• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 63
  • Tagged with
  • 63
  • 63
  • 21
  • 18
  • 15
  • 15
  • 15
  • 12
  • 12
  • 9
  • 9
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo comparativo de protocolos tomográficos na aquisição das imagens para confecção de modelos de prototipagem / Comparative study of the tomographic protocols for making model prototype

Lima Moreno, Jorge Javier de January 2013 (has links)
A especialidade de Prótese Buco-Maxilo-Facial é responsável por reconstruções complexas da face e do crânio. Entretanto, com a utilização de impressões convencionais, é difícil se alcançar uma adequada adaptação clínica para a reabilitação do paciente. Assim, algumas vêzes, faz-se necessária a obtenção de modelos tridimensionais (3D) que reproduzam a realidade clínica. O objetivo deste estudo é comparar os protótipos obtidos com diferentes protocolos de aquisição de imagem provenientes de distintos aparelhos de tomografia computadorizada com relação à rugosidade superficial, área reconstruída e dose de exposição gerada, procurando estabelecer o mais adequado para a confecção de protótipos de crânio. Para isso, nove protótipos de um fragmento craniofacial seco foram confeccionados. A comparação entre os protótipos quanto à lisura superficial e à área reconstruída foi realizada por meio da Análise de Variância (ANOVA). Nos casos em que a avaliação indicou diferença significativa, foi aplicado como complemento o Teste de Comparações Múltiplas de Tukey. O nível de significância adotado foi de 5%. Em relação à análise de rugosidade as diferenças encontradas não demonstraram correlação com a área reconstruída. Já em relação aos diferentes protocolos, diferenças significativas foram observadas nos protótipos com respeito à área reconstruída e dose de radiação gerada. Pode-se concluir, frente aos resultados encontrados, que as imagens geradas pelos tomógrafos de feixe cônico e feixe em leque, utilizando os protocolos com as resoluções máximas estudadas, estão indicadas para a confecção de protótipos. Contudo, o que deve nortear a seleção do melhor protocolo tomográfico deve ser o propósito da indicação clínica correlacionado com o princípio ALARA (As Low As Reasonably Achievable). / Oral-maxillo-facial prosthodontics is the study of complex face and skull reconstructions. In view of the insufficient degree of adjustment of conventional impression to enable proper clinical rehabilitation, among other reasons, practitioners increasingly resort to 3D models that accurately reproduce the clinical reality. The aim of this study is to determine the optimal selection of imaging device and protocol for use in skull prototyping. The surface roughness and reconstructed area of nine prototypes obtained from a dried craniofacial specimen using different image acquisition protocols and CT devices were measured, in addition to measurements of the radiation dose potentially received by the patient. ANOVA of the surface roughness, reconstructed area and radiation dose data enabled statistical comparisons among the prototypes. Where significant differences were found, Tukey’s multiple-comparison test was conducted, using a significance level of 5%. No correlation was found between surface roughness and reconstructed area. However, significant differences in reconstructed area and radiation dose were found among the different protocols. These results support the use of images generated by CBCT or fan beam CT for the construction of prototypes, using the protocols with the highest resolution. Nevertheless, the selection of the most appropriate TC protocol should be based on the particular clinical indication along with the ALARA (as low as reasonably achievable) principle.
32

Estudo comparativo de cefalogramas realizados sobre reconstruções de tomografia cone beam total e unilaterais da face e telerradiografias convencionais

