• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise do desempenho de condicionadores experimentais no tratamento de ligas metálicas / Evaluation of experimental conditioners in the metal alloys treatment

Azevedo, Eduardo Costa de 19 December 2007 (has links)
Made available in DSpace on 2014-08-20T14:30:18Z (GMT). No. of bitstreams: 1 Dissertacao_Eduardo_Costa_de_Azevedo.pdf: 706035 bytes, checksum: 2849c6cbcccaf4c4e34fbdb0b6e8e482 (MD5) Previous issue date: 2007-12-19 / The aim of this study was to investigate the performance of three experimental surface conditioners on metal alloys of different chemical composition, through microshear tests and failure analysis. Three metal alloys (NiCr, AgPd, AgAu) were melted in disc-shaped specimens (3mm in thickness x 10mm in diameter) and their surfaces were polished with aluminum oxide abrasive papers (400-, 600- and 1200-grit). The groups were treated with one of the experimental surface conditioners, and a commercial material (Alloy Primer Kuraray) was used as a control. The bonding agent of the Adper Scotchbond system (3M) was applied, and cylindrical specimens were made with a resin cement (Rely X ARC 3M), with an adhesion area of 1.13mm2. The bonding agent and the cement were light-activated for 40s (LED SDI Radii® - 1400mW/cm2). The micro-shear test was conducted at a cross-head speed of 0.5mm/min. Bond strength values were calculated in MPa (N/mm2) and submitted to ANOVA and Tukey s post-hoc test (p<0.05). Fractographic analyzes were performed under optical microscopy (40X) and classified as adhesive, mixed or cohesive. The experimental surface conditioners did not present a satisfactory performance factor due to the means variation in the metal alloys used in the study. A predominance of adhesive failures was detected. In conclusion, the experimental surface conditioners presented a significant adhesion to all metal alloys. However, these materials need modifications to obtain values more approximate to the commercial material / O objetivo deste estudo foi avaliar o desempenho de três condicionadores experimentais em ligas metálicas de diferentes composições químicas, através de testes de microcisalhamento e análise de fratura. Três ligas metálicas (NiCr, AgPd, AgAu) foram fundidas em forma de disco (3x10 mm) e suas superfícies foram preparadas com lixas d água (400, 600 e 1200#). Todos os grupos receberam um tratamento superficial com quatro condicionadores, sendo três experimentais e um comercial (Alloy Primer- Kuraray Medical Corporation, Kurashiki, Okayama, Japão) que serviu de controle. Logo após o condicionamento, foi aplicado o adesivo do sistema Adper Scotchbond (3M Dental Products Division, Saint Paul, MN, EUA) e sobre este foram confeccionados os corpos de prova com um cimento resinoso de ativação dupla Rely X ARC (3M Dental Products Division, Saint Paul, MN, EUA) com uma área de adesão de 1,13 mm2. O adesivo e o cimento resinoso utilizados foram fotoativados com aparelho LED SDI Radii® (1400mW/cm2) por 40 segundos. Os ensaios mecânicos foram executados com velocidade de 0,5 milímetros por minuto. Os valores de resistência adesiva foram registrados em MPa (N/mm2 = Newton/milímetro2) e submetidos a Análise de Variância e teste complementar de Tukey para detectar diferença entre as médias (p < 0,05). A análise da superfície de fratura foi observada através de microscopia óptica com um aumento de 40X sendo classificada como falha adesiva, mista ou coesiva. Os condicionadores experimentais não apresentaram um fator de desempenho satisfatório devido à variação das médias nos substratos metálicos utilizados. Houve predominância de falha do tipo adesiva. Baseado na metodologia foi possível concluir que os condicionadores experimentais apresentaram resistência de união significante nos grupos avaliados, porém necessitam de modificações para alcançarem valores mais aproximados ao material comercial
2

Influência da conicidade do pilar e tipo de agente cimentante na retentividade de coroas metálicas cimentadas sobre pilares personalizáveis de implantes

