111

Vývoj progresivního kotevního materiálu na polymerní bázi / Development of progressive polymer anchor material

Žlebek, Tomáš January 2017 (has links)
The diploma thesis deals with development of a new progressive anchor material on the polymer base. Nowadays, it is effort to utilize secondary raw materials in building industry as much as possible both from an environmental aspects in order to save primary energy sources and the reduction of waste and also due to economic reasons. Therefore, there is an effort to utilize high amount of suitable and appropriately treated secondary raw materials into the anchor materials. The main aim of this work is to develop high quality anchor material characterized by excellent ratio between speed and strength growth, high chemical resistance, thermal resistance and particularly minimal shrinkage. This new material is designed especially for anchoring building structures heavy machines steel barriers and other elements.
112

Investigation on jute fibres and their composites based on polypropylene and epoxy matrices

Doan, Thi Thu Loan 19 May 2006 (has links)
- Matrix modification of jute/polypropylene composites with MAHgPP - Fibre surface modification for epoxy/jute composites, including: NaOH treatment, silane coupling agents, epoxy dispersion and their combinations - Investigation the influence of modification on the performance of jute fibre and jute compostites. / Untersuchungen zum mechanischen und thermischen Verhalten sowie zur Benetzung von Jute­fasern im Ausgangszustand, nach Entwachsen und nach Oberflächenmodifikation, mit dem Ziel einer Verwendung als Verstärkungsfasern in Verbundwerkstoffen. Untersuchungen zum mechanischen und thermischen Verhalten sowie zur hygrothermischen Alterung von Jute/Polypropylen (PP) Verbunden. Einfluss des PP-Typs, der Modifizierung der Matrix mit Maleinsäureanhydrid gepfropftem PP und des Faservolumengehalts.Untersuchung der Grenzschicht in Jute/Epoxidharz Verbunden in Hinblick auf die mechanischen Eigenschaften nach Alkalibehandlung und Oberflächenmodifikation der Jutefasern. Jutefasern haben gute spezifische mechanische Eigenschaften. Die Einzelfasereigenschaften unterliegen der bei Naturfasern üblichen Streuung der mechanischen Eigenschaften. Im Gegensatz zu konventionellen Verstärkungsfasern (Glas, Carbon) nimmt wachstumsbedingt mit zunehmendem Faserquerschnitt die Festigkeit tendenziell zu. Faseroberflächenbehandlungen verbessern die Benetzbarkeit, erhöhen die thermische Stabilität und reduzieren die Feuchteaufnahme sowie den Diffusionskoeffizient. Jute/Polypropylen-Verbunde Chemische und physikalische Wechselwirkungen zwischen Faser und MAHgPP nach optimierter Kopplerauswahl verbessern in Abhängigkeit vom PP-Typ die Grenzflächenscherfestigkeit und die mechanischen Eigenschaften. Durch Einbeziehen der Grenzflächeneigenschaften können mit einer modifizierten Mischungsregel die Zugfestigkeiten der Verbunde beschrieben werden. Jute/Epoxidharz-Verbunde Faseroberflächenbehandlungen mit Natronlauge, Organosilanen, Epoxiddispersionen und deren Kombinationen führen zu verbesserter Benetzung, reduzierter Wasseraufnahme und verbesserter Haftung sowie verbesserten mechanischen Eigenschaften in Jute/Epoxidharz-Verbunden.
113

Ermüdung des Verbundes von Stahlbeton unter Querzug

Lindorf, Alexander 01 December 2011 (has links)
Im Mittelpunkt der vorliegenden Arbeit steht die gezielte Analyse des Verbundverhaltens zwischen Bewehrungsstahl und Beton unter kombinierter Beanspruchung aus Ermüdung und Querzug. Den Hintergrund bilden Stahlbetonbauteile, wie z. B. Fahrbahnplatten von Verbundbrücken, welche einen zweiaxialen Lastabtrag unter nicht vorwiegend ruhenden Belastungen aufweisen. Die Untersuchungen für normal- und hochfesten Beton erfolgten an Ausziehkörpern mit einem durch Querzugspannungen hervorgerufenen Längsriss entlang des Bewehrungsstabes. Das Versuchsprogramm beinhaltete hochzyklische Schwellversuche mit unterschiedlichen Schwingspielen und variierenden Längsrissbreiten bis zu einer Million Lastwechseln. Anhand der Entwicklung des Schlupfes zwischen Bewehrungsstab und Beton konnte eine deutliche Abhängigkeit des Verbundwiderstandes vom Querzug beobachtet werden. Aufbauend auf der Schlupfentwicklung erfolgt die Ableitung von normierten Wöhlerlinien der Verbundermüdung. Diese Wöhlerlinien können direkt in Beziehung zu den Wöhlerlinien der Betonstahlermüdung gesetzt werden und vereinfachen die Erstellung von Dauerfestigkeitsdiagrammen für Bemessungszwecke. Es wird deutlich, dass die Ermüdungsfestigkeit des Verbundes durch das Vorhandensein eines Längsrisses gegenüber der Betonstahlermüdung verstärkt an Bedeutung gewinnt. / The main focus of the present work is the specific analysis of the bond behaviour between reinforcement and concrete under combined loading due to fatigue and transverse tension. The background is formed by reinforced concrete elements such as bridge decks of steel-concrete composite bridges, which show a biaxial load bearing behaviour under not predominantly monotonic loading. The investigations for both normal strength and high performance concrete were conducted on pull-out specimens with a longitudinal crack along the reinforcing bar caused by transverse tensile stresses. The experimental program included high cyclic tests with different stress ranges and varying longitudinal crack widths up to one million load cycles. By means of the slip development, a definite dependency of the bond strength on the transverse tension could be observed. Based on the slip development, normalised S-N curves for bond fatigue have been deduced. These S-N curves can be set in direct relation to the S-N curves for steel fatigue and simplify creating constant life diagrams for design purposes. It becomes clear that the bond fatigue strength, due to an existing longitudinal crack, gains in importance in comparison to the fatigue strength of the reinforcing steel.
114