Liedke, Gabriela Salatino January 2009 (has links)
A possibilidade de exploração das imagens oferecida pela tomografia computadorizada cone beam (TCCB) permite investigações mais detalhadas do paciente. Este estudo, empregando alguns destes recursos, se propôs a comparar medidas cefalométricas realizadas sobre telerradiografias convencionais e reconstruções de perfil total e unilaterais obtidas da TCCB. Análises cefalométricas de 30 pacientes foram realizadas por um examinador calibrado sobre as reconstruções da TCCB e as telerradiografias convencionais. A reprodutibilidade dos fatores cefalométricos foi investigada por meio do coeficiente de correlação intraclasse em cada imagem. O método de Bland-Altman foi utilizado para averiguar a performance diagnóstica de cada imagem em relação às medidas de cada fator cefalométrico. O coeficiente de correlação intraclasse evidenciou semelhança de reprodutibilidade entre os exames. Quando os valores dos fatores cefalométricos foram comparados, observou-se forte concordância diagnóstica entre as mensurações realizadas sobre telerradiografias convencionais e imagens reconstruídas por TCCB. Conclui-se que, em pacientes sem assimetrias faciais importantes, a telerradiografia convencional e as reconstruções total e unilaterais a partir da TCCB oferecem desempenho de reprodutibilidade e resultado de análise cefalométrica semelhantes. / The possibility to explore images afforded by the cone beam computer tomography (CBCT) technique allows investigating patients in more detail. The present study uses some of these resources to compare cephalometric measurements obtained from conventional cephalograms and total and half-skull synthesized cone beam computed tomography (CBCT) cephalograms. Cephalometric analyses of 30 clinically symmetric patients; were conducted by a calibrated examiner on conventional and CBCTsynthesized cephalograms. Reproducibility was investigated using the intraclass correlation coefficient. The Bland-Altman analysis was used to assess the agreement of the measurements from each factor obtained by conventional, total, right and left CBCT-synthesized cephalograms. The intraclass correlation coefficient revealed similar levels of reproducibility. When the measurements obtained from conventional and CBCT-synthesized cephalograms were compared, the Bland-Altman analysis showed a strong agreement between them. Half-skull CBCT-synthesized cephalograms offer the same diagnostic performance and equivalent reproducibility in terms of cephalometric analysis as observed in conventional and total CBCT-synthesized cephalograms.
33

Estudo comparativo de cefalogramas realizados sobre reconstruções de tomografia cone beam total e unilaterais da face e telerradiografias convencionais

Liedke, Gabriela Salatino January 2009 (has links)
A possibilidade de exploração das imagens oferecida pela tomografia computadorizada cone beam (TCCB) permite investigações mais detalhadas do paciente. Este estudo, empregando alguns destes recursos, se propôs a comparar medidas cefalométricas realizadas sobre telerradiografias convencionais e reconstruções de perfil total e unilaterais obtidas da TCCB. Análises cefalométricas de 30 pacientes foram realizadas por um examinador calibrado sobre as reconstruções da TCCB e as telerradiografias convencionais. A reprodutibilidade dos fatores cefalométricos foi investigada por meio do coeficiente de correlação intraclasse em cada imagem. O método de Bland-Altman foi utilizado para averiguar a performance diagnóstica de cada imagem em relação às medidas de cada fator cefalométrico. O coeficiente de correlação intraclasse evidenciou semelhança de reprodutibilidade entre os exames. Quando os valores dos fatores cefalométricos foram comparados, observou-se forte concordância diagnóstica entre as mensurações realizadas sobre telerradiografias convencionais e imagens reconstruídas por TCCB. Conclui-se que, em pacientes sem assimetrias faciais importantes, a telerradiografia convencional e as reconstruções total e unilaterais a partir da TCCB oferecem desempenho de reprodutibilidade e resultado de análise cefalométrica semelhantes. / The possibility to explore images afforded by the cone beam computer tomography (CBCT) technique allows investigating patients in more detail. The present study uses some of these resources to compare cephalometric measurements obtained from conventional cephalograms and total and half-skull synthesized cone beam computed tomography (CBCT) cephalograms. Cephalometric analyses of 30 clinically symmetric patients; were conducted by a calibrated examiner on conventional and CBCTsynthesized cephalograms. Reproducibility was investigated using the intraclass correlation coefficient. The Bland-Altman analysis was used to assess the agreement of the measurements from each factor obtained by conventional, total, right and left CBCT-synthesized cephalograms. The intraclass correlation coefficient revealed similar levels of reproducibility. When the measurements obtained from conventional and CBCT-synthesized cephalograms were compared, the Bland-Altman analysis showed a strong agreement between them. Half-skull CBCT-synthesized cephalograms offer the same diagnostic performance and equivalent reproducibility in terms of cephalometric analysis as observed in conventional and total CBCT-synthesized cephalograms.
34

