• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Numerical Study of Directionality of Ion Ejection In Axially Symmetric Ion Traps

Naveen Reddy, D S Srinivas 08 1900 (has links) (PDF)
In the normal operation of quadrupole ion trap mass spectrometers, the trapped ions are ejected symmetrically through both the upper (detector) and lower(source) endcap electrodes during mass selective boundary ejection experiment. This reduces the sensitivity of the instrument by almost 50%. In this preliminary study, we altered the geometry parameters of the quadrupole ion traps to introduce asymmetry. The asymmetry displaced the ion cloud towards the detector endcap which resulted in a preferential ejection through this endcap, thus imparting directionality to the ejected ions and hence to the sensitivity enhancement. Two symmetrical mass analyzers have been taken up for numerical study. They include the Paul trap(QIT) and the cylindricaliontrap(CIT). Asymmetry to these geometries is introduced in two ways, one by varying the upper endcap hole radius alone and in other by stretching the trap along the upper endcap only. The escape velocity plots and mass selective boundary ejection simulations are used to demonstrate the directionality of ion ejection for these geometries. The simulations revealed a significant increase in the number of ions getting ejected in the direction of asymmetry.
2

Numerical Studies of Axially Symmetric Ion Trap Mass Analysers

Kotana, Appala Naidu January 2017 (has links) (PDF)
In this thesis we have focussed on two types of axially symmetric ion trap mass analysers viz., the quadrupole ion trap mass analyser and the toroidal ion trap mass analyser. We have undertaken three numerical studies in this thesis, one study is on the quadrupole ion trap mass analysers and two studies are on the toroidal ion trap mass analysers. The first study is related to improvement of the sensitivity of quadrupole ion trap mass analysers operated in the resonance ejection mode. In the second study we have discussed methods to determine the multipole coefficients in the toroidal ion trap mass analysers. The third study investigates the stability of ions in the toroidal ion trap mass analysers. The first study presents a technique to cause unidirectional ion ejection in a quadrupole ion trap mass spectrometer operated in the resonance ejection mode. In this technique a modified auxiliary dipolar excitation signal is applied to the endcap electrodes. This modified signal is a linear combination of two signals. The first signal is the nominal dipolar excitation signal which is applied across the endcap electrodes and the second signal is the second harmonic of the first signal, the amplitude of the second harmonic being larger than that of the fundamental. We have investigated the effect of the following parameters on achieving unidirectional ion ejection: primary signal amplitude, ratio of amplitude of second harmonic to that of primary signal amplitude, different operating points, different scan rates, different mass to charge ratios and different damping constants. In all these simulations unidirectional ejection of destabilized ions has been successfully achieved. The second study presents methods to determine multipole coefficients for describing the potential in toroidal ion trap mass analysers. Three different methods have been presented to compute the toroidal multipole coefficients. The first method uses a least square fit and is useful when we have ability to compute potential at a set of points in the trapping region. In the second method we use the Discrete Fourier Transform of potentials on a circle in the trapping region. The third method uses surface charge distribution obtained from the Boundary Element Method to compute these coefficients. Using these multipole coefficients we have presented (1) equations of ion motion in toroidal ion traps (2) the Mathieu parameters in terms of multipole coefficients and (3) the secular frequency of ion motion in these traps. It has been shown that the secular frequency obtained from our method has a good match with that obtained from numerical trajectory simulation. The third study presents stability of ions in practical toroidal ion trap mass analysers. Here we have taken up for investigation four geometries with apertures and truncation of electrodes. The stability is obtained in UDC-VRF plane and later this is converted into A-Q plane on the Mathieu stability plot. Though the plots in terms of Mathieu parameters for these structures are qualitatively similar to the corresponding plot of linear ion trap mass analysers, there is a significant difference. The stability plots of these have regions of nonlinear resonances where ion motion is unstable. These resonances have been briefly investigated and it is proposed that they occur on account of hexapole and octopole contributions to the field in these toroidal ion traps.
3

Numerical Investigation of Segmented Electrode Designs for the Cylindrical Ion Trap and the Orbitrap Mass Analyzers

