Spelling suggestions: "subject:"proteção ultravioleta"" "subject:"proteção ultravioletas""
1 |
Compostos de terras raras, com alta absortividade no ultravioleta, como agentes de proteção de radiações solares UV-A e UV-B / Rare earth compounds with high absorptivity in uv as protection agents against UVA and UVB solar radiationPeverari, Cinara 07 March 2007 (has links)
A luz do sol possui radiação ultravioleta (UV) que pode ser dividida em luz UVA, com comprimentos de onda na região de 400 a 320 nm; luz UV-B, na região de 320 a 290 nm e luz UV-C para radiações com comprimento de onda menor do que 290 nm, sendo esta última absorvida na atmosfera pelo ozônio. O ser humano dispõe de mecanismos protetores naturais contra as radiações solares, tal como a melanogênese. Entretanto, estes são insuficientes e, por isso, torna-se necessário proteger adequadamente a pele utilizando protetores solares, a fim de minimizar as lesões cutâneas causadas pela radiação solar. Quimicamente, a função dos protetores solares é a absorção da radiação UV, protegendo a pele dos efeitos da exposição à luz solar. Este trabalho visa a preparação de compostos de cério, via método Pechini, com a finalidade de utilizá-los como um componente inorgânico de protetores solares de elevado FPS, juntamente ou substituindo substâncias tais como ZnO e TiO2. A caracterização dos compostos deverá ser realizada por difratometria de raios X, microscopias de eletrônicas de varredura e transmissão, espectroscopia eletrônica de reflectância difusa (ERD) e testes de atividade catalítica e fotocatalítica, pelo método da determinação condutométrica (adaptação RANCIMAT®). / Sunlight emits ultraviolet radiation (UV) which is subdivided into three different UV wavelengths: UV-A band in the range of 400-320 nm; UV-B band in the range of 320-290 nm and UV-C band for radiations lesser than 290 nm. The latter is absorbed in the atmospheres ozone layer. Human beings have natural protective mechanisms against solar radiations, such as melanogenys. However, it has been reported that these mechanisms are insufficient to prevent skin damage. Thus, adequate the use of sunscreen (or UV filters) is needed in order to minimize cutaneous injuries caused by solar radiation. Chemically, the function of solar protectors relies on the absorption of UV radiation, which protects the skin from the effect of the exposition to solar light. The present study reports on the synthesis of CeO2-ZnO systems according to Pechini\'s method. Our objective is to further understand how ZnO modifies the CeO2 nanostructured as we search for a new UV filter material. The characterization of composites will be carried through by X-ray diffraction, transmission electron microscopy (TEM), scanning electron microscopy (SEM), diffuse reflectance spectroscopic and tests of catalytic activity and photocatalytic activity, for the method of the conductometric determination (RANCIMAT adaptation).
|
2 |
Compostos de terras raras, com alta absortividade no ultravioleta, como agentes de proteção de radiações solares UV-A e UV-B / Rare earth compounds with high absorptivity in uv as protection agents against UVA and UVB solar radiationCinara Peverari 07 March 2007 (has links)
A luz do sol possui radiação ultravioleta (UV) que pode ser dividida em luz UVA, com comprimentos de onda na região de 400 a 320 nm; luz UV-B, na região de 320 a 290 nm e luz UV-C para radiações com comprimento de onda menor do que 290 nm, sendo esta última absorvida na atmosfera pelo ozônio. O ser humano dispõe de mecanismos protetores naturais contra as radiações solares, tal como a melanogênese. Entretanto, estes são insuficientes e, por isso, torna-se necessário proteger adequadamente a pele utilizando protetores solares, a fim de minimizar as lesões cutâneas causadas pela radiação solar. Quimicamente, a função dos protetores solares é a absorção da radiação UV, protegendo a pele dos efeitos da exposição à luz solar. Este trabalho visa a preparação de compostos de cério, via método Pechini, com a finalidade de utilizá-los como um componente inorgânico de protetores solares de elevado FPS, juntamente ou substituindo substâncias tais como ZnO e TiO2. A caracterização dos compostos deverá ser realizada por difratometria de raios X, microscopias de eletrônicas de varredura e transmissão, espectroscopia eletrônica de reflectância difusa (ERD) e testes de atividade catalítica e fotocatalítica, pelo método da determinação condutométrica (adaptação RANCIMAT®). / Sunlight emits ultraviolet radiation (UV) which is subdivided into three different UV wavelengths: UV-A band in the range of 400-320 nm; UV-B band in the range of 320-290 nm and UV-C band for radiations lesser than 290 nm. The latter is absorbed in the atmospheres