• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do conforto térmico de uma biblioteca universitária pela ASHRAE Standard 55 e EN 15251 / Analysis of the thermal ambience of the universitarian library by ASHRAE Standard 55 and EN 15251

Valadão, Júlia Barros 29 September 2011 (has links)
Made available in DSpace on 2015-03-26T13:28:06Z (GMT). No. of bitstreams: 1 texto completo.pdf: 4953266 bytes, checksum: 255416500dde28dd19ebaa9b6dbc0ab8 (MD5) Previous issue date: 2011-09-29 / Since 2001 energy crisis, Brazil searches to rationalize it's energetic usage, one of the objects used to reach this goal is the creation of minimum level of energetic efficiency. This process, first initiated in 2009 with electric appliances, has reached a new status when included buildings in the Programa Brasileiro de Etiquetagem (Brazilian Tagging Program), as can be verified in Regulamento Técnico da Qualidade do Nível de Eficiência Energética de Edifício Comerciais de Serviços Públicos [Technical Norm of Energetic Efficiency Level in Commercial, Services and Public Buildings] (RTQ-C). Although RTQ-C allows the measurement of efficiency levels in buildings, it does not guarantee the higrothermal comfort levels, because it remains silent about this subject, thus maintaining the national tradition of inexistent norms in this area. Begining with the exposed facts, this study objectives were to compare higrothermal comfort levels between ANSI/ASHRAE Standard 55, ISO 7730 and 15251 norms, through a case study using the Biblioteca Central of Universidade Federal de Viçosa-MG, pointing out the differences in those norms. The research was performed in four different stages: in loco measurements of the building in three separate seasons of the year, in order to collect higrothermal conditions in summer, autumn and winter; the pre-modeling tests, which verified the possibility of simplification of the library modeling in order to keep, while in simulation, higrothermal conditions similar to those in the real building; the validation of the model through simulations, which had alterations in parameters of the reference archetype, comparing the exiting data to the ones measured in the place in a way to approach environmental manifestation found in the real building; at last it was defined a level scale of thermal comfort, that made possible the comparison between the different norms. The main results obtained, in this research: a) not occur on the premises considered, the environments in conditions that meet the human needs of comfort and hygrothermal conservation bibliographic b) realization of the possibility of use in Brazil, comfort scale for assessment of proposed buildings, existing in EN 15251, therefore, to be more restrictive would allow the improvement of the quality of buildings in this regard. / Desde a crise de energia de 2001, o Brasil busca racionalizar o seu consumo energético, utilizando, como um dos instrumentos para atingir essa finalidade, a criação de níveis mínimos de eficiência energética. Esse processo, iniciado com os eletrodomésticos, galgou novo patamar ao incluir as edificações no Programa Brasileiro de Etiquetagem, em 2009, conforme se verifica pelo Regulamento Técnico da Qualidade do Nível de Eficiência Energética de Edifícios Comerciais de Serviços e Públicos (RTQ-C). Embora o RTQ-C permita que se mensure o nível de eficiência das edificações, não garante os índices de conforto higrotérmico, já que silente nesse aspecto, mantendo-se, assim, a tradição nacional de inexistência de regulamentação nessa matéria. Partindo desses fatos, o presente estudo objetivou comparar os níveis de conforto higrotérmico entre as normas ANSI/ASHRAE Standard 55 e EN 15251, tendo como estudo de caso a Biblioteca Central da Universidade Federal de Viçosa-MG, apontando as diferenças entre os seus resultados. A pesquisa foi realizada em quatro etapas principais: a realização de medições in loco da edificação em três épocas do ano, para coleta das condições higrotérmicas de verão, outono e inverno; a realização dos testes pré-modelagem, em que se verificou a possibilidade de simplificação da modelagem da biblioteca para manter, na simulação, condições higrotérmicas semelhantes ao edifício real; a validação do modelo mediante simulações em que se alteraram parâmetros no arquétipo referência, comparando-se os dados de saída aos medidos no local, de forma a se aproximar das manifestações ambientais encontradas no edifício real; e, finalmente, definição de uma escala de níveis de conforto térmico, o que viabilizou a comparação entre as normas. Como principais resultados obtidos, tem-se: a) não ocorrência, no edifício analisado, de ambientes em condições que satisfazem as necessidades humanas de conforto higrotérmico e as de conservação do acervo bibliográfico; b) constatação da possibilidade de uso, no Brasil, da escala de conforto proposta para avaliação das edificações, existente na EN 15251, pois, por ser mais restritiva, viabilizaria a melhoria da qualidade das construções neste aspecto.
2

Análise do desempenho termoenergético de escolas públicas segundo aplicação do RTQ-C para a envoltória / Analysis of the thermal energetical performance of public schools according to application of the RTQ-C for the building envelope

