• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 180
  • 75
  • 42
  • 19
  • 15
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 495
  • 495
  • 254
  • 104
  • 102
  • 96
  • 90
  • 82
  • 79
  • 73
  • 72
  • 60
  • 60
  • 59
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Étude de l'influence des caractéristiques des isolateurs sur leurs performances électriques dans des conditions de givrage /

Chaarani, Rabah, January 2003 (has links)
Thèse (D.Eng.) -- Université du Québec à Chicoutimi, 2003. / Bibliogr.: f. [145]-152. Document électronique également accessible en format PDF. CaQCU
372

Dynamic modeling of AC arc development on ice surfaces = Modélisation dynamique du développement de l'arc électrique à la surface de la glace en courant alternatif /

Tavakoli Zaniani, Changiz, January 2004 (has links)
Thèse (D.Eng.) -- Université du Québec à Chicoutimi, 2004. / Bibliogr.: f. [183]-197. Document électronique également accessible en format PDF. CaQCU
373

Active power line conditioner with neural network control

Chen, Yaow-Ming, January 1997 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 1997. / Typescript. Vita. Includes bibliographical references (leaves 76-80). Also available on the Internet.
374

Transformerless series dip/sag compensation with a multilevel cascaded inverter

Visser, Abraham Johannes 12 1900 (has links)
Thesis (MScEng)--University of Stellenbosch, 2001. / ENGLISH ABSTRACT: This thesis covers the development of a multilevel cascaded inverter for the purpose of costeffective transformerless series dip compensation. Of all known power quality problems, voltage dips are the greatest reason for concern. Dips/sags occur more frequently than outages and therefore tend to be more costly for industry as modem technical equipment becomes all the more sensitive to the quality and reliability of supply. A number of devices already exist to compensate for this problem, but the cost of most of these systems does not always justify the financial losses they compensate for. All of these systems are using transformers and/or large filter components that contribute to the size, price and losses to quite a large extent. Series injection dip compensators offer the advantage of only having to compensate for the decrease in supply voltage during a dip. This results in a significant reduction in the converter ratings and energy storage requirements compared to conventional uninterruptible power supplies or shunt injection power quality devices. Existing inverter topologies, including multilevel inverters, were therefore studied and compared as possible solutions for cost-effective transformerless series dip compensation. On the basis of these considerations the multilevel cascaded inverter seems to be the most cost-effective option. The relatively low harmonic content of its unfiltered output also eliminates the need for a large output filter. A single-phase dip compensator, with this topology, was designed and built according to specifications stated by Eskom, the main utility in South Africa. Batteries as energy storage and automotive MOSFETs as switching components, proved to be most cost-effective options for the specified power ratings. Control algorithms for dip compensation with the multilevel inverter were also developed. Some of these algorithms are based on existing techniques, but two new algorithms were also developed to implement force commutation of the thyristors and to share the power dissipation in the dip compensator. Simulations indicated that these algorithms could be suitable and sufficient for their application. This dip compensator with its control algorithms was tested with a dip generator, developed at the University of Stellenbosch, for different types of loads. The experimental results confirmed the simulations and showed a very good performance for the specified conditions. An optimised design of this dip compensator will make it a cost-effective solution for dip compensation. / AFRIKAANSE OPSOMMING: Hierdie tesis dek die ontwikkeling van 'n multivlakwisselrigter, in kaskade, met koste-effektiewe transformatorlose duik kompensasie as mikpunt. Van al die bekende toevoerkwaliteit probleme wek duike in die spanning die meeste kommer. Duike kom meer gereeld voor as kragonderbrekings en neig daarom om 'n groter onkoste te wees vir die industrie soos wat moderne tegnologiese toerusting al hoe meer sensitief raak vir die kwaliteit en betroubaarheid van die toevoer. 'n Aantal toestelle wat vir hierdie probleem kompenseer bestaan reeds, maar die koste van hierdie stelsels regverdig nie altyd die finansiële verliese wat hulle moet elimineer nie. Al hierdie stelsels gebruik transformators en/of groot filter komponente wat grootliks bydra tot die grootte, prys en verliese van hierdie stelsels. Serie-injeksie kompenseerders het die voordeel dat hulle net kompenseer vir die verlies in die toevoerspanning tydens die duik. Dit het 'n beduidende vermindering in die omsetterkenwaardes en energiestoorvereistes tot gevolg in vergelyking met ononderbroke kragbronne (UPS) of newe-injeksie toevoerkwaliteit toestelle. Daarom IS bestaande wisselrigtertopologië, insluitende multivlakwisselrigters, bestudeer en vergelyk as moontlike oplossings vir koste-effektiewe serie duik-kompensasie. Van al hierdie moontlikhede lyk die multivlakwisselrigter, in kaskade, na die mees koste-effektiewe opsie. Die relatiewe lae harmoniese inhoud van sy ongefilterde uittree elimineer die behoefte aan 'n groot uittreefilter. 'n Enkelfase duik kompenseerder, met hierdie topologie, is ontwerp en gebou volgens die spesifikasies wat vasgestel is deur Eskom, die hoof elektriese kragvoorsiener in Suid-Afrika. Dit het geblyk dat batterye, en MOSFETte uit die motorbedryf, die mees koste-effektiewe opsies bied vir onderskeidelik die energiestoor en skakelkomponente. Beheeralgoritmes VIr duik kompensasie met die multivlakwisselrigter is ook ontwikkel. Sommige van hierdie algoritmes is gebaseer op bestaande tegnieke, maar twee nuwe algoritmes is ook ontwikkel vir die kommutering van die tiristors en die deling van die drywingsverkwisting in die duik kompenseerder. Simulasies dui aan dat hierdie algoritmes geskik en voldoende kan wees vir hulle toepassing. Hierdie duik kompenseerder met sy beheeralgoritmes is getoets vir verskillende tipes laste met 'n duikgenerator wat ontwikkel is by die Universiteit van Stellenbosch. Die eksperimentele resultate bevestig dit wat verkry is uit die simulasies en wys 'n goeie werkverrigting vir die gespesifiseerde kondisies. 'n Geoptimeerde ontwerp van hierdie duik kompenseerder sal dit 'n koste-effektiewe oplossing maak vir duik kompensasie.
375

