• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 102
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 1
  • Tagged with
  • 110
  • 45
  • 37
  • 33
  • 31
  • 28
  • 26
  • 19
  • 18
  • 17
  • 15
  • 14
  • 14
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Adaptador para sensor químico para uso em um tag RFID passivo /

Cruz, Bruna Cristina da, 1986-, Vanti, Marcelo Grafulha, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Elétrica. January 2012 (has links) (PDF)
Orientador: Marcelo Grafulha Vanti. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Elétrica.
2

Metodologias de teste e projecto para a testabilidade de circuitos de radiofrequência

Pinho, António Gabriel de Matos e January 2005 (has links)
Tese de mestrado. Engenharia Electrotécnica e de Computadores (Área de especialização em Informática e Sistemas Digitais). 2005. Faculdade de Engenharia. Universidade do Porto
3

Desenvolvimento de um eletrodo expansível de níquel-titânio para ablação hepática por radiofrequência / Development of an expandable electrode of nickel titanium for radiofrequency ablation

Marques, Marina Pinheiro 01 August 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-12-09T14:27:47Z No. of bitstreams: 1 2016_MarinaPinheiroMarques.pdf: 31908439 bytes, checksum: 46f14a6226402bb30bf87b11553f1169 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-01-10T20:34:07Z (GMT) No. of bitstreams: 1 2016_MarinaPinheiroMarques.pdf: 31908439 bytes, checksum: 46f14a6226402bb30bf87b11553f1169 (MD5) / Made available in DSpace on 2017-01-10T20:34:07Z (GMT). No. of bitstreams: 1 2016_MarinaPinheiroMarques.pdf: 31908439 bytes, checksum: 46f14a6226402bb30bf87b11553f1169 (MD5) / O Hepatocarcinoma é um tipo de tumor hepático com altos índices de morte no mundo todo. Quando diagnosticados em sua fase inicial, os nódulos tumorais de até 3cm podem ser tratados por ablação por radiofrequência (RFA). Este procedimento é realizado por uma incisão minimamente invasiva de um eletrodo, guiado por imagem até o foco do tumor, que entrega a corrente alternada em alta frequência ao tecido e causa a necrose celular por volta de 45°C-60°C. Apesar de oferecer pouco dano e baixo risco de complicações quando comparado a outros tratamentos, a RFA é pouco utilizada no Brasil por ter um custo elevado e poucos profissionais capacitados para realizá-la. Neste trabalho é apresentado o desenvolvimento e análise de um eletrodo ativo monopolar para ser acoplado ao equipamento SOFIA de RFA desenvolvido no Laboratório de Engenharia Biomédica da Universidade de Brasília. Além disso, propõe uma relação entre a potência e geometria do eletrodo para garantir a zona de ablação e o acontecimento do roll-off, evento caracterizado pela variação brusca de impedância após a necrose, com e sem aceleradores, soluções de álcool anidro e ácido acético, injetadas para acelerar a queima. Foi construído um eletrodo guarda-chuva, ativo e monopolar, com liga NiTi com micro-soldagem por laser de fibra Yb. Para avaliação do eletrodo foram realizados análise da solda por microscopia eletrônica de varredura. Para sua validação, foram realizados testes ex vivo em fígado bovino com comparações das dimensões de maior largura, menor largura e profundidade da zona de ablação obtidas com outros 8 eletrodos de eletrocirurgia. Por meio de um teste cego, somente 4 eletrodos foram escolhidos para avaliar as combinações de 40W e 80W de potência a 400kHz por 10min, 20min e 30min. Foram feitas simulações do modelo do eletrodo guarda-chuva de cinco hastes (5H) no software COMSOL e comparado com os resultados in vitro. E, devido as diferenças de propriedades entre um tecido vivo e um ex vivo, foi realizada uma modelagem matemática com um modelo Cole-Cole adaptado, para avaliar a influência da impedância no eletrodo guarda-chuva 5H desenvolvido. O processo de fabricação