Inspeção da degradação nos isoladores de compósito de linhas de transmissão através de ensaios não destrutivos

Paolo Jorge Corrêa Greci Pailleule de Oliveira e Silva, Pietro 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T23:16:25Z (GMT). No. of bitstreams: 2 arquivo8677_1.pdf: 10262062 bytes, checksum: d7be982768cc196849460d10e2e1e68d (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Na presente dissertação, nove unidades de isoladores de compósito, das quais oito unidades foram retiradas da linha de transmissão de 230 kV da Chesf após um período de aproximadamente 10 anos em operação, próximas ao local de ocorrência de fratura frágil e cobertas com camadas de poluentes, foram inspecionadas através de radiografia digital empregando três sistemas de CR (radiografia computadorizada) e um sistema de m-CT (microtomografia computadorizada), e também por OM (microscopia óptica) e SEM (microscopia eletrônica de varredura). O material polimérico que recobre o bastão de compósito foi caracterizado com técnicas de XRD (difração de raios-X) e FTIR-DRIFTS (espectroscopia de infravermelho por transformada de Fourier). Através das técnicas de caracterização FTIR-DRIFTS e XRD, o material polimérico que recobre o bastão de compósito foi identificado como silicone tipo PDMS (polidimetilsiloxano) reforçado com a carga de ATH (alumina trihidratada). A inspeção da integridade estrutural através das imagens radiográficas obtidas com os sistemas de CR detectou a presença de várias trincas em quatro unidades de isoladores de compósito retiradas da linha de transmissão. Embora a quantidade de trincas varie de isolador para isolador, elas estão localizadas na região próxima ao cabo e estão dispostas perpendicularmente ao eixo do bastão. Através da inspeção mais detalhada das trincas pela técnica de m-CT, verificou-se que as trincas observadas por CR estão confinadas na camada de silicone que recobre o bastão de compósito e possuem diferentes profundidades. Ademais, em função da maior resolução espacial, as trincas menores que não foram observadas com as técnicas de CR foram detectadas por m-CT. Realizando análise mais detalhada da superfície externa do silicone através do SEM, além da observação das trincas detectadas por técnicas radiográficas e tomográficas, trincas de dimensões submicrométricas dispostas em diversas orientações foram observadas. Para explicar a evolução das trincas dispostas perpendicularmente ao eixo do bastão e detectadas por técnicas radiográficas de CR e m-CT, um modelo foi proposto baseado nos dados obtidos no presente trabalho
35

Estudo da localização topográfica do canal mandibular pela incidência lateral oblíqua de mandibula e análise de distorções lineares apresentadas pela técnica

