• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 710
  • 37
  • 37
  • 37
  • 37
  • 28
  • 9
  • 8
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 728
  • 728
  • 357
  • 269
  • 232
  • 185
  • 141
  • 141
  • 123
  • 118
  • 107
  • 105
  • 89
  • 80
  • 77
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Discrepâncias de assentamento ocorrido em coroas totais metálicas, com e sem alívio interno, variando-se os términos cervicais e os agentes cimentantes

Figueiredo, Aldari Raimundo [UNESP] 27 June 1997 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:30Z (GMT). No. of bitstreams: 0 Previous issue date: 1997-06-27Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1 000126156.pdf: 4088167 bytes, checksum: 897cd22c86f9dc36f2eb1dddb6805462 (MD5) / Foi feita uma análise das discrepâncias de assentamento ocorridas na cimentação de coroas totais metálicas aliviadas ou não, internamente, sobre preparos com término cervical em chanfro; linha zero ou lâmina de faca; plano inclinado em 135°; ombro reto ou degrau em 90° e ombro reto ou degrau em 90°, associado a um bisel em 45°. Empregaram-se quatro tipos de cimentos, sendo três classificados como temporários à base de óxido de zinco e eugenol (Temp Bond e Provy) e outro sem eugenol (Temp Bond NE); e um quarto indicado para cimentações definitivas, cimento de Fosfato de Zinco. Idealizou-se modelos-padrão usinados em aço inoxidável, com características de um preparo para coroa total metálica em um primeiro molar inferior variando-se os términos cervicais conforme estabelecido. Foram obtidas cápsulas metálicas usinadas em aço inoxidável e perfeitamente adaptadas aos modelos-padrão com os términos cervicais correspondentes, nas condições de estarem aliviadas internamente ou não. Empregou-se uma técnica de cimentação padronizada para assentamento destas cápsulas metálicas nos modelos-padrão respectivos. Através de metodologia original promoveu-se a mensuração da discrepância de assentamento nos corpos-de-prova, com o aparelho Metroscópio Horizontal. Concluiu-se que: a) o alívio executado nas superfícies internas das coroas diminui de forma estatisticamente significante a discrepância marginal após a cimentação, independentemente do tipo de cimento empregado e da forma do término cervical adotada; b) o término cervical do preparo no modelo-padrão tipo Lâmina de Faca foi o que apresentou menor discrepância, independente do cimento empregado, seguido pelo Plano Inclinado, Chanfro, Ombro Biselado e Ombro Reto; c) os términos cervicais em Chanfro, Plano Inclinado e Lâmina de Faca, quando analisadas as amostras dos corpos-de-prova com alívio, .... / Seating discrepancies during cementation of complete metal crowns internally relieved or not with various finishing lines and cementing agents. This study evaluated the discrepancies during cementation of complete metal crowns either relieved or not on preparation with various margin designs: chamfer, knife edge, 135 degree shoulder, 90 degree shoulder, 90 degree shoulder with 45 degree bevel. Four types of cements, three temporary and one definitive were used: 1- zinc oxide and eugenol temporary cement (Temp Bond); 2- zinc oxide and eugenol temporary cement (Provy); 3- no eugenol temporary cement (Temp Bond NE) and 4- zinc phosphate cement (S.S.White). Machined stainless dies were fabricated to resemble complete crown preparations for a lower first molar with various finishing lines. Machined stainless steel copings, either internally relieved or not were also fabricated to fit the metal dies. A controlled technique was developed to assess seating discrepancies under the horizontal metroscope. Results showed: a) the internally relieved crowns showed after cementation statistically significant reduction of marginal discrepancies regardless of cement type or margin desing; b) knife edge finishing lines showed least dicrepancies regardless of cement type followed by the 135 degree shoulder, chamfer, bevelled 90 degree shoulder and 90 degree shoulder; c) internally relieved copings with chamfer, 135 degree shoulder and knife edge finishing lines showed no statiscally significant marginal discrepancies. This indicates that any of them yields favorable results; d) regarding cements, the least marginal discrepancies were found with Temp Bond NE followed by Temp Bond, Provy and finally by the Zinc Phosphate Cement (S.S.White)
102

Influência da adição de reforço e ciclagem mecânica na resistência ao impacto de resinas para base e para reembasamento imediato /

