• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Mesures réparties par réflectométrie fréquentielle sur fibre optique / OFDR for optical fiber detectors

Boldyreva, Ekaterina 20 October 2016 (has links)
Les travaux de la présente thèse concernent l’étude théorique et la réalisation d’un Capteur réparti à Fibres Optiques fondé sur la réflectométrie fréquentielle et la rétrodiffusion de Rayleigh. La genèse de cette méthode remonte aux années 80 pour les mesures distribuées. Il y a un peu plus d’une dizaine d’années qu’elle a été mise en œuvre secrètement pour les meures réparties (continument sensibles) par la société américaine « Luna Innovations ». Cette approche permettant de réaliser des profils continus le long de la fibre des paramètres environnants (température et déformation principalement) offre une très bonne résolution spatiale ainsi qu’une résolution de mesure fine et présente donc un grand intérêt pour de nombreuses applications, venant ainsi en complément des techniques reposant sur la diffusion Raman ou Brillouin. L'aspect théorique de cette méthode dite OFDR Rayleigh a été analysé. Pour effectuer une mesure profilométrique il est nécessaire de déterminer simultanément deux informations : la distance physique allant de l’entrée de la fibre jusqu'au point où un paramètre physique à mesurer a été appliqué, et le paramètre physique proprement dit. Pour réaliser cette mesure un lien entre l'influence du paramètre d’influence et le changement d'indice du cœur de la fibre sous test doit être exploité. Il s’agit donc des sensibilités de mesure, mais aussi de l’influence de l’environnement sur le chemin optique parcouru, et donc sur la localisation précise des points de mesure. Ces différents aspects ont donc été analysés et rapportés dans le présent mémoire. Pour mettre en œuvre cette technique fréquentielle, et en particulier son traitement de signal, relativement complexe, deux méthodes différentes ont été proposées : la première dite « corrélationnelle » (mise en œuvre par « Luna Innovations » mais très peu documentée) et la méthode « tensorielle » proposée uniquement dans le cadre de la présente étude. Etant fondée sur les mesures répétitives des décalages spectraux induits par le paramètre physique à mesurer le long de la fibre, la méthode corrélationnelle est plus universelle, s’adressant à tous types de paramètres d’influence. Pourtant, elle s’avère moins précise du fait d'une erreur systématique dans le calcul des décalages spectraux. La méthode tensorielle, quant à elle, fournit un résultat plus précis, cependant elle n'est applicable que pour les mesures de déformations, puisque reposant sur l'effet élasto-optique dans le cœur de la fibre. Une procédure de traitement de signal a ensuite été élaborée pour les deux méthodes précitées, la corrélationnelle et la tensorielle. Les performances capacités de l'appareil dont nous disposons, Luna OBR 4600, ont également été montrées, tant en ce qui concerne les mesures de température que de déformations. Un banc expérimental mettant en œuvre cette méthode de mesure OFDR-Rayleigh a également été conçu est mis au point au laboratoire. Un logiciel de traitement des données a de fait été élaboré est réalisé. Ce programme a été testé à l'aide d'une simulation et grâce à l’utilisation des données brutes délivrées par l’appareil Luna OBR 4600. Plusieurs tests du programme de traitement des données brutes de cet instrument ont été réalisés. Les résultats de ces tests peuvent être considérés plutôt comme satisfaisants, étant globalement en bon accord avec les résultats fournis directement par l'instrument commercial OBR 4600. Au-delà, de nombreux exemples d'applications innovantes de la méthode Rayleigh OFDR ont été présentés et illustrés. Parmi ceux-ci, citons, le système de détection de fuites de sodium liquide pour la surveillance de fonctionnement des circuits de refroidissement des réacteurs de génération IV que nous avons élaboré, grâce à cette méthode Rayleigh OFDR, et un prototype industriel d'un tel système proposé. Enfin, l’analyse des points pouvant faire l’objet d’améliorations et/ou de marges de progrès a été menée, et est rapportée en fin de mémoire. / The present PhD thesis have been carried out at the Laboratoire de Mesures Optiques (Optical Measurement Laboratory) based at CEA Saclay Nuclear Research Center, France. It concerns theoretical analysis and experimental realizations of a “distributed Optical Fiber Sensor” based on Optical Frequency Domain Reflectometry using the Rayleigh backscattering phenomena. As the OFS community know, such technology has been developed by the US company Luna Innovations Inc., which keeps carefully secret any details of both the technology involved and the signal processing of such instruments, named OBR (Optical Backscattered Reflectometer). Advantageously, the present Rayleigh-OFDR method provides a very high spatial resolution (in comparison with other methods based on reflectometry, i.e. OTDR, DTS Raman, Brillouin BOTDR and BOTDA…) and so remains extremely sought for many applications, especially for Structural Health Monitoring. In the present PhD thesis the theoretical aspects of the Rayleigh OFDR method has been presented. As a reminder, in order to measure a physical parameter profile along the fiber, it is required to determine two subjects simultaneously: the distance at which the physical parameter is applied (i.e. the sensor address) to the fiber under test, and the amplitude of this parameter (i.e. “the measurement” itself). A relation between the influence of any environment parameter (temperature, strain, etc.) and the fiber core refractive index changes has to be used. These relations have been shown, as far as the hypothesis linked to the theoretical aspects. Two different methods for such measurement have been proposed: first of all the “correlation method” (used by Luna) and second “a tensor-based method”, fully innovative as developed during the present PhD thesis. The correlation method may be considered as more “universal” as based on the measurement of spectral shifts caused by the physical parameter to measure. But, in the same time, we consider it is less accurate, as a systematic error may somehow fail the spectral shift calculation algorithm. The tensor method do not suffer of such systematic error, but it remains only applicable to strain sensing, as based on the elasto-optic effect. Signal processing procedure has been elaborated and tested for both methods, and of course discussed in the manuscript. In the same time, performances of the existing Luna OBR 4600 reflectometer has been tested at Lab. and are reported for both temperature and strain measurements. An optical mock-up for Rayleigh OFDR method has also been developed. A software, dedicated to signal processing has been fully developed either. This program has been tested for simulated sensing signals and for raw data delivered by the Luna OBR 4600 reflectometer. Results of such tests could be considered as satisfactory, even some questions to be solved remains. Finally, some practical examples of Rayleigh OFDR industrial applications have been shown and detailed. Moreover, in such context of real applications on field, an innovative Rayleigh OFDR system devoted to liquid sodium leakage detection around secondary cooling circuitry of generation IV nuclear reactors has been developed and tested on a nuclear installation. An industrial prototype of such measurement system has been elaborated. Finally, way of progress are analyzed and discussed for future R&D activities.
2

