• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2068
  • 47
  • 22
  • 22
  • 22
  • 21
  • 16
  • 14
  • 8
  • 5
  • 5
  • 5
  • 3
  • 3
  • 1
  • Tagged with
  • 2149
  • 1170
  • 333
  • 299
  • 273
  • 241
  • 222
  • 190
  • 185
  • 173
  • 170
  • 135
  • 127
  • 110
  • 104
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Medidas da razão K/[pi] na radiação cósmica

Mahon, Jose Roberto Pinheiro 10 March 1986 (has links)
Orientador: Armando Turtelli Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-14T15:15:05Z (GMT). No. of bitstreams: 1 Mahon_JoseRobertoPinheiro_M.pdf: 2913295 bytes, checksum: d7a5507381ba8e7278d0b3cb799ec649 (MD5) Previous issue date: 1986 / Resumo: No presente trabalho, realizamos as medidas da razão K/p na radiação cósmica. Para tal medimos suas vidas médias e seus fluxos. Na obtenção do fluxo de kaons usamos detetor Cerenkov, e na obtenção de pions os detetores de cintilação. Como resultado final obtivemos uma razão K/p na ordem de 0,2 / Abstract: We determine K/p ratio at sea level through the measurement of their mean lifes. Mean life of K was measured using a Cerenkov detector while for p we used a plastic scintillator detector. Our final result was K/p ~ 0,2 / Mestrado / Física / Mestre em Física
12

Novas emissões laser em CD3OD e efeitos de saturação em CD3OD, 13CH3OH e CD3OH

Telles, Edjar Martins 15 June 1990 (has links)
Orientador: Daniel Pereira / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-13T22:20:18Z (GMT). No. of bitstreams: 1 Telles_EdjarMartins_M.pdf: 3039979 bytes, checksum: eb8f1d18d2311754f6289353507560ca (MD5) Previous issue date: 1990 / Resumo: A molécula de CD3OD é uma das mais eficientes fontes de radiação laser no infravermelho longínquo (IVL) do espectro eletromagnético, quando bombeada opticamente por lasers de CO2 convencionais (~ 60MHz de largura de curva de ganho) .Neste trabalho, estendemos o estudo na busca de novas emissões laser IVL utilizando, pela primeira vez, um laser de CO2 em guia de onda (~ 290MHz de largura de curva de ganho) como fonte de bombeamento óptico. A grande sintonizabilidade do laser de CO2 em guia de onda com respeito aos lasers de CO2 convencionais, possibilita o bombeamento de novas transições infravermelho (IV) de grande offset. Esta característica marcante do laser de bombeamento associada a utilização de uma eficiente cavidade FABRY-PEROT como laser IVL permitiu-nos a identificação de 38 novas emissões no IVL com comprimentos de onda no intervalo de 38.1mm à 455.2mm. Para todas as novas emissões, determinação precisa do offset da transição de absorção foram realizadas através da técnica do LAMB DIP TRANSFERIDO, além das medidas de polarização relativa e intensidade. Apresentamos, pela primeira vez, medidas diretas do offset de transições de absorção, com resolução SubDoppler realizados dentro da própria cavidade laser IVL usandodetecção fotoacústica. Experimentos de espectroscopia de saturação também foram realizados utilizando 13CH3OH, CD3OH e CD3OD como meios absorvedores. Com um adequado sistema experimental foi possível identificar 5 novas transições IV para o 13CH3OH, 7 para o CD3OH e 38 para o CD3OD. Destas últimas, 26 tem associado a si transições laser no IVL / Abstract: Not informed. / Mestrado / Física / Mestre em Física
13

Espectro vertical de múons induzidos por uma cascata hadrônica na atmosfera

Mundim Filho, Luiz Martins 06 July 1990 (has links)
Orientador: Jose Bellandi Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-13T22:18:07Z (GMT). No. of bitstreams: 1 MundimFilho_LuizMartins_M.pdf: 941563 bytes, checksum: 281989f8cc35c5a2148bf742af3be736 (MD5) Previous issue date: 1990 / Resumo: Estuda-se neste trabalho o comportamento vertical das componentes da radiação cósmica na atmosfera na região de altas energias, com livre caminho médio de interação constante, resolvendo-se as equações de difusão no contexto do modelo de partícula líder . Introduz-se o método de ordenação de operadores exponenciais de Feynman no parâmetro de profundidade, como uma nova sistemática para se resolver as equações de difusão. Compara-se, então, as soluções obtidas com dados experimentais raios cósmicos ao nível do mar / Abstract: We analyze the vertical behavior of the cosmic-rays components in the atmosphere at the high energy region. Assuming constant the interaction mean free path, we solve diffusion equations with the leading particle model. In order to solve diffusion equations we use a Feynman-Iike procedure of ordered exponential operators. Our solutions are compared with cosmic-rays experimental data at sea level / Mestrado / Física / Mestre em Física
14