Perez, Luciano Elias da Cruz. January 2009 (has links)
Orientador: Ana Lúcia Machado / Coorientador: Sebastião Vicente Canevarolo Junior / Banca: Maria da Gloria Chiarello de Mattos / Banca: Sicknan Soares Rocha / Banca: Marco Antonio Compagnoni / Banca: Ana Claúdia Pavarina / Resumo: Este estudo avaliou o efeito da adição de reforço e ciclagem mecânica sobre a resistência ao impacto, por meio dos testes Charpy (C) e queda livre de dardo (QL), para resinas de base e para reembasamento imediato. Para o teste C, corpos-de-prova (60x6x2 mm) foram confeccionados com as resinas Lucitone 550 (L) e Vipi Wave (V) e reembasados (2 mm) com o mesmo material (L/L ou V/V) ou com as resinas para reembasamento imediato Tokuyama Rebase II (T) e Ufi Gel Hard (U). Corpos-de-prova puros de L, V, T e U (60x6x4 mm) também foram confeccionados para se determinar a resistência ao impacto dessas resinas. Para a avaliação da adição de reforço, foi adicionado ao pó das resinas reembasadoras 5%, em massa, do reforço de floco de vidro "glass flake" (UR, TR, L/UR, L/TR, V/UR, V/TR). 320 corpos-de-prova foram confeccionados, sendo 20 para cada condição experimental. Metade desses foi submetida à ciclagem mecânica (10.000 ciclos) com freqüência de 5 Hz (LC, VC, TC, UC, URC, TRC, L/URC, L/TRC, V/URC, V/TRC). Um entalhe, em forma de V foi realizado na largura, na superfície correspondente ao material reembasador, com profundidade de 0,8 mm, permanecendo 3,2 mm de material intacto. O teste foi realizado com pêndulo de 0,5 J e distância de 50 mm entre os suportes. Os resultados (kJ/ m2) foram analisados utilizando-se ANOVA e teste de Dunnet C (α = .05). Não houve diferenças estatisticamente significantes entre as médias de resistência ao impacto das condições L, L/L, V, V/V, LC, L/LC, VC e V/VC. As condições experimentais relativas às resinas autopolimerizáveis U, T, UC, TC, UR, TR e TRC foram estatisticamente iguais entre si. Além disso, URC também foi estatisticamente igual a U, T, UC, TC, TR e TRC, porém, maior do que UR. Não houve diferença significativa (P>.05) entre as médias de resistência ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of the addition reinforcement and cyclic loading on the resistance to impact of Charpy tests (C) and free falling-dart (FD) for the denture base resins and reline materials. To test the C, bars (60x6x2 mm) were prepared with the resins Lucitone 550 (L) and Vipi Wave (V) and relined (2 mm) with the same material (L / L or V / V) or with relining resins Tokuyama Rebase II (T) and UFI Gel Hard (U). Specimens pure of L, V, T and U (60x6x4 mm) were also made to determine the impact resistance of these resins. For the evaluation of the addition of reinforcement, was added to the powder of the relining resins 5% by weight of the glass flake "glass flake" (UR, TR, L / UR, L / TR, V / UR, V / TR). 320 specimens were made, 20 for each experimental condition. Half of these were subjected to cyclic loading (10,000 cycles) with a frequency of 5 Hz (LC, VC, TC, UC, URC, TRC, L / URC, L / TRC, V / URC, V / TRC). A notch in the form of V was carried out in width, the area corresponding to the relining material with depth of 0.8 mm, 3.2 mm of material remained intact. The test was conducted with pendulum of 0.5 J and 50 mm distance between the supports. The results (kJ/ m2) were analyzed using the ANOVA and Dunnet C test (α = .05). No significant differences were noted among the mean impact values of L, L / L, V, V / V, LC, L / LC, VC and V / VC. The experimental conditions for relining resins U, T, UC, TC, UR, TR and TRC were statistically equal between themselves. In addition, URC was statistically equal to U, T, UC, TC, TR and TRC, however, higher than UR. No significant differences were noted (P> .05) mong the mean impact values of L/ U, V/ U, L/ UC, V/ UC, L/URC and V/ URC. These conditions had values of resistance to impact significantly lower than those of the resin tested pure L and T (P <.05). There was... (Complete abstract click electronic access below) / Doutor
103

Avaliação da força mastigatória e da atividade eletromiográfica dos músculos masseter e temporal em função de diferentes tratamentos reabilitadores

Gomes, Isabela Silva [UNESP] 13 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-13Bitstream added on 2014-06-13T20:31:06Z : No. of bitstreams: 1 gomes_is_me_sjc.pdf: 801296 bytes, checksum: 2526ffb1511ce379c2b5d5a4874f5b70 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A função mastigatória é um dos mais complexos mecanismos neuropsicológicos no desempenho motor humano, dependendo de vários fatores como força de mordida, coordenação dos músculos, morfologia e número de dentes em oclusão. O objetivo desse trabalho é quantificar a força mastigatória máxima e analisar eletromiograficamente os músculos elevadores mandibulares de pacientes dentados totais (n=52) e reabilitados com prótese total (PT) (n=28) e prótese parcial removível (PPR) (n=27), a fim de verificar a influência de diferentes tratamentos reabilitadores na força mastigatória e atividade dos músculos masseter e temporal. A coleta dos dados de força de mordida (FM) e atividade eletromiográfica (EMG) foi realizada em triplicata em repouso e em contração isométrica através de um transdutor de força de mordida (desenvolvido pelos autores) e um eletromiógrafo EMG-800c de oito canais (EMG System do Brasil Ltda). Outras variáveis como gênero, idade, peso, estresse, prática de atividade física, lado preferencial da mastigação, formato facial e consistência da alimentação também foram levantadas e comparadas às variáveis FM e EMG em função dos grupos experimentais. Os valores de força de mordida (em Kgf) e os sinais eletromiográficos (em voltagem RMS) dos músculos masseter e temporal direito e esquerdo foram submetidos à estatística descritiva e comparados em função dos grupos experimentais por meio do teste estatístico de Análise de Variância 1 fator (ANOVA) e ao teste Tukey com nível de significância de 5%. Com relação à FM, o grupo controle (51,49 ± 16,24)A apresentou média estatisticamente superior (p=0,00<0,05) ao grupo PPR(28,45 ± 15,43)B e PT (13,11 ± 7,69)C . Com relação à EMG, em repouso... / The chewing is one of the most complex neuropsychological mechanisms in human motor performance, depending on various factors such as bite force, muscle coordination, morphology and number of teeth in occlusion. The aim of this study is to quantify the maximum bite force and analysis electromyographic of the jaw elevators muscles of dentate patients (n = 52) and rehabilitated with complete denture (CD) (n = 28) and removable partial dentures (RPD) (n = 27) in order to check the influence of different rehabilitation treatments in bite force and activity of the masseter and temporal. Data collection of bite force (BF) and electromyographic activity (EMG) was performed in triplicate at rest and during isometric contraction with a bite force transducer (developed by the authors) and an electromyograph EMG-800c eight-channel (EMG System do Brazil Ltda.) Other variations such as gender, age, weight, stress, physical activity, preferred side of chewing, facial shape and consistency of supply were also raised compared to variables BF and EMG as a function of the experimental groups. The values of bite force (kgf) and the electromyographic signals (RMS voltage) of the masseter and temporal right and left were subjected to descriptive statistics and compared on the basis of the experimental groups using the statistical test of a factor analysis of variance (ANOVA) and Tukey's test at a significance level of 5%. With respect to BF, the control group (51.49 ± 16.24) had statistically significant higher (p = 0.00 <0.05)A than PPR group (28.45 ± 15.43)B and PT (13 , 11 ± 7.69)C. Regarding the EMG at rest showed no statistical difference between any of the muscles (p> 0.05). In isometric contraction, however, the control group... (Complete abstract click electronic access below)
104