Andrade, Gainer Raul Jasa January 2013 (has links)
Alguns fatores influenciam no dano ao nervo dentário inferior quando da remoção cirúrgica do terceiro molar, sendo a posição do dente e sua íntima relação com o canal mandibular os de maior relevância na avaliação précirúrgica. Assim, se faz importante que o cirurgião tenha o conhecimento prévio da anatomia da região e a precisa localização do canal mandibular, contemplando os dois planos, vertical e horizontal. Este estudo teve como objetivo analisar a localização topográfica vestíbulo-lingual do canal mandibular em relação ao terceiro molar inferior por meio da incidência lateral oblíqua de mandíbula e suas variações, além de mensurar possíveis distorções dessa técnica. Foram selecionadas vinte e quatro mandíbulas secas que continham ao menos um terceiro molar, nestas foram realizadas duas tomadas radiográficas laterais oblíquas de mandíbula, variando a angulagem vertical em 30 graus (0 e -30). Um examinador treinado e calibrado realizou as mensurações em todas as radiografias. As mesmas foram realizadas do teto do canal mandibular até o ponto mais apical do terceiro molar, com paquímetro digital em negatoscópio com máscara. Baseado na análise das duas medições (0 e -30 graus) para cada caso estudado, e levando em consideração a regra do objeto bucal, o examinador estimou o posicionamento do canal mandibular, sendo: lingual, central ou vestibular em relação ao terceiro molar respectivo. Posteriormente, os resultados foram comparados com os achados pela tomografia computadorizada (padrão-ouro). A análise estatística foi realizada por meio dos testes de sensibilidade, especificidade e acurácia. Os resultados mostraram que a técnica lateral oblíqua de mandíbula, associada a sua variação com -30 graus, foi capaz de estabelecer a posição vestíbulo-lingual do canal mandibular em relação ao terceiro molar. Além disso, quantificou-se a magnificação da imagem na técnica lateral oblíqua, considerando-se a mesma aceitável para o propósito do estudo. / The aim of this study was to evaluate the use of lateral oblique radiography (LOR) at two different incidence angles for the bucco-lingual topographic localization of the mandibular canal with respect to the lower third molar. A total of 24 dry jaws bearing at least one third molar were subject to LOR at vertical incidence angles of 0° and -30°. A trained and calibrated examiner measured the distance between the mandibular canal top to the most apical point of the third molar, using a digital calliper and individual light box for the radiographs. Based on the analysis of the two measurements (incidence angles of 0° and -30°) and considering the buccal object rule, the observer estimated the location of the mandibular canal, which was classified as lingual, central or buccal to the corresponding third molar. Results were compared with the computer tomography images (gold standard). The statistical analysis included sensitivity, specificity and accuracy tests. These results showed that LOR (0° e -30°) could be used to determine the bucco-lingual location of the mandibular canal with respect to the third molar. Although there is a certain magnification in the LOR images; it was demonstrated that the technique could be used for this study proposal.
36

Estudo da localização topográfica do canal mandibular pela incidência lateral oblíqua de mandibula e análise de distorções lineares apresentadas pela técnica

Andrade, Gainer Raul Jasa January 2013 (has links)
Alguns fatores influenciam no dano ao nervo dentário inferior quando da remoção cirúrgica do terceiro molar, sendo a posição do dente e sua íntima relação com o canal mandibular os de maior relevância na avaliação précirúrgica. Assim, se faz importante que o cirurgião tenha o conhecimento prévio da anatomia da região e a precisa localização do canal mandibular, contemplando os dois planos, vertical e horizontal. Este estudo teve como objetivo analisar a localização topográfica vestíbulo-lingual do canal mandibular em relação ao terceiro molar inferior por meio da incidência lateral oblíqua de mandíbula e suas variações, além de mensurar possíveis distorções dessa técnica. Foram selecionadas vinte e quatro mandíbulas secas que continham ao menos um terceiro molar, nestas foram realizadas duas tomadas radiográficas laterais oblíquas de mandíbula, variando a angulagem vertical em 30 graus (0 e -30). Um examinador treinado e calibrado realizou as mensurações em todas as radiografias. As mesmas foram realizadas do teto do canal mandibular até o ponto mais apical do terceiro molar, com paquímetro digital em negatoscópio com máscara. Baseado na análise das duas medições (0 e -30 graus) para cada caso estudado, e levando em consideração a regra do objeto bucal, o examinador estimou o posicionamento do canal mandibular, sendo: lingual, central ou vestibular em relação ao terceiro molar respectivo. Posteriormente, os resultados foram comparados com os achados pela tomografia computadorizada (padrão-ouro). A análise estatística foi realizada por meio dos testes de sensibilidade, especificidade e acurácia. Os resultados mostraram que a técnica lateral oblíqua de mandíbula, associada a sua variação com -30 graus, foi capaz de estabelecer a posição vestíbulo-lingual do canal mandibular em relação ao terceiro molar. Além disso, quantificou-se a magnificação da imagem na técnica lateral oblíqua, considerando-se a mesma aceitável para o propósito do estudo. / The aim of this study was to evaluate the use of lateral oblique radiography (LOR) at two different incidence angles for the bucco-lingual topographic localization of the mandibular canal with respect to the lower third molar. A total of 24 dry jaws bearing at least one third molar were subject to LOR at vertical incidence angles of 0° and -30°. A trained and calibrated examiner measured the distance between the mandibular canal top to the most apical point of the third molar, using a digital calliper and individual light box for the radiographs. Based on the analysis of the two measurements (incidence angles of 0° and -30°) and considering the buccal object rule, the observer estimated the location of the mandibular canal, which was classified as lingual, central or buccal to the corresponding third molar. Results were compared with the computer tomography images (gold standard). The statistical analysis included sensitivity, specificity and accuracy tests. These results showed that LOR (0° e -30°) could be used to determine the bucco-lingual location of the mandibular canal with respect to the third molar. Although there is a certain magnification in the LOR images; it was demonstrated that the technique could be used for this study proposal.
37