Sonalikar, Hrishikesh Shashikant January 2016 (has links) (PDF)
This thesis is a numerical study of fields within ion traps having segmented electrodes1. The focus is on two cylindrical ion trap structures, two Orbit rap structures and one planar structure which mimics the field of the Orbit rap. In all these geometries, the segments which comprise the electrodes are easily Machin able rings and plates. By applying suitable potential to the different segments, the fields within these geometries are made to mimic the fields in the respective ideal structures. This thesis is divided into 6 chapters. Chapter 1 presents introduction and background information relevant to this work. A brief description of the Quadrupole Ion Trap (QIT) and the Orbit rap is given. The role of numerical simulations in the design of an ion trap geometry is briefly outlined. The motivation of this thesis is presented. The chapter ends by describing the scope of the thesis. Chapter 2 presents a general description of computational methods used throughout this work. The Boundary Element Methods (BEM) is first described. Both 2D and 3D BEM are used in this work. The software for 3D BEM is newly developed and hence 3D BEM is described in more detail. A verification of 3D BEM is presented with a few examples. The Runge-Kutta method used to compute the trajectory of ion is presented. A brief overview of the Nelder-Mead method of function minimization is given. The computational techniques specifically used to obtain the results in Chapter 3, 4 and 5 are presented in the respective chapters. Chapter 3 presents segmented electrode geometries of the Cylindrical Ion Trap (CIT). In these geometries, the electrodes of the CIT are split into number of mini-electrodes and different voltages are applied to these segmented electrodes to achieve the desired field. Two geometries of the segmented electrode CIT will be investigated. In the first, we retain the flat end cap electrodes of the CIT but split the ring electrode into five mini-rings. In the second configuration, we split the ring electrode of the CIT into three mini-rings and 1The term ‘segmented electrode’ used in this thesis has the same connotation as the term ‘split-electrode’ used in Sonalikar and Mohanty (2013). also divide the end caps into two mini-discs. By applying different potentials to the mini-rings and mini-discs of these geometries we will show that the field within the trap can be optimized to desired values. Two different types of fields will be targeted. In the first, potentials are adjusted to obtain a linear electric field and, in the second, a controlled higher order even multipole field are obtained by adjusting the potential. It will be shown that the different potentials to the segmented electrodes can be derived from a single RF generator by connecting appropriate capacitor terminations to segmented electrodes. The field within the trap can be modified by changing the value of the external capacitors. Chapter 4 presents segmented electrode geometries which are possible alternatives for the Orbitrap. Two segmented-electrode structures, ORB1 and ORB2, to mimic the electric field of the Orbitrap, will be investigated. In the ORB1, the inner spindle-like electrode and the outer barrel-like electrode of the Orbitrap are replaced by rings and discs of fixed radii, respectively. In this structure two segmented end cap electrodes are added. In this geometry, different potentials are applied to the different electrodes keeping top-bottom symmetry intact. In the second geometry, ORB2, the inner and outer electrodes of the Orbitrap are replaced by an approximate step structure which follows the profile of the Orbitrap electrodes. For the purpose of comparing the performance of ORB1 and ORB2 with that of the Orbitrap, the following studies will be undertaken: (1) variation of electric potential, (2) computation of ion trajectories, (3) measurement of image currents. These studies will be carried out using both 2D and 3D Boundary Element Method (BEM), the 3D BEM is developed specifically for this study. It will be seen in these investigations that ORB1 and ORB2 have performance similar to that of the Orbitrap, with the performance of the ORB1 being seen to be marginally superior to that of the ORB2. It will be shown that with proper optimization, geometries containing far fewer electrodes can be used as mass analysers. A novel technique of optimization of the electric field is proposed with the objective of minimizing the dependence of axial frequency of ion motion on the initial position of an ion. The results on the optimization of 9 and 15 segmented-electrode trap having the same design as ORB1 show that it can provide accurate mass analysis. Chapter 5 presents a segmented electrode planar geometry named as PORB used to mimic the electric field of the Orbit rap. This geometry has two planes, each plane consisting of 30 concentric ring electrodes. Although the geometry of PORB does not have conventional inner and outer electrodes of the Orbit rap, it will be shown that by selecting appropriate geometry parameters and suitable potentials for the ring electrodes, this geometry can trap the ions into an orbital motion similar to that in the Orbit rap. The performance of the planar geometry is studied by comparing the variation of potential, ion trajectories and image current in this geometry with that in the Orbit rap. The optimization of applied potentials is performed to correct the errors in the electric field so that the variation of axial frequency of ions with their initial position is minimized. Chapter 6 presents the summary and a few concluding remarks
4

Escape Of High Mass Ions Due To Initial Thermal Energy And Its Implications For RF Trap Design

Subramanyan, E K Ganapathy 09 1900 (has links) (PDF)
This thesis investigates the loss of high mass ions due to the initial thermal energy in ion trap mass analyzers. It provides an analytical expression for estimating the percentage loss of ions of a given mass at a particular temperature, in a trap operating with a set of conditions. The investigations have been carried out on quadrupole and cylindrical ion trap geometries. The three-dimensional Maxwellian velocity distribution function has been assumed to derive an expression for the percentage of ions lost. Adopting an approximation based on the observed escape velocity profiles of ions, an expression for the percentage loss of ions of a given mass has been derived as a function of the temperature for an ensemble of ions, its mass and its escape velocity. An analytical expression for the escape velocity has also been developed. It is seen that the escape velocity is a function of the trapping field, drive frequency and ion mass. Because the trapping field is determined by trap design parameters and operating conditions, it has been possible to study the influence of these parameters on ion loss. The parameters investigated include ion temperature, magnitude of the initial potential applied to the ring electrode (which determines the low mass cut-off), trap size, dimensions of apertures in the endcap electrodes and RF drive frequency. The studies demonstrate that ion loss due to initial thermal energy increases with increase in mass and that ion escape occurs in the radial direction. Reduction in the loss of high mass ions is favoured by lower ion temperatures, increasing low mass cut-off, increasing trap size, and higher RF drive frequencies. The dimensions of the apertures in the endcap electrodes do not influence ion loss in the range of aperture sizes considered.

Page generated in 0.2971 seconds