• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 7
  • 7
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Preliminary performance study of Sherwood regulator /

Barrera Valero, Osvaldo Augusto. January 2006 (has links) (PDF)
Project Report (M.E.)--University of Puerto Rico, Mayagüez Campus, 2006. / Tables. Printout. Abstract in English and Spanish. Includes bibliographical references (leaves 66-67).
2

Study and dynamic modeling of a pressure transducer that is based on the principle of force balance

SOARES, ADALBERTO J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:15Z (GMT). No. of bitstreams: 1 01367.pdf: 3617426 bytes, checksum: d5581760fe32e1a142cc2485e18cc224 (MD5) / Tese (Doutoramento) / IPEN/T / University of Tennessee, Nuclear Engineering Department, Knoxville, Tn - USA
3

Study and dynamic modeling of a pressure transducer that is based on the principle of force balance

SOARES, ADALBERTO J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:15Z (GMT). No. of bitstreams: 1 01367.pdf: 3617426 bytes, checksum: d5581760fe32e1a142cc2485e18cc224 (MD5) / Tese (Doutoramento) / IPEN/T / University of Tennessee, Nuclear Engineering Department, Knoxville, Tn - USA
4

Investigation of dynamic temperature response of pressure transducers

Iyer, Ramalingam Subramanyam, January 1970 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1970. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
5

A kinetic study of the pyrolysis of methylchloroformate in an all glass system

McCray, Ernest Grant, 1932- January 1955 (has links)
No description available.
6

A high-resolution superconducting pressure gauge and irreversible magnetic effects in Nb and NbTi wires

Saxey, David W. January 2005 (has links)
A high resolution pressure gauge has been developed for use in thermodynamic measurements along the lambda line in liquid helium. The gauge was designed to operate at cryogenic temperatures and provide pressure measurements up to 30bar, with an accuracy of 3 × 10¯¹ºbar in a 1Hz bandwidth. Experiments reported here show the gauge to have met these specifications; at least for measurements close to zero pressure, at temperatures close to 4.5K. It is expected that operation at higher pressures, and at temperatures closer to the lambda transition, will result in similar or even improved performance. The gauge consists of a titanium-alloy diaphragm with a superconducting position transducer read-out. Compensation techniques internal to the superconducting circuit were used to eliminate any significant sensitivity to temperature fluctuations and in-line acceleration. For high values of common-mode rejection, thermal compensation revealed a non-linear temperature characteristic which was exploited to provide a further reduction in the temperature sensitivity. Acceleration compensation was achieved up to a common-mode rejection of more than 78dB. Present performance appears to be limited by thermal gradient fluctuations at low frequencies and at higher frequencies by a noise source which appears to originate beyond the superconducting transducer. It is expected that some further improvement may be gained in this higher frequency band simply by trapping a larger persistent current in the superconducting circuit. In the course of development and characterization of the gauge several anomalous effects were discovered and investigated. In response to changes in temperature, the gauge was found to exhibit irreversible behaviour in a variety of ways. These phenomena were fully investigated and found to be complex in nature. A critical state model was employed which was successful in explaining many of the observed effects. Other authors have observed apparently related behaviour in samples of niobium and some have developed similar critical state models which give results generally consistent with those reported here. However, these latter works have not investigated the presence of such effects within superconducting wires; neither have they considered the implications for devices based upon superconducting wire circuits. It appears this anomalous behaviour may be relevant to a broad range of instruments employing superconducting wire circuits similar to that used here. If this is the case, the results presented here have significant consequences for the performance of such devices
7

Desenvolvimento de um sistema de irradiação para produção de radioisótopos gasosos aplicados em processos industriais / Development of a irradiation system for production of gaseous radioisotopes applied in industrial processes

Cardozo, Nelson X. 02 May 2017 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2017-05-02T11:34:44Z No. of bitstreams: 0 / Made available in DSpace on 2017-05-02T11:34:44Z (GMT). No. of bitstreams: 0 / Dentre as diversas aplicações dos radioisótopos, a utilização dos radiotraçadores é considerada uma das mais importantes, no diagnóstico de funcionamento dos equipamentos de processos, em plantas de indústrias químicas e petroquímicas. Os radiotraçadores são utilizados em procedimentos analíticos para obtenção de dados qualitativos e quantitativos de sistemas, em estudos de transferências físicas e físico-químicas. Na produção de radioisótopos gasosos utilizados como traçadores em processos industriais, destacam-se o 41Ar e 79Kr, gases nobres (inertes) que possuem baixa reatividade com os demais elementos químicos. O 41Ar é um emissor gama de alta energia (1,29 MeV) e apresenta elevada porcentagem de transformações com essa energia, o que resulta em quantidades relativamente pequenas necessárias em relação a outras para uma detecção eficaz, mesmo em componentes com grandes espessuras. Atualmente, a produção de radioisótopos gasosos em reatores nucleares de pesquisa é realizada em pequenas quantidades (bateladas), por meio de ampolas de quartzo contendo o gás natural 40Ar ou 78Kr. Nesse sentido, o objetivo desse estudo é desenvolver um sistema de irradiação capaz de produzir em escala contínua, o radioisótopo gasoso 41Ar, dentre outros, com atividade de 7,4x1011 Bq (20 Ci) por ciclo de irradiação, por meio do Reator IEA-R1 de 4,5 MW, fluxo de nêutrons térmicos médio de 4,71 x 1013 ncm-2s-1, para suprir uma demanda existente em empresas de END e inspeções, e pelo próprio Centro de Tecnologia das Radiações, no IPEN/CNEN-SP. O sistema de irradiação (SI) é constituído por uma cápsula de irradiação em alumínio, linhas de transferência, válvulas agulhas, conexões anilhadas, conectores rápidos, manovacuômetro, sistema de vácuo, dewar de liquefação, blindagem em chumbo, cilindros de armazenamento e transporte (CAT), dentre outros. O SI foi aprovado nos testes de estanqueidade e estabilidade (testes de formação de bolhas, pressurização, evacuação e com equipamento leak detector SPECTRON 600 T). Na produção experimental para obtenção de 1,07x1011 Bq (2,9 Ci) de 41Ar, distribuíram-se dosímetros de alanina em diversos componentes e dispositivos do SI. Além disso, determinaram-se as taxas de exposição na parede da blindagem em chumbo, ao concentrar o gás radioativo liquefeito e no CAT, após a transferência do 41Ar, pelo medidor de radiação portátil Teletector ® Probe 6150 AD-t/H. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0432 seconds