Retorque de parafusos de pilares protéticos com recobrimento de carbono tipo diamante: uma análise da manutenção do torque após fadiga mecânica

Canavezi, Rafaela Cristiane [UNESP] 10 December 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-12-10. Added 1 bitstream(s) on 2016-06-07T17:17:17Z : No. of bitstreams: 1 000865436.pdf: 1601189 bytes, checksum: c34e3709b85d75f0d4c7ed707ac9c2a8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esta pesquisa se propôs verificar a manutenção do torque, após fadiga mecânica, de parafusos de pilares protéticos com recobrimento de carbono tipo diamante (DLC) e com dopagem de diamantes (CD-DLC) submetidos ao retorque, em conexões hexagonais externa (HE) e interna (HI). Implantes HE e HI e diferentes tratamentos do parafuso protético foram alocados em grupos experimentais (n = 5): sem tratamento e não submetidos a fadiga (HE-CON) (HI-CON); sem tratamento fadigados (HECONF) (HI-CONF); com DLC fadigado (HE-DLCF) (HI-DLCF) e com CDDLC fadigados (HE-CD-DLCF) (HI-CD-DLCF). Os recobrimentos de DLC e CD-DLC foram depositados a plasma pelo método PECVD. As amostras (implante + parafusos + coroa metálica), que já haviam sido expostas a 1 milhão de ciclos de fadiga, foram retorqueadas com torquímetro digital, com o torque recomendado pelo fabricante 30 N (HE) e 20 N (HI), e submetidos novamente a 1 milhão de ciclos mecânicos. Ao término da fadiga, os parafusos foram destorqueados para verificar a manutenção do torque. Parafusos de cada grupo experimental foram selecionados para observação em MEV. A análise estatística foi realizada pelo teste Anova 2- Fatores (α = 0,05). Não houve interação entre os fatores em estudo (p = 0,765); o tratamento dos parafusos (p = 0,638) e o tipo de conexão (p = 0,615) não apresentaram diferença estatística. Alterações como danos nas roscas do parafuso e remoção do filme foram observados entre os grupos experimentais. Os grupos com revestimento apresentaram pouco ou nenhum dano nas roscas dos parafusos. O revestimento de DLC e CDDLC parece não ter interferido na adaptação do parafuso ao implante. Parafusos protéticos recobertos com DLC e CD-DLC, após o retorque, não elevaram a manutenção do torque / The study analyzed the torque maintain of the screw abutments, with coating of diamond-like carbon (DLC) and doping of diamond (CD-DLC), submitted the retorque in external hexagonal (EH) and internal (IH) connections; after mechanical fatigue. HE and HI implants and different treatments of the abutments screws were divided into experimental groups (n = 5): untreated and not subjected to fatigue (EH-CON) (IHICON); fatigued untreatment (EH-CONF) (IH-CONF); fatigued with DLC (EH- DLCF) (IH-DLCF) and fatigued with CD-DLC (EH-CD-DLCF) (IH-CD-DLCF). The DLC and CD-DLC coating was deposited by plasma, PECVD method. Samples (Implant + abutment screew + metal crown), which had been exposed to 1 million fatigue cycles were retorquiadas, digital torque wrench, to the torque recommended by the manufacturer 30 N (HE) and 20 N (HI), and submitted again to 1 million cycles mechanics. At the end of fatigue, the screws were destorquiados to check the maintenance of torque. Screws from each experimental group were selected for observation by SEM. Statistical analysis was performed by ANOVA 2 Factors test (α = 0.05). There was no interaction among the factors studied (p = 0.765); the treatment of screws (p = 0.638) and the connection type (p = 0.615) showed no statistical difference. The microscopy images showed damage the threads and covering the presence of HI connections. Changes such as damage on the screws threads and film removal were observed among the experimental groups. The coating groups showed little or no damage on the screws threads. The DLC and CD-DLC coating did not interfere in the screw adaptation on the implant. Abutments screew coating with DLC and CD-DLC, after retorque, no raised torque maintenance
105

