• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An Experimental Methodology for Evaluating Power Losses of Rolling Element Bearings Subjected to Combined Radial and Axial Loads

Vedera, Kevin G. 31 July 2018 (has links)
No description available.
2

Transmission error in spur gears : static and dynamic finite-element modeling and design optimization

Tharmakulasingam, Raul January 2010 (has links)
The gear noise problem that widely occurs in power transmission systems is typically characterised by one or more high amplitude acoustic signals. The noise originates from the vibration of the gear pair system caused by transmission error excitation that arises from tooth profile errors, misalignment and tooth deflections. This work aims to further research the effect of tooth profile modifications on the transmission error of gear pairs. A spur gear pair was modelled using finite elements, and the gear mesh was simulated and analysed under static conditions. The results obtained were used to study the effect of intentional tooth profile modifications on the transmission error of the gear pair. A detailed parametric study, involving development of an optimisation algorithm to design the tooth modifications, was performed to quantify the changes in the transmission error as a function of tooth profile modification parameters as compared to an unmodified gear pair baseline. The work also investigates the main differences between the static and dynamic transmission error generated during the meshing of a spur gear pair model. A combination of Finite-Element Analysis, hybrid numerical/analytical methodology and optimisation algorithms were used to scrutinise the dynamic behaviour of the gear pairs under various operating conditions.
3

Metodologia para a coordenação e seletividade da proteção direcional de sobrecorrente em sistemas de transmissão de energia elétrica / Methodology for the coordination and selectivity of directional overcurrent protection in electrical power transmission systems

Negrão, Danilo Luiz Alves 31 March 2015 (has links)
Este trabalho propõe uma nova metodologia para a solução do problema de coordenação de relés direcionais de sobrecorrente em sistemas de transmissão em malha. São utilizadas informações sobre a atuação do relé como dispositivo de proteção principal (ou retaguarda local no caso de se considerar o relé de distância) e também de sua atuação como proteção de retaguarda remota, fornecendo uma base mais sólida para definição dos ajustes. A partir de uma série de critérios determinados de acordo com a instalação, define-se uma área de ajuste do relé, diretamente sobre sua curva de atuação. Sobre esta área, aplica-se um método de otimização capaz de encontrar o melhor ajuste possível para o dispositivo em análise. A metodologia é aplicada sem a necessidade de uma análise topológica do sistema, sendo que as informações da localização do relé e sua integração com os outros dispositivos de proteção são resumidas durante o estudo de curto-circuito, que fornece os dados de entrada para a metodologia. O algoritmo resume os critérios de coordenação em pontos de referência, de modo que a análise é feita relé a relé, eliminando assim problemas comuns como o de tratamento de banco de dados e ganhando em agilidade e simplicidade no tratamento do problema. A resposta fornecida é bastante intuitiva, sendo fácil entender os resultados obtidos e quais seriam as implicações caso na prática sejam necessárias adequações à instalação. / This work proposes a new methodology to solve the problem of coordination of directional overcurrent relays in meshed transmission systems. Using information about the operation of the directional relay as primary protection (or local backup, in the case of considering the distance relay) and also its role as remote backup protection, the methodology provides a more solid basis for defining settings. Based on a series of criteria determined in accordance with the installation, an area of relay feasible settings is defined directly over their time-overcurrent curve. On this area, an optimization method is applied to find the best possible setting for the device under analysis. The method is applied without the need for topological analysis of the system, and the information of the relay location and its integration with other protective devices are summarized during the short circuit study, which provides the input data for the methodology. The algorithm summarizes the criteria of coordination in landmarks and the analysis is performed relay by relay, thus common problems are eliminated, such as database treatment, gaining agility and simplicity in treating the problem. The answer provided is extremely intuitive, making it easy to understand the results and what would be the implications in case of, in practice, be necessary to perform adjustments to fit with the installation.
4

Metodologia para a coordenação e seletividade da proteção direcional de sobrecorrente em sistemas de transmissão de energia elétrica / Methodology for the coordination and selectivity of directional overcurrent protection in electrical power transmission systems