adotado neste trabalho pode reduzir em até 10x o custo do eletrodo ativo comparado aos modelos comerciais. Os experimentos que testaram o eletrodo mostraram que a potência com 40W por até 30min é possível queimar um volume de até 2,5cm³ a 3cm³. Foi constatada que a geometria adia o acontecimento do roll-off e consequentemente produz zonas de ablação maiores e mais bem definidas que os demais eletrodos testados. Dentre os aceleradores, o álcool anidro combinado com a RFA possui maior potencial de auxílio na necrose tumoral. Este estudo constatou a impedância do tecido influi na densidade elétrica e por isso existe variação entre a ablação produzida em tecidos in vivo e post mortem. __________________________________________________________________________________________________ ABSTRACT / Hepatocellular carcinoma is a type of liver tumor with high death rates around the world. When it is diagnosed at an early stage, tumor nodules of up to 3cm can be treated by radiofrequency ablation (RFA). This procedure is carried out through a minimally invasive incision to insert an electrode which is image-guided to the location of the tumor and delivers an alternate high-frequency current to the tissue, causing cellular necrosis at around 45°C-60°C. In spite of offering little damage and low risk of complications when compared to other treatments, RFA is not often used in Brazil because of its elevated costs and because there are only few professionals that are trained to perform it. This paper presents the development and analysis of an active monopolar electrode that is to be attached to the SOFIA equipment for hepatic RFA developed in the Biomedical Engineering Laboratory of the University of Brasília. In addition, the paper proposes a relation between the potency and geometry of the electrode to ensure the zone of ablation and that the roll-off will happen, which is an event characterized by the precipitous variation of impedance after necrosis, with and without accelerators (solutions of anhydrous alcohol and acetic acid) injected to quicken the burn. An umbrella electrode, active and monopolar, was built with nickel titanium and micro welding by laser of Yb fiber. For the evaluation of the electrode, the analysis of the solder by scanning electron microscope was carried out. For its validation, ex vivo tests were performed on bovine livers, with comparisons of dimensions of larger width, narrow width and depth of the ablation zone obtained with 8 other electrosurgery electrodes. Through a blind experiment, only 4 electrodes were chosen to evaluate the combinations of 40W and 80W of potency at 400kHz per 10min, 20min and 30min. Simulations of the umbrella electrode model with 5 electrodes (5H) were performed in the COMSOL software and compared to the ex vivo results. And due to the difference of properties between live and ex-vivo tissue, a mathematic modeling with and adapted Cole-Cole model was made to evaluate the influence of impedance on the developed 5H umbrella electrode. The manufacturing process used in this work can reduce up to 10x the cost of the active electrode. The experiments that tested the electrode showed that with potency of 40W for up to 30min it is possible to burn a volume of up to 2,5cm³ a 3cm³. We found that the geometry delays the roll-off and consequently produces larger and better-defined ablation zones than any other electrode that was tested. Between the accelerators, anhydrous alcohol combined with RFA is potentially more helpful in tumor necrosis. This study found that tissue impedance influences the electrical density and that is why a variation between the ablation produced on in vivo and post mortem tissues exists.
4

Proposta de uma metodologia de otimização evolucionária robusta utilizando a transformada unscented aplicável a circuitos de Rf/microondas