Datação com o método dos traços de fissão : estudo da dosimetria de neutrons com filmes finos de urânio natural

Iunes, Pedro Jose 06 June 1990 (has links)
Orientador: Julio Cesar Hadler Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-13T22:17:07Z (GMT). No. of bitstreams: 1 Iunes_PedroJose_M.pdf: 1872468 bytes, checksum: 1d52db3ca9bb19a3ae85a36fadb2de2d (MD5) Previous issue date: 1990 / Resumo: Neste trabalho, descreve-se sinteticamente a datação com o método dos traços de fissão, MTF, enfocando-se seus dois aspectos mais polêmicos: a falta de um consenso sobre o valor da constante de desintegração por fissão espontânea do 238U, lF, e a inexistência de uma dosimetria de neutrons (medida da fluência de neutrons a que deve ser submetido o mineral a ser datado pelo MTF) que seja aceita sem restrições pelos pesquisadores que utilizam o MTF. A seguir, descreve-se os procedimentos experimentais e os resultados obtidos dentro de um estudo que utilizou filmes finos de urânio natural como dosímetros de neutrons. A partir dos resultados obtidos neste trabalho, pode-se concluir que as características da dosimetria com filmes finos de urânio natural a colocam em uma posição importante em estudos que visem utilizar o MTF como um método independente de outros métodos de datação de minerais / Abstract: Not informed. / Mestrado / Física / Mestre em Física
15

Datação de obsidianas com o método dos traços de fissão

Araya, Ana Maria Osorio 30 December 1990 (has links)
Orientadores: Julio Cesar Hadler Neto, Giulio Bigazzi / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-13T22:17:54Z (GMT). No. of bitstreams: 1 Araya_AnaMariaOsorio_D.pdf: 1229361 bytes, checksum: 5b8b9c7b766d7e1db708b048a8ca92e9 (MD5) Previous issue date: 1990 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Física / Doutor em Ciências
16

Desenvolvimento de um sistema postal para o controle de qualidade de dosimetrias realizadas em feixes de fótons produzidos em aceleradores lineares de uso clínico