Berechnungsalgorithmus zur Bestimmung der Verankerungslänge der textilen Bewehrung in der Feinbetonmatrix

Lorenz, Enrico, Ortlepp, Regine 03 June 2009 (has links)
Dieser Beitrag befasst sich mit der experimentellen und analytischen Bestimmung der Verankerungslängen textiler Bewehrungsstrukturen einer Textilbetonverstärkungsschicht. Die experimentelle Untersuchung des Verbundverhaltens erfolgte anhand von Pull-Out-Versuchen. Die analytische Betrachtung des Verbundproblems geschieht aufbauend auf multilinearen Lösungen der Verbunddifferentialgleichung anhand der experimentell ermittelten Kraft- Rissöffnungs-Beziehungen. Mit Hilfe eines separaten Modells wird aus der so ermittelten Verbundspannungs-Schlupf-Beziehung (VSB) die zur Verankerung einer entsprechenden Kraft F erforderliche Verankerungslänge lE bestimmt. Die Überprüfung der Berechnung erfolgt anhand von unabhängig in experimentellen Versuchen zur Bestimmung der Verankerungslänge ermittelten Werten. Es konnte eine gute Übereinstimmung der berechneten mit den versuchstechnisch bestimmten Verankerungslängen festgestellt werden.
115

Test av förankringar för sandwichelement - en jämförelse mellan två kopplingssystem av glasfiber / Test of anchors in sandwich elements - a comparison between two glass fiber connection systems

Werngren Karlsson, Robin, Carhuallanqui Obregon, Paul Ericson January 2022 (has links)
Prefabricerade sandwichelement kommer att produceras till Linnéskolan i Älmhult av Torps Byggelement AB. Ett sandwichelement består av två lager betong (fasad och bärande skikt) med isolering mellan de två skikten. Dessa sandwichelement hade till en början förankringssystemet Thermopin tillverkade av B.T. Innovation, men på grund av produktion- och leveransproblem så ersattes detta förankringssystem mot Isolink som tillverkas av Schöck. Isolink och Thermopin är två förankringssystem tillverkade av glasfiberarmerade plaststänger (GFRP). Sandwichelementen som kommer att användas i Linnéskolan använder sig av isoleringen Kooltherm tillverkad av Kingspan. I detta arbete jämförs förankringssystemens bärförmågor i form av utdragskapacitet. Beräkningar för kapacitet mot vidhäftningsbrott, utdragsbrott och brott i stångmaterial görs för de båda systemen. Utöver detta testas även bärförmågan i form av utdragskapacitet för isolering Kooltherm. 12 testprover, som tillverkades och levererades av Torps Byggelement AB, utsätts för utdragslaster till brott uppstod. Endast de förankringssystem som bär vinkelrät mot skikten testades. De 12 testproverna var uppdelade på följande vis: Fyra tester med Thermopin, fyra tester med Isolink samt fyra tester med endast isoleringen Kooltherm. De testprover med Isolink-systemet gav ett utdragsbrott vid 18.9 kN. Thermopin gav ett spjälkningsbrott vid 14.9 kN. Kooltherm gav brott i isoleringen vid 1.3 kN. Då Isolink fick ett vidhäftningsbrott är det viktigt med en god vidhäftning mellan förankringssystemet och omkringliggande betong. Vibrering av betongen i flera steg vid användning av Isolink kan därför anses vara viktig. Thermopin fick ett spjälkningsbrott då tillverkarens minsta avstånd till kant inte uppfylldes med testproverna. Det går med stor sannolikhet att säga att Thermopin inte hade fått ett utdragsbrott även om minsta avstånd till kant uppfylldes, mest troligt är att ett konbrott hade uppstått. / Prefabricated sandwich elements will be produced to Linnéskolan in Älmhult by Torps Byggelement AB. A sandwich element is built up by two layers of concrete (facade- and load bearing layer) with insulation separating the two layers. These sandwich elements were intended to have the anchors Thermopin produced by B.T. Innovation but due to delivery problems, this connection system was replaced with Isolink made by Schöck. Isolink and Thermopin are two anchors consisting of glass fiber reinforced plastic bars (GFRP). The sandwich elements that will be used in Linnéskolan will have the insulation Kooltherm made by Kingspan. This work is comparing the two connection systems in load bearing capacity by pull-out load tests. Calculations for pull-out failure, concrete failure and anchor failure were done for both of the connection systems. The load bearing capacity was also to be checked for the Kooltherm insulation by pull-out load tests. 12 test specimens were manufactured and delivered by Torps Byggelement AB. Only the anchors perpendicular to the concrete layers were tested. The 12 test specimens were divided as follows: four tests with Thermopin, four tests with Isolink and four tests without a connection system with only the Kooltherm insulation. The test specimens with Isolink gave a pull-out load at 18.9 kN. Thermopin gave a splitting failure at 14.9 kN. Kooltherm insulation gave a failure in the insulation at 1.3 kN. Due to Isolink getting a pull-out load failure, it is important that the bond between the anchor and the surrounding concrete is strong. Compacting of the concrete in multiple steps when using the Isolink-system can be considered important. The test specimens with the Thermopin-system got a splitting failure due to the manufacturers requirement on minimum edge distance not being achieved in the test specimens. It is proper to state that it is very unlikely that a pull-out failure would occur in the Thermopin test specimens even if the minimum edge distance was achieved. Most likely a concrete-cone failure would have occurred.
116