Leidemer, Maisa Netto 03 1900 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2009. / Submitted by Elna Araújo (elna@bce.unb.br) on 2010-04-01T20:50:35Z No. of bitstreams: 1 2009_MaisaNettoLeidemer.pdf: 1790802 bytes, checksum: 102a7b5f90bae15f2bb2c2f8de9bca2f (MD5) / Approved for entry into archive by Lucila Saraiva(lucilasaraiva1@gmail.com) on 2010-04-15T00:49:29Z (GMT) No. of bitstreams: 1 2009_MaisaNettoLeidemer.pdf: 1790802 bytes, checksum: 102a7b5f90bae15f2bb2c2f8de9bca2f (MD5) / Made available in DSpace on 2010-04-15T00:49:29Z (GMT). No. of bitstreams: 1 2009_MaisaNettoLeidemer.pdf: 1790802 bytes, checksum: 102a7b5f90bae15f2bb2c2f8de9bca2f (MD5) Previous issue date: 2009-03 / Problemas de otimização multiobjetivo na presença de incertezas são muito frequentes na engenharia. A fabricação de dispositivos, como os circuitos de RF/microondas, muitas vezes são afetadas por incertezas associadas aos componentes de fabricação. Desta forma, é desejável uma metodologia de projeto robusto que considere estas incertezas durante o processo de otimização. Esta dissertação propõe tal metodologia de projeto robusto a partir dos conceitos de otimização multiobjetivo evolucionária e análise de sensibilidade. A Transformada Unscented é utilizada para análise da sensibilidade e como ferramenta no algoritmo de otimização robusta. O projeto robusto é definido em três etapas: a caracterização da incerteza associada ao problema, a definição dos parâmetros sensíveis de projeto e a otimização robusta. A metodologia proposta é testada em funções analíticas e é realizado o projeto robusto de um amplificador de potência classe E, que opera na faixa de UHF. _________________________________________________________________________________________ ABSTRACT / Multi-objective optimization problems in the presence of uncertainties occur very often in engineering. The manufacture of devices, for example RF/microwaves circuits, is surrounded by uncertainties associated to the manufacturing components. So it’s desirable to establish a method that renders a robust design in which uncertainties are considered during the optimization process. This dissertation presents this method utilizing the concepts of evolutionary multiobjective optimization and sensitivity analysis. The Unscented Transformation is used in the sensitivity analysis and as an auxiliary tool of robust optimization algorithm. The robust design is a three-part project: the characterization of the uncertainties associated with the problem, the identification of the sensitivity parameters and the robust optimization. The method presented is tested in analytical functions and the robust project of a class-E power amplifier operating in UHF band is elaborated.
5

