• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Retração de caninos superiores com dois tipos de elásticos em cadeia

Giollo, Luciano Dias January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:07Z (GMT). No. of bitstreams: 2 000400719-0.pdf: 3832868 bytes, checksum: 7f7e5e2d5a4148bbc3e382e8c43c4bfc (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the speed of space closure in canine retraction submitted to two distinct types of elastomeric chains (Memory chain and Standard chain) and to determine: mean quantity of movement of upper canine retraction and the loss of anchorage involved. The sample consisted of 15 patients with Angle 1st division Class II malocclusion, with a mean age of 17, 5 years of 4 boys and 11 girls. All of them were submitted to first premolar extractions. Upper canine retraction was achieved with Standard elastomeric chains in the upper right quadrant and with Memory elastomeric chains in the upper left quadrant providing a starting force of 150 g. Canine retraction was assessed in a three week reactivation protocol, until canine retraction was completed or up to a maximum of 3 reactivations. At each recall, stone model casts were taken. The evaluation of the mean amount of space closure was accomplished in 4 different places (3 between canine-premolar and 1 between caninemolar) and anchorage loss measured between first permanent molar and medial point of third palatal rugae in stone model casts. Results showed a statistical difference towards Memory chain, at one measure point and between the first and second activations. Anchorage loss occurred in both specified retraction methods, however there was not significant difference between them. / O objetivo deste estudo foi avaliar o fechamento dos espaços na retração dos caninos permanentes superiores com dois tipos de elástico em cadeia distintos (elásticos em cadeia “Memory” e “Convencional”) determinando: a diferença média do movimento dentário e a perda de ancoragem dos primeiros molares permanentes superiores. A amostra constituiu-se de 15 pacientes portadores de maloclusão de Classe II divisão 1 de Angle, com média de idade de 17anos e 5 meses, sendo 4 do gênero masculino e 11 do feminino, e todos foram submetidos à extração de dois primeiros pré-molares superiores. A retração dos caninos superiores foi realizada com elástico em cadeia “Convencional”, na hemiarcada direita, e com elástico em cadeia tipo “Memory”, na esquerda, com força de 150 g. A distalização dos caninos foi avaliada a cada 3 semanas até esta ter sido completada ou num período máximo de 3 reavaliações. Em cada uma destas consultas, foi obtido modelo de gesso a partir de moldagens com alginato. A avaliação da quantidade média do fechamento dos espaços a cada 3 semanas foi feita em 4 locais diferentes (3 entre canino e pré-molar e 1 entre canino e molar) e a perda de ancoragem medida entre o primeiro molar permanente e o ponto mais medial da terceira ruga palatina nos modelos de gesso. Os resultados demonstraram maior movimentação com elásticos “Memory”, em uma das medidas de fechamento de espaços. Além disso, essa tendência limitou-se às três primeiras semanas de tratamento, perdendo a validade ao longo do período de retração de caninos superiores permanentes. Ocorreu perda de ancoragem para ambos os elásticos, no entanto, sem diferença estatística entre eles.
2

Retração de caninos superiores com molas fechadas de níquel-titânio e elásticos em cadeia

Pinto, Paulo Rogério de Oliveira January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:13Z (GMT). No. of bitstreams: 2 000386789-0.pdf: 11944950 bytes, checksum: 1e6a2354c67959fe7fd27a0c27bd0e49 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the speed of space closure in canine retraction submitted to two distinct methods (elastomeric chains and niquel-titanium closed coil springs) and to determine: mean speed, effect of sex and extrabucal appliance in dental movement mean speed occurred in each system. The sample consisted of 15 patients with Angle 1st division Class II malocclusion, with a mean age of 16,3 years ±5,6, being 8 boys and 7 girls, from these, 5 used extrabucal appliance and 10 were submitted to first premolar extractions. Upper canine retraction was achieved with powerchain elastics in the upper right quadrant and with niquel-titanium coil springs in the upper left quadrant providing a starting force of 150 g. Canine retraction was evaluated until canine retraction was completed or up to a maximum of 5 visits. At each recall, stone models were taken. The evaluation of space closure mean speed was accomplished in 4 different places (3 between canine-premolar and 1 between caninemolar) and anchorage loss measured between first permanent molar and medial point of third palatal rugae in stone models. Results showed greater canine retraction speed employing elastomeric chains, and there was not difference between male and female patients and between patients that used extrabucal appliance and submitted to extractions. Anchorage loss occurred in two retraction methods, however there was not significant difference between two systems to male and female patients. The comparison between patients that used extrabucal appliance and submitted to extractions showed that the anchorage loss was greater in extraction group with elastomeric chain. / O objetivo deste estudo foi avaliar o fechamento dos espaços na retração dos caninos permanentes superiores com dois métodos distintos (elásticos em cadeia e molas fechadas de níquel-titânio) determinando: a velocidade média do movimento dentário; a perda de ancoragem dos primeiros molares permanentes superiores; a influência do sexo e das extrações de pré-molares na velocidade média de movimento ocorrida em cada sistema. A amostra constituiu-se de 15 pacientes portadores de maloclusão de Classe II divisão 1 de Angle, com média de idade de 16,3 anos +5,6 anos, sendo 8 do sexo masculino e 7 do feminino, onde 5 utilizaram aparelho extrabucal previamente e 10 foram submetidos a extração de primeiros pré-molares superiores. A retração dos caninos superiores foi realizada com elásticos em cadeia, na hemiarcada direita, e com molas de níquel-titânio, na esquerda, com força de 150 g. A distalização dos caninos foi avaliada até esta ter sido completada ou num período máximo de 5 reavaliações. Em cada uma destas consultas, foi obtido modelo de gesso a partir de moldagens com alginato.A avaliação da velocidade média mensal do fechamento dos espaços foi feita em 4 locais diferentes (3 entre canino e pré-molar e 1 entre canino e molar) e a perda de ancoragem medida entre o primeiro molar permanente e o ponto mais medial da terceira ruga palatina nos modelos de gesso. Os resultados demonstraram maior velocidade na retração dos caninos com o emprego dos elásticos em cadeia, não havendo diferença entre indivíduos do sexo masculino e feminino e entre os pacientes que utilizaram aparelho extra-bucal e os submetidos a extrações. Ocorreu perda de ancoragem com o uso dos dois métodos de retração, porém não houve diferença significativa entre os dois sistemas para pacientes do sexo masculino e feminino. Já em relação à comparação entre pacientes que utilizaram AEB e os que tiveram os pré-molares extraídos, estes últimos apresentaram maior perda de ancoragem com o uso dos elásticos em cadeia.
3

