• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Incorporação de nanopartículas de prata pelo processo de irradiação em Cateter Venoso Central (CVC) de poliuretano revestido com óxido de titânio para atividade antibacteriana / Incorporation of silver nanoparticles by the irradiation process in Central Venous Catheter (CVC) of polyurethane coated with titanium oxide for antimicrobial activity

Freitas, Patricia de 12 July 2018 (has links)
Os cateteres intravasculares são aliados indispensáveis na prática da medicina moderna, particularmente em unidades de terapia intensiva (UTIs). Pelo Cateter Venoso Central (CVC) pacientes que ficam muito tempo internados recebem medicação e alimentação sendo, no entanto, importante fonte de infecção da corrente sanguínea primária. Os CVC\'s de poliuretano podem ter sua superfície modificada pela incorporação de titânio e prata (Ti/Ag) que possuem características antimicrobianas conhecidas desde a antiguidade. A incorporação das nanopartículas de prata sobre o polímero pode ser feita com o uso da radiação ionizante, que também irá esterilizar o material. Assim, este trabalho tem por objetivo utilizar a radiação ionizante para incorporação de nanopartículas de prata em Cateter Venoso Central (CVC) a fim de adquirir propriedades antibactericidas. Para isto utilizou-se o CVC Pellethane 2363-65D, termoplástico de poliuretano elastômero (TPU), óxido de titânio puro, sintetizado pelo processo sol-gel e nanopartículas de prata (NpAg_925). A irradiação para incorporação da prata foi com dose de 25 kGy e com taxa de dose de 1,03 kGy/h em um irradiador \"Gammacel 220\" de 60Co. Posteriormente, os cateteres foram esterelizados com dose de 25 kGy. Pode-se concluir que a incorporação da prata pelo processo de irradiação foi possível e que este processo não afeta a estrutura do polímero, o que é importante para a correta inserção do cateter venoso central no corpo do paciente. Observou-se que o método sol-gel, para deposição do titânio na superfície do CVC, não foi homogênea, dificultando a incorporação da prata que depende do titânio neste processo. Os testes de análise antimicrobiana não indicaram atividade antimicrobiana nos cateteres revestido com titânio e prata, acredita-se que a metodologia escolhida seja inadequada para o tipo de análise. / Intravascular catheters are indispensable allies in the practice of modern medicine, particularly in intensive care units (ICUs). Central Venous Catheter (CVC) patients who are hospitalized for a long time receive medication and feeding, however, being an important source of infection of the primary bloodstream. Polyurethane CVCs may have their surface modified by the incorporation of titanium and silver (Ti/Ag) which have antimicrobial characteristics known from antiquity. The incorporation of the silver nanoparticles on the polymer can be done with the use of ionizing radiation, which will also sterilize the material. Thus, this work aims to use ionizing radiation to incorporate silver nanoparticles in Central Venous Catheter (CVC) in order to acquire antibacterial properties. For this purpose CVC Pellethane 2363-65D, thermoplastic elastomer polyurethane (TPU), pure titanium oxide, synthesized by the sol-gel process and silver nanoparticles (NpAg_925) were used. Irradiation for incorporation of silver was at a dose of 25 kGy and at a dose rate of 1.03 kGy/h in a \"Gammacell 220\" irradiator of 60Co. Subsequently, the catheters were sterilized at a dose of 25 kGy. It can be concluded that the incorporation of silver by the irradiation process was possible and that this process does not affect the structure of the polymer, which is important for the correct insertion of the central venous catheter into the patient\'s body. It was observed that the sol-gel method, for deposition of the titanium on the surface of the CVC, was not homogeneous, making difficult the incorporation of the silver that depends on the titanium in this process. The antimicrobial analysis tests did not indicate antimicrobial activity in catheters coated with titanium and silver, it is believed that the chosen methodology is inadequate for the type of analysis.
2

Incorporação de nanopartículas de prata pelo processo de irradiação em Cateter Venoso Central (CVC) de poliuretano revestido com óxido de titânio para atividade antibacteriana / Incorporation of silver nanoparticles by the irradiation process in Central Venous Catheter (CVC) of polyurethane coated with titanium oxide for antimicrobial activity