Di Prinzio, Renato 27 July 1984 (has links)
Orientador: Carlos Eduardo de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-14T09:01:44Z (GMT). No. of bitstreams: 1 DiPrinzio_Renato_M.pdf: 2390522 bytes, checksum: 8a764220f992a32f84dbc9700e22524c (MD5) Previous issue date: 1984 / Resumo: Muitos são os parâmetros envolvidos no perfeito funcionamento de um acelerador linear de elétrons de uso clínico. Esses parâmetros devem sofrer uma periódica verificação a fim de que sejam evitados desvios que possam acarretar erros indesejáveis aos tratamentos efetuados com esses aparelhos. Essa verificação é usualmente feita por físicos hospitalares com equipamentos especiais para esse fim. Com o intuito de se fornecer auxílio e ao mesmo tempo aprimorar os serviços realizados pelo físico hospitalar, os órgãos responsáveis pelo controle e utilização das radiações ionizantes têm realizado amplos estudos. Um desses estudos levou à implantação do sistema postal para a verificação da dosimetria realizada nos irradiadores clínicos e nos parâmetros de tais aparelhos que são responsáveis pela obtenção dos resultados esperados nos tratamentos de radioterapia. No entanto os sistemas desenvolvidos para serem utilizados no controle de qualidade postal de dosimetria de aceleradores lineares apenas verificam a dose absorvida em profundidade. Neste trabalho propõe-se um sistema postal que, embora seja mais dispendioso do que os existentes, permite a verificação, além da dose absorvida em duas profundidades diferentes, da homogeneidade do campo de radiação e sua coincidência com o campo luminoso do aparelho, da distância entre o foco e a superfície de tratamento e da energia nominal do feixe de radiação. Esses parâmetros são importantes para o funcionamento de tais aparelhos e também servem como guias para a determinação dos desvios que podem, eventualmente, ocorrer na determinação da dose absorvida. O sistema desenvolvido neste trabalho utiliza a água como material equivalente ao tecido muscular, dosímetros termoluminescentes para a medida de dose absorvida e filme radiográfico para a determinação da coincidência de campos e distância de tratamento. A energia nominal do acelerador é determinada através do filme e dos dosímetros termoluminescentes. O sistema desenvolvido foi testado em aceleradores de 4 a 18 MV de clínicas de radioterapia dos estados de São Paulo e Rio de Janeiro, tendo apresentado ótimos resultados / Abstract: There are a great number of parameters involved in the performance of a clinical linear accelerator. These parameters must be verified periodically to eliminate errors in the treatment performed. Such verifications are usually made by clinical physicists with special equipment¿s. With the intent of helping and optimizing the physicists work, the organizations responsible for the control and utilization of ionizing radiation¿s have conducted a number of studies. A result of these studies led to the implementation of a postal system for, the verification of the dosimetry of clinical irradiators and of their parameters which are relevant to the success of, radiotherapy. The system developed to be used in the quality assurance of linear accelerators only, verifies the absorbed depth dose given by these machines. In this work a different system is proposed which is able to verify the absorbed depth dose given at two different depths, the irradiation field homogeneity and its coincidence with the light field of the machine, the source to surface distance used and the beam nominal energy. These radiation field parameters are very important in the tumour treatment and they may help in the determination of the error sources of the absorbed depth dose. The system developed uses a water phantom, LiF thermoluminescent dosimeters and a radiographic film to evaluate such parameters. The postal system developed in this work has been tested in linear accelerators of 4 to 18 MV with good results / Mestrado / Física / Mestre em Física
17

Estimativa das radiações ultravioleta (UV), fotossintéticamente ativa (PAR) e infravermelha (IV) em função da razão de insolação

Corrêa, Fábio Henrique Pires [UNESP] 24 November 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-11-24Bitstream added on 2014-06-13T20:09:18Z : No. of bitstreams: 1 correa_fhp_me_botfca.pdf: 856592 bytes, checksum: bf45cc8aebe48cc06267d26df357b336 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O trabalho descreve a análise da transmissividade atmosférica da média mensal das radiações Global K T), Ultravioleta K TUV F t i tetic me te Ati K TPAR e I f e me h K TIV) em função da razão de insolação N ). As equações de estimativas das frações KT, KTUV, KTPAR e KTIV em função de (n/N) foram apresentadas e discutidas para os agrupamentos dos dados anual, sazonal e mensal. A base de dados das radiações Global (G), Ultravioleta (UV), Fotossinteticamente Ativa (PAR), Infravermelha (IV) e o número de horas de brilho solar (n) foram medidas no período de 2001 a 2005 em Botucatu/SP/Brasil. Os resultados da análise mostram que existe uma correlação entre a transmissividade atmosférica KT, KTUV, KTPAR e KTIV, com a razão de insolação (n/N), em Botucatu. Os valores de KT, KTUV, KTPAR e KTIV e insolação (n/N) foram menores na estação chuvosa (alta concentração de nuvens e vapor d'ág e m i e t ec b ix c ce t de e e p d’ ág e t concentração de aerossóis). Os valores de KT variaram de 47,1% em janeiro a 60,4% em abril, com média de 55,0%; para KTUV 3,66% em janeiro a 4,13% em setembro, com média de 40,0%; KTPAR de 60,7% em janeiro a 76,3% em abril, com média de 69,0%; KTIV de 38,8% para 75,1% com média de 46,2%. O valor da razão de insolação variou de 38,8% em janeiro para 75,0% em agosto, com uma média de 58,0%. Os resultados obtidos com os modelos de estimativas de Angström mostram que as correlações de KT, KTUV, KTPAR e KTIV em função da razão de insolação (n/N) para agrupamentos total dos dados diários (anual) se ajustaram a dois tipos de equações de regressão: linear e parabólico com coeficientes de correlações R2 variando entre 0,750 a 0,880. Na validação do modelo linear... / The paper deals with the atmospheric transmission (solar fractions Ki) in monthly scale by hi e ti g b K T t i et K TUV), photosynthetically active K TPAR d i f ed K TIR) solar fractions. Estimated equations KT, KTUV, KTPAR and KTIR as a function of n/N were presented and discussed for the annual, seasonal and monthly solar radiation database. The sunshine values and the global (G), ultraviolet (UV), photosynthetically active (PAR) and infrared (IR) radiations database was measured in the period of 2001 to 2005 in Botucatu – SP – Brazil. The results of climate analysis show a correlation between the solar fractions KT, KTUV, KTPAR and KTIR with the relative sunshine duration (n/N) in Botucatu. The values of KT, KTUV, KTPAR and KTIR and relative sunshine duration (n/N) were lower in the rainy season (high concentration of clouds and water vapor) and higher in the dry season (low concentration of clouds and water vapor and high concentration of aerosols). The KT values ranged from 47,1% in January to 60,4% in April, with a mean of 55,0%; KUV from 3,66% in January to 4,13% in September, with a mean of 40,0%; KPAR from 60,7% in January to 76,3% in April, with a mean of 69,0%; KIR from 38,8% to 75,1%, with a mean of 46,2%. The relative sunshine duration values ranged from 38,8% in January to 75,0% in August, with a mean of 58,0%. The results of the annual estimated models show that the KT, KTUV, KTPAR and KTIR correlations due to relative sunshine duration fitted to the linear and parabolic correlation equations... (Complete abstract click electronic access below)
18