Tensile behavior of high-performance cement-based composites with hybrid reinforcement subjected to quasi-static and impact loading

Gong, Ting 17 February 2021 (has links)
Hochduktile Betone (Engl.: Strain-Hardening Cement-based Composites – SHCC) und Textilbetone (engl.: Textile Reinforced Concrete – TRC) sind zwei neuartige Faserbetone, die ein duktiles und dehnungsverfestigendes Zugverhalten aufweisen. SHCC bestehen aus feinkörnigen Zementmatrizen und kurzen Hochleistungspolymerfasern, während TRC eine Kombination aus feinkörnigen Zementmatrizen und kontinuierlichen zwei- oder dreidimensionalen Textilschichten darstellt. Letztere bestehen aus Multifilamentgarnen aus Kohlenstoff, alkalibeständigem Glas oder Polymerfasern. Die hohe elastische Verformbarkeit beider Verbundwerkstoffe bis zum Erreichen der Zugfestigkeit entsteht aus der sukzessiven Bildung multipler feiner Risse. Neben der hervorragenden Risskontrolle und Duktilität weisen diese Verbundwerkstoffe ein hohes Energieabsorptionsvermögen auf, was in Bezug auf kurzzeitdynamische Belastungen eine durchaus erstrebenswerte Eigenschaft darstellt. Obwohl SHCC eine höhere Dehnungskapazität als herkömmliche TRC zeigen, weisen die Textilbetone eine erheblich höhere Zugfestigkeit auf. Darüber hinaus besitzen die textilbewehrten Betone deutlich niedrigere Einflüsse von Anwendungstechnologie und Maßstab auf das Zugverhalten, d. h. eine bessere Robustheit. Daher stellt die Kombination dieser beiden Bewehrungskonzepte einen vielversprechenden Ansatz dar. Während die Kurzfasern für eine bessere Risskontrolle und Erstrissfestigkeit sorgen, sichern die Textilgelege eine hohe Zugfestigkeit sowie Steifigkeit im gerissenen Zustand und eine gleichmäßige Verteilung der Kräfte in der Verstärkungsschicht bzw. im Bauteil. Dieser synergetische Effekt kann jedoch nur durch eine zielgerichtete Materialentwicklung erreicht werden, die eine grundlegende Materialcharakterisierung unter verschiedenen Belastungsszenarien erfordert. Im Rahmen des DFG-finanzierten Graduiertenkollegs GRK 2250 „Impaktsicherheit von Baukonstruktionen durch mineralisch gebundene Komposite“ werden duktile und Impakt resistente Komposite entwickelt, charakterisiert und erprobt, die als dünne Verstärkungsschichten auf bestehende Konstruktionen bzw. Bauelemente aufgetragen werden und dadurch deren Widerstandsfähigkeit und Resilienz gegen extreme kurzzeitdynamische Beanspruchungen signifikant erhöhen. Die in der vorliegenden Arbeit vorgestellten Ergebnisse wurden im Rahmen des A3-Projektes innerhalb des GRK 2250/1 erzielt. Ziel dieser Arbeit war es, die grundlegenden mechanischen Eigenschaften und die Dehnratenabhängigkeit von mineralisch gebundenen Kompositen mit hybrider Faserbewehrung zu erfassen und zu beschreiben. Das Forschungskonzept besteht aus systematischen und parametrischen Untersuchungen der einzelnen Komponenten (Faser, Textil, zementgebundene Matrix), ihres Verbundes und der entsprechenden Verbundwerkstoffe. Hierfür wurden zweckbestimmte Prüfkonfigurationen und dreidimensionale Messverfahren angewandt, die in anderen Projekten des GRK 2250/1 entwickelt wurden. Außer uniaxialen, quasistatischen und dynamischen Zugversuchen wurden quasistatische und dynamische Einzelgarnauszugsversuche durchgeführt. Die wichtigsten untersuchten Materialparameter waren die Art der Kurzfaserbewehrung und der Textilien (Material, geometrische und Oberflächeneigenschaften, Art der Tränkung usw.). Auf Basis der mechanischen Experimente wurde ein analytisches Modell eingesetzt und angepasst, dass das Zugverhalten solcher Komposite in Abhängigkeit von verschiedenen Materialparametern abbilden soll. Zusätzlich zu der detaillierten Beschreibung der Materialeigenschaften, der