Patricia de Freitas 12 July 2018 (has links)
Os cateteres intravasculares são aliados indispensáveis na prática da medicina moderna, particularmente em unidades de terapia intensiva (UTIs). Pelo Cateter Venoso Central (CVC) pacientes que ficam muito tempo internados recebem medicação e alimentação sendo, no entanto, importante fonte de infecção da corrente sanguínea primária. Os CVC\'s de poliuretano podem ter sua superfície modificada pela incorporação de titânio e prata (Ti/Ag) que possuem características antimicrobianas conhecidas desde a antiguidade. A incorporação das nanopartículas de prata sobre o polímero pode ser feita com o uso da radiação ionizante, que também irá esterilizar o material. Assim, este trabalho tem por objetivo utilizar a radiação ionizante para incorporação de nanopartículas de prata em Cateter Venoso Central (CVC) a fim de adquirir propriedades antibactericidas. Para isto utilizou-se o CVC Pellethane 2363-65D, termoplástico de poliuretano elastômero (TPU), óxido de titânio puro, sintetizado pelo processo sol-gel e nanopartículas de prata (NpAg_925). A irradiação para incorporação da prata foi com dose de 25 kGy e com taxa de dose de 1,03 kGy/h em um irradiador \"Gammacel 220\" de 60Co. Posteriormente, os cateteres foram esterelizados com dose de 25 kGy. Pode-se concluir que a incorporação da prata pelo processo de irradiação foi possível e que este processo não afeta a estrutura do polímero, o que é importante para a correta inserção do cateter venoso central no corpo do paciente. Observou-se que o método sol-gel, para deposição do titânio na superfície do CVC, não foi homogênea, dificultando a incorporação da prata que depende do titânio neste processo. Os testes de análise antimicrobiana não indicaram atividade antimicrobiana nos cateteres revestido com titânio e prata, acredita-se que a metodologia escolhida seja inadequada para o tipo de análise. / Intravascular catheters are indispensable allies in the practice of modern medicine, particularly in intensive care units (ICUs). Central Venous Catheter (CVC) patients who are hospitalized for a long time receive medication and feeding, however, being an important source of infection of the primary bloodstream. Polyurethane CVCs may have their surface modified by the incorporation of titanium and silver (Ti/Ag) which have antimicrobial characteristics known from antiquity. The incorporation of the silver nanoparticles on the polymer can be done with the use of ionizing radiation, which will also sterilize the material. Thus, this work aims to use ionizing radiation to incorporate silver nanoparticles in Central Venous Catheter (CVC) in order to acquire antibacterial properties. For this purpose CVC Pellethane 2363-65D, thermoplastic elastomer polyurethane (TPU), pure titanium oxide, synthesized by the sol-gel process and silver nanoparticles (NpAg_925) were used. Irradiation for incorporation of silver was at a dose of 25 kGy and at a dose rate of 1.03 kGy/h in a \"Gammacell 220\" irradiator of 60Co. Subsequently, the catheters were sterilized at a dose of 25 kGy. It can be concluded that the incorporation of silver by the irradiation process was possible and that this process does not affect the structure of the polymer, which is important for the correct insertion of the central venous catheter into the patient\'s body. It was observed that the sol-gel method, for deposition of the titanium on the surface of the CVC, was not homogeneous, making difficult the incorporation of the silver that depends on the titanium in this process. The antimicrobial analysis tests did not indicate antimicrobial activity in catheters coated with titanium and silver, it is believed that the chosen methodology is inadequate for the type of analysis.
3

Desenvolvimento com tinta de nanocarga para aplicação nos estudos da velocidade de corrosão. / Development with nanocarga paint for application in corrosion speed studies.