Retração de caninos superiores com bráquetes autoligados e convencionais

Mezomo, Maurício Barbieri January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:17Z (GMT). No. of bitstreams: 2 000414875-0.pdf: 8343665 bytes, checksum: eca6520ad66453c0339e6ec79200478b (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this split mouth randomized clinical trial was to evaluate and compare the space closure during the retraction of upper permanent canine with self-ligating "SmartClip" and conventional "Gemini" brackets. Sample complied 13 patients with Class I biprotrusion or Class II 1st division malocclusion, with an average age of 18 years and 4 months, 3 male and 10 female. All were submitted to the therapeutic extraction of two first premolars. The retraction of the upper canines was performed with elastomeric chain with 150g of force. The evaluations were performed at four times (T1 – initial, T2 – 4 weeks, T3 – 8 weeks, T4 – 12 weeks) in stone model casts. The amount of movement and the rotation of the canines as well anchorage loss of upper first molars were evaluated. The space closure measurement was made between canine and second premolar and rotation was assessed by an angle formed by the intersection of the line drawn through the canine’s contact points and the line of the palatal suture. The anchorage loss was measured by a guide adapted at the palatal rugae in stone casts at initial and end.The data obtained were subjected to Student t test considering level of significance of 5%. The results shown that selfligating bracket had an average of 0. 92 mm (+/- 0. 29) of rate movement and 8. 46o (+/- 4. 68) of the rotation of the upper canines and 0. 65 mm (+/- 0. 24) of anchorage loss; the conventional bracket had an average of 0. 84 mm (+/- 0. 22) of rate movement and 11. 77o (+/- 3. 26) of the rotation of and the upper canines and 0. 57 mm (+/- 0. 24) of anchorage loss. There was no difference (p=0. 250) in the rate of movement of the canines between the two types de brackets. The rotational control of the canines was better promoted by self-ligating bracket (p=0. 005). There was anchorage loss for both groups, with no statistical difference between them (p=0. 157). / O objetivo deste ensaio clínico randomizado tipo boca dividida foi avaliar e comparar o fechamento dos espaços durante a retração dos caninos permanentes superiores com os bráquetes autoligado “SmartClip” e convencional “Gemini”. A amostra foi constituída de 13 pacientes portadores de maloclusão de Classe I com biprotrusão ou Classe II 1ª divisão de Angle, com média de idade de 18 anos e 4 meses, sendo 3 do gênero masculino e 10 do feminino. Todos os indivíduos foram submetidos à extração terapêutica dos primeiros pré-molares superiores. A retração dos caninos foi realizada através de cadeia elastomérica com força de 150g. As avaliações foram realizadas nos tempos (T1 – inicial, T2 – 4 semanas, T3 – 8 semanas, T4 – 12 semanas) através de modelos de gesso. Foram analisadas a taxa da movimentação e rotação dos caninos bem como a perda de ancoragem dos primeiros molares permanentes superiores. A mensuração do fechamento dos espaços foi realizada entre o canino e o segundo pré-molar e a rotação através do ângulo formado pela intersecção da linha que passava pelos pontos de contato dos caninos com a linha da rafe palatina mediana. A perda de ancoragem foi medida por um guia adaptado às rugas palatinas nos modelos de gesso inicial e final. Os dados obtidos foram submetidos a análise estatística através do teste t-Student considerando o nível de significância de 5%. Os resultados demonstraram que o bráquete autoligado apresentou taxa média de movimentação mensal de 0,92mm (+/- 0,29) e rotação de 8,46o (+/- 4,68) dos caninos superiores e a perda de ancoragem de 0,65mm (+/- 0,24); o bráquete convencional apresentou taxa média de movimentação mensal de 0,84mm (+/- 0,22) e rotação de 11,77o (+/- 3,26) dos caninos superiores e a perda de ancoragem de 0,57mm (+/- 0,24).Não houve diferença significativa (p=0,250) entre a taxa de movimentação dentária dos caninos entre os dois tipos de bráquetes. O controle de rotação dos caninos foi melhor promovido pelo bráquete autoligado (p=0,005). Ocorreu perda de ancoragem para ambos os grupos, sem diferença estatística entre eles (p=0,157).
4