Aquecimento do plasma por rádio frequência na máquina linear lisa

Rapozo, Candido da Cunha 17 February 1986 (has links)
Orientador: Paulo Hiroshi Sakanaka / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-16T19:26:45Z (GMT). No. of bitstreams: 1 Rapozo_CandidodaCunha_D.pdf: 4658907 bytes, checksum: c20ec29944eee7851e2da1107e8ed729 (MD5) Previous issue date: 1985 / Resumo: Mostramos neste trabalho as características do aparato experimental montado no Instituto de Física da Universidade Federal Fluminense (Máquina Linear tipo Espelho LISA) , para produzir o plasma de hélio por rádio freqüência e estudar o seu comportamento quando confinado por um campo magnético de geometria espelho. O plasma foi produzido por uma fonte de microondas com as seguintes características: fRF = 2,45 GHz e PRF = 800 Watts, que pode funcionar em regime contínuo ou pulsado. Os parâmetros do plasma foram estudados em função do campo magnético externo B0, para duas diferentes configurações: 1. região de grande volume de ressonância; 2. região de pequeno volume de ressonância. Para cada região foi feito o mapeamento axial e radial do campo magnético B0, Bz(r,z) e Br(r,z), afim de se verificar a distribuição espacial e orbital das partículas e obter o tempo de confinamento de energia tomando-se por base a equação do balanço de energia. dTej/dT = aj ¿ Tej/tj (j = 1,2) (1) onde os índices 1 e 2 se referem as regiões de grande e pequeno volume aj, tj, são a razão de aquecimento e o tempo de confinamento de energia respectivamente. No estado estacionário, temos: Tej = ajtj (2) onde Tej é a temperatura eletrônica sendo tj função da pressão, temperatura, campo magnético, campo elétrico, etc. Aplicando a microonda na freqüência ciclotrônica dos elétrons wRF = eB0/meC , medimos a temperatura e a densidade dos elétrons Te e ne o potencial flutuante e o potencial de plasma VF e Vp, e obtivemos, ainda, os perfis do campo elétrico Er, Eq e Ez. Variando a distribuição do campo magnético (B1 e B2) pudemos comparar aj e tj com Tej 0para as duas diferentes configurações. Além da influência do campo magnético externo B0, no aquecimento do elétron na ECRH, foi identificada a absorção ressonante ou conversão de onda incidente em onda de Langmuir, com características de caimento paramétrico e processo de termalização (colisões efetivas e Bremsstrahlung inverso). Ondas íon-acústicas modo lento (w < wci cosq) foram observadas com velocidade de fase: Vf = (kbTe/mi)1/2 cosq . (3) Em decorrência da efetiva influência do potencial de rádio freqüência (RF) induzido (VRF) nas características do plasma, a teoria de Bohm, para sondas em plasma, foi modificada. Considerando-se o efeito da voltagem de RF aplicada na corrente de saturação de íons, deduzindo-se urna nova expressão [1]: o que possibilitou explicar o comportamento da freqüência ressonante do plasma-Sheath, detectada experimentalmente no plasma de baixa temperatura e de baixa densidade eletrônica [2]. O diagnóstico foi feito com sonda eletrostática, plana, móvel (axial e radial), sonda Hall, sonda magnética, bobina diamagnética e espectrógrafo / Abstract: We show in this work the characteristics of an experimental device assembled in the Instituto de Física, Universidade Federal Flurninense (Linear Mirror Type Machine LISA) to produce Helium plasma by RF and to study its behavior when confined by a magnetic field with mirrors. The plasma was produced by a micro-wave generator of, fRF = 2.45 GHz, PRF = 800 Watts, which can be operated in steady or pulsed state. The plasma parameters were studied as a function of external magnetic field B0 with two differents configurations: 1. large resonance region, 2. small resonance region. The axial and radial magnetic field B0 ,Bz(r, z) and Br(r, z) were mapped for each configuration in order to verify the spatial distribution, particle orbits and energy confinement time according to the energy balance equation dTej/dt = aj ¿ Tej/tj (j = 1,2) (1) where aj, tj are heating rate and energy confinement time respectively. In steady state, we have Tej = ajtj (2) where Tej is electron temperature and tj is a function of pressure, temperature, magnetic field, electric field, etc. Applying the micro-wave at the electron cyclotron frequency wRF = eB0/meC we measured the electron temperature and density Te, ne, floating potential and plasma potential, VF, Vp and obtained the electric field profile Er, Eq and Ez. Changing the magnetic field distribution (B1, B2), we can compare aj and tj with Tej for the two configurations. Besides the influence of the external magnetic field, B0, in the electron heating of ECRH, it was identified some resonant absorption or mode conversion to Langmuir wave with characteristics of parametric decay, thermalization process (collisions and inverse Bremsstrahlung) and slow ion acoustic mode (w < wci cosq ) with phase velocity Vph = (kbTe/mi)1/2 cosq. (3) As a consequence of the influence of the induced radio frequency (RF) voltage in the plasma, the Bohm's theory of plasma probe was modified. Considering the effect of RF voltage on the ion saturation current, we derived a new expression [1] which allows to explain the frequency behavior of plasma-Sheath resonance, detected experimentally in a low temperature and low density plasma [2] The diagnostic was done with plane movable electrostatic probe, Hall probe, magnetic probe, diamagnetic coil and spectrography / Doutorado / Física / Doutor em Ciências
6

Implementação de um sistema para optimização de amplificadores de potência em microondas, baseado num sintonizador de impedâncias em estado sólido

Sá, Eduardo Lourenço January 2008 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores (Major Telecomunicações). Faculdade de Engenharia. Universidade do Porto. 2008
7

Estruturas EBG em circuitos Microstrip

Lima, Nuno André Rocha Batista de January 2008 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores (Major de Telecomunicações). Faculdade de Engenharia. Universidade do Porto. 2008
8

Metodologia para o estabelecimento de diretrizes para a implantação do Sistema Nacional de Identificação Automática de Veículos – SINIAV