maßgebenden Mechanismen und synergetischen Effekte bilden die erzielten Ergebnisse eine umfangreiche experimentelle Basis für eine empirische und Modell gestützte Weiterentwicklung und Optimierung dieser Verbundwerkstoffe mit Hinblick auf wirtschaftliche und ökonomische Aspekte. / Strain-hardening cement-based composites (SHCC) and textile-reinforced concrete (TRC) are two novel types of fiber-reinforced cementitious composites that exhibit ductile, strain-hardening tensile behavior. SHCC comprises fine-grained cementitious matrices and short, high-performance polymer fiber, while TRC is a combination of a fine-grained, cementitious matrix and continuous two- or three- dimensional textile layers of multi-filament yarns, usually made of carbon or alkali-resistant glass. Both composites yield high inelastic deformations in a strain-hardening phase due to the successive formation of multiple fine cracks. Such cracking behavior stands for high energy absorption of the composites when exposed to extreme loading, without abrupt loss of load-bearing capacity. In comparative terms, SHCC shows superior strain capacity, while TRC yields considerably higher tensile strength. The addition of short fibers strengthens the matrix by efficiently restraining the micro-cracks’ growth and reducing spallation, while the textile reinforcement ensures a secure confinement of the reinforced concrete element (substrate to be strengthened), as well as a favorable stress distribution. The combination of SHCC and textile reinforcement is expected to deliver high tensile strength and stiffness in the strain-hardening stage along with pronounced multiple cracking. In order to achieve a favorable synergetic effect, a purposeful material design is required based on a clear understanding of the mechanical interactions in the composites. In the framework of the DFG Research Training Group GRK 2250, which aims at enhancing structural impact safety through thin strengthening layers made of high-performance mineral-based composites, this work focuses on developing hybrid fiber-reinforced cementitious materials to be applied on the impact rear side. The development concept builds upon a systematic investigation of various aspects of the mechanical behaviors of SHCC and textile at quasi-static and impact strain rates, including the bond properties of fiber to matrix and textile to matrix. Accordingly, uniaxial quasi-static tension tests were first performed on SHCC, bare textile, and hybrid-reinforced composite specimens. The parameters under investigation were types of short fiber and textile reinforcements, reinforcing the ratio for textile as well as bond properties between textile and the surrounding SHCC. Furthermore, impact tension tests were performed to study the strain rate effect on the synergetic composite response. Finally, single-yarn pull-out tests were carried out under both quasi-static and impact loading rates to supplement the comparative assessment of the hybrid fiber-reinforced composites. These tests yielded shear strength-related parameters for quantifying the bond properties of different materials, which were then used as input of the analytical model developed to describe the mechanics of crack propagation and tension stiffening effect of textile-reinforced composites without short fibers. This model is the first step towards a comprehensive analytical description of the tensile behavior of hybrid fiber-reinforced composites based on the experimental data and input parameters attained through the work at hand.
117

Crack-bridging behaviour of polymer fibres in Strain-Hardening Cement-based Composites (SHCC) subject to alternating tension-compression cyclic loading