Dantas, Talita Souza 16 December 2011 (has links)
Several factors must be considered in the selection of angled abutments. In these situations, the clinician should find a practical way to overcome the lack of retention. The purpose of this study was to evaluate the bond strength of metallic crowns cemented to straight and angled customizable abutments with different definitive luting agents. Ninety one regular external hex analogs and abutments were divided in Control group (C): customizable straight abutment cemented with zinc phosphate (n = 10); three groups (n = 10) with 17° angled abutment cemented with zinc phosphate (A17ZP), Panavia F (A17RM) and RelyX U100 (A17R) cements and more three groups (n = 10) with 30° angled abutment also cemented with zinc phosphate (A30ZP), Panavia F (A30RM) and RelyX U100 (A30R) cements. The metal copings were cemented onto their corresponding metal dies and crowns cemented with Panavia F were pre-treated with an alloy primer containing an acid-phosphated monomer (MDP). Data from the all groups were compared to control group with a 1-way ANOVA (&#945;=.05) and Dunnet s test, and comparison between tested groups were done with 2-way ANOVA (&#945;=.05) and Tukey s test. SEM and CLSM evaluation were performed (n = 3) aiming to investigate microscopic features of the abutment-cement-crown interfaces. The mean force (SD) required to dislodge the crowns in the C, A17ZP, A17RM, A17R, A30ZP, A30RM and A30R groups was 357,26 (62,21) N; 251,50 (20,13) N; 397,05 (88,48) N; 328,71 (79,87) N; 276,70 (17,96) N; 377,81 (90,61) N and 335,42 (88,34) N respectively. Panavia F presented the higher tensile bond strength results and zinc phosphate the lower between the tested groups. Only A17ZP group was different from control group (p=.007) and the abutment taper has no influence in retentive values. Zinc phosphate showed an inhomogeneous cement line in SEM and CLSM analysis. The presence of MDP primer could be perceived in CLSM images of Panavia F group. Within the limitations of this in vitro study, the Panavia F presented the higher bonding strength between tested groups, however, all 3 cements tested were similar to control group except A17ZP group, showing that in the conditions of the study they all can be successfully used. / Vários fatores devem ser considerados na seleção dos pilares angulados, assim, muitas vezes, o clínico deve encontrar uma forma prática de superar a falta de retenção resultante das características desse tipo de pilar. O objetivo deste estudo foi avaliar a resistência de união de coroas metálicas cimentadas sobre pilares personalizáveis retos e angulados, cimentados com diferentes agentes de cimentação definitivos. Noventa e um análogos de implantes regulares do tipo hexágono externo foram divididos em Grupo controle (C): pilar reto personalizável cimentado com fosfato de zinco (n = 10); três grupos (n = 10) com pilares angulados de 17° cimentados com fosfato de zinco (A17F), Panavia F (A17RM) e RelyX U100(A17R) e ainda mais três grupos (n = 10) com pilares angulados de 30° também cimentados com cimento de fosfato de zinco (A30F), Panavia F (A30RM) e RelyX U100 (A30R). Coroas de Níquel-Cromo foram confeccionadas e cimentadas em seus pilares correspondentes sendo que as coroas cimentadas com Panavia F foram pré-tratadas com um primer para metal contendo monômero ácido fosfatado (MDP). Dados de todos os grupos foram comparados ao grupo controle por meio da análise de variância ANOVA - One way (&#945; =0,05) e teste de Dunnet, e a comparação entre os grupos testados foi realizada por meio de análise de variância ANOVA Two way (&#945; =0,05) e teste de Tukey. Ainda as avaliações em MEV e MVCL foram realizadas com 3 amostras representativas de cada grupo com o objetivo de investigar as características microscópicas das interfaces pilar-coroa-cimento. A média de força (DP) necessária para deslocar as coroas nos grupos C, A17F, A17RM, A17R, A30F, A30RM e grupos A30R foram, respectivamente, 357,26 (62,21) N; 251,50 (20,13) N; 397, 05 (88,48) N; 328,71 (79,87) N; 276,70 (17,96) N; 377,81 (90,61) N e 335,42 (88,34) N. O cimento Panavia F apresentou os resultados mais elevados de resistência a tração (RT) e o fosfato de zinco apresentou os menores valores de RT entre os grupos testados. Apenas o grupo A17F foi estatisticamente diferente do grupo controle (p = 0,007) e a inclinação das paredes axiais do pilar não influenciou os valores de retenção obtidos. O fosfato de zinco apresentou uma linha de cimentação não homogênea na análise em MEV e MVCL. A presença de primer contendo MDP pode ser percebida nas imagens de MVCL do grupo Panavia F. Dentro das limitações deste estudo in vitro, o Panavia F apresentou a maior resistência de união entre os grupos testados, no entanto, todos os três cimentos testados foram semelhantes ao grupo controle, exceto o grupo A17F grupo, mostrando que nas condições do estudo todos eles podem ser usados com sucesso. / Mestre em Odontologia

Page generated in 0.0728 seconds