• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do impacto da geração distribuída sobre o sistema de proteção de sobrecorrente de uma rede de distribuição operando em ilhamento intencional / Impact assessment of the distributed generation on the overcurrent protection system of a distribution network operating in intentional islanding

Robson Roberto Sguaçabia 26 March 2015 (has links)
O crescente número de geradores distribuídos conectados em redes de distribuição de energia elétrica é uma realidade dos sistemas elétricos de todo o mundo. Embora a política atual seja desconectar os geradores distribuídos do sistema elétrico de potência (SEP) caso ocorra uma falha na rede da concessionária, conforme preconizam os principais guias técnicos nacionais e internacionais, o módulo 3 dos Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional (PRODIST) mostra-se favorável à operação ilhada, pois afirma que este tipo de operação pode ser realizado em comum acordo entre as centrais geradoras de energia e o Operador Nacional do Sistema Elétrico (ONS), permitindo alcançar uma maior disponibilidade no fornecimento de energia. No entanto, para que a operação ilhada seja possível e possa ser praticada de forma segura, o ilhamento intencional precisa superar alguns desafios, dentre os quais estão aqueles relacionados ao sistema de proteção da rede de distribuição, tais como: coordenação indevida de dispositivos de proteção, perda da sensibilidade da proteção, abertura inadequada de fusíveis e religamentos automáticos fora de sincronismo. Portanto, este trabalho avalia o impacto da geração distribuída (GD) sobre o sistema de proteção de sobrecorrente de uma rede de distribuição operando ilhada. A ideia principal é dividir a rede em regiões delimitadas pelos dispositivos de proteção existentes, para em seguida, adequá-los à nova situação operacional, certificando se os ajustes propostos atendem ao comportamento síncrono e estável do sistema de geração por meio de uma análise de estabilidade transitória. Propõe-se então um conjunto de procedimentos para tomada de ações que permitam readequar o sistema de proteção de sobrecorrente existente à operação ilhada. Os resultados obtidos demonstram que a inibição do religamento automático e da curva de atuação instantânea acrescida de reajustes nas curvas temporizadas dos relés e religadores, melhoraram a coordenação e seletividade da rede operando ilhada. / The growing number of distributed generators connected to electricity distribution networks is a reality of electrical systems throughout the world. Although the current policy is to disconnect the distributed generators from the electric power system (EPS) in the event of loss of mains, as required by main national and international technical guides, the module 3 of the Procedures for Electric Power Distribution in the Electric National System (PRODIST) shows itself in favor of islanded operation, it states that this type of operation can be carried out in agreement between power generation plants and the National Electric System Operator (ONS), allowing achieve larger availability in energy supply. However, to make the islanded operation possible and safe, the intentional islanding must overcome some challenges, among which are those related to the protection system of the distribution network, such as improper coordination of protective devices, loss of protection sensitivity, inadequate opening of fuses and automatic reclosing out of synchronism. Therefore, this work evaluates the impact of distributed generation (DG) on the overcurrent protection system of a distribution network operating islanded. The main idea is to divide the network into regions bounded by existing protection devices, to then adapt them to the new operational situation, making sure that the proposed adjustments meet the synchronous and stable behavior of the generation system by means of a transient stability analysis. Thus, a set of procedures is proposed to indicate actions that allow readjusting the existing overcurrent protection system to the islanded operation. The results demonstrate that the inhibition of automatic restart and of the instantaneous operating curve plus adjustments in time delay curves of relays and reclosers, improved the coordination and selectivity of the network operating islanded.
2

Avaliação do impacto da geração distribuída sobre o sistema de proteção de sobrecorrente de uma rede de distribuição operando em ilhamento intencional / Impact assessment of the distributed generation on the overcurrent protection system of a distribution network operating in intentional islanding

Sguaçabia, Robson Roberto 26 March 2015 (has links)
O crescente número de geradores distribuídos conectados em redes de distribuição de energia elétrica é uma realidade dos sistemas elétricos de todo o mundo. Embora a política atual seja desconectar os geradores distribuídos do sistema elétrico de potência (SEP) caso ocorra uma falha na rede da concessionária, conforme preconizam os principais guias técnicos nacionais e internacionais, o módulo 3 dos Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional (PRODIST) mostra-se favorável à operação ilhada, pois afirma que este tipo de operação pode ser realizado em comum acordo entre as centrais geradoras de energia e o Operador Nacional do Sistema Elétrico (ONS), permitindo alcançar uma maior disponibilidade no fornecimento de energia. No entanto, para que a operação ilhada seja possível e possa ser praticada de forma segura, o ilhamento intencional precisa superar alguns desafios, dentre os quais estão aqueles relacionados ao sistema de proteção da rede de distribuição, tais como: coordenação indevida de dispositivos de proteção, perda da sensibilidade da proteção, abertura inadequada de fusíveis e religamentos automáticos fora de sincronismo. Portanto, este trabalho avalia o impacto da geração distribuída (GD) sobre o sistema de proteção de sobrecorrente de uma rede de distribuição operando ilhada. A ideia principal é dividir a rede em regiões delimitadas pelos dispositivos de proteção existentes, para em seguida, adequá-los à nova situação operacional, certificando se os ajustes propostos atendem ao comportamento síncrono e estável do sistema de geração por meio de uma análise de estabilidade transitória. Propõe-se então um conjunto de procedimentos para tomada de ações que permitam readequar o sistema de proteção de sobrecorrente existente à operação ilhada. Os resultados obtidos demonstram que a inibição do religamento automático e da curva de atuação instantânea acrescida de reajustes nas curvas temporizadas dos relés e religadores, melhoraram a coordenação e seletividade da rede operando ilhada. / The growing number of distributed generators connected to electricity distribution networks is a reality of electrical systems throughout the world. Although the current policy is to disconnect the distributed generators from the electric power system (EPS) in the event of loss of mains, as required by main national and international technical guides, the module 3 of the Procedures for Electric Power Distribution in the Electric National System (PRODIST) shows itself in favor of islanded operation, it states that this type of operation can be carried out in agreement between power generation plants and the National Electric System Operator (ONS), allowing achieve larger availability in energy supply. However, to make the islanded operation possible and safe, the intentional islanding must overcome some challenges, among which are those related to the protection system of the distribution network, such as improper coordination of protective devices, loss of protection sensitivity, inadequate opening of fuses and automatic reclosing out of synchronism. Therefore, this work evaluates the impact of distributed generation (DG) on the overcurrent protection system of a distribution network operating islanded. The main idea is to divide the network into regions bounded by existing protection devices, to then adapt them to the new operational situation, making sure that the proposed adjustments meet the synchronous and stable behavior of the generation system by means of a transient stability analysis. Thus, a set of procedures is proposed to indicate actions that allow readjusting the existing overcurrent protection system to the islanded operation. The results demonstrate that the inhibition of automatic restart and of the instantaneous operating curve plus adjustments in time delay curves of relays and reclosers, improved the coordination and selectivity of the network operating islanded.
3