Barbosa, Rone Evaldo 17 July 2017 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-10-31T18:49:43Z No. of bitstreams: 1 2017_RoneEvaldoBarbosa.pdf: 9530204 bytes, checksum: 568a22a7eb55a18f565ee541abaee7d4 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-01-16T13:42:01Z (GMT) No. of bitstreams: 1 2017_RoneEvaldoBarbosa.pdf: 9530204 bytes, checksum: 568a22a7eb55a18f565ee541abaee7d4 (MD5) / Made available in DSpace on 2018-01-16T13:42:01Z (GMT). No. of bitstreams: 1 2017_RoneEvaldoBarbosa.pdf: 9530204 bytes, checksum: 568a22a7eb55a18f565ee541abaee7d4 (MD5) Previous issue date: 2018-01-15 / Esta tese de doutorado tem por objetivo geral propor diretrizes para a implantação do sistema nacional de identificação automática de veículos - SINIAV, com o uso da tecnologia de identificação por radiofrequência - RFID, através de uma análise sistêmica das variáveis tecnológicas, institucionais e regulatórias. Os estudos desenvolvidos consistem na avaliação do atual modelo tecnológico, arranjo institucional e marco regulatório do SINIAV, propondo uma nova metodologia, baseada na aplicação de métodos múltiplos, conforme as necessidades de cada etapa envolvidas no diagnóstico, análise e seleção de alternativas, planejamento e gestão da implantação, monitoramento e avaliação de projetos de sistemas inteligentes de transportes (ITS). Este método foi aplicado para análise do SINIAV e estabelecimento de diretrizes para a sua implantação, de modo a viabilizá-lo como instrumento de identificação automática veicular (IAV), permitindo a coleta automatizada de dados de tráfego em todo o país. / This doctoral thesis aims to propose guidelines for the implementation of the National Automated Vehicle Identification System - SINIAV, that uses radio frequency identification (RFID) technology, through a systemic, technological, institutional and regulatory variables analysis. The studies developed consist of evaluating the current technological model, institutional arrangement and regulatory framework of SINIAV, proposing a new methodology, based on the application of multiple methods, according to the needs of each stage involved in the diagnosis, analysis and alternative selection, planning and management implementation, monitoring and evaluation of Intelligent Transport Systems (ITS) projects. This method was applied to analyze the SINIAV and establish guidelines for its implementation to enable an automatic identification vehicle instrument, allowing to collect traffic data automated throughout the country.
9

Radiofrequência em Região Genital Feminina: um Ensaio Clínico Randomizado

Leal, Mariana Robatto Dantas 28 March 2014 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2015-04-14T16:22:34Z No. of bitstreams: 1 Mariana Robatto Dantas Leal.pdf: 945267 bytes, checksum: e3492a5ff49b9b29729bf23c343647f7 (MD5) / Made available in DSpace on 2015-04-14T16:22:34Z (GMT). No. of bitstreams: 1 Mariana Robatto Dantas Leal.pdf: 945267 bytes, checksum: e3492a5ff49b9b29729bf23c343647f7 (MD5) Previous issue date: 2014-03-28 / A flacidez dos grandes lábios vulvares é uma das principais queixas de mulheres que se submetem às cirurgias plásticas genitais, podendo apresentar impacto na função sexual. A Radiofrequência (RF) é um procedimento não invasivo, eficaz no tratamento da flacidez cutânea facial e corporal, porém não há relatos da sua utilização em grandes lábios vulvares. Objetivo: Avaliar a resposta clínica da RF em grandes lábios. Tipo de estudo: Ensaio clínico randomizado, cego. Material e Métodos: Amostra de 43 mulheres com queixa de flacidez cutânea em grandes lábios, sendo 21 participantes do grupo estudo e 22 do grupo controle. O protocolo consistiu de 8 sessões de RF, 1x/semana. Como instrumentos de avaliação, foram utilizadas fotografias realizadas antes da primeira sessão e oito dias após o término da última sessão, que foram avaliadas pelas próprias pacientes e três profissionais de saúde, através da escala de Likert de 3 pontos (insatisfeita, inalterada, satisfeita) e (piorou, inalterado, melhorou) respectivamente. A satisfação das pacientes foi determinada pelos Testes Qui-Quadrado e Binomial na comparação inter-grupo e intra-grupo, respectivamente. A avaliação dos profissionais foi avaliada pelo Teste Qui-Quadrado. Resultados: Em relação à resposta clínica da RF, 76% das pacientes do grupo estudo e 27% do grupo controle relataram satisfação com o resultado do tratamento (p=0,001). Este resultado foi ratificado pela avaliação dos profissionais (p=0,007; p=0,009; p=0,010). Conclusão: A RF é uma alternativa de tratamento não invasiva, eficaz no tratamento da flacidez cutânea de grandes lábios, inclusive na percepção pessoal.
10