Avaliação das microdeformações ao redor de implantes, na utilização de pilares protéticos retos e angulados 17° e 30°, sob a influência de aplicação de cargas / Evaluation micro strain around implants in the use of straight and angled abutments 17° and 30°, under the influence of loads

Rodrigues, Vinícius Anéas [UNESP] 02 August 2017 (has links)
Submitted by vinicius anéas rodrigues null (vinicius.rodrigues@fosjc.unesp.br) on 2017-08-18T17:41:55Z No. of bitstreams: 1 tese Vinícius Anéas. Versão final.pdf: 3740548 bytes, checksum: b105ec4a9bf6381e20370d163a9e7d0c (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-08-23T19:31:12Z (GMT) No. of bitstreams: 1 rodrigues_va_dr_sjc.pdf: 3740548 bytes, checksum: b105ec4a9bf6381e20370d163a9e7d0c (MD5) / Made available in DSpace on 2017-08-23T19:31:12Z (GMT). No. of bitstreams: 1 rodrigues_va_dr_sjc.pdf: 3740548 bytes, checksum: b105ec4a9bf6381e20370d163a9e7d0c (MD5) Previous issue date: 2017-08-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo in vitro foi analisar a distribuição das microdeformações geradas ao redor de implantes de hexágono externo, sob a influência da utilização de intermediários do tipo mini pilares cônicos retos e angulados 17° e 30°, sob cargas axiais e não axiais, por meio da análise de elementos finitos e extensometria. Os modelos tridimensionais foram criados simulando três blocos de poliuretano, os quais receberam três implantes cada, um grupo perpendicular e outros dois com fixações inclinadas em 17° e 30°. Para o estudo também foram modelados os intermediários do tipo mini pilar cônico reto e angulados e uma supraestrutura metálica padronizada para ambos os grupos, os materiais foram considerados homogêneos, isotrópicos e lineares. Após a confecção, as geometrias foram exportadas em malhas para o software de análises (ANSYS 15.0, ANSYS Inc., Houston, USA), um carregamento axial de 30 kgf foi aplicado e os valores de tensão e as microdeformações foram analisados. Para análise in vitro, foram confeccionados blocos idênticos aos desenhados anteriormente. Foram colados sete extensômetros na superfície dos blocos, quatro tangenciando cada um dos implantes e três na transversal dos implantes. Coifas plásticas foram adaptadas a um enceramento padronizado e depois fundidas. A supraestrutura metálica foi parafusada com torque de 10 N.cm. Para aplicação de cargas foi utilizado um dispositivo de aplicação de cargas (DAC) com uma carga de 30 kgf. durante 10 segundos. Os dados obtidos foram submetidos aos testes ANOVA e Tukey (p< 0,05). Observou-se diferença estatística para os fatores “Angulação do implante” (P=0,000) e o fator “Ponto de aplicação de carga” (P=0,000). Os dados obtidos pela análise de elementos finitos foram apresentados como: resultados qualitativos de tensão que foram analisados seguindo o esquema de cores da escala e resultados de valores de deformação, apresentados em gráficos, onde se observou maior concentração de tensão nos implantes inclinados em 30° localizados nos pontos não axiais 3 e 5 mm, o mesmo ocorreu com os valores de deformação encontrados na superfície ao redor dos implantes. O estudo concluiu que os implantes inclinados apresentaram maiores valores de microdeformações ao redor dos implantes, sendo as aplicações de cargas não axiais nos pontos 3 e 5 mm responsáveis por produzirem aumento na magnitude. Apenas o grupo reto 0° apresentou resultados dentro do limite fisiológico em todas as configurações de aplicação de carga. / The objective of this in vitro study was to analyze microstrains distribuition generated around external hexagon implants, under the influence of intermediary prosthetic componentes as straight, 17° and 30° angled miniconical abutments, under axial and non-axial loads, by finite elements and strain-gauge analysis. The three-dimensional models were created simulating three polyurethane blocks, being installed three implants each, one perpendicular group and another two with inclined fixations at 17° and 30°. For the study were also created straight and angled miniconical abutments and a standardized metallic superstructure for both groups. The materials were considered symmetrical, isotropic and solid. After the preparation, the geometries were exported in mesh to the analysis software (ANSYS 15.0, ANSYS Inc., Houston, USA). An axial load of 30 kgf was applied and the values of main maximum stress and microstrains were analyzed. For in vitro analysis, blocks identical to those created previously were made, seven strain-gauges were placed on the surface of the block, four tangential to each of the implants and three transverse to the implants. Plastic copings were adapted to a wax pattern and then cast. The metallic superstructure was screwed with a torque of 10 N.cm. For load application, a load application device (DAC) with a load of 30 kgf was used, for 10 seconds. Data were submitted to ANOVA and Tukey tests (p <0.05). Statistical difference was observed for "Implant angulation" factors (P = 0.000) and "Load application point" factor (P = 0.000). The data obtained by the finite element analysis were presented as: qualitative results of stress that were analyzed following the color scheme of the scale and results of deformation values, presented in graphs, where it observed a higher concentration of tension in the inclined implants in 30° at the non-axial points 3 and 5 mm, the same occurred with the deformation values found on the surface around the implants. The study can conclude that the inclined implants had higher values of microdeformations around the implants, and the applications of non-axial loads at points 3 and 5 mm are responsible for producing an increase in magnitude. Only the 0° straight group presented results within the physiological limit in all load application configurations.
106