Ranjbarian, Majid 09 December 2021 (has links)
Concrete is undoubtedly the most important construction material, with widespread applications worldwide. Despite its many advantages, however, concrete exhibits low tensile strength and tends toward brittle failure. The most promising approach for improvement of its tensile properties is the addition of fibres. By addition of only one or two percent of high-performance polymer fibres to a cementitious matrix, strain-hardening can be developed under uniaxial tensile loading. Such materials yield multiple cracking and permit large inelastic deformation in a hardening regime, for which they are usually called Strain-Hardening Cement-based Composites (SHCC). However, the behaviour of SHCC depends on loading conditions, where the most critical case is cyclic loading in tension-compression regimes, in which the ductile properties of the composite can be lost after only several hundred cycles due to degradation of the fibre bridging capacity. The thesis at hand presents the results of experimental investigations into the crack-bridging behaviour of polymer fibres in SHCC subject to alternating tension-compression loading regimes. The investigations covered monotonic loading as well. The experimental programme included fibre tension tests; single-sided, single fibre pull-out tests; double-sided, single and multiple fibre pull-out tests; and microscopic analysis of the specimens after testing. The bridging and pull-out behaviour of single PVA fibres embedded in cement-based matrices were comprehensively characterised and described by a new model. The Locking Front Model explains different interaction phenomena between fibre and matrix after full de-bonding. Furthermore, the interaction and damage mechanisms under cyclic loading were understood. The damage types depend on various parameters such as fibre inclination angle to the crack plane. Above all, however, the deterioration of bridging capacity results from the damage of the fibres between the crack faces in alternating tension-compression regime. The severity of damage is mostly determined by the number of cycles, compressive stress level, and crack width. The results of the experimental investigations at the micro- and meso-levels were analysed further to establish a multi-scale approach for describing the behaviour of a single crack in the composite. The Non-Simultaneity Hypothesis is proposed, which suggests that the crucial events of fibre bridging action may occur non-simultaneously with increasing crack opening displacement, and the bridging parameters may be reliably determined based on the overall behaviour of a group of specimens. Additionally, the Three-Stage Micromechanics-based Model is developed to describe the bridging behaviour of the fibres with different embedded lengths. The parameters of the model were obtained according to the overall bridging behaviour and the Non-Simultaneity Hypothesis. The parameters were validated by comparing prediction with experiment and observation of bridging behaviour in the tests with varied embedded lengths and multiple fibres. In the framework of the novel concept Criterion-Dependent Reference Volume (CDRV), the effective volume fractions of the fibres assuming non-uniform distribution of the fibres were determined over the length of a hypothetical specimen. The behaviour of a single crack was then predicted at the composite level and compared to the equivalent experimental results. The whole multi-scale approach manifests a considerable capability for analysing the behaviour of Fibre-Reinforced, Cement-based Composite (FRCC). Finally, the concept of Representative Continuum with Predetermined Cracking Sequence (RCPCS) is briefly explained for describing the stress-strain behaviour of SHCC in further development of the