• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • Tagged with
  • 7
  • 7
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Radioisotopic energy conversion system (RECS) a new radioisotopic power cell, based on nuclear, atomic, and radiation transport principles /

Steinfelds, Eric V. January 2003 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 2003. / Typescript. Vita. Includes bibliographical references (leaves 63-65). Also available on the Internet.
2

Radioisotopic energy conversion system (RECS) : a new radioisotopic power cell, based on nuclear, atomic, and radiation transport principles /

Steinfelds, Eric V. January 2003 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 2003. / Typescript. Vita. Includes bibliographical references (leaves 63-65). Also available on the Internet.
3

Development and optimization of W-188/Re-188 and Mo-99/Tc-99m gel radioisotope generators /

Liang, Qixue, January 1996 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 1996. / "m in ⁹⁹mTc on short title page is supercript." Typescript. Vita. Includes bibliographical references (leaves 131-136). Also available on the Internet.
4

Development and optimization of W-188/Re-188 and Mo-99/Tc-99m gel radioisotope generators

Liang, Qixue, January 1996 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 1996. / "M in ⁹⁹mTc on short title page is supercript." Typescript. Vita. Includes bibliographical references (leaves 131-136). Also available on the Internet.
5

Estudo de materiais adsorvedores para o preparo de geradores de Ge-68/Ga-68 / Studies of adsorber materials for preparing 68Ge/68Ga generators

Brambilla, Tânia de Paula 11 September 2013 (has links)
O 68Ga é um radionuclídeo promissor para a medicina nuclear, decaindo por emissão de pósitrons com abundância de 89%, apresentando tempo de meia vida física de 68 minutos, o que é compatível com a farmacocinética de muitas biomoléculas e substratos de baixo peso molecular. Outra característica importante é a sua disponibilidade por um sistema de gerador, onde o radionuclídeo pai, 68Ge (t1/2 = 270,95 dias) é adsorvido em uma coluna e o filho, 68Ga, é eluído na forma iônica 68Ga3+. O desenvolvimento dos geradores de 68Ge/68Ga teve início na década dos anos 60, mas o seu uso clínico começou a ser aceitável e relevante apenas recentemente. O método de separação do 68Ge do 68Ga mais utilizado é o sistema cromatográfico de troca iônica, devido sua praticidade de operação, mas outros sistemas de geradores já foram propostos, como de extração por solvente e técnica de evaporação. Atualmente, os geradores de 68Ge/68Ga são disponíveis comercialmente tanto com colunas utilizando matrizes inorgânicas preparadas com TiO2 ou SnO2 como também usando resina orgânica. A eficiência de eluição do 68Ga varia de 70 % a 80 %, apresentando uma queda ao longo do tempo. Os níveis de contaminação do 68Ge vão de 10-2 a 10-3 %, porém ocorre um aumento nos níveis de contaminação após longos períodos de uso. Mesmo com todos os avanços tecnológicos, ocorridos nas últimas décadas, no desenvolvimento dos geradores de 68Ge/68Ga, o eluato de 68Ga dos geradores comerciais ainda não é adequado para uso direto em seres humanos e algumas melhorias nos sistemas precisam ser feitas para diminuir os níveis de contaminação de 68Ge e impurezas químicas. O objetivo principal deste trabalho foi desenvolver um sistema de gerador de 68Ge/68Ga com o qual se pudesse eluir o 68Ga com qualidade necessária para uso clínico. O comportamento químico do Ge e do Ga foi avaliado em vários materiais adsorvedores inorgânicos. Foram desenvolvidos dois tipos de sistemas de geradores de 68Ge/68Ga utilizando o TiO2 como material adsorvedor: sistema de eluição com pressão manual e sistema de eluição a vácuo, controlado. As eficiências dos geradores foram similares às encontradas nos geradores comerciais, assim como os níveis de impurezas no eluato. Um novo método para o controle radionuclídico foi desenvolvido e apresentou resultados satisfatórios para determinação da contaminação do 68Ge no eluato do gerador. Foi proposto um protótipo de gerador capaz de fornecer 68Ga com a qualidade necessária para ser utilizado em aplicações médicas. / The 68Ga is a promising radionuclide for nuclear medicine, decaying by positron emission with an abundance of 89%, with physical half-life of 68 minutes, which is compatible with the pharmacokinetics of many biomolecules and low molecular weight substrates. Another important feature is its availability through a generator system, where the parent radionuclide, 68Ge (t1/2 = 270.95 days) is adsorbed on a column and the daughter, 68Ga, is eluted in an ionic form 68Ga3+. The development of 68Ge/68Ga generators began in the 60s, but its clinical use began to be acceptable and relevant only recently. The method of separation of 68Ge and 68Ga most used is the ion-exchange chromatographic system, due to its practical operation, but other generator systems have been proposed, such as solvent extraction and evaporation technique. Currently, 68Ge/68Ga generators are commercially available using inorganic matrices columns prepared with TiO2 or SnO2 as well using organic resin. The efficiency of 68Ga elution ranges from 70% to 80%, decreasing over time. The 68Ge breakthrough varies from 10-2 to10-3 % or lower in a fresh generator, but there is an increase in the levels of contamination after long periods of use. Even with all the technological advances in the development of 68Ge/68Ga generators in the past decades, the 68Ga eluted from commercial generators is not suitable for direct use in humans and some improvements in the systems need to be made to reduce the 68Ge breakthrough and chemical impurities levels. The main objective of this work was to develop a 68Ge/68Ga generator system is which 68Ga could be eluted with quality required for clinical use. The chemical behavior of Ge and Ga was evaluated on various inorganic adsorbents materials. Two types of 68Ge/68Ga generator systems were developed using TiO2 as adsorbent material: elution system with manual pressure and vacuum controlled. The efficiencies of the generators were similar to those found in commercial generators, as well as the impurity levels in the eluate. A new method for radionuclidic control was developed and showed good results for the determination of 68Ge breakthrough in 68Ga eluate. It was proposed a prototype 68Ga generator capable of providing the quality needed for use in medical applications.
6