Avaliação do comportamento de parafusos de retenção de próteses implanto suportadas: plataforma hexágono externo

Wingert, Augusto January 2015 (has links)
Made available in DSpace on 2015-06-18T02:05:59Z (GMT). No. of bitstreams: 1 000470532-Texto+Completo-0.pdf: 1614440 bytes, checksum: e43e90ac45fd2b22f0d595dd9c475e47 (MD5) Previous issue date: 2015 / This study aimed to evaluate "in vitro" possible changes on prosthetic retaining screws on implants with platform external hexagon, this because the loosening this component is very common in clinical dentistry practice. Were assessed screws of UCLA's pillars of titanium Neodent® brand and 3i BIOMET® and of titanium with surface treated with tungsten carbide Neodent® brand. Two techniques of utilization of the screws were compared, the technique I, recommended by the manufacturer with only the definitive torque, and the technique II, utilized in broad scale in Brazil where multiple torques are applied in the same screw simulating the clinical steps, up to definitive installation. The initial weight of all the screws (T0) was registered, in the screws of technique I, it was given definitive torque (32N. cm to Neodent® and 20N. cm to 3i BIOMET®) submitted to mechanical cycling and the final weight (TF) registered. In the screws of technique II have been applied opening and closing cycles, and their weights registered (T1, T2 and T3) before applying the definitive torque and mechanical cycling after the final weight has been registered (TF).The morphologies and the surface compositions of the screws were evaluated using SEM and EDS at each time. The results showed significant weight loss in the three screws groups, of technique I (p = 0. 005 for uncoated Neodent®, p = 0. 007 for coated Neodent® and p = 0. 001 to 3i BIOMET®) and on two the steps of the three groups of technique II (p <0. 001 for all groups), and comparing the final weight of the screws of the two techniques, the screws of the technique I, showed significantly higher values than the screws, of the technique II (p = 0. 007 for uncoated Neodent®, p = 0. 009 for coated Neodent® and p = 0. 001 to 3i BIOMET®), as well as SEM showed less permanent deformation for the technique I. EDS showed no major changes in the surface compositions. Therefore, the use of the definitive screw only at time of final torque can minimize problems regarding to the loosening the retaining screws of implant supported prostheses. / O presente estudo teve como objetivo avaliar “in vitro” possíveis alterações em parafusos de retenção de próteses sobre implantes com plataforma hexágono externo, isto porque o afrouxamento deste componente é muito frequente na prática clínica odontológica. Foram avaliados parafusos de pilares UCLA de titânio da marca Neodent® e 3i BIOMET® e de titânio com superfície tratada com carboneto de tungstênio da marca Neodent®. Duas técnicas de utilização dos parafusos foram comparadas, a técnica I, recomendada pelo fabricante com apenas o torque definitivo, e a técnica II, utilizada em grande escala no Brasil onde são aplicados múltiplos torques no mesmo parafuso, simulando as etapas clínicas até a instalação definitiva. Foi registrado o peso inicial de todos os parafusos (T0), nos parafusos da técnica I foi dado torque definitivo (32N. cm para Neodent® e 20N. cm para 3i BIOMET®), submetidos a ciclagem mecânica e registrado o peso final (TF).Nos parafusos da técnica II foram aplicados ciclos de abertura e fechamento e seus pesos registrados (T1, T2 e T3) antes da aplicação do torque definitivo e ciclagem mecânica, após o peso final foi registrado (TF). As morfologias e as composições de superfície dos parafusos foram avaliadas através de MEV e EDS em cada tempo. Os resultados evidenciaram perda significativa de peso nos três grupos de parafusos da técnica I (p=0,005 para Neodent® sem revestimento, p=0,007 para Neodent® com revestimento e p=0,001 para 3i BIOMET®) e em duas das etapas dos três grupos da técnica II (p<0,001 para todos os grupos), sendo que comparando o peso final dos parafusos das duas técnicas, os parafusos da técnica I apresentaram valores significativamente maiores que os parafusos da técnica II (p=0,007 para Neodent® sem revestimento, p=0,009 para Neodent® com revestimento e p=0,001 para 3i BIOMET®), assim como a MEV evidenciou menor deformação permanente para a técnica I. EDS não apresentou grandes alterações nas composições de superfície. Portanto, a utilização do parafuso definitivo apenas no momento do torque final pode minimizar problemas com relação ao afrouxamento de parafusos de retenção de próteses implanto suportadas.
107

Avaliação do comportamento de parafusos de retenção de próteses implanto suportadas: conexão hexágono interno