Danilo Luiz Alves Negrão 31 March 2015 (has links)
Este trabalho propõe uma nova metodologia para a solução do problema de coordenação de relés direcionais de sobrecorrente em sistemas de transmissão em malha. São utilizadas informações sobre a atuação do relé como dispositivo de proteção principal (ou retaguarda local no caso de se considerar o relé de distância) e também de sua atuação como proteção de retaguarda remota, fornecendo uma base mais sólida para definição dos ajustes. A partir de uma série de critérios determinados de acordo com a instalação, define-se uma área de ajuste do relé, diretamente sobre sua curva de atuação. Sobre esta área, aplica-se um método de otimização capaz de encontrar o melhor ajuste possível para o dispositivo em análise. A metodologia é aplicada sem a necessidade de uma análise topológica do sistema, sendo que as informações da localização do relé e sua integração com os outros dispositivos de proteção são resumidas durante o estudo de curto-circuito, que fornece os dados de entrada para a metodologia. O algoritmo resume os critérios de coordenação em pontos de referência, de modo que a análise é feita relé a relé, eliminando assim problemas comuns como o de tratamento de banco de dados e ganhando em agilidade e simplicidade no tratamento do problema. A resposta fornecida é bastante intuitiva, sendo fácil entender os resultados obtidos e quais seriam as implicações caso na prática sejam necessárias adequações à instalação. / This work proposes a new methodology to solve the problem of coordination of directional overcurrent relays in meshed transmission systems. Using information about the operation of the directional relay as primary protection (or local backup, in the case of considering the distance relay) and also its role as remote backup protection, the methodology provides a more solid basis for defining settings. Based on a series of criteria determined in accordance with the installation, an area of relay feasible settings is defined directly over their time-overcurrent curve. On this area, an optimization method is applied to find the best possible setting for the device under analysis. The method is applied without the need for topological analysis of the system, and the information of the relay location and its integration with other protective devices are summarized during the short circuit study, which provides the input data for the methodology. The algorithm summarizes the criteria of coordination in landmarks and the analysis is performed relay by relay, thus common problems are eliminated, such as database treatment, gaining agility and simplicity in treating the problem. The answer provided is extremely intuitive, making it easy to understand the results and what would be the implications in case of, in practice, be necessary to perform adjustments to fit with the installation.
5