Análise de alternativas de proteção anti-ilhamento de geradores síncronos distribuídos / Analyzes of alternatives of anti-slanding protection of distributed synchronous generators

Mota, Igor Lopes 18 September 2015 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-03-24T19:57:30Z No. of bitstreams: 2 Dissertação - Igor Lopes Mota - 2015.pdf: 2620143 bytes, checksum: c895dad8e571f14172d9b7e9506f3d94 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-03-28T11:35:07Z (GMT) No. of bitstreams: 2 Dissertação - Igor Lopes Mota - 2015.pdf: 2620143 bytes, checksum: c895dad8e571f14172d9b7e9506f3d94 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-03-28T11:35:07Z (GMT). No. of bitstreams: 2 Dissertação - Igor Lopes Mota - 2015.pdf: 2620143 bytes, checksum: c895dad8e571f14172d9b7e9506f3d94 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2015-09-18 / In this dissertation, we present a detailed study of techniques for islanding detection of distribution systems in the presence of distributed generators in various forms of access and connection. The aim is to set up protection system solutions capable of ensuring the detection of the islanding based on local passive techniques, which have lower costs with respect to remote techniques, for example, the transfer trip. The objective of this work is to achieve through the association of several islanding detection techniques in order to achieve adequate reliability of distributed synchronous generators protection system. Among the existing techniques, the protection functions studied were the overfrequency and underfrequency (ANSI 81 o/u), rate of change of frequency (ROCOF or ANSI 81 df/dt), vector jump (ANSI 78) and directional reactive power (ANSI 32Q). It was found that the 32Q function for loads with inductive power factor less than one complements the functions based on frequency precisely in the range where these are insensitive to islanding, wherein the threshold for operation of this relay depends on the equivalent load power consumed locally. For cases of islanding caused the intentional opening of the distribution feeder, the islanding detection for loads with a inductive power factor can be guaranteed with the use of passive local techniques without the need to burden the installation of synchronous generators protection systems distributed. Although in practice it is very unlikely a distribution circuit has a unity power factor, the association of these protective functions arises as a good solution for the detection of islanding of distributed synchronous generators. / Nesta dissertação de mestrado apresenta-se um estudo das principais técnicas de detecção de ilhamento de geradores distribuídos considerando dados reais de 3 acessantes com diferentes capacidades de geração e diferentes tensões de conexão com o sistema interligado. Visa definir soluções de composição de sistemas de proteção capazes de garantir a detecção do ilhamento baseados em técnicas locais passivas, que apresentam custos mais reduzidos com relação às técnicas remotas, como por exemplo, a teleproteção. O objetivo deste trabalho é alcançar, por meio de associação de várias técnicas de detecção de ilhamento, um grau de confiabilidade adequado do sistema de proteção de geradores síncronos distribuídos. Dentre as técnicas existentes, foram estudadas as funções de proteção de sub e sobrefrequência (ANSI 81 o/u), taxa de variação de frequência (ROCOF ou ANSI 81 df/dt), salto de vetor (ANSI 78) e direcional de potência reativa (ANSI 32Q). Constatouse que a função 32Q, para cargas com fator de potência indutivo e menor que um, complementa as funções baseadas em frequência justamente na faixa onde estas são insensíveis a ilhamentos, sendo que o limite para a operação deste relé depende da potência equivalente da carga consumida localmente. Para os casos de ilhamento provocado pela abertura intencional do alimentador de distribuição, a detecção de ilhamento para cargas com fator de potência indutivo poderá ser garantida com a utilização das técnicas locais passivas sem a necessidade de se onerar a instalação dos sistemas de proteção de geradores síncronos distribuídos. Apesar de que na prática é muito improvável um circuito de distribuição possuir um fator de potência unitário, a associação das referidas funções de proteção surge como uma boa solução para a detecção de ilhamentos de geradores síncronos distribuídos.

Page generated in 0.1242 seconds