Rizotomia sacral percutanea por radiofrequencia no tratamento da hiperatividade detrusora de origem neurogenica

Ferreira, Rúiter Silva, 1967- 18 May 2005 (has links)
Orientador: Carlos Arturo Levi D'Ancona / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-05T00:01:14Z (GMT). No. of bitstreams: 1 Ferreira_RuiterSilva_M.pdf: 4307875 bytes, checksum: 961cda503abf597975b9a096147c15f4 (MD5) Previous issue date: 2005 / Resumo: A hiperatividade do detrusor neurogênica é decorrente de lesões do sistema nervoso central como traumatismos, doenças degenerativas, doenças inflamatórias, doenças congênitas e acidentes vasculares cerebrais. O tratamento com utilização de drogas anticolinérgicas tem sido a primeira opção no tratamento desses casos. O insucesso do tratamento clínico leva à necessidade de se indicar o tratamento cirúrgico, que inclui a enterocistoplastia, a auto-ampliação vesical e a rizotomia sacra!. O objetivo do estudo foi avaliar a técnica da rizotomia sacral percutânea por meio de radiofreqüência (RF) com utilização de eletrodo 22G e verificar os efeitos na capacidade vesical e na pressão do detrusor no seguimento de 12 meses, em pacientes com lesão medular refratários ao tratamento clínico. Foram avaliados 12 pacientes portadores de lesão medular (7 mulheres e 5 homens) com idades variando de 22 a 58 anos (mediana de 33 anos). Cinco pacientes apresentavam lesão medular em nível cervical, cinco em nível torácico e dois em nível lombar. Dez pacientes apresentavam lesão medular completa e dois, lesão incompleta. O intervalo entre a ocorrência da lesão e a data do procedimento variou de 8 a 96 meses (mediana de 60 meses). Todos os pacientes apresentavam hiperatividade detrusora e foram submetidos ao bloqueio anestésico bilateral da terceira raiz sacral, usando 3ml de bupivacaína a 0,5 %, sem adrenalina, controlado por fluoroscopia. Quatro pacientes foram excluídos do estudo porque não apresentaram aumento superior a 100% da capacidade vesical após esse procedimento. No projeto piloto, três pacientes foram submetidos à rizotomia sacral percutânea por RF utilizando-se eletrodo 18G. Porém, na avaliação 30 dias após o procedimento não foi observado melhora nos parâmetros urodinâmicos. Indicou-se nova rizotomia com eletrodo de menor calibre. Esse grupo de pacientes e mais outros cinco pacientes foram submetidos à rizotomia sacral percutânea por RF utilizando-se eletrodo 22G. Todos os pacientes foram avaliados através de estudo videourodinâmico um mês, seis meses e 12 meses após o procedimento e a capacidade vesical e a pressão do detrusor foram analisadas. Foi observada melhora significativa da capacidade vesical após 12 meses. A média da capacidadevesicalaumentoude 100,2ml (:I: 57,1ml) para 282,9ml (:I:133,4ml),p < 0,05. A pressão do detrusor reduziu-se significativamente no primeiro mês, de 82,4 cm H20 (:I:31,7 cm H20) para 58,5 cm H20 (:I:27,6 cm H20), p < 0,05. No entanto, na avaliação de 6 meses observou-se aumento da pressão detrusora. Aos 12 meses, observou-se retorno da hiperatividade do detrusor em todos os pacientes. Três pacientes com sintomas de disreflexia autonômica demonstraram total alívio dos sintomas; um paciente apresentou resolução do refluxo vésico-ureteral após 6 meses e outro paciente apresentou perda das ereções após o procedimento. Nenhuma complicação séria foi observada durante o seguimento. A rizotomia sacral percutânea por RF, utilizando-se eletrodo 22G, é uma técnica minimamente invasiva, simples e de