo), moduladas em 20, 37, 40, 43, 70, 77 e 80 Hz. Na captação do exame no tempo, observou-se presença de onda em 150 dos 156 exames realizados (96,15%). As respostas encontradas, por frequência modulada, independente da portadora, registraram maiores presenças de picos e amplitudes médias para frequências menores que 43 Hz. A avaliação das respostas, por frequência portadora até 1.000 Hz, teve maior eficiência nas moduladoras de 37, 40 e 43 Hz, com odds ratio maior que 6,9. Para a portadora de 500 Hz, modulada a 20 Hz, entretanto, a resposta também esteve presente de maneira significativa e o valor do odds ratio igual a 11,5. Em 2.000 Hz, as respostas só foram observadas adequadamente em 37 e 40 Hz, porém com índices baixos de igualdade com as respostas do domínio do tempo (63,3 %). O potencial evocado miogênico vestibular de estado estável possui forte associação com o VEMP no domínio do tempo, sendo as respostas mais adequadas entre 37 e 43 Hz, independente da frequência portadora. _________________________________________________________________________________________ ABSTRACT: The evaluation of vestibular evoked myogenic potential is done by the collect of an eletromiogenic potential, within a certain time, originated from an acoustic stimulation of the saculus. A promising method, used in other kinds of evoked potential, allows an analysis of potentials according to the frequencies.The steady state technique, as we know, allows the execution of this test with different kinds of stimulus, simultaneously, and the analysis of each response separately. This present study aimed using the steady state technique to obtain the vestibular evoked myogenic potentials, comparing the presence of responses in these potentials tests within the time, with the ones obtained according to the frequencies. So, the vestibular evoked myogenic potentials were collected, within the time, in 156 ears (78 subjects) in the frequencies of 250, 500, 1000 and 2000 Hz and after that these potentials were collected in these same frequencies (chosen one frequency for each subject), but the frequencies were modulated in 20, 37, 40, 43, 70, 77 and 80 Hz. In the collection of the responses within the time, it was observed the presence of wave in 150 of the 156 ears tested (96,15%). The found responses, according to the modulated frequencies, independently of which one was, showed more presences of picks and medium amplitudes for frequencies under 43 Hz. In the collection of the responses within the time, it was observed the presence of wave in 150 of the 156 ears tested (96,15%). The found responses, according to the modulated frequencies, independently of which one was, showed more presences of picks and medium amplitudes for frequencies under 43 Hz. In 2000 Hz, the responses were just observed adequately in 37 and 40 Hz, however in low rates of equality with the responses according the time. (36,3%). The vestibular evoked myogenic potentials of steady state has a strong association with VEMP within the time, and more adequate responses are between 37 and 43 Hz, independently of the frequency.

Page generated in 0.0982 seconds