Souza, Elbio Costa January 2015 (has links)
Made available in DSpace on 2015-07-31T02:03:30Z (GMT). No. of bitstreams: 1 000472789-Texto+Completo-0.pdf: 2619919 bytes, checksum: ed658917522947aaf046eb032864fcc4 (MD5) Previous issue date: 2015 / This study aimed to evaluate "in vitro" possible changes on prosthetic retaining screws on implants with platform external hexagon, this because the loosening this component is very common in clinical dentistry practice. Were assessed screws of UCLA's pillars of titanium Neodent® brand and 3i BIOMET® and of titanium with surface treated with tungsten carbide Neodent® brand. Two techniques of utilization of the screws were compared, the technique I, recommended by the manufacturer with only the definitive torque, and the technique II, utilized in broad scale in Brazil where multiple torques are applied in the same screw simulating the clinical steps, up to definitive installation. The initial weight of all the screws (T0) was registered, in the screws of technique I, it was given definitive torque (32N. cm to Neodent® and 20N. cm to 3i BIOMET®) submitted to mechanical cycling and the final weight (TF) registered. In the screws of technique II have been applied opening and closing cycles, and their weights registered (T1, T2 and T3) before applying the definitive torque and mechanical cycling after the final weight has been registered (TF). The morphologies and the surface compositions of the screws were evaluated using SEM and EDS at each time. The results showed significant weight loss in the three screws groups, of technique I (p< 0. 005 for uncoated Neodent®, p = 0. 001 for coated Neodent® and p < 0. 001 to 3i BIOMET®) and on one step of the uncoated Neodent® group and two steps of the other two groups of technique II (p <0. 001 for all groups), and comparing the final weight of the screws of the two techniques, only the uncoated Neodent® screws of the technique I, showed significantly higher values than the screws, of the technique II (p = 0. 021 for uncoated Neodent®, p = 0. 089 for coated Neodent® and p = 0. 095 to 3i BIOMET®), as well as SEM showed less permanent deformation for the technique I of these screws. EDS showed no major changes in the surface compositions. Therefore, the use of the definitive screw only at time of final torque would not necessarily minimize problems regarding to the loosening the retaining screws of implant supported prostheses. / O presente estudo teve como objetivo avaliar “in vitro” possíveis alterações em parafusos de retenção de próteses sobre implantes com plataforma hexágono interno, pois o afrouxamento deste componente é muito frequente na prática clínica odontológica. Foram avaliados parafusos de pilares UCLA de titânio da marca Neodent® e 3i BIOMET® e de titânio com superfície tratada com carboneto de tungstênio da marca Neodent®. Duas técnicas de utilização dos parafusos foram comparadas, a técnica I, recomendada pelo fabricante com apenas o torque definitivo, e a técnica II, procedimento que é comumente realizado pelos profissionais no Brasil, onde são aplicados múltiplos torques no mesmo parafuso, simulando as etapas clínicas até a instalação definitiva. Foi registrado o peso inicial de todos os parafusos (T0), nos parafusos da técnica I foi dado torque definitivo (32N. cm para Neodent® e 20N. cm para 3i BIOMET®), submetidos a ciclagem mecânica e registrado o peso final (TF). Nos parafusos da técnica II foram aplicados ciclos de abertura e fechamento e seus pesos registrados (T1, T2 e T3) antes da aplicação do torque definitivo e ciclagem mecânica, após o peso final foi registrado (TF). As morfologias e as composições de superfície dos parafusos foram avaliadas através de MEV e EDS em cada tempo. Os resultados evidenciaram perda significativa de peso nos três grupos de parafusos da técnica I (p<0,001 para Neodent® sem revestimento, p=0,001 para Neodent® com revestimento e p<0,001 para 3i BIOMET®), e em uma das etapas do grupo Neodent sem cobertura e duas etapas dos outros dois grupos da técnica II (p<0,001 para todos os grupos), sendo que comparando o peso final dos parafusos das duas técnicas, apenas os parafusos Neodent® sem revestimento da técnica I apresentaram valores significativamente maiores que os parafusos da técnica II, (p=0,021 para Neodent® sem revestimento, p=0,089 para Neodent® com revestimento e p=0,095 para 3i BIOMET®), do mesmo modo a MEV evidenciou menor deformação permanente para a técnica I desses parafusos. EDS não apresentou grandes alterações nas composições de superfície. Portanto, a utilização do parafuso definitivo apenas no momento do torque final não minimizará necessariamente problemas com relação ao afrouxamento de parafusos de retenção de próteses implanto suportadas.
108

Influência da normalização dos níveis de cinza em tomografias computadorizadas Cone Beam e multislice na avaliação da qualidade óssea