Estudo da localização topográfica do canal mandibular pela incidência lateral oblíqua de mandibula e análise de distorções lineares apresentadas pela técnica

Andrade, Gainer Raul Jasa January 2013 (has links)
Alguns fatores influenciam no dano ao nervo dentário inferior quando da remoção cirúrgica do terceiro molar, sendo a posição do dente e sua íntima relação com o canal mandibular os de maior relevância na avaliação précirúrgica. Assim, se faz importante que o cirurgião tenha o conhecimento prévio da anatomia da região e a precisa localização do canal mandibular, contemplando os dois planos, vertical e horizontal. Este estudo teve como objetivo analisar a localização topográfica vestíbulo-lingual do canal mandibular em relação ao terceiro molar inferior por meio da incidência lateral oblíqua de mandíbula e suas variações, além de mensurar possíveis distorções dessa técnica. Foram selecionadas vinte e quatro mandíbulas secas que continham ao menos um terceiro molar, nestas foram realizadas duas tomadas radiográficas laterais oblíquas de mandíbula, variando a angulagem vertical em 30 graus (0 e -30). Um examinador treinado e calibrado realizou as mensurações em todas as radiografias. As mesmas foram realizadas do teto do canal mandibular até o ponto mais apical do terceiro molar, com paquímetro digital em negatoscópio com máscara. Baseado na análise das duas medições (0 e -30 graus) para cada caso estudado, e levando em consideração a regra do objeto bucal, o examinador estimou o posicionamento do canal mandibular, sendo: lingual, central ou vestibular em relação ao terceiro molar respectivo. Posteriormente, os resultados foram comparados com os achados pela tomografia computadorizada (padrão-ouro). A análise estatística foi realizada por meio dos testes de sensibilidade, especificidade e acurácia. Os resultados mostraram que a técnica lateral oblíqua de mandíbula, associada a sua variação com -30 graus, foi capaz de estabelecer a posição vestíbulo-lingual do canal mandibular em relação ao terceiro molar. Além disso, quantificou-se a magnificação da imagem na técnica lateral oblíqua, considerando-se a mesma aceitável para o propósito do estudo. / The aim of this study was to evaluate the use of lateral oblique radiography (LOR) at two different incidence angles for the bucco-lingual topographic localization of the mandibular canal with respect to the lower third molar. A total of 24 dry jaws bearing at least one third molar were subject to LOR at vertical incidence angles of 0° and -30°. A trained and calibrated examiner measured the distance between the mandibular canal top to the most apical point of the third molar, using a digital calliper and individual light box for the radiographs. Based on the analysis of the two measurements (incidence angles of 0° and -30°) and considering the buccal object rule, the observer estimated the location of the mandibular canal, which was classified as lingual, central or buccal to the corresponding third molar. Results were compared with the computer tomography images (gold standard). The statistical analysis included sensitivity, specificity and accuracy tests. These results showed that LOR (0° e -30°) could be used to determine the bucco-lingual location of the mandibular canal with respect to the third molar. Although there is a certain magnification in the LOR images; it was demonstrated that the technique could be used for this study proposal.
38

Planejamento do tamanho do implante dentário utilizando imagens de radiografia panorâmica digital e tomografia computadorizada de feixe cônico