Capteurs de corrosion à fibre optique pour la surveillance répartie d’ouvrages en béton armé / Distributed corrosion sensing in reinforced concrete structures by optical fiber sensing

Ali Alvarez, Shamyr Sadat 19 September 2016 (has links)
La corrosion des armatures de renforcement des structures en béton représente un enjeu socio-économique majeur. Sa détection et le suivi de son évolution constituent un défi pour la recherche appliquée. Les techniques standards non destructives de détection de corrosion mettent en œuvre des procédés indirects tels la mesure d’impédance, de potentiels, ou par ultrasons. Leurs capacités d’auscultation sont limitées dans l’espace (notamment en profondeur), leur coût reste élevé dans un contexte de maintenance périodique et elles conduisent à des paramètres d’interprétation complexe. Des progrès sont nécessaires dans la détection et l’analyse fiable de la progression des processus de corrosion. Dans ce travail, nous présentons une nouvelle méthode pour détecter la corrosion et le suivi de son évolution, basée sur l’observation directe des changements intervenant à l’interface fer-béton par Capteur à Fibre Optique (CFO). L'attaque par corrosion de la surface de l'armature dépend de plusieurs paramètres électrochimiques (température, pH, carbonatation, présence de chlorures, contamination biologique, etc.). Deux comportements mécaniques à l'interface fer-béton sont distingués. Dans le premier cas (carbonatation), le produit d'oxydation du métal reste à l'interface et augmente la pression interne, pouvant conduire à la fissuration de la couche de béton extérieure. Dans le second cas (piqures), les ions métalliques sont évacués hors de la structure avec comme conséquence une réduction de section des barres d'armature (affaiblissement du renforcement). Un CFO innovant est proposé dans le but de localiser et quantifier les deux types de corrosion précités. Le principe consiste à observer l’impact direct de la corrosion sur l’état de déformation d’une fibre optique préalablement précontrainte par construction. Deux procédés métrologiques sont étudiés : Bragg et réflectométrie fréquentielle (Optical Frequency-Domain Reflectometry - OFDR). Des tests de corrosion accélérée montrent la faisabilité du procédé. Une procédure de fabrication simplifiée et à coût optimisé est proposée pour la surveillance in situ et répartie des structures de génie civil, dans une perspective future de maintenance conditionnée. / Corrosion of reinforced bars (rebars) in concrete structures remains a major issue in civil engineering works, being its detection and evolution a challenge for the applied research. Usual non-destructive corrosion detection methods involve impedance, potential or ultra-sonic indirect measurements of complex interpretation. Besides, they are restricted to near-surface examinations and the maintenance cost is still high (scheduled maintenance). Many efforts remain to be done to survey the onset and progression of corrosion processes in a reliable way. In this work, we present a new methodology to detect the onset of corrosion and to monitor its evolution, based on the direct observation of rebar–concrete interface changes by the use of an Optical Fiber Sensor (OFS). The corrosion attack over rebar surface depends on several physical, chemical and electrochemical parameters (temperature, pH, presence of chlorides/CO2, biological contamination, etc.). Two types of mechanical behavior and described. In the first case (carbonation), metal oxidation products stay at the interface and increase internal pressure, potentially leading to a crack of the external concrete layer. In the second case (pitting), metal ions are evacuated out of the structure, leading to a reduction of the rebar section (structural weakness). An innovative sensor design is proposed with the purpose of localizing and quantifying the amount of both corrosion types. The basic principle consists in measuring the impact of corrosion over the state of strain of a prestressed optical fiber. Two metrological techniques are used: Fiber Bragg Grating (FBG) and Optical Frequency-Domain Reflectometry (OFDR). Accelerated corrosion tests were performed in electrolytic solutions for both kinds of corrosion types (pitting and carbonation) and provide a proof-of-concept for the technique. A low-cost, simplified manufacturing procedure is proposed with the aim to provide distributed and in situ Structural Health Monitoring (SHM), suitable for future Condition-Based Maintenance (CBM) of civil engineering concrete structures.

Page generated in 0.274 seconds