Estimativa das radiações ultravioleta (UV), fotossintéticamente ativa (PAR) e infravermelha (IV) em função da razão de insolação /

Corrêa, Fábio Henrique Pires, 1985- January 2011 (has links)
Orientador: João Francisco Escobedo / Banca: Dinival Martins / Banca: Alexandre Dal Pai / Resumo: O trabalho descreve a análise da transmissividade atmosférica da média mensal das radiações Global K T), Ultravioleta K TUV F t i tetic me te Ati K TPAR e I f e me h K TIV) em função da razão de insolação N ). As equações de estimativas das frações KT, KTUV, KTPAR e KTIV em função de (n/N) foram apresentadas e discutidas para os agrupamentos dos dados anual, sazonal e mensal. A base de dados das radiações Global (G), Ultravioleta (UV), Fotossinteticamente Ativa (PAR), Infravermelha (IV) e o número de horas de brilho solar (n) foram medidas no período de 2001 a 2005 em Botucatu/SP/Brasil. Os resultados da análise mostram que existe uma correlação entre a transmissividade atmosférica KT, KTUV, KTPAR e KTIV, com a razão de insolação (n/N), em Botucatu. Os valores de KT, KTUV, KTPAR e KTIV e insolação (n/N) foram menores na estação chuvosa (alta concentração de nuvens e vapor d'ág e m i e t ec b ix c ce t de e e p d' ág e t concentração de aerossóis). Os valores de KT variaram de 47,1% em janeiro a 60,4% em abril, com média de 55,0%; para KTUV 3,66% em janeiro a 4,13% em setembro, com média de 40,0%; KTPAR de 60,7% em janeiro a 76,3% em abril, com média de 69,0%; KTIV de 38,8% para 75,1% com média de 46,2%. O valor da razão de insolação variou de 38,8% em janeiro para 75,0% em agosto, com uma média de 58,0%. Os resultados obtidos com os modelos de estimativas de Angström mostram que as correlações de KT, KTUV, KTPAR e KTIV em função da razão de insolação (n/N) para agrupamentos total dos dados diários (anual) se ajustaram a dois tipos de equações de regressão: linear e parabólico com coeficientes de correlações R2 variando entre 0,750 a 0,880. Na validação do modelo linear... (Resumo completo, clicar aesso eletrônico abaixo) / Abstract: The paper deals with the atmospheric transmission (solar fractions Ki) in monthly scale by hi e ti g b K T t i et K TUV), photosynthetically active K TPAR d i f ed K TIR) solar fractions. Estimated equations KT, KTUV, KTPAR and KTIR as a function of n/N were presented and discussed for the annual, seasonal and monthly solar radiation database. The sunshine values and the global (G), ultraviolet (UV), photosynthetically active (PAR) and infrared (IR) radiations database was measured in the period of 2001 to 2005 in Botucatu - SP - Brazil. The results of climate analysis show a correlation between the solar fractions KT, KTUV, KTPAR and KTIR with the relative sunshine duration (n/N) in Botucatu. The values of KT, KTUV, KTPAR and KTIR and relative sunshine duration (n/N) were lower in the rainy season (high concentration of clouds and water vapor) and higher in the dry season (low concentration of clouds and water vapor and high concentration of aerosols). The KT values ranged from 47,1% in January to 60,4% in April, with a mean of 55,0%; KUV from 3,66% in January to 4,13% in September, with a mean of 40,0%; KPAR from 60,7% in January to 76,3% in April, with a mean of 69,0%; KIR from 38,8% to 75,1%, with a mean of 46,2%. The relative sunshine duration values ranged from 38,8% in January to 75,0% in August, with a mean of 58,0%. The results of the annual estimated models show that the KT, KTUV, KTPAR and KTIR correlations due to relative sunshine duration fitted to the linear and parabolic correlation equations... (Complete abstract click electronic access below) / Mestre
19