Schneider, Danilo Renato January 2014 (has links)
Made available in DSpace on 2015-09-05T02:05:04Z (GMT). No. of bitstreams: 1 000474617-Texto+Completo-0.pdf: 1140625 bytes, checksum: 1e763d7b5cf7e0a7ceeb1f2842c8c315 (MD5) Previous issue date: 2014 / This paper aims to investigate the influence of normalization in cone beam computed tomography (CBCT) and multislice computed tomography (MSCT) grey level to assess bone quality of recipient sites for dental implants. DICOM (Digital Imaging and Communications in Medicine) images from 37 bone sites (18 patients) were analyzed. CBCT was performed with 5 different CBCT devices and MSCT in a single multislice CT scanner. Measurements of mean grey level were performed in two regions of interest; ROI1 - alveolar bone (cortical and trabecular) and ROI2 - cancellous bone separately with 3 tested forms: no normalization (RAW), normalization of the whole image (ALL) and normalization of the region of interest only (ROI). Descriptive analysis with coefficient of variation (CV) and one-way ANOVA followed by Tukey was performed. For MSCT, ROI1 mean grey level slightly increased from 121. 9+-17. 13 (RAW) to 125. 0+-15. 74 (ALL) (p>0. 05) and reduced to 104. 8+-15. 20 (ROI) (p<0. 0001). CV varied from 14. 05%, to 12. 59% and 14. 50%, respectively. ROI2 increased from 95. 11+-13. 96 (RAW) to 99. 40+-13. 62 (ALL) and 102. 5+-17. 86 (ROI) (p=0. 0678). CV was 14. 67% to 13. 71% and 17. 43%, respectively. In CBCT group, ROI1 meaningfully raise from 91. 73+-32. 17 (RAW) to 135. 2+-36. 06 (ALL) and 118. 7+-18. 65 (ROI) (p<0. 0001), with CV decreasing from 35. 06% to 26. 68% and 15. 71%, respectively. ROI2 was 81. 23+-34. 36, 115. 3+-28. 53 and 109. 4+-17. 47, respectively (p=0. 0002), with a CV reducing from 42. 30% (RAW) to 24. 74% (ALL) and 15. 97% (ROI). Therefore, the use of intensity normalization of CBCT and MSCT examinations was demonstrated on reducing discrepancies between different scanners and inter-exams variability in bone quality assessment for dental implants. / Este trabalho objetiva investigar a influência da normalização dos níveis de cinza em tomografias cone beam (CBCT) e multislice (MSCT). Imagens DICOM (Digital Imaging and Communications in Medicine) de 37 sítios ósseos (18 pacientes) foram analisadas. As tomografias CBCT foram realizadas em 5 diferentes aparelhos e as tomografias MSCT foram obtidas em um único tomógrafo. As medições dos níveis de cinza foram feitas em duas regiões de interesse; ROI1 - osso alveolar (cortical e medular) e ROI2 - osso medular separadamente, de 3 formas distintas: sem normalização (RAW), normalização de toda a imagem (ALL) e normalização da região de interesse apenas (ROI). Análise descritiva com coeficiente de variação (CV) e teste ANOVA seguido de Tukey foi realizado. Para as MSCT, a média dos níveis de cinza da ROI1 aumentaram levemente de 121,9+-17,13 (RAW) para 125,0+-15,74 (ALL) (p>0,05) e reduziram para 104,8+-15,20 (ROI) (p<0,0001). O CV variou de 14,05%, para 12,59% and 14,50%, respectivamente. Na ROI2 a média aumentou de 95,11+-13,96 (RAW) para 99,40+-13,62 (ALL) e 102,5+-17,86 (ROI) (p=0,0678). O CV foi de 14,67% para 13,71% e 17,43%, respectivamente. No grupo CBCT, a média de ROI1 aumentou significativamente de 91,73+-32,17 (RAW) para 135,2+-36,06 (ALL) e 118,7+-18,65 (ROI) (p<0,0001), com o CV diminuindo de 35,06% para 26,68% e 15,71%, respectivamente. A média da ROI2 foi 81,23+-34,36, 115,3+-28,53 and 109,4+-17,47, respectivamente (p=0,0002), com um CV reduzindo de 42,30% (RAW) para 24,74% (ALL) e 15,97% (ROI). Desta forma, foi demonstrada a redução das discrepâncias entre diferentes aparelhos e da variabilidade entre exames com a utilização da normalização de intensidade de exames CBCT e MSCT na avaliação da qualidade óssea para implantes dentais.
109

Construção de um biomodelo com interposição de placa oclusal para análise de tensões nos discos articulares da ATM pelo método dos elementos finitos

Silva, Carlos Augusto Gomes da January 2016 (has links)
Made available in DSpace on 2016-05-07T12:04:33Z (GMT). No. of bitstreams: 1 000478489-Texto+Parcial-0.pdf: 134804 bytes, checksum: 6d941459abeadf56a9fb5b1afbfe9927 (MD5) Previous issue date: 2016 / The aim of this study was to investigate the possibility of creating a three-dimensional model of the masticatory system of a patient for analysis in MEF. Also, to configure the parameters for the attainment of a clenching test with variations in intensities bite force with the interposition of two occlusal splints of different materials. Using the computed tomography (CT) and magnetic resonance imaging (MRI) of a patient, were built, through the process of reverse engineering, seven pieces to compose a biomodel. Four software was used throughout the process to achieve the desired result. Also, from this model was created finite element mesh of components and defined the boundary conditions. An occlusal splint was created and its physical and mechanical properties were switched to simulate the behavior of two different plates: a rigid and resilient. The model received force vectors that simulate the action of four pairs of muscles: temporal, masseter, medial pterygoid and lateral; and was assigned to these three distinct forces for each test: 25oN, 50oN and 75oN. According to what was found in this study it can be concluded that the construction of a biomodel from CT and MR images are completely feasible. In addition, the methodology used to obtain the models and the settings configured for the tests in MEF resulted in a good approach to clinical reality along the lines of current research. / O objetivo do presente estudo foi verificar a possibilidade da criação de um modelo tridimensional do sistema mastigatório de um paciente para análise em MEF. E também, configurar os parâmetros para a realização de um teste de apertamento dentário com variações nas intensidades de força de mordida com a interposição de duas placas oclusais de diferentes materiais. A partir dos exames de tomografia computadorizada (TC) e ressonância magnética (RM) de um paciente foram construídos, por meio de engenharia reversa, sete peças para compor um biomodelo. Quatro softwares foram usados em todo o processo até atingir o resultado desejado. Ainda, a partir deste modelo foi criada a malha de elementos finitos dos componentes e definidas as condições de contorno. Uma placa oclusal foi criada e suas propriedades físicas e mecânicas foram alternadas para simular o comportamento de duas placas distintas: uma rígida e uma resiliente. O modelo recebeu vetores de força que simularam a ação de quatro pares de músculos: temporal, masséter, pterigoideo medial e lateral; e foi atribuído a estes, três forças distintas para cada teste: 25ON, 50oN e 75oN. De acordo com o que foi apurado neste estudo é possível concluir que a construção de um biomodelo a partir de imagens de TC e RM e plenamente viável. Além disso, a metodologia adotada para obtenção dos modelos e as configurações definidas para os testes em MEF resultaram em uma boa aproximação a realidade clinica seguindo a linha das pesquisas vigentes.
110

