• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 612
  • 473
  • 88
  • 26
  • 26
  • 26
  • 26
  • 26
  • 24
  • 19
  • 16
  • 13
  • 8
  • 8
  • 6
  • Tagged with
  • 1498
  • 1498
  • 826
  • 450
  • 267
  • 245
  • 244
  • 222
  • 209
  • 208
  • 190
  • 185
  • 183
  • 175
  • 134
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Modeling, prediction and mitigation of power distribution system voltage distortion caused by nonlinear loads

Wang, Yen-Ju, January 2000 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 2000. / Typescript. Vita. Includes bibliographical references (leaves 106-111). Also available on the Internet.
322

An enhanced graphical user interface for analyzing the vulnerability of electrical power systems to terrorist attacks /

Stathakos, Dimitrios. January 2003 (has links) (PDF)
Thesis (M.S. in Operations Research)--Naval Postgraduate School, December 2003. / Thesis advisor(s): Javier Salmeron, Kevin Wood. Includes bibliographical references (p. 101-102). Also available online.
323

Investigation or a pulsed plasma thruster plume using a quadruple Langmuir probe technique

Zwahlen, Jurg C. January 2003 (has links)
Thesis (M.S.)--Worcester Polytechnic Institute. / Keywords: Langmuir probes; spacecraft; electric propulsion. Includes bibliographical references (p.69-71).
324

Power system impacts of plug-in hybrid electric vehicles

Roe, Curtis Aaron. January 2009 (has links)
Thesis (M. S.)--Electrical and Computer Engineering, Georgia Institute of Technology, 2010. / Committee Chair: Dr. A. P. Meliopoulos; Committee Member: Dr. David Taylor; Committee Member: Dr. Ronald Harley; Committee Member: Dr. Shijie Deng. Part of the SMARTech Electronic Thesis and Dissertation Collection.
325

Distributed intelligent system for on-line fault section estimation of large-scale power networks /

Bi, Tianshu. January 2002 (has links)
Thesis (Ph. D.)--University of Hong Kong, 2002. / Includes bibliographical references (leaves 112-126).
326

Analysis and comparison of power loss and voltage drop of 15 kV and 20 kV medium voltage levels in the north substation of the Kabul power distrubution system by CYMDIST

Mehryoon, Shah M. January 2009 (has links)
Thesis (M.S.)--Ohio University, November, 2009. / Title from PDF t.p. Includes bibliographical references.
327

Sequential quadratic programming-based contingency constrained optimal power flow

Pajic, Slobodan. January 2003 (has links)
Thesis (M.S.)--Worcester Polytechnic Institute. / Keywords: contingency; interior point method; optimal power flow. Includes bibliographical references (p. 82-83).
328

Real-time application of synchronised phasor measurement units in power system small-signal stability analysis.

Ngoma, Louwrance Jack. January 2014 (has links)
M. Tech. Electrical Engineering. / Discusses that most real-time applications of synchronised phasor measurement units in power system stability studies are done using RTDS simulator, hardware PMUs and PTP hardware modules with GPS providing the time reference. The major drawbacks of this configuration are both technical and economical. The technical limitations are related to the possible number of outputs that can be used to interface PMU devices, which can be very limited; and also the possible limits on small-time step computation due to the big number of output signals. The economic constraints are mainly due to cost: for a research laboratory, only a limited number of units can be acquired due to budgeting issues. To overcome these difficulties, the realisation of an entirely software-based synchrophasor measurement unit, presents an attractive approach. Such a unit will be capable of deliveringreal-time data by acquiring the voltage and current signals from the Matlab/Simulink simulator, low cost software environment PMUs computing real-time phasors of voltage and current and software only PTP synchronisation protocol. The unit delivers synchrophasors for the application of power system SE and small signal stability analysis, but also taking into consideration the accuracy of the synchronisation protocol on the application of power system SE and small signal stability analysis.
329

Low Carbon Policy and Technology in the Power Sector: Evaluating Economic and Environmental Effects

Oates, David Luke 01 February 2015 (has links)
In this thesis, I present four research papers related by their focus on environmental and economic effects of low-carbon policies and technologies in electric power. The papers address a number of issues related to the operation and design of CCS-equipped plants with solvent storage and bypass, the effect of Renewable Portfolio Standards (RPS) on cycling of coal-fired power plants, and the EPA’s proposed CO2 emissions rule for existing power plants. In Chapter 2, I present results from a study of the design and operation of power plants equipped with CCS with flue gas bypass and solvent storage. I considered whether flue gas bypass and solvent storage could be used to increase the profitability of plants with CCS. Using a pricetaker profit maximization model, I evaluated the increase in NPV at a pulverized coal (PC) plant with an amine-based capture system, a PC plant with an ammonia-based capture system, and a natural gas combined-cycle plant with an amine-based capture system when these plants were equipped with an optimally sized solvent storage vessel and regenerator. I found that while flue gas bypass and solvent storage increased profitability at low CO2 prices, they ceased to do so at CO2 prices high enough for the overall plant to become NPV-positive. In Chapter 3, I present results from a Unit Commitment and Economic Dispatch model of the PJM West power system. I quantify the increase in cycling of coal-fired power plants that results when complying with a 20% RPS using wind power, accounting for cycling costs not usually included in power plant bids. I find that while additional cycling does increase cycling-related production costs and emissions of CO2, SO2, and NOX, these increases are small compared to the overall reductions in production costs and air emissions that occur with high levels of wind. In proposing its existing power plant CO2 emissions standard, the Environmental Protection Agency determined that significant energy efficiency would be available to aid in compliance. In Chapter 4, I use an expanded version of the model of Chapter 3 to evaluate compliance with the standard with and without this energy efficiency, as well as under several other scenarios. I find that emissions of CO2, SO2, and NOX are relatively insensitive to the amount of energy efficiency available, but that production costs increase significantly when complying without efficiency. In complying with the EPA’s proposed existing power plant CO2 emissions standard, states will have the choice of whether to comply individually or in cooperation with other states, as well as the choice of whether to comply with a rate-based standard or a mass-based standard. In Chapter 5, I present results from a linear dispatch model of the power system in the continental U.S. I find that cooperative compliance reduces total costs, but that certain states will prefer not to cooperate. I also find that compliance with a mass-based standard increases electricity prices by a larger margin than does compliance with a rate-based standard, with implications for the distribution of surplus changes between producers and consumers.
330

Multi-function monitoring system for harmonic and transient study of power networks

陳偉樂, Chan, Wai-lok. January 1992 (has links)
published_or_final_version / Electrical and Electronic Engineering / Master / Master of Philosophy

Page generated in 0.1945 seconds