Estudio de 2 edificaciones aporticadas considerando los efectos de la interacción tabique pórtico mediante el método del puntal equivalente / Study of 2 buildings considering the frame-masonry interaction by the equivalent strut method

Anaya Saldaña, Christian Alejandro, Asencio Huamanchay, Medali Del Carmen 26 August 2021 (has links)
La tabiquería a pesar de estar aislada aporta cierta rigidez lateral a los pórticos como se demostró en el estudio de (Zhou, Kou, Peng, & Cui, 2018), por lo cual, se debe realizar en algunos casos un análisis considerando la interacción tabique pórtico En la primera parte de la tesis se evaluó que características de un pórtico son las más influyentes en el ancho efectivo (Wb) del puntal equivalente a partir de un análisis con el método de elementos finitos, donde se encontró que la longitud diagonal del pórtico es la variable más influyente. Luego en la segunda parte se realizó un análisis sísmico de 2 edificaciones que fueron predimensionadas con la deriva máxima y 50% de la deriva máxima de la norma E0.30. Estos 4 modelos se analizaron con tabiquería y sin tabiquería, con el método modal espectral y tiempo historia. Las principales conclusiones fueron que realizar un análisis considerando la ITP puede cambiar el comportamiento modal de la edificación, la cortante basal aumentó hasta en un 19.5% en la estructura rígida y 17% en la flexible, los desplazamientos laterales se redujeron en máximo el 53% en la estructura flexible y 16% en la rígida, y que el periodo disminuyó hasta un 25%. Se concluyó que una edificación más flexible amplifica las diferencias entre el modelo con ITP y sin ITP. Por último, se confirmó que el análisis considerando la ITP saca a la luz irregularidades por torsión y/o piso blando que no se encuentra en un análisis convencional. / The masonry wall, despite being isolated, provides a certain lateral stiffness to the frames, as demonstrated in the study by (Zhou, Kou, Peng, & Cui, 2018), therefore, in some cases an analysis must be carried out considering the masonry walls. In the first part of the thesis, it was evaluated which characteristics of a frame are the most influential in the effective width (Wb) of the equivalent prop from an analysis with the finite element method, where it was found that the diagonal length of the frame is the most influential variable. Then, in the second part, a seismic analysis of 2 buildings was performed that were pre-dimensioned with the maximum drift and 50% of the maximum drift of the E0.30 standard. These 4 models were analyzed with masonry and without masonry, with the spectral modal method and time history. The main conclusions were that carrying out an analysis considering the ITP can change the modal behavior of the building, the basal shear increased by up to 19.5% in the rigid structure and 17% in the flexible one, lateral displacements were reduced by a maximum of 53% in the flexible structure and 16% in the rigid structure, and that the period decreased to 25%. It was concluded that a more flexible building amplifies the differences between the model with ITP and without ITP. Finally, it was confirmed that in the analysis considering the ITP there are irregularities due to torsion and / or soft story. / Tesis