Análise comparativa entre respostas de torre de transmissão sujeita a carregamentos obtidos através do método do vento sintético e da norma NBR 6123/88

Leite, Emerson Batista 24 April 2015 (has links)
Há diversos procedimentos para determinação dos carregamentos de vento. A norma NBR 6123/88 pode ser utilizada para determinação desses carregamentos e consequentes esforços para dimensionamento de estruturas. Entretanto há procedimentos não normativos que podem contribuir para determinação desses mesmos carregamentos. Um deles, que é empregado no presente trabalho, é o método do vento sintético. O objetivo desse trabalho é o de fazer uma análise comparativa entre as respostas obtidas na estrutura sujeita aos carregamentos dinâmicos, obtidos através do método do vento sintético, e as respostas obtidas com carregamentos estáticos gerados a partir de considerações da norma NBR 6123/88 – Forças devidas ao vento em edificações. A estrutura em estudo é uma torre de transmissão de energia elétrica, que é modelada no programa computacional RSTAB da Dlubal (DLUBAL, 2015), para determinação de suas características dinâmicas. Os carregamentos dinâmicos do vento para o método do vento sintético são gerados através de um algoritmo, utilizando-se do programa computacional Mathcad Prime, versão 3.0. Os carregamentos estáticos e dinâmicos são lançados na estrutura para determinação de deslocamentos, esforços internos axiais e reações de apoio. Os resultados comparados demonstram que a abordagem que considera carregamentos gerados a partir da NBR 6123/88 é a mais conservadora, com valores de grandezas que excedem em até 132% valores obtidos a partir do método do vento sintético. / There are several procedures to determine the wind loadings. The Brazilian code NBR 6123/88 can be used to determine these loadings and the internal forces for structural design. However, there are non-normative procedures that may contribute to determining those same loads. One of them, which is used in this work, is the method of synthetic wind. The aim of this study is to make a comparative analysis of the responses obtained for the structure when subjected to dynamic loads, obtained through the synthetic wind method, and the responses obtained with static loads generated from considerations of NBR 6123/88 - Forces due to the wind on buildings. The structure under study is a power transmission tower, which is modeled in the software program RSTAB, developed by Dlubal, to determine its dynamic characteristics. Using the software Mathcad Prime 3.0 the dynamic wind loads are generated by an algorithm for the wind synthetic method. Static and dynamic loads are applied to in the structure to determine displacements, axial internal forces and support reactions. The compared results show that the approach that considers loadings generated from the NBR 6123/88 is the most conservative, with magnitude values that exceed up to 132% values obtained from the synthetic wind method.
376