Paulse, Pablo de Caldas 31 March 2016 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2016-10-21T11:32:06Z No. of bitstreams: 2 Dissertação - Pablo de Caldas Paulse - 2016.pdf: 10117343 bytes, checksum: e6a611950376f02b571e71c147ba8c8b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2016-11-08T18:41:53Z (GMT) No. of bitstreams: 2 Dissertação - Pablo de Caldas Paulse - 2016.pdf: 10117343 bytes, checksum: e6a611950376f02b571e71c147ba8c8b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-11-08T18:41:53Z (GMT). No. of bitstreams: 2 Dissertação - Pablo de Caldas Paulse - 2016.pdf: 10117343 bytes, checksum: e6a611950376f02b571e71c147ba8c8b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-03-31 / The search for buildings with better energy performance has been the subject of several studies, due to the energy crisis that Brazil and the world are facing and the need for a more sustainable solution for buildings. In this context, this thesis presented the analysis of the envelope (vertical walls and roof) of a school building whose purpose is to optimize its thermoenergetic performance and the achievement of higher levels of indoor thermal comfort for its users. The object of study was a standard building for classrooms of public schools in the city of Goiania–GO, whose dimensions and spatial characteristics have not been changed significantly; the analysis focusing only the building components that characterize its envelope. The thermoenergetic assessment of the proposed building was based on the Quality of Technical Regulation Methodology for Energy Efficiency of Commercial Buildings, Services and Public - RTQ-C of the Brazilian Labeling Program in Buildings (PBE Edifica), which establishes parameters for the classification of energy performance through the National Energy Conservation Label (ENCE). For this purpose, analysis were carried out of the building envelope according to the prescriptive method, based on calculations and parameters pre-set by the Regulation, and on computer simulations carried out by creating scenarios using materials and solutions recommended by the Regulation and performance of technical standards buildings (NBR 15575: 2013) and thermal performance in buildings (NBR 15220: 2005), both referenced by RTQ-C. For the simulations was used the DesignBuilder software. Simulated models were evaluated according to two criteria: the indoor air temperature and the thermal comfort of users defined by the PMV index. The results were applied to the RTQ-C methodology and demonstrate that the changes in the type of masonry and in the roof of the original model, added to the incorporation of shading elements in the openings, can provide a change in the ENCE final classification, which moves up from a medium ranking (level C) to that of maximum performance (level A), with considerable implications for the internal temperature and the percentage of hours in comfort of users, without the need for use of mechanized and high energy consuming air conditioning systems. These results provide subsidies for the development of more energy efficient public buildings, through the employment of construction systems appropriate to the site and enabling the reduction of costs associated with the maintenance of adequate thermal comfort of its users. / A busca por edificações com melhor desempenho energético tem sido alvo de diversas pesquisas, visto da crise energética que o Brasil e o mundo vêm enfrentando e a necessidade de um caminho mais sustentável para as edificações. Neste contexto, esta dissertação apresentou a análise da envoltória (vedações verticais e cobertura) de uma edificação escolar cujo objetivo é a otimização de seu desempenho termoenergético e a obtenção de melhores níveis de conforto térmico interno para os seus usuários. O objeto de estudo foi um edifício padrão para salas de aula de escolas públicas do município de Goiânia-GO cujas dimensões e características espaciais não foram alteradas significativamente; sendo analisados somente os componentes construtivos que caracterizam a sua envoltória. A avaliação termoenergética da edificação proposta baseou-se na metodologia do Regulamento Técnico da Qualidade para Eficiência Energética de Edifícios Comerciais, de Serviços e Públicos - RTQ-C do Programa Brasileiro de Etiquetagem em Edificações (PBE Edifica), o qual estabelece parâmetros para a classificação do desempenho energético através da Etiqueta Nacional de Conservação de Energia (ENCE). Para tanto, foram realizadas análises da envoltória da edificação segundo o método prescritivo, baseado em cálculos e parâmetros pré-estabelecidos pelo regulamento, e o da simulação computacional, com a criação de cenários utilizando materiais e soluções recomendadas pelo regulamento e normas técnicas de desempenho de edificações (ABNT NBR 15575:2013) e desempenho térmico em edifícios (ABNT NBR 15220:2005), ambas referenciadas pelo RTQ-C. Para a simulação foi utilizado o software DesignBuilder. Os modelos simulados foram avaliados segundo dois critérios: a temperatura interna do ar e o conforto térmico dos usuários definido pelo índice PMV. Os resultados foram aplicados à metodologia do RTQ-C e demonstram que a mudança no tipo de alvenaria e na cobertura do modelo original, com a incorporação de elementos de proteção solar nas aberturas, possibilitam que a classificação final da ENCE passe de uma classificação mediana (nível C) para o de máximo desempenho (nível A); com consideráveis implicações na temperatura interna e no percentual de horas em conforto dos usuários, sem a necessidade de emprego de sistemas de climatização mecanizados e de elevado consumo energético. Tais resultados fornecem subsídios para a elaboração de edifícios públicos energeticamente mais eficientes, empregando sistemas construtivos adequados ao local e que possibilitem a redução de custos associados à manutenção do adequado conforto térmico de seus usuários.

Page generated in 0.0189 seconds