• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Conception, réalisation et mise en oeuvre d'un microsystème pour la micro spectroscopie par résonance magnétique nucléaire

Pasquet, Guillaume 10 July 2009 (has links) (PDF)
Ce travail de thèse porte sur la conception, la réalisation et l'évaluation expérimentale d' un microsystème d'analyse dont l'originalité repose sur l'intégration d'une micro antenne planaire de spectroscopie par résonance magnétique nucléaire (SRMN) sur un système micro fluidique à base d'un polymère, le Cyclique Oléfine Copolymère (COC). La détermination des caractéristiques géométriques optimales du microsystème afin d'optimiser le couplage électromagnétique entre la micro antenne de détection et l'échantillon est effectuée à l'aide d'un modèle de calcul numérique, ce qui permet l'optimisation du rapport signal sur bruit (RSB). La réalisation du microsystème avec des procédés de micro fabrication développés au laboratoire ont permis de valides son fonctionnement dans un spectromètre dont le champ magnétique statique atteint 11.74 Tesla (fréquence de Larmor du proton égale à 500MHz). Travailler dans un champ aussi intense permet d'améliorer la sensibilité de détection mais nécessite de porter une attention particulière à l'homogénéité du champ magnétique qui, dans notre cas, peut être dégradée en raison de l'introduction du microsystème dans le spectromètre. En effet, les distorsions du champ magnétique, dues aux différentes susceptibilités magnétiques des matériaux constituant la microsonde, ont un impact direct sur la résolution spectrale. C'est pourquoi, une modélisation 3D par éléments finis est proposée afin de prévoir l'influence du microsystème sur la forme des raies spectrales et donc d'en déduire la résolution spectrale pouvant être espérée. La comparaison des résultats expérimentaux et ceux issus des simulations permet de valider le modèle de calcul numérique. Il apparait cependant nécessaire d'inclure le phénomène d'amortissement radiatif afin de pouvoir rendre compte des résultats expérimentaux relatifs à la résolution spectrale effectivement observée.
2

Investigation of speech processing in frequency regions where absolute thresholds are normal for hearing-impaired listeners / Etude du traitement de la parole dans des régions fréquentielles au sein desquelles les seuils absolus sont normaux pour des auditeurs malentendants

Léger, Agnès 30 November 2012 (has links)
Une perte auditive neurosensorielle est généralement associée à uneréduction de l’intelligibilité de la parole, et ce tout particulièrement dans le bruit.Les contributions respectives d’une réduction de l'audibilité et de déficitssupraliminaires sont encore débattues.L'objectif principal de cette thèse était d'évaluer l'effet spécifique desdéficits supraliminaires sur l’intelligibilité de la parole. L'effet de l'audibilité étaitcontrôlé en mesurant l’intelligibilité de signaux de parole sans signification filtrésdans les régions basses et moyennes fréquences au sein desquelles la détection desons purs était normale chez des auditeurs malentendants présentant par ailleursune perte auditive en hautes fréquences. Dans ces régions fréquentielles oùl’audibilité est supposée normale, des déficits d'intelligibilité de la parole légers àsévères ont été observés dans le silence comme dans le bruit chez les auditeursmalentendants. Les déficits étaient similaires dans les bruits masquantstationnaires et fluctuants. Ces résultats démontrent l’influence des déficitsauditifs supraliminaires sur l’intelligibilité de la parole.Le second objectif de cette thèse était d'étudier l'origine de ces déficitssupraliminaires. Les résultats indiquent qu’une réduction de la sélectivitéfréquentielle cochléaire ne peut pas expliquer entièrement les déficitsd’intelligibilité de la parole des auditeurs malentendants. L'influence de lasensibilité à la structure temporelle fine reste incertaine / Speech intelligibility is reduced for listeners with sensorineural hearingloss, especially for speech in noise. The extent to which this reduction is due toreduced audibility or to supra-threshold deficits is still debated.The main goal of this PhD work was to investigate the specific influenceof supra-threshold deficits on speech intelligibility. The effect of audibility wascontrolled for by measuring speech intelligibility for hearing-impaired listenersusing nonsense speech signals filtered in low- and mid-frequency regions wherepure-tone sensitivity was normal. Hearing-impaired listeners with hearing loss inhigh-frequency regions showed mild to severe intelligibility deficits for speechboth in quiet and in noise in these frequency regions of normal audibility. Similardeficits were obtained for speech in steady and fluctuating masking noises. Thisprovides additional evidence that speech intelligibility may be strongly influencedby supra-threshold auditory deficits.The second aim of this PhD work was to investigate the origin of thesesupra-threshold deficits. Results showed that reduced frequency selectivity cannotentirely explain the speech intelligibility deficits of the hearing-impaired listeners.The influence of temporal fine structure sensitivity remained unclear
3