ozone layer. Human beings have natural protective mechanisms against solar radiations, such as melanogenys. However, it has been reported that these mechanisms are insufficient to prevent skin damage. Thus, adequate the use of sunscreen (or UV filters) is needed in order to minimize cutaneous injuries caused by solar radiation. Chemically, the function of solar protectors relies on the absorption of UV radiation, which protects the skin from the effect of the exposition to solar light. The present study reports on the synthesis of CeO2-ZnO systems according to Pechini\'s method. Our objective is to further understand how ZnO modifies the CeO2 nanostructured as we search for a new UV filter material. The characterization of composites will be carried through by X-ray diffraction, transmission electron microscopy (TEM), scanning electron microscopy (SEM), diffuse reflectance spectroscopic and tests of catalytic activity and photocatalytic activity, for the method of the conductometric determination (RANCIMAT adaptation).
|
3 |
Painel automatizado para estudo do efeito da radiação solar natural sobre os óculos de sol / Automated panel to study the effect of natural sunlight on sunglassesGomes, Leonardo Mariano 25 February 2016 (has links)
O objetivo principal deste trabalho foi desenvolver um equipamento capaz de expor as lentes de óculos de sol de maneira automática, de forma que simule o uso do acessório pelas pessoas, por um período equivalente ao tempo de uso de um mesmo modelo pela população brasileira e, através das medidas realizadas nas lentes após a exposição prolongada ao sol, verificar o comportamento da transmitância dos raios pela lente, principalmente dos raios UV, e assim, determinar se as lentes se degradam com o tempo. A partir dos resultados, espera-se complementar os estudos teóricos em desenvolvimento pelos pesquisadores do LIO sobre a equivalência entre os testes em simuladores solares e a exposição real ao sol, colaborando para a adequação dos parâmetros apresentados na norma nacional (NBR ISO 12312-1:2015) e internacional (ISO 12312-1:2013). Os parâmetros utilizados nos testes de certificação da norma nacional são os mesmos dos utilizados na internacional e que foram criados para representar as condições de radiação solar na Europa. Tendo conhecimento dos fatores que influenciam os níveis de radiação UV que atingem a Terra fica evidenciado que estes níveis são maiores nas regiões mais próximas do Brasil do que da Europa. Segundo estudos, uma otimização geográfica da norma brasileira deve ser considerada, levando-se em conta as diferenças nos índices UV do Brasil e da Europa. Além disso, os parâmetros para o teste de resistência à radiação em óculos de sol utilizados no Brasil, devem ser revistos para garantir que as condições simuladas sejam suficientes para garantir a proteção UV para as exposições típicas dos óculos ao Sol. A metodologia consistiu no desenvolvimento do protótipo para exposição automática de lentes de óculos de sol, além do desenvolvimento do sistema de medição do índice UV. Por fim, é descrito o teste realizado com uma miniatura de painel para exposição não controlada das lentes e a técnica e equipamentos utilizados para medição da transmitância luminosa e UV das lentes antes e depois da exposição ao Sol. Este protótipo consiste de uma caixa para proteção dos sistemas mecânicos e eletrônicos, uma tampa automática e um painel de acrílico, o qual acomoda 100 lentes posicionadas na posição de uso, as quais são irradiadas pelo Sol desde o nascer até o seu pôr. A tampa é aberta automaticamente, o painel ejetado, através do sistema mecânico, de dentro da caixa e rotaciona no sentido do Sol, de forma que as lentes sejam sempre irradiadas pela frente. A cada intervalo de 15 minutos, o sistema calcula a posição do Sol a ajusta a direção do painel. Sensores de variáveis climáticas avisam o sistema para fechar a tampa e proteger os óculos de condições indesejáveis. Os resultados deste trabalho consistam na apresentação do protótipo finalizado e funcionando, análise das informação obtidas dos sensores e análise preliminar sobre a variação da transmitância UV e luminosa das lentes de óculos de sol após 150 horas de exposição. É concluído que o período de 150 h não é suficiente para provocar mudanças significativas na características das lentes, portanto o protótipo do painel automatizado será utilizado para exposição a longo prazo e os resultados de pesquisas futuras poderão contribuir para as normas e melhor proteção da saúde ocular da população. / The aim of this work is to develop a device capable of exposing the lenses of sunglasses automatically, so that simulates the use of the accessory for people, for a period equivalent to the time of use of the