Radiação solar difusa horária incidente em superfícies inclinadas: fatores de correção, evolução diurna e modelos de estimativa

Souza, Adilson Pacheco de [UNESP] 04 May 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-05-04Bitstream added on 2014-06-13T21:04:35Z : No. of bitstreams: 1 souza_ap_dr_botfca.pdf: 11943676 bytes, checksum: 797553a48d92dcf2a6fc90d067b1ffea (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Universidade Estadual Paulista (UNESP) / A radiação global incidente em superfícies inclinadas é dada pelas componentes direta, difusa e refletida. As radiações direta e refletida apresentam comportamentos geométricos definidos e variações sazonais dependentes das medidas na horizontal. A grande dificuldade é avaliar o comportamento da radiação difusa, dada pelas subcomponentes circunsolar, isotrópica e anisotrópica. Este trabalho objetivou avaliar as medidas horárias da radiação difusa em superfícies inclinadas a 12,85º (latitude local – 10°), 22,85º (latitude local) e 32,85º (latitude local + 10°) com a face voltada para o Norte, nas condições climáticas de Botucatu, SP, com o através do anel de sombreamento Melo-Escobedo. Para as correções geométricas, astronômicas, isotrópicas e anisotrópicas foram desenvolvidos fatores de correção numéricos totais que englobam quatro parâmetros: ângulo zenital, ângulo de inclinação, epsilon e delta (que inferem sobre a interação atmosférica da radiação). Foram geradas equações estatísticas de estimativa da radiação difusa horária com base na radiação global horizontal em agrupamentos de dados anuais e mensais. Avaliou-se vinte modelos apresentados na literatura para estimativa da radiação difusa horária, nas três inclinações e em diferentes condições de cobertura de céu. O período de dados considerado no estudo foi de 1998 a 2007, com medidas realizadas entre 04/1998 a 08/2001 para a inclinação de 22,85º; de 09/2001 a 02/2003 para 12,85º e de 01/2004 a 12/2007 para a inclinação de 32,85º. Em todos os períodos de medidas, os valores as três irradiações foram comparadas com medidas realizadas em superfícies horizontais. O aumento do ângulo de inclinação propicia diminui dos fatores de correção numéricos da... / The global radiation incident on inclined surfaces is given by the components direct, diffuse and reflected. The direct and reflected radiation exhibit behaviors defined geometric and seasonal variations of the dependent measures horizontally. The great difficulty is to evaluate the behavior of the diffuse radiation, given by the subcomponents circunsolar, isotropic and anisotropic. In this study, hourly measurements of diffuse radiation on inclined surfaces to 12.85 ° (local latitude - 10 °), 22.85 ° (local latitude) and 32.85 ° (local latitude + 10 °) to face the North and of the climate of Botucatu, SP, through the ring with the shading Melo- Escobedo. For the geometric corrections, astronomical, isotropic and anisotropic correction factors were developed numerical totals that include four parameters: zenith angle, tilt angle, epsilon and delta (which infer about the interaction of atmospheric radiation). Statistics were generated equations for estimating hourly diffuse radiation based on global radiation on horizontal groupings of annual and monthly data. We evaluated twenty models in the literature to estimate hourly diffuse radiation, the three slopes and under different sky coverage. The data period considered in the study was from 1998 to 2007, with measurements taken between 04/1998-08/2001 for the inclination of 22.85 °; of 09/2001-02/2003 to 12.85 º and 01/2004 12/2007 for the inclination of 32.85 degrees. In all periods of measurements, values three irradiations were compared with measurements made on horizontal surfaces. The increase of the inclination angle decreases provides the numerical correction factors of diffuse radiation. In the intermediate conditions of sky coverage there is a decrease in performance with the correct numerical factors for the shading ring, however, the rates of adjustment are higher than... (Complete abstract click electronic access below)
20