Avaliação in vitro das forças geradas por cadeias elásticas e molas fechadas de NiTi

Porto, Janise Bizarro Pereira January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:11Z (GMT). No. of bitstreams: 2 000424760-0.pdf: 9386318 bytes, checksum: 55f075ab7be050ba8f670a49a394022b (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this in vitro study was to access the strength produced by the nickel titanium closed-coil springs from three different comercial brands (American Orthodontics®, TP orthodontics® and Morelli®) as well as elastomeric chains from two brands available in the market (American Orthodontics® – Memory Chain e Morelli® – conventional) when submitted to 50% and 100% distensions from initial length and then check their strength behavior within time. Both strength values were measured within five intervals of initial 3, 4, 6 and 9 weeks. The sample included 240 nickel titanium closed-coil springs and 80 of the elastomeric chains segments were divided into 16 groups according to the type of material, either nickel titanium closed-coil spring or elastomeric chains, commercial brand and distension submitted. Each group had 20 samples, distended in 50% or 100% from initial length and were kept distended on steel plates immersed in artificial salive solution at the steady temperature of 37ºC. The strength developed by the samples was assessed through a tension test carried out by a mechanic essay machine Emic DL2000® at a 0,5mm/minute speed. The results were submitted to statistical ANOVA and Tukey tests. The NiTi closed coil springs and elastomeric chains distended 50% of the initial length showed initial force between 126. 3 and 267. 5 gf and between 192. 6 and 267. 8 gf, respectively; in the end of nine weeks the average strength was between 131. 7 and 263 gf for the NiTi closed coil springs and between 123. 7 and 141. 3 gf for elastomeric chains. Distension of 100% of initial length of the average initial force produced by the NiTi closed coil springs was between 214. 3 and 451. 5 gf and elastomeric chains between 306. 6 and 380. 5 gf, after nine weeks of average strength remained between 196. 7 and 397. 3 gf for the NiTi closed coil springs and between 179. 4 and 189. 3 gf for elastomeric chains. Such results indicated. / O objetivo do presente estudo foi avaliar, in vitro, as forças produzidas pelas molas fechadas de níquel-titânio de três marcas comerciais diferentes (American Orthodontics®, TP orthodontics® e Morelli®) e cadeias elásticas de duas marcas disponíveis comercialmente (American Orthodontics® – Memory Chain e Morelli® – convencional) quando submetidas a distensões de 50% e 100% do comprimento inicial e verificar o comportamento destas forças ao longo do tempo. As forças foram aferidas em cinco intervalos de tempo: inicial, 3, 4, 6 e 9 semanas. Para tanto 240 molas fechadas de níquel-titânio e 80 segmentos de cadeias elásticas foram divididos em 16 grupos de acordo com o tipo de material, mola fechada de níqueltitânio ou cadeia elástica, marca comercial e distensão submetida. Para cada grupo 20 amostras foram distendidas em 50% ou 100% do comprimento inicial e assim mantidas em placas de aço e imersas em solução de saliva artificial à temperatura constante de 37ºC. As forças desenvolvidas pelas amostras foram aferidas através de um teste de tração realizado por uma máquina de ensaio mecânico Emic DL2000® à velocidade de 0,5mm/minuto. Os resultados foram submetidos a testes estatísticos ANOVA e Tukey. As molas fechadas de NiTi e cadeias elásticas distendidas 50% do comprimento inicial apresentaram força inicial entre 126,3 e 267,5 gf e entre 192,6 e 267,8 gf, respectivamente; ao final de 9 semanas a média de força ficou entre 131,7 e 263 gf para as molas fechadas e entre 123,7 e 141,3 gf para as cadeias elásticas. Na distensão de 100% do comprimento inicial a média de força inicial apresentada pelas molas fechadas de NiTi ficou entre 214,3 e 451,5 gf e para as cadeias elásticas entre 306,6 e 380,5 gf; após 9 semanas a média de força permaneceu entre 196,7 e 397,3 gf para as molas fechadas de NiTi e entre 179,4 e 189,3 gf para as cadeias elásticas. Os resultados indicaram que tanto as molas fechadas de níquel-titânio como as cadeias elásticas desenvolveram forças iniciais maiores e maior taxa de degradação da força ao longo do tempo quando distendidas 100% do comprimento inicial quando comparadas a distensão de 50%. As molas fechadas de NiTi apresentaram menores percentuais de degradação da força do que as cadeias elásticas nas duas distensões avaliadas.

Page generated in 0.0296 seconds