Correa, Leticia Ruhland January 2012 (has links)
O objetivo deste estudo foi comparar o tamanho do implante dentário (largura e comprimento) planejado utilizando-se radiografias panorâmicas digitais (D-pan), reconstruções panorâmicas geradas a partir de Tomografia Computadorizada de Feixe Cônico (TCFC-pan), e imagens transversais de Tomografia Computadorizada de Feixe Cônico (TCFC-transversais), em quatro sistemas de implantes. Para tal, foram avaliados 103 sítios de implantes unitários nas regiões de pré-molares superiores e molares inferiores em 71 pacientes. Em cada paciente foram realizadas uma radiografia panorâmica digital (D-pan) e uma Tomografia Computadorizada de Feixe Cônico (TCFC). Para a realização da D-pan, foi colocada uma esfera de metal de 5 mm de diâmetro na região edêntula para que fosse realizada a calibração linear da imagem. Os dados adquiridos nas TCFC foram reconstruídos em imagens panorâmicas de 10 mm de espessura (TCFC-pan) e em imagens transversais de 1 mm de espessura (TCFC-transversais). Foram realizadas medidas em todas as imagens. Todas as modalidades de imagem foram exibidas no mesmo monitor e avaliadas por três observadores que utilizando o programa PorDios, identificaram quatro pontos de referência no espaço disponível e delimitaram o sítio de implante. Os tamanhos (largura e comprimento) dos implantes foram comparados entre as três modalidades de imagem e as diferenças foram analisadas. Utilizando o software SPSS, foi selecionado o tamanho do implante mais próximo (igual ou menor) que serviria no espaço disponível, baseado nos tamanhos existentes nos quatro sistemas utilizados (Nobel Biocare, Straumann, 3i e Neodent). O tamanho do implante selecionado nas imagens TCFC transversais foi comparado com o tamanho do implante selecionado nas outras duas modalidades (D-pan e TCFC-pan), para cada um dos sistemas separadamente. Como resultado, na maioria das vezes, o tamanho do implante foi menor nas TCFC-transversais, do que quando comparado com D-pan e TCFC-pan. Houve diferença significativa na largura do implante nas regiões de pré-molares entre D-pan e TCFC-pan. O implante foi significantemente mais curto na TCFC-transversal do que na D-pan, nas regiões de molares. A maioria das mudanças ocorreu para um tamanho mais fino e mais curto, que resultou em um tamanho de implante significantemente menor nas TCFC-transversais. Os resultados permitem concluir que quando o implante é planejado utilizandose imagens transversais de TCFC este é selecionado em um tamanho mais fino e mais curto do que quando idealizados em radiografias panorâmicas digitais. / The objective of this study was to compare the implant size (width and length) planned with digital panoramic radiographs, CBCT-generated panoramic views, or CBCT cross-sectional images, in four implant systems. Seventy-one patients with a total of 103 single-unit implants in the upper premolar and/or lower molar regions were examined with digital panoramic radiography (D-PAN) and cone beam computed tomography (CBCT). A 5-mm in diameter metal ball was placed in the edentulous area for the D-PAN. CBCT data sets were reformatted to a 10-mm thick CBCT panoramic view (CBCT-pan) and 1-mm cross-sections (CBCT-cross). Measurements were performed in the images using dedicated software. All images were displayed on a monitor and assessed by three observers who outlined a dental implant by placing four reference points in the site of the implant-to-be. Differences in width and length of the implant-to-be from the three modalities were analyzed. An automated program selected the implant size, which was the closest (smaller or equal) size implant that would fit the measured size, based on the sizes available in four worldwide-used implant systems (Nobel Biocare, Straumann, 3i and Neodent). The implant size selected in the CBCT-cross images was then compared to that selected in the other two modalities (D-PAN and CBCT-pan) for each of the implant systems separately. The implant-to-be (average measurements among observers) was narrower when measured in CBCT-cross compared with both D-PAN and CBCT-Pan. For premolar sites, width also differed significantly between D-PAN and CBCT-pan modalities. The implant-to-be was also significantly shorter when recorded in CBCT-cross than in D-PAN. In premolar sites there were no significant differences in implant length among the three image modalities. It mattered very little for the change in implant step sizes whether CBCT-cross was compared to D-PAN or CBCT-pan images. Our results show that the selected implant size differs when planned on panoramic or cross-section CBCT images. In most cases implant size measured in crosssection images was narrower and shorter than implant size measured in a panoramic image or CBCT-based panoramic view.
39