Siqueira, Gonçalo 24 July 2018 (has links)
A corrosão é um dos problemas mais relevantes que afronta a indústria atual, representa mais de 25% do investimento destinado para reparos ou troca de equipamentos com falhas por problemas do ataque corrosivo. Neste panorama nos últimos anos houve um grande aumento no desenvolvimento de novas tecnologias para proteção das estruturas, por outro lado o aço ABTN 1020 é um dos materiais mais usados na indústria principalmente em ambientes contendo cloreto. A sua utilização não é recomendada pelas altas taxas de corrosão, sendo necessário à adoção de pintura como meio de proteção. Este trabalho investigou a resistência à corrosão de uma pintura em meios contendo cloreto cuja composição da matriz foi resina uretânica (PU) e diferentes cargas a base de SiO2 e ZnO em diversas concentrações, sendo avaliadas mediante técnicas de Impedância Eletroquímica- EIS e de varredura com elétrodo vibratório SVET. Verificou-se que a espectroscopia e SVET também fornecem informação suficiente relativo ao desgaste e a possível ação da corrosão, sendo assim foi evidenciado que pintura com carga a base de SiO2 que tem melhor resistência à corrosão em meios contendo cloreto. Em outra análise quando comparados com a carga de ZnO pintura com irradiação, observou-se que houve um aumento na aderência da pintura ao metal base, fornecendo uniformidade e maior proteção anticorrosiva, assim foram determinados parâmetros que podem aplicações na indústria. / Corrosion is one of the most important problems facing today\'s industry, representing more than 25% of the investment destined for repairs or exchange of equipment with failures due to corrosive attack problems. In this panorama in recent years there has been a great increase in the development of new technologies for protection of structures, on the other hand the steel ABTN 1020 is one of the materials most used in the industry mainly in environments containing chloride. Its use is not recommended due to the high corrosion rates, and it is necessary to adopt painting as a means of protection. This work investigated the corrosion resistance of a paint in chloride-containing media whose urethane resin (PU) composition and different SiO2 and ZnO-based loads were evaluated in various concentrations and evaluated by Electrochemical Impedance-EIS and scanning with vibrating electrode SVET. It was verified that the spectroscopy and SVET also provide sufficient information regarding the wear and the possible action of the corrosion, thus it was evidenced that paint with charge based on SiO2 that has better resistance to corrosion in media containing chloride. In another analysis when compared with the ZnO charge with irradiation paint, it was observed that there was an increase in the adhesion of the paint to the base metal, providing uniformity and greater anticorrosive protection, thus determined parameters that can be applied in the industry.
4

Desenvolvimento com tinta de nanocarga para aplicação nos estudos da velocidade de corrosão. / Development with nanocarga paint for application in corrosion speed studies.

Gonçalo Siqueira 24 July 2018 (has links)
A corrosão é um dos problemas mais relevantes que afronta a indústria atual, representa mais de 25% do investimento destinado para reparos ou troca de equipamentos com falhas por problemas do ataque corrosivo. Neste panorama nos últimos anos houve um grande aumento no desenvolvimento de novas tecnologias para proteção das estruturas, por outro lado o aço ABTN 1020 é um dos materiais mais usados na indústria principalmente em ambientes contendo cloreto. A sua utilização não é recomendada pelas altas taxas de corrosão, sendo necessário à adoção de pintura como meio de proteção. Este trabalho investigou a resistência à corrosão de uma pintura em meios contendo cloreto cuja composição da matriz foi resina uretânica (PU) e diferentes cargas a base de SiO2 e ZnO em diversas concentrações, sendo avaliadas mediante técnicas de Impedância Eletroquímica- EIS e de varredura com elétrodo vibratório SVET. Verificou-se que a espectroscopia e SVET também fornecem informação suficiente relativo ao desgaste e a possível ação da corrosão, sendo assim foi evidenciado que pintura com carga a base de SiO2 que tem melhor resistência à corrosão em meios contendo cloreto. Em outra análise quando comparados com a carga de ZnO pintura com irradiação, observou-se que houve um aumento na aderência da pintura ao metal base, fornecendo uniformidade e maior proteção anticorrosiva, assim foram determinados parâmetros que podem aplicações na indústria. / Corrosion is one of the most important problems facing today\'s industry, representing more than 25% of the investment destined for repairs or exchange of equipment with failures due to corrosive attack problems. In this panorama in recent years there has been a great increase in the development of new technologies for protection of structures, on the other hand the steel ABTN 1020 is one of the materials most used in the industry mainly in environments containing chloride. Its use is not recommended due to the high corrosion rates, and it is necessary to adopt painting as a means of protection. This work investigated the corrosion resistance of a paint in chloride-containing media whose urethane resin (PU) composition and different SiO2 and ZnO-based loads were evaluated in various concentrations and evaluated by Electrochemical Impedance-EIS and scanning with vibrating electrode SVET. It was verified that the spectroscopy and SVET also provide sufficient information regarding the wear and the possible action of the corrosion, thus it was evidenced that paint with charge based on SiO2 that has better resistance to corrosion in media containing chloride. In another analysis when compared with the ZnO charge with irradiation paint, it was observed that there was an increase in the adhesion of the paint to the base metal, providing uniformity and greater anticorrosive protection, thus determined parameters that can be applied in the industry.

Page generated in 0.0976 seconds