multi-scale approach. / Beton ist weltweit mit seinen vielfältigen Anwendungsmöglichkeiten zweifelsohne der wichtigste Baustoff. Trotz der vielen Vorteile weist der Beton eine niedrige Zugfestigkeit und ein sprödes Versagen auf. Eine vielversprechende Methode zur Verbesserung dieser stellt seine Bewehrung mit Kurzfasern dar. Mit lediglich ein oder zwei Volumengehalt Prozent von Hochleistungspolymerfasern könnte das Dehnungs-Verfestigungsverhalten (engl.: Strain-hardening behaviour) unter einachsiger Zugbelastung erreicht werden. Allerdings ist das Verhalten des SHCC (engl.: Strain-Hardening Cementitious Composite) abhängig von dem Belastungsregime. Am kritischsten ist das zyklische Zug-Druck-Wechselbelastungsregime, denn dadurch wird kein duktiles Verhalten nach nur mehreren hundert Zyklen möglich sein, weil eine starke Degradation des Faserüberbrückungsvermögens stattfindet. Diese Dissertation beschreibt die Ergebnisse von experimentellen Untersuchungen des Überbrückungsverhaltens der Polymerfasern in SHCC mit dem Schwerpunkt Zug-Druck-Wechselbelastung. Außerdem umfassen die Untersuchungen monotone Belastung. Das experimentelle Programm enthält Faserzugversuche, einseitige- und zweiseitige Einzelfaserauszugsversuche sowie mikroskopische Analysen an den Probekörpern nach den Experimenten. Das Überbrückungs- und Auszugsverhalten der einzelnen PVA-Faser eingebettet in einer zementbasierten Matrix wurden ausführlich charakterisiert und mit einem neuen Modell beschrieben. Das „Locking Front Model“ erläutert spezifische Phänomene des Zusammenspiels der PVA-Faser und Matrix nach der vollen Ablösung. Zusätzlich wurden die Mechanismen der Zusammenwirkung und Schädigungen unter zyklischer Belastung dargestellt. Die Schädigungsarten sind abhängig von den verschiedenen Parametern wie z. B. Faserwinkel zur Rissebene. Vor allem resultierte die Verschlechterung der Überbrückungseigenschaften aus den Schädigungen der Faser zwischen den Rissebenen im Zug-Druck-Wechselbelastungsregime. Die Intensität der Schädigungen ist meistens mit Zyklenanzahl, zyklischer Druckbelastung und Rissbreiten korreliert. Die Ergebnisse der experimentellen Untersuchungen auf der Mikro- sowie Mesoebene wurden weiter ausgewertet, um einen Multiskalenansatz zur Bestimmung des Verhaltens eines einzelnen Risses im Werkstoff zu schaffen. Die „Non-Simultaneity Hypothese“ wurde vorgeschlagen, welche aussagt, den entscheidenden Vorgänge des Überbrückungsverhaltens der Fasern möglicherweise nicht gleichzeitig bei Vergrößerung der Rissöffnung auftreten. Deswegen sollten die Überbrückungsparameter am besten basierend auf dem allgemeinen Verhalten von vielen Proben in einer Gruppe bestimmt werden. Außerdem wurde das „Three-Stage Model“ zur Bestimmung des Überbrückungsverhaltens der Fasern mit verschiedenen Einbettungslängen entwickelt. Die Parameter des Modells wurden basierend auf dem allgemeinen Überbrückungsverhalten und der „Non-Simultaneity Hypothese“ bestimmt. Dann werden diese Parameter mit dem Überbrückungsverhalten anderer Einbettungslängen oder multipellen Fasern validiert. Im Rahmen des neuen Konzeptes, „Criterion-Dependent Reference Volume (CDRV)“, werden der effektive Volumenanteil der Faser in der Länge einer hypothetischen Probe aus Faserbeton mit ungleichmäßiger Faserverteilung bestimmt. Das Verhalten eines einzelnen Risses wird dann auf der Werkstoffebene bestimmt und mit den experimentellen Ergebnissen verglichen. Der gesamte Multiskalenansatz manifestiert wesentliche Fähigkeit zur Analyse des Verhaltens von Faserbeton. Schließlich wird ein neues Konzept, „Representative Continuum with Predetermined Cracking Sequence (RCPCS)“, zur Bestimmung der Spannungs-Dehnungsbeziehung des hochduktilen Betons (SHCC) als zukünftige Entwicklungsmöglichkeit des vorliegenden Multiskalenansatzes kurz vorgestellt.
118