Intelligent Systems Applications For Improving Power Systems Security

Bhimasingu, Ravikumar 07 1900 (has links)
Electric power systems are among the most complex man made systems on the world. Most of the time, they operate under quasi-steady state. With the ever increasing load demand and the advent of the deregulated power market recently, the power systems are pushed more often to operate close to their design limits and with more uncertainty of the system operating mode. With the increasing complexity and more interconnected systems, power systems are operating closer to their performance limits. As a result, maintaining system security and facilitating efficient system operation have been challenging tasks. Transmission systems are considered the most vital components in power systems connecting both generating/substation and consumer areas with several interconnected networks. In the past, they were owned by regulated, vertically integrated utility companies. They have been designed and operated so that conditions in close proximity to security boundaries are not frequently encountered. However, in the new open access environment, operating conditions tend to be much closer to security boundaries, as transmission use is increasing in sudden and unpredictable directions. Transmission unbundling, coupled with other regulatory requirements, has made new transmission facility construction more difficult. Unfortunately these transmission lines are frequently subjected to a wide variety of faults. Thus, providing proper protective functions for them is essential. Generally the protection of Extra High Voltage (EHV) and Ultra High Voltage (UHV) transmission lines are carried out by the use of distance relays in view of the fact that they provide fast fault clearance and system coordination. Transmission line relaying involves detection, classification and location of transmission line faults. Fast detections of faults enable quick isolation of the faulty line from service and hence, protecting it from the harmful effects of fault. Classification of faults means identification of the type of fault and faulted line section, and this information is required for finding the fault location and assessing the extent of repair work to be carried out. Accurate fault location is necessary for facilitating quick repair and restoration of the line, to improve the reliability and availability of the power supply. Generally, the protection system using conventional distance relaying algorithm involves three zones. The first zone (Z1) of the relay is set to detect faults on 80%90% of the protected line without any intentional time delay. The second zone (Z2) is set to protect the remainder of the line plus an adequate margin. Second zone relays are time delayed for 1530 cycles to coordinate with relays at remote bus. The settings of the third zone (Z3) ideally will cover the protected line, plus all of the longest line leaving the remote station. Z3 of a distance relay is used to provide the remote backup protection in case of the failure of the primary protection. Since Z3 covers an adjacent line, a large infeed (outfeed) from the remote terminal causes the relay to underreach (overreach). Thus, a very large load at the remote terminal may cause distance relays to mal-operate. Settings for conventional distance relays are selected to avoid overreach/underreach operation under the worst case scenarios. Studies of significant power system disturbances reported by North American Electric Reliability Council (NERC) indicate that protective relays are involved, one way or another, in 75% of the major disturbances and the most troublesome ones are backup protection relays. With their limited view of the interconnected network based on their locally measured inputs, conventional backup protection relays generally take actions to protect a localized region of the network without considering the impact on the whole network. Relay mal-operations or unintended operations due to overload, power swing, and relay hidden failure are the main factors contributing to the blackouts. Most of the problems are associated with relays tripping too many healthy lines. Since a relay makes the decision automatically to remove a component from the system according to its internal mechanism, the relay mal-operation or unintended operation can make an effective influence on the system stability. Approaches to reduce the relay misbehavior need to be identified. Real time monitoring tools to assess the relay misbehavior are needed, providing the system operator, the accurate information about unfolding events. Existing transmission line protection scheme still has drawbacks. Advanced fault analysis mechanism to enhance the system dependability and security simultaneously is desirable. Relay settings play a significant role in major blackouts. So correct settings should be calculated and coordinated by suitable studies. Attempts are to be made to employ highly accurate AI techniques in protective system implementation. The research work focussed on developing knowledge based intelligent tools for the improving the transmission system security. A process to obtain knowledgebase using SVMs for ready post-fault diagnosis purpose is developed. SVMs are used as Intelligent tool for identifying the faulted line that is emanating from a substation and finding the distance from the substation. The approach uses phasor values of the line voltages and currents after the fault has been detected. The approach is particularly important for post-fault diagnosis of any mal-operation of relays following a disturbance in the neighboring line connected to the same substation. This may help in improving the fault monitoring/diagnosis process and coordination of the protective relays, thus assuring secure operation of the power systems. The approach based on SVMs, exploits the first part of this goal. For comparison, a classifier and regression tools based on the RBFNNs was also investigated. The RBFNNs and SVM networks are introduced and considered as an appropriate tool for pattern recognition problems. Results on a practical 24Bus equivalent EHV transmission system of Indian Southern region and on IEEE39 bus New England system are presented to illustrate the proposed method. In a large connected power network, the number of generators are more in number and their set patterns number will be large. As the line flows are sensitive to generator set patterns, it is difficult to consider all the combinations of generators while simulating the training and testing patterns as input to SVMs. To simulate the training and testing patterns corresponding to possible changes in line flows to meet the load in the present deregulated environment, line flow sensitive generators set to be identified/merit-listed. In this regard, to identify the most sensitive generators for a particular line of interest, a method from the literature is adopted and developed a software program based on the graph theory concepts. Case studies on generator contributions towards loads and transmission lines are illustrated on an equivalent 33bus system, a part of Indian Northern grid with major part of Uttar Pradesh and also with an equivalent 246bus system of practical Indian Southern grid. A distance relay coordination approach is proposed using detailed simulation studies, taking into account various operating conditions and fault resistances. Support Vector Machines as a pattern classifier is used for obtaining distance relay coordination. The scheme uses the apparent impedance values observed during fault as inputs. SVMs are used to build the underlying concept between reach of different zones and the impedance trajectory during fault. An improved performance with the use of SVMs, keeping the reach when faced with different fault conditions as well as line flow changes are illustrated with an equivalent 246bus system of practical Indian Southern grid and also with an equivalent 265bus system of practical Indian Western grid. A strategy of Supportive System is described to aid the conventional protection philosophy in combating situations where protection systems are mal-operated and/or information is missing and provide selective and secure coordination. Highly accurate identification/discrimination of zones plays a key role in effective implementation of the region-wide supportive system. This typically requires a multiclass SVM classifier to effectively analyze/build the underlying concept between reach of different zones and the apparent impedance trajectory during fault. Different multiclass methods are compared for their performance with respect to accuracy, number of iterations, number of support vectors, training and testing time. The performance analysis of these methods is presented on three data sets belonging to the training and testing patterns of three supportive systems for a region, part of a network, which is an equivalent 265bus system of practical Indian Western grid.

Page generated in 0.1059 seconds