baixa morbidade. Os resultados após 12 meses de seguimento demonstraram aumento significativo da capacidade vesical, porém, o mesmo não foi observado quanto à redução da pressão do detrusor / Abstract: Neurogenic detrusor overactivity is a result of injuries to the central nervous systetn, such as traumas, degenerative diseases, inflammatory diseases, congenital diseases and stroke. The anti-cholinergic therapy has been the first choice treatment in these cases. Failures in the clinical treatment should indicate the surgical treatment, which includes the enterocystoplasty, the bladder auto-augmentation and a sacral rhizotomy. The aim of the study was to evaluate the percutaneous radioftequency sacral rhizotomy using a 22 gauge electrode and verify the effects on the bladder capacity and the detrusor pressure in a follow-up of 12 months in patients presenting spinal cord injury reftactory to the clínical treatment. Five men and seven women, ages ranging ftom 22 to 58 years- old (median 33), presenting spinal cord injury were evaluated. Five patients showed a lesion to the spinal cord at the cervical region, five presented a thoracic injury and two a lumbar injury. Ten patients had a traumatic complete spinal cord lesion and two an incomplete lesion. The period of time between the occurrence of the lesion and the procedure was ftom 8 to 96 months (median = 60 months). AlI patients had detrusor overactivity and were submitted to a bilateral anesthetic block of the 3rd sacral root using 3 rol of 0.5% bupivacaine, without adrenaline, under fluoroscopic control. Four patients were excluded ftom this study because they did not show an increase of bladder capacity greater than 10QO-aIfoter the procedure. In the pilot project, three patients underwent a percutaneous radioftequency sacral rhizotomy, using a 18 gauge electrode. However, an evaluation made 30 days after the procedure did not show an improvement in the urodynamic parameters. Therefore, a new rhizotomy using a smaller electrode was done. This group of patients and five other patients were submitted to a percutaneous radioftequency sacral rhizotomy using a 22 gauge electrode. AlI patients were evaluated through a videourodynamic study one month, six months and 12 months after the procedure and the bladder capacity and detrusor pressure were analyzed. After 12 nionths, there was a significant improvement in the bladder capacity. The mean bladdercapacityincreasedtrom 100,2rol (::t57,1rol)to 282,9rol (::t133,4rol),p < 0,05. In the first month, the detrusor pressure showed a significant reduction ftom 82,4 cm H20 (:f:31,7 cm H20) to 58,5 cm H20 (::t27,6 cm H20), p < 0,05. However, in the evaluation done after 6 months, an increase in the detrusor pressure was observed. After 12 months, alI patients showed again detrusor overactivity. Three patients with autonomic dysteflexia symptoms showed total relief of the symptoms; one patient presented resolution of the vesicoureteral reflux after six months and another one had an erectile dysfunction after the procedure was carried out. No serious complication was observed. Percutaneous radioiTequency sacral rhizotomy using a 22 gauge electrode is a simple, minimally invasive and low morbidity technique. Results after a follow-up of 12 months demonstrated a significant increase in the bladder capacity, although the reduction in the detrusor pressure was not observed. / Mestrado / Cirurgia / Mestre em Cirurgia

Page generated in 0.0847 seconds