Der Einfluss von Querzug auf den Verbund zwischen Beton und Betonstahl

Ritter, Laura 28 November 2013 (has links)
Der Verbundwerkstoff Stahlbeton zeichnet sich durch das effektive Zusammenwirken seiner beiden Einzelkomponenten Stahl und Beton aus. Dieses wiederum kann nur durch ausreichend gute Verbundbedingungen zwischen beiden Baustoffen gewährleistet werden. Die Verbundeigenschaften werden von zahlreichen Faktoren beeinflusst, zu denen u.a. die Oberflächenprofilierung des Stahls, die Betonfestigkeit und die Umschnürungswirkung durch den umgebenden Beton oder eine Querbewehrung zählen. Auch eine quer zum Stab angreifende Belastung kann einen erheblichen Einfluss auf den Verbundmechanismus und die Verbundversagensart haben. Bei Stahlbetonbauteilen unter einer zweiaxialen Zugbelastung, wie sie z.B. in Behälterwänden oder zweiachsig gespannten Platten auftritt, unterliegt die Bewehrung sowohl einer Längszug- als auch einer Querzugbeanspruchung. Im Rahmen der vorliegenden Arbeit wurde der Einfluss einer Querzugbelastung auf das Verbundverhalten zwischen Rippenstählen und Normalbeton mit Hilfe von würfelförmigen Ausziehkörpern mit einer kurzen Verbundlänge untersucht. Dabei lag das Querzugniveau stets unterhalb der Risslast des Betons, so dass keine Risse entlang des einbetonierten Stabes auftraten. Neben der Höhe der Querzugbelastung wurden im Versuchsprogramm die Betonfestigkeit, der Stabdurchmesser und die Betondeckung variiert. Anhand der Versuchsergebnisse konnte gezeigt werden, dass sich auch unter einer Querzugbelastung der Verlauf der Verbundspannungs-Schlupf-Beziehung nicht ändert. Die Art des Verbundversagens wird jedoch maßgeblich durch den Querzug beeinflusst, welcher ein Spaltbruchversagen in jedem Fall begünstigt. Mit steigendem Querzug tritt auch bei großen Betondeckungen statt eines Ausziehversagens ein Spaltbruchversagen ein. Mittels des vorgeschlagenen Berechnungsmodells können in Abhängigkeit des Querzugniveaus und der Größe der Betondeckung Grenzlinien für den Wechsel im Verbundversagensmodus bestimmt werden. Hierbei wurde ebenfalls der Einfluss der Probekörpergeometrie auf die Versuchsergebnisse in die Berechnung einbezogen, so dass die angegebenen Grenzlinien auch für reale Einbettungslängen der Bewehrung gelten. Weiterhin wurde anhand der Versuchsdaten sowie eines Datensatzes aus der Literatur ein Verbundmodell für kurze Verbundlängen entwickelt, das den Einfluss der bezogenen Rippenfläche der Bewehrung und der Betonfestigkeit sowohl auf die Verbundspannungen als auch auf die zugehörigen Schlupfwerte berücksichtigt. Über einen zusätzlichen Datensatz zum Einfluss der Verbundlänge im Ausziehversuch konnte ebenfalls die Abhängigkeit zwischen den mittleren Verbundspannungen, den zugehörigen Schlupfwerten und der Verbundlänge spezifiziert werden. Somit ist eine Übertragbarkeit der Ergebnisse von Ausziehversuchen mit kurzen Verbundlängen auf eine reale Einbettungslänge im Bauteil möglich. Für die Bemessung von Stahlbetonkonstruktionen in den Grenzzuständen der Tragfähigkeit und der Gebrauchstauglichkeit erfolgt die Ableitung geeigneter Verformungskriterien für die Relativverschiebung zwischen Betonstahl und Beton und deren Verifizierung an Versuchsdaten aus der Literatur. Die aufgestellten Verformungskriterien in Abhängigkeit der Stahlspannung erlauben eine direkte Ermittlung bemessungsrelevanter Verbundspannungen anhand experimenteller Ausziehversuche. Die Berücksichtigung einer Querzugbelastung ist dabei in allen vorgestellten Berechnungsansätzen ebenfalls möglich. / Reinforced concrete as composite material is characterised by an effective interaction of its individual components reinforcing steel and concrete. This only can be assured by adequate bond conditions between these two materials. The bond quality is influenced by a wide range of parameters, amongst others including the rib geometry of the bar, the concrete strength and the confining action by the surrounding concrete or transverse reinforcement. Moreover loads, which act transverse to the reinforcing bar, can influence the bond mechanism and the bond failure mode significantly. Reinforced concrete structures, such as containment walls or two-way slabs, are often exposed to multiaxial loading conditions. In case of biaxial tensile stresses, reinforcement and surrounding concrete are loaded in tension in longitudinal as well as in transverse direction. An extensive experimental program was carried out in order to investigate the bond behaviour between reinforcing steel and normal strength concrete due to transverse tension. Cubic-shaped pullout specimens with a short bond length were used. The transverse tension level remained always below the cracking stress of concrete, meaning that no crack occurred along the pullout bar. The test program contained the variation of the transverse tension level, the concrete strength, the bar diameter and the concrete cover. From the test results no systematic influence of the transverse tension level on the shape of the bond stress-slip-relationship can be detected. The bond failure mode is significantly influenced by transverse tension, which promotes splitting failure. The higher the transverse tension level, even for high concrete covers, splitting failure occurs instead of pulling out the bar. From the test results, a failure criterion depending on the concrete cover and the transverse tension level could be determined, which indicates the failure mode and corresponding bond stress. For this purpose, the influence of the specimen geometry on the test results was considered, which results in a failure criterion that is also valid for real embedment lengths of the reinforcement. Furthermore, a bond model for short bond lengths has been developed, based on the test results and a dataset from literature. The model considers the influence of the related rib area of the reinforcing bar and the concrete strength on the bond stresses as well as on the corresponding slip values. By an additional dataset concerning the influence of bond length in pullout tests, the bond stresses and corresponding slip values could be specified as a function of the bond length. Therefore, the test results of pullout test with short bond lengths are transferable to real embedment lengths in structural elements. For the structural design of reinforced concrete elements in the ultimate and serviceability limit states, appli\\-cable deformation criterions concerning the relative displacement between reinforcing steel and concrete has been derived and verified by test data from literature. By means of the developed deformations criterions dependent on the steel stress, design bond stresses can be determined directly from experimental pullout tests. The consideration of transverse tensile loads is also possible for all presented design formulas.
119