same model by the Brazilian population and through measurements performed on the lenses after prolonged sun exposure, check the behavior of the transmittance of the rays by the lens, mainly from UV rays, and thus determine if the lenses degrade over time. From the results, it is expected to complement the theoretical studies being developed by LIO researchers on the equivalence in solar simulators tests and actual exposure to the sun, helping to adapt the parameters of the national standard (NBR ISO 12312-1:2015) and international (ISO 12312-1:2013). The parameters used in the certification tests of the national standard are the same as used in international and those were created to represent the solar radiation conditions in Europe. Knowing the factors that influence UV radiation levels reaching the earth is evident that these levels are higher in the nearby regions of Brazil than in Europe. According to studies, a geographical optimization of the Brazilian standard should be considered, taking into account differences in UV indices of Brazil and Europe. Also, the parameters for the radiation resistance test in sunglasses used in Brazil, should be reviewed to ensure that the simulated conditions are sufficient to ensure UV protection for typical exposures of glasses in the sun. The methodology is the development of the prototype for automatic exposure sunglass lenses, and the development of the UV index measuring system. Finally, it is described the test conducted with a miniature panel to expose lens and the technique and equipment used for measuring luminous and UV transmittance of the lenses before and after exposure to the sun. This prototype consists of a box for protection mechanical and electronic systems, automatic cover and an acrylic panel, which accommodates 100 lenses positioned in the use position, which will be irradiated by the sun from sunrise to sunset. The lid will automatically open the panel is ejected through the mechanical system out of the box, and must rotate in the direction of the sun, so that the lens is always irradiated from the front. Every 15-minute interval, the system calculates the position of the sun to set the direction of the panel. Climatic variables sensors alert the system to close the cover and protect the glasses undesirable conditions. The results of this project are to report the finished prototype and running, analysis of the obtained information from the sensors and preliminary analysis of the variation of UV transmittance and light lens sun glasses after 150 hours of exposure. It is concluded that the period of 150 hours is not sufficient to cause significant changes in the characteristics of the lenses, so the automated panel prototype will be used for long-term exposure and the results of future research will contribute to the standards and better protection of eye health of population.
|
4 |
Painel automatizado para estudo do efeito da radiação solar natural sobre os óculos de sol / Automated panel to study the effect of natural sunlight on sunglassesLeonardo Mariano Gomes 25 February 2016 (has links)
O objetivo principal deste trabalho foi desenvolver um equipamento capaz de expor as lentes de óculos de sol de maneira automática, de forma que simule o uso do acessório pelas pessoas, por um período equivalente ao tempo de uso de um mesmo modelo pela população brasileira e, através das medidas realizadas nas lentes após a exposição prolongada ao sol, verificar o comportamento da transmitância dos raios pela lente, principalmente dos raios UV, e assim, determinar se as lentes se degradam com o tempo. A partir dos resultados, espera-se complementar os estudos teóricos em desenvolvimento pelos pesquisadores do LIO sobre a equivalência entre os testes em simuladores solares e a exposição real ao sol, colaborando para a adequação dos parâmetros apresentados na norma nacional (NBR ISO 12312-1:2015) e internacional (ISO 12312-1:2013). Os parâmetros utilizados nos testes de certificação da norma nacional são os mesmos dos utilizados na internacional e que foram criados para representar as condições de radiação solar na Europa. Tendo conhecimento dos fatores que influenciam os níveis de radiação UV que atingem a Terra fica evidenciado que estes níveis são maiores nas regiões mais próximas do Brasil do que da Europa. Segundo estudos, uma otimização geográfica da norma brasileira deve ser considerada, levando-se em conta as diferenças nos índices UV do Brasil e da Europa. Além disso, os parâmetros para o teste de resistência à radiação em óculos de sol utilizados no Brasil, devem ser revistos para garantir que as condições simuladas sejam suficientes para garantir a proteção UV para as exposições típicas dos óculos ao Sol. A metodologia consistiu