Conception, réalisation et mise en oeuvre d'un microsystème pour la micro spectroscopie par résonance magnétique nucléaire / Design, development and experimental evaluation of an analysis micro system for NMR

Pasquet, Guillaume 10 July 2009 (has links)
Ce travail de thèse porte sur la conception, la réalisation et l’évaluation expérimentale d’ un microsystème d’analyse dont l’originalité repose sur l’intégration d’une micro antenne planaire de spectroscopie par résonance magnétique nucléaire (SRMN) sur un système micro fluidique à base d’un polymère, le Cyclique Oléfine Copolymère (COC). La détermination des caractéristiques géométriques optimales du microsystème afin d’optimiser le couplage électromagnétique entre la micro antenne de détection et l’échantillon est effectuée à l’aide d’un modèle de calcul numérique, ce qui permet l’optimisation du rapport signal sur bruit (RSB). La réalisation du microsystème avec des procédés de micro fabrication développés au laboratoire ont permis de valides son fonctionnement dans un spectromètre dont le champ magnétique statique atteint 11.74 Tesla (fréquence de Larmor du proton égale à 500MHz). Travailler dans un champ aussi intense permet d’améliorer la sensibilité de détection mais nécessite de porter une attention particulière à l’homogénéité du champ magnétique qui, dans notre cas, peut être dégradée en raison de l’introduction du microsystème dans le spectromètre. En effet, les distorsions du champ magnétique, dues aux différentes susceptibilités magnétiques des matériaux constituant la microsonde, ont un impact direct sur la résolution spectrale. C’est pourquoi, une modélisation 3D par éléments finis est proposée afin de prévoir l’influence du microsystème sur la forme des raies spectrales et donc d’en déduire la résolution spectrale pouvant être espérée. La comparaison des résultats expérimentaux et ceux issus des simulations permet de valider le modèle de calcul numérique. Il apparait cependant nécessaire d’inclure le phénomène d’amortissement radiatif afin de pouvoir rendre compte des résultats expérimentaux relatifs à la résolution spectrale effectivement observée. / The work presented in this thesis involves the design, the development and the experimental evaluation of an analysis micro system. The originality of the work lies in the integration of a planar micro coil of spectroscopy by nuclear magnetic resonance (SNMR) on a micro fluidic system based on a polymer, cyclo olefin copolymer (COC). The determination of the optimum geometric characteristics of the micro system to improve electromagnetic coupling between the detection micro coil and the sample is performed with the aid of a numerical model that ensures the optimization of the signal to noise ratio (SNR). Using micro fabrication techniques developed in the laboratory, the micro system was developed and its behaviour was validated in spectrometer producing a static magnetic field off 11.74 Tesla (Larmor frequency of the proton equal to 500MHz). Working in such an intense field results in improved sensitivity of detection but requires paying close attention to the homogeneity of magnetic field. In this case the homogeneity can be degraded due to the introduction of the micro system in the spectrometer. Indeed, the distortions of the magnetic field, due to the different magnetic susceptibilities of the materials constituting the microprobe, have a direct impact on the spectral resolution. As such, 3D modelling by finite elements is proposed to predict the influence of the micro system on the shape of the spectral lines and to determine the best expected spectral resolution. The comparison of the experimental results to those obtained from simulation allows the validation of the numerical model. However, it appears necessary to include the effect of the radiation damping in the model to be able to justify the experimental results relative to the spectral resolution that was observed.

Page generated in 0.112 seconds