Numerical simulation of geomembranes at large deformations

Nguyen, Vinh Duc 24 January 2024 (has links)
This thesis documents the development of a simulation strategy to model the behavior of geomembranes at large deformations using the explicit finite difference code FLAC3D. The geomembrane is represented by special shell elements and interfaces at both sides of the geomembrane duplicating the interaction with the overlying and underlying materials. Chapter 1 provides an introduction to geotextiles and geomembranes, and their use in geotechnical engineering. Special attention is paid to pull-out tests because of their importance to describe the behavior at large deformations. Chapter 2 describes the proposed ‘liner’ model concept to simulate the interaction of a geomembrane with the over- and underlying material. Furthermore, this chapter documents in detail the simulation of uniaxial pull-out tests for validation of the proposed ‘liner’ model concept and compares it with the FLAC3D built-in geogrid element. To clarify more clearly the potential failure (crack propagation and rupture process) of the geomembrane, the ‘liner’ model under biaxial loading was investigated in Chapter 3. Chapter 4 documents a detailed parameter study with a special focus on the stiffness and frictional behavior of the ‘liner’ element using a simplified waste dump. In chapter 5 a new constitutive model (“Femesalz”) is proposed to describe the visco-elasto-plastic behavior of crushed salt and waste rock salt, respectively. The “Femesalz” constitutive model together with the ‘liner’ model is applied to simulate the behavior of a rock salt waste dump (2.5-dimensional) to validate both, the new constitutive model “Femesalz” as well as the ‘liner’ model. Chapter 6 documents the use of the ‘liner’ element and the “Femesalz” constitutive model to simulate salt dump models in 2D and 3D on different terrain types (mountain, valley, plain) for a time of 100 years to generate large deformations. Chapter 7 contains the main conclusions and recommendations.:ABSTRACT AND STRUCTURE OF THESIS 2 ACKNOWLEDGMENTS 4 CONTENTS 5 LIST OF TABLES 7 LIST OF FIGURES 10 NOMENCLATURE 16 CHAPTER 1: INTRODUCTION AND STATE-OF-THE-ART 22 1.1 Geosynthetic for geoengineering projects (overview) 22 1.2 Pull-out tests (overview) 29 CHAPTER 2: “LINER” CONCEPT AND NUMERICAL SIMULATIONS OF UNIAXIAL PULL-OUT TESTS 39 2.1 Introduction 39 2.2 Numerical calculations 39 2.2.1 General considerations 39 2.2.2 Concept of the 'liner' element 40 2.2.3 'Geogrid' versus 'liner' element 41 2.2.4 Verification of ‘liner’ element 42 2.2.5 Conclusions 58 CHAPTER 3: BIAXIAL LOADING OF “LINER” MODEL 61 3.1 Introduction 61 3.2 Model set-up 61 3.3 Results of biaxial pull-out test simulation 63 3.4 Summary and Conclusions 71 CHAPTER 4: PARAMETER STUDY OF EMBEDDED GEOMEMBRANE 74 4.1 Introduction 74 4.2 Model set-up 74 4.3 Results 77 4.3.1 Influence of interface stiffness 80 4.3.2 Influence of interface friction 87 4.4 Conclusions 93 CHAPTER 5: CONSTITUTIVE MODEL FOR SALT DUMP 95 5.1 Introduction 95 5.1.1 Overview of constitutive models for rock salt 97 5.1.2 Overview of constitutive models for crushed salt 104 5.2 ‘Femesalz’ constitutive model for crushed salt 106 5.2.1 Introduction 106 5.2.2 Compaction test 111 5.2.3 Triaxial test and realistic waste dump simulation 114 5.2.4 Numerical salt dump simulations 115 5.3 Summary 122 CHAPTER 6: SIMULATIONS CONSIDERING TOPOGRAPHY OF UNDERLYING MATERIAL 123 6.1 Introduction 123 6.2 Model set-up 123 6.3 Model parameters and calculation sequence 131 6.4 Calculation results 132 6.5 Discussion of results and conclusions 139 CHAPTER 7: CONCLUSIONS 141 REFERENCE 143
120

Etude du comportement mécanique à l’arrachement de fils multi-filamentaires enrobés dans une matrice cimentaire et influence de l’imprégnation / Study of the mechanical pull-out behaviour of multi-filament yarns embedded in a cementitious matrix and influence of the impregnation

Aljewifi, Hana 12 December 2011 (has links)
Cette recherche porte sur les fils multifilamentaires de verre utilisés pour renforcer les matériaux à base de ciment. Elle est focalisée sur les interactions mécaniques de ce type de fils, constitués d'un assemblage de milliers de filaments micrométriques, avec un micro-béton et sur le rôle spécifique de l'imprégnation du fil par cette matrice cimentaire. Trois pré-conditionnements des fils ont été employés lors de la fabrication des éprouvettes afin de moduler les conditions d'imprégnation par la matrice cimentaire. L'imprégnation de 5 fils multi-filamentaires par la matrice cimentaire a été caractérisée et les paramètres d'imprégnation ont été définis en s'appuyant sur des observations MEB, ainsi que des essais de porosimétrie au mercure et des essais spécifiques d'écoulement le long du fil enrobé. Des essais classiques d'arrachement de type pull-out ont été utilisés pour la caractérisation mécanique. L'analyse des liens entre les propriétés mécaniques et les paramètres d'imprégnation ont permis de mieux comprendre les micro-mécanismes d'interaction filaments / matrice cimentaire et d'expliquer le comportement macroscopique à l'arrachement. / This research deals with multi-filaments glass yarns used as reinforcement of cement based materials. It focuses on the mechanical interactions of these yarns, made of thousands of micrometric filaments, with a micro-concrete and on the specific part of the impregnation of the yarn by the cementitious matrix. Modulated impregnation conditions of the yarns were obtained by using three different manufacturing processes for the samples preparation. The impregnation of 5 multi-filament yarns by the cementitious matrix has been characterized and physical parameters of impregnation were determined using SEM investigations, mercury intrusion porosity measurements and specific tests of flow all along the embedded yarn. Classical pull-out tests have been used for the mechanical characterisation. The study of the links between the mechanical properties and the physical parameters of impregnation allowed accessing a better understanding of the filaments / cementitious matrix interaction micro-mechanisms, and explaining the macroscopic pull-out behaviour.