Evaluation and redesign of radiation shielding in a radionuclide production facility at a particle accelerator / Onalenna Kegopotsemang

Kegopotsemang, Onalenna January 2004 (has links)
iThemba LABS is a particle accelerator facility housing a radionuclide production facility that uses a 66 MeV proton beam to produce radionuclides for medical and industrial use. Ionising radiation is produced by a variety of sources at Themba LABS. Ionising is a health hazard. High doses can cause acute radiation syndrome, i.e. "radiation sickness". Lower doses cannot cause acute symptom, but carry a risk of radiation-related cancer. Ionising radiation is also detrimental to materials, and can damage polymers and lubricants e.g. Shielding is used to reduce radiation levels to values that should be safe for the intended level of human occupancy. Shield performance is vital to human health and the life expectancy of polymers and lubricants, so that quality management in shield design is very important. However, until 2003, there has been no formal system at iThemba LABS to evaluate and improve all radiation shield designs and layouts from a radiation protection perspective. This study deals with evaluating and redesigning radiation shielding in the radionuclide production facility of iThemba LABS. There are several designs and layouts in the radionuclide production building of iThemba LABS that lead to unnecessary exposure of personnel to ionising radiation. The shielding in these areas are sub-standard. Performance criteria for radiation shields are developed. Inadequate radiation shields are identified. The identified inadequate shields are: the processing hotcells, the target store room and the hotcells in the radiopharmaceutical dispensing laboratory, Point-Kernel radiation shielding calculations are done to specify materials and material thickness that will adequately protect workers against ionising radiation. / Thesis (MSc. ARST) North-West University, Mafikeng Campus, 2004
7

Estudo de materiais adsorvedores para o preparo de geradores de Ge-68/Ga-68 / Studies of adsorber materials for preparing 68Ge/68Ga generators

Tânia de Paula Brambilla 11 September 2013 (has links)
O 68Ga é um radionuclídeo promissor para a medicina nuclear, decaindo por emissão de pósitrons com abundância de 89%, apresentando tempo de meia vida física de 68 minutos, o que é compatível com a farmacocinética de muitas biomoléculas e substratos de baixo peso molecular. Outra característica importante é a sua disponibilidade por um sistema de gerador, onde o radionuclídeo pai, 68Ge (t1/2 = 270,95 dias) é adsorvido em uma coluna e o filho, 68Ga, é eluído na forma iônica 68Ga3+. O desenvolvimento dos geradores de 68Ge/68Ga teve início na década dos anos 60, mas o seu uso clínico começou a ser aceitável e relevante apenas recentemente. O método de separação do 68Ge do 68Ga mais utilizado é o sistema cromatográfico de troca iônica, devido sua praticidade de operação, mas outros sistemas de geradores já foram propostos, como de extração por solvente e técnica de evaporação. Atualmente, os geradores de 68Ge/68Ga são disponíveis comercialmente tanto com colunas utilizando matrizes inorgânicas preparadas com TiO2 ou SnO2 como também usando resina orgânica. A eficiência de eluição do 68Ga varia de 70 % a 80 %, apresentando uma queda ao longo do tempo. Os níveis de contaminação do 68Ge vão de 10-2 a 10-3 %, porém ocorre um aumento nos níveis de contaminação após longos períodos de uso. Mesmo com todos os avanços tecnológicos, ocorridos nas últimas décadas, no desenvolvimento dos geradores de 68Ge/68Ga, o eluato de 68Ga dos geradores comerciais ainda não é adequado para uso direto em seres humanos e algumas melhorias nos sistemas precisam ser feitas para diminuir os níveis de contaminação de 68Ge e impurezas químicas. O objetivo principal deste trabalho foi desenvolver um sistema de gerador de 68Ge/68Ga com o qual se pudesse eluir o 68Ga com qualidade necessária para uso clínico. O comportamento químico do Ge e do Ga foi avaliado em vários materiais adsorvedores inorgânicos. Foram desenvolvidos dois tipos de sistemas de geradores de