Reabsorções radiculares internas simuladas : desenvolvimento de nova metodologia com desmineralização ácida e análise volumétrica com diferentes protocolos de aquisição tomográfica / Development of a new in vitro methodology to simulate internal root resorption and influence of different tomographic protocols in the measurement volume

Silveira, Priscila Fernanda da January 2013 (has links)
Introdução: As reabsorções radiculares internas (RRI) são lesões de difícil prognóstico e o diagnóstico é baseado em exames clínicos e de imagem. Estudos que avaliam a acurácia dos exames por imagem para a detecção de RRI, utilizam simulações realizadas por brocas, criando cavidades com forma e limites definidos diferentes da realidade clínica. Além disso, sabe-se que tão importante quanto a detecção da lesão de RRI é a capacidade de visualização do envolvimento da estrutura dentinária adjacente. Assim, este trabalho objetivou desenvolver uma nova metodologia para simulação de RRI com base na desmineralização ácida e, após, testar a influência de diferentes protocolos de aquisição de imagens tomográficas na medição do volume dessas lesões. Materiais e métodos: Foi testada uma metodologia de simulação de RRI, com ação progressiva de ácido nítrico 5% e hipoclorito de sódio 8%, em onze dentes monorradiculares. As cavidades geradas foram avaliadas em Microscopia Eletrônica de Varredura (MEV) e as medidas de diâmetro e profundidade foram correlacionadas com os tempos de ação do ácido. Imagens de Tomografia Computadorizada de Feixe Cônico (TCFC) foram adquiridas de todos os dentes da amostra em dois aparelhos, de FOV amplo e restrito, com três protocolos de tamanho de voxel cada: I-Cat Next Generation (voxel 0,200; 0,250; 0,300 mm) e Kodak 9000 3D (voxel 0,076; 0,100; 0,200 mm). As simulações de RRI foram mensuradas com uma ferramenta de cálculo de volume do software Dolphin 3D. Os valores médios de volume das cavidades foram comparados com Análise de Variância (ANOVA) e Teste Tukey ( =0,05). A validação das mensurações de volume obtidas pelo software foi realizada por meio de moldagem das cavidades com silicona de adição. Resultados: As simulações de RRI reproduziram lesões de diferentes tamanhos e com profundidades de 0.22 mm a 1.59 mm. Em relação às medidas volumétricas, não houve diferença estatística significante (P<0,05) entre os volumes de RRI mensurados a partir dos dois menores tamanhos de voxel em cada aparelho de TCFC, mas ambos foram diferentes estatisticamente (P>0,05) do volume calculado com os maiores tamanhos de voxel. Ainda, as médias de volume a partir das impressões em silicona foram menores que as mensuradas pelo voxel 0,200 mm. Conclusão: A metodologia de simulação de RRI proposta gerou cavidades com limites irregulares e com razão de diâmetro:profundidade mais semelhante ao processo de RRI in vivo. Diferentes protocolos de TCFC influenciam nas medidas de volume de RRI simuladas, ressaltando a importância da padronização na aquisição das imagens para acompanhamento dessas lesões. / Introduction: The internal root resorption (IRR) injuries are difficult to predict and the diagnosis is based on clinical and radiographic examination. Studies that evaluated the accuracy of imaging tests for the detection of IRR using simulations produced by burs, created cavities with different forms and limits of clinical reality. Furthermore, it is known that as important as the IRR detection is the ability to preview the involvement of adjacent dentinal structure. Thus, this study aimed to develop a new methodology for IRR simulation-based with acid demineralization and after investigate the influence of different tomographic protocols in the measurement of the IRR lesions volume. Materials and methods: A methodology was desenvolved for simulation of IRR with progressive action of 5% nitric acid and 8% sodium hypochlorite in eleven teeth single-rooted. IRR cavities produced were evaluated by scanning electron microscopy (SEM), measured in diameter and depth and after correlated with the acid times. Cone Beam Computed Tomography (CBCT) images were acquired of all teeth in two tomography devices, with large and restrict field of view (FOV) using three voxel sizes protocols: I-Cat Next Generation (voxel 0.200, 0.250, 0.300 mm) and Kodak 9000 3D (voxel 0.076, 0.100, and 0.200 mm). IRR simulations were measured with a tool for calculating volume of the Dolphin 3D software. Volume means of the IRR cavities were compared using Analysis of Variance (ANOVA) and Tukey test ( = 0.05). A validation of the tomographic measurements was performed with addition silicone impression. Results: The simulations reproduced IRR lesions with different sizes and depths (0.22mm to 1.59mm). Regarding volumetric measurements, there was no statistically significant (P<0,05) difference between the IRR volumes measured from the two smaller voxel sizes in each CBCT device, but both were statistically different (P>0,05) from the calculated volume with larger voxel sizes. Still, the volume means from silicone impressions were lower than those measured at 0.200 mm voxel. Conclusion: The IRR simulation methodology generated cavities with irregular borders and diameter:depth ratio more similar to in vivo process of IRR. Different protocols of CBCT influences the volume measures of IRR simulated, emphasizing the importance of standardization in the acquisition of CBCT images for monitoring these lesions.
40