Avaliação da dose de radiação absorvida em exames radiológicos durante o planejamento radioterápico

Camargo, Rafaela Ferraz de [UNESP] 18 March 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-18Bitstream added on 2015-01-26T13:30:40Z : No. of bitstreams: 1 000794951.pdf: 1115711 bytes, checksum: 4c1e59b3111229911b6794fde269fab1 (MD5) / A radioterapia é uma modalidade médica que emprega radiações ionizantes para o tratamento de doenças. O sucesso da terapêutica depende de vários fatores, dentre eles a liberação precisa da dose de radiação no volume tumoral e a perfeita reprodutibilidade diária das orientações prescritas na ficha técnica do paciente. A delimitação do campo de radiação, o qual deve abranger todo o tumor e permitir uma margem de segurança que considere a movimentação anatômica, é feita durante os procedimentos de planejamento radioterápico. Nesta etapa do tratamento, o médico radioterapeuta, auxiliado pelo físico médico e o tecnólogo em radiologia, utiliza técnicas radiográficas através de um sistema de escopia para visualização do volume alvo de irradiação, e realiza imagens radiográficas estáticas para documentação do caso clínico. Na rotina dos procedimentos de planejamento radioterápico, normalmente não é feita a quantificação da dose de radiação liberada no procedimento, devido principalmente à grande e exaustiva agenda de atividades dos profissionais envolvidos. Neste trabalho foi avaliada a dose de radiação liberada em exames radiológicos realizados durante o planejamento radioterápico, avaliando a influência desta dose no total de exposições em que o paciente foi submetido durante todo o curso da radioterapia. A pesquisa consistiu no acompanhamento dos procedimentos de planejamento radioterápico executadas no Serviço Técnico de Radioterapia da Faculdade de Medicina da UNESP de Botucatu, extraindo os valores das técnicas radiográficas empregas para diferentes planejamentos. Após a caracterização individualizada do planejamento, as técnicas radiográficas utilizadas em cada um dos casos clínicos, foram repetidas e as doses de radiação liberadas no procedimento foram quantificadas por meio de detectores de radiação específicos e calibrados para a energia dos raios-x de ... / Radiotherapy is a medical modality that uses ionizing radiation for the treatment of diseases. The treatment success depends on several factors, including the precise release of the radiation dose in the tumor volume and the perfect daily reproducibility of the guidelines prescribed in the technical sheet of the patient. The delimitation of the radiation field, which should cover the entire tumor and allow a safety margin that considers the anatomical movement, is taken during the procedures of the radiotherapy planning. At this stage of treatment, the radiotherapist physician, aided by the medical physicist and the technologist in radiology, utilizes radiographic techniques through a system of scopy to visualize the target volume of irradiation, and performs static radiographic images to document the clinical case. In the routine of the radiotherapy planning procedures, usually is not performed the quantification of the radiation dose released in the procedure, mainly due to the large and exhaustive schedule of activities of the professionals involved. In this study, was assessed the radiation dose released in radiological examinations performed during the radiotherapy planning, evaluating the influence of this dose in the exposures total in which the patient has undergone throughout the radiotherapeutic procedure. The research consisted in monitoring the radiotherapy planning procedures performed at UNESP, “Serviço Técnico de Radioterapia” of “Faculdade de Medicina de Botucatu”, extracting the radiographic technique values used for different plannings. After the individualized characterization of the plannning, the radiographic techniques used in each clinical case, were repeated and the radiation doses released in the procedure were quantified by specific radiation detectors and they were calibrated to the energy of the simulation x-ray. It is concluded that the absorbed radiation dose, which ...

Page generated in 0.0322 seconds