no desenvolvimento do protótipo para exposição automática de lentes de óculos de sol, além do desenvolvimento do sistema de medição do índice UV. Por fim, é descrito o teste realizado com uma miniatura de painel para exposição não controlada das lentes e a técnica e equipamentos utilizados para medição da transmitância luminosa e UV das lentes antes e depois da exposição ao Sol. Este protótipo consiste de uma caixa para proteção dos sistemas mecânicos e eletrônicos, uma tampa automática e um painel de acrílico, o qual acomoda 100 lentes posicionadas na posição de uso, as quais são irradiadas pelo Sol desde o nascer até o seu pôr. A tampa é aberta automaticamente, o painel ejetado, através do sistema mecânico, de dentro da caixa e rotaciona no sentido do Sol, de forma que as lentes sejam sempre irradiadas pela frente. A cada intervalo de 15 minutos, o sistema calcula a posição do Sol a ajusta a direção do painel. Sensores de variáveis climáticas avisam o sistema para fechar a tampa e proteger os óculos de condições indesejáveis. Os resultados deste trabalho consistam na apresentação do protótipo finalizado e funcionando, análise das informação obtidas dos sensores e análise preliminar sobre a variação da transmitância UV e luminosa das lentes de óculos de sol após 150 horas de exposição. É concluído que o período de 150 h não é suficiente para provocar mudanças significativas na características das lentes, portanto o protótipo do painel automatizado será utilizado para exposição a longo prazo e os resultados de pesquisas futuras poderão contribuir para as normas e melhor proteção da saúde ocular da população. / The aim of this work is to develop a device capable of exposing the lenses of sunglasses automatically, so that simulates the use of the accessory for people, for a period equivalent to the time of use of the same model by the Brazilian population and through measurements performed on the lenses after prolonged sun exposure, check the behavior of the transmittance of the rays by the lens, mainly from UV rays, and thus determine if the lenses degrade over time. From the results, it is expected to complement the theoretical studies being developed by LIO researchers on the equivalence in solar simulators tests and actual exposure to the sun, helping to adapt the parameters of the national standard (NBR ISO 12312-1:2015) and international (ISO 12312-1:2013). The parameters used in the certification tests of the national standard are the same as used in international and those were created to represent the solar radiation conditions in Europe. Knowing the factors that influence UV radiation levels reaching the earth is evident that these levels are higher in the nearby regions of Brazil than in Europe. According to studies, a geographical optimization of the Brazilian standard should be considered, taking into account differences in UV indices of Brazil and Europe. Also, the parameters for the radiation resistance test in sunglasses used in Brazil, should be reviewed to ensure that the simulated conditions are sufficient to ensure UV protection for typical exposures of glasses in the sun. The methodology is the development of the prototype for automatic exposure sunglass lenses, and the development of the UV index measuring system. Finally, it is described the test conducted with a miniature panel to expose lens and the technique and equipment used for measuring luminous and UV transmittance of the lenses before and after exposure to the sun. This prototype consists of a box for protection mechanical and electronic systems, automatic cover and an acrylic panel, which accommodates 100 lenses positioned in the use position, which will be irradiated by the sun from sunrise to sunset. The lid will automatically open the panel is ejected through the mechanical system out of the box, and must rotate in the direction of the sun, so that the lens is always irradiated from the front. Every 15-minute interval, the system calculates the position of the sun to set the direction of the panel. Climatic variables sensors alert the system to close the cover and protect the glasses undesirable conditions. The results of this project are to report the finished prototype and running, analysis of the obtained information from the sensors and preliminary analysis of the variation of UV transmittance and light lens sun glasses after 150 hours of exposure. It is concluded that the period of 150 hours is not sufficient to cause significant changes in the characteristics of the lenses, so the automated panel prototype will be used for long-term exposure and the results of future research will contribute to the standards and better protection of eye health of population.
|
Page generated in 0.0629 seconds