Detectabilidade e análise dimensional de falhas no revestimento polimérico de isoladores de compósitos por radiografia por radiografia computadorizada

Pino de Castro Júnior, Zurdival 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T17:36:54Z (GMT). No. of bitstreams: 2 arquivo2170_1.pdf: 9385671 bytes, checksum: d99af49ad226ec4cc20051209fb713b9 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Companhia Hidro Elétrica do São Francisco / Atualmente, as companhias elétricas do país e do exterior, visando detectar defeitos críticos nos isoladores de compósito, estão realizando inspeções das linhas viva remotamente, através de termovisão com câmera de infravermelho, detecção de emissão de UV do efeito corona, e inspeção visual. Embora a combinação desses métodos permita a detecção de defeitos nos revestimentos nem sempre a análise dos resultados é conclusiva. Ademais, quando os isoladores estão instalados no campo, paulatinamente ocorre acúmulo de poluentes nas aletas e no revestimento o que dificulta de sobremaneira as inspeções em condição energizada. Portanto, há necessidade urgente de se desenvolver uma técnica de inspeção que, mesmo na presença de camadas de poluentes no isolador, possa avaliar com eficiência se o isolador de compósito está ou não sob o risco de fraturar. Na presente dissertação foi realizada a avaliação da eficiência das técnicas de radiografia computadorizada em termos de detectabilidade e análise dimensional de falhas no revestimento polimérico do isolador de compósito, utilizando inclusive um sistema de radiografia computadorizado considerado de melhor resolução disponível na atualidade. Os resultados obtidos com dois sistemas de radiografia computadorizado foram comparados com os resultados obtidos com a técnica de radiografia convencional utilizando filmes de classes I e II e imagens radiográficas 2D obtidas com micro tomógrafo computadorizado. Ademais, um isolador de compósito que apresentou três pontos quentes, os quais foram detectados por termovisão no campo, foi analisado com um sistema de radiografia computadorizado no laboratório, visando uma correlação entre as imagens termográficas e as imagens radiográficas. Embora a resolução espacial do sistema de radiografia com filmes de classe-I tenha sido superior quando as imagens de IQI de fio duplo foram comparadas, em termos de detectabilidade de falhas, praticamente não houve diferença com os resultados obtidos pelos sistemas de radiografia computadorizadas. Por outro lado, quando os resultados em termos de detectabilidade de falhas, informações quanto a sua localização, profundidade, as imagens 2D de micro tomografia são insuperáveis. Com respeito às imagens termográficas, dois dos três pontos quentes parecem estar associados a falhas de fabricação

Page generated in 0.0782 seconds