Efeito do envelhecimento In Vitro na transformação de fase cristalina da Y-TZP : análise topográfica, mecânica e cristalográfica /

Arata, Anelyse. January 2012 (has links)
Orientador: Rubens Nisie Tango / Coorientador: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Banca: Rubens Nisie Tango / Banca: João Paulo Barros Machado / Banca: Tarcísio José de Arruda Paes Junior / Resumo: A literatura mostra escassez de informações sobre o envelhecimento de cerâmicas Y-TZP de uso odontológico. O objetivo deste estudo foi o de avaliar o efeito do envelhecimento in vitro inicial em autoclave e avaliar a curva cinética de transformação de fase através do envelhecimento em reator hidrotérmico pressurizado em zircônia odontológica (Y-TZP). Especificamente: a - identificar o início da degradação, b - avaliar a resistência mecânica após envelhecimento inicial em autoclave, ccomparar diferentes métodos de leitura quanto à transformação de fase e análise topográfica, d - determinar a cinética de cristalização isotérmica por meio do envelhecimento em reator, e -comparar os métodos de quantificação a partir da equação de Garvie e Nicholson e o método de Rietveld. Discos de zircônia (12mm Ø x 1,2mm em espessura) foram divididos em grupos: A) envelhecido em autoclave (n=10); B) envelhecido em reator (n=4). O grupo A foi submetido ao envelhecimento em autoclave (134 oC, 2 bar), em tempos de 6, 15, 30, 42, 60, 90, 144, 198, 240, 300 e 360 minutos. O grupo B foi submetido ao envelhecimento em reator (130 oC, 2 bar), em tempos de 6, 8, 10, 12, 14, 20, 30, 40, 48, 60, 84, 108 e 138 horas. A caracterização superficial e cristalográfica foi realizada antes e depois em microscopia de força atômica (MFA), Perfilometria óptica, Difração de Raios-X e, também foram realizadas análises em microscopia eletrônica de varredura (MEV) e Raman. O grupo envelhecido em autoclave foi submetido ao teste de flexão biaxial. Os valores de Ra (nm) obtidos em Perfilometria Óptica, os valores de resistência (MPa) e os valores de transformação de fase cristalina t-m (%) foram submetidos à análise de variância de 1 fator e ao teste de Tukey... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The literature shows a lack of information about Y-TZP aging of dental ceramics. The aim of this study was to evaluate the initial in vitro aging effect and evaluate the kinetic curve of phase transformation through the pressurized hydrothermal reactor of dental zirconium. Specifically: a- the identification of the beginning of degradation; b- evaluation of the mechanical resistance after steam aging; c- compare different methods of phase transformation and topographic analysis, d- determine the kinetic of crystallization through the reactor; e- compare the phase quantification methods between the Garvie and Nicholson equation and Rietveld Method. Discs of zirconium (12mm Ø x 1,2mm thickness) were divided in groups: A) steam aged (n=10); B) Hydrothermal reactor aged (n=4). The group A was submitted to water steam aging (134 oC, 2 bar) for 6, 15, 30, 42, 60, 90, 144, 198, 240, 300 and 360 minutes. The group B was submitted to reactor aging (130 oC, 2 bars), for 6; 8; 10; 12; 14; 20; 30; 40; 48; 60; 84; 104 and 138 hours. The surface and crystallographic characterization before and after aging were made using atomic force microscopy (AFM), Optical Profilometry, X-ray diffraction (DRX), scanning electron microscopy (SEM) and Raman spectroscopy. The steam aged group was submitted to biaxial flexure test. The values of Ra (nm) obtained by optical profilometry and the crystalline phase transformation values t-m (%) were submitted to One Way ANOVA and Tukey test(α=0,05). A gradual increase was observed at the monoclinic phase concentration as the time increased and in the same way the roughness values increased. The resistance values demonstrated a tendency to decrease with the increase of aging time. The group aged by the reactor presented the increase of monoclinical phase reaching 60% of saturation through... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0783 seconds