An analysis and improvement of selected features of power quality of grid-tied alternative energy systems

Gupta, Gunjan January 2018 (has links)
Thesis (PhD (Electrical Engineering))--Cape Peninsula University of Technology, 2018. / Electrical energy can be easily used and converted to other forms of energy for various applications. Technological advancement increases the dependency on electricity to a great extent. Various internal and external factors are responsible for the bad quality of power in power systems. The performance of the system is greatly affected by the presence of harmonics, as well as voltage and frequency variations, which leads to the malfunctioning of the device and decline of power quality and supply at load side. The reactive power compensation is carried out for better power quality. The literature survey is done to find the best and efficient scheme for reactive power compensation and mitigation of various power quality problems. The devices which are used to measure various power quality factors are discussed. Various mitigating schemes are surveyed in order to compensate reactive power and to improve the power quality at the distribution end. The integration of the most widely used renewable energy, wind energy in the distribution system creates technical issues like stability of the grid, harmonic distortion, voltage regulation, active and reactive power compensation etc. which are restricted to IEC and IEEE standards. One of the topics this thesis addresses is regulation in the reactive power generated along with voltage regulation by using an effective power electronics device known as a STATCOM. The main power quality factors like overvoltage and voltage flickers are mitigated by establishing STATCOMs in small wind farms. The wind farms are equipped with three wind turbines. These three wind turbines found in the wind farm can be operated together or one after another with an introduced delay. A glitch in even a little piece of a power grid can result in loss of efficiency, income and at times even life. In this manner, it is basic to outline a system which can distinguish the faults of the power system and take a faster response to recover it back to required reactive power. Two devices STATCOM and D-STATCOM are used for this purpose in this thesis. The D-STATCOM circuit and operating principle are also discussed in thesis. Different topologies of D-STATCOM discussed with their benefits and shortcomings. The voltage, current and hybrid technologies of D-STATCOM are also discussed.
377

An evaluation of development-induced relocation process in the Ingquza Hill Local Municipality

Makhanya, Kentridge Khanyile 11 1900 (has links)
The development of the Eros-Vuyani-Neptune 400 kV transmission powerline has seen some of the people of Ingquza Hill Local Municipality in the Eastern Cape relocated from their original place of residence. This research evaluated the process that was implemented when relocating the affected people in the Ingquza Hill Local Municipality, covering villages within Lusikisiki and Flagstaff towns. This study provides a response to the research question, which was: “Did the relocations improve the socio-economic and environmental sustainability of the people in Ingquza Hill Local Municipality?” The evaluation process of the study followed a systematic methodology, which entailed i) investigating and analysing the social impact indicators identified during the relocations; ii) evaluating and comparing key socio-economic and environmental indicators in Ingquza Hill Local Municipality; and iii) making recommendations to improve the relocation process. The study also formulated five key indicators of relocations, utilised to compare the social receptors before and after the relocation phase of the project. The utilised key indicators are: 1) quality education; 2) quality health care; 3) affected age groups; 4) community linkage; and 5) employment conditions. The results of the research highlighted the need for a comprehensive and, most importantly, inclusive process when relocating people from their homes. This research concluded that the relocation process needs to be formalised and adopted hand in hand with development instead of being treated as a separate process. The research study further recommends that the process of relocating communities, as a companion of development, needs to be effectively monitored and managed in order to curb the socio-environmental impacts thereof. / Environmental Science / M. Sc. (Environmental Management)
378

An Online Monitoring and Fault Location Methodology for Underground Power Cables

January 2016 (has links)
abstract: With the growing importance of underground power systems and the need for greater reliability of the power supply, cable monitoring and accurate fault location detection has become an increasingly important issue. The presence of inherent random fluctuations in power system signals can be used to extract valuable information about the condition of system equipment. One such component is the power cable, which is the primary focus of this research. This thesis investigates a unique methodology that allows online monitoring of an underground power cable. The methodology analyzes conventional power signals in the frequency domain to monitor the condition of a power cable. First, the proposed approach is analyzed theoretically with the help of mathematical computations. Frequency domain analysis techniques are then used to compute the power spectral density (PSD) of the system signals. The importance of inherent noise in the system, a key requirement of this methodology, is also explained. The behavior of resonant frequencies, which are unique to every system, are then analyzed under different system conditions with the help of mathematical expressions. Another important aspect of this methodology is its ability to accurately estimate cable fault location. The process is online and hence does not require the system to be disconnected from the grid. A single line to ground fault case is considered and the trend followed by the resonant frequencies for different fault positions is observed. The approach is initially explained using theoretical calculations followed by simulations in MATLAB/Simulink. The validity of this technique is proved by comparing the results obtained from theory and simulation to actual measurement data. / Dissertation/Thesis / Masters Thesis Electrical Engineering 2016
379

Obtenção de fios em ligas de cobre para utilização em linhas de transmissão e em eletrodos para contatos elétricos / Obtation of cooper-chromium-zirconium alloy wires for use in electrical transmission lines and electrodes for electrical contacts

SAFRA, LEANDRO C.P.G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:12Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:46Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
380

Development and assessment of reduced order power system models

Nteka, Makhetsi Flora January 2013 (has links)
Thesis submitted in fulfilment of the requirements for the degree Master of Technology: Electrical Engineering in the Faculty of Engineering at the Cape Peninsula University of Technology 2013 / The demand for electrical energy has kept on increasing, thus causing power systems to be more complex and bringing the challenging problems of electrical energy generation, transmission, stability, as well as storage to be examined more thoroughly. With the advent of high-speed computation and the desire to analyze increasingly complex behaviour in power systems, simulation techniques are gaining importance and prevalence. Nevertheless, while simulations of large, interconnected complex power systems are feasible, they remain time-consuming. Moreover, the models and parameters used in simulations are uncertain, due to measurement uncertainty, the need to represent a complex behaviour with low-order models, and the inherent changing nature of the power system. This research explores the use of a model reduction technique and the applications of a Real-Time Digital Simulator (RTDS) to reduce the uncertainty in large-scale complex power system models. The main goal of the research is to develop a reduced order model and to investigate the applications of the RTDS simulator in reduction of large, interconnected power systems models. The first stage of the study is to build and simulate the full model of the power system using the DigSILENT and RTDS simulators. The second phase is to apply model reduction technique to the full model and to determine the parameters in the reduced-order model as well as how the process of reduction increases this model uncertainty. In the third phase the results of the model reduction technique are compared based on the results of the original model - IEEE standard benchmark models has been used. The RTDS was used for comparative purposes. The thesis investigations use a particular model reduction technique as Coherency based Method. Though the method ideas are applicable more generally, a concrete demonstration of its principles is instructive and necessary. Further, while this particular technique is not relevant to every system, it does apply to a broad class of systems and illustrates the salient features of the proposed methodology. The results of the thesis can be used in the development of reduced models of complex power systems, simulation in real-time during power system operation, education at universities, and research. Keywords: IEEE benchmark models, reduced models, Coherency based Method, DigSILENT, RTDS, model uncertainty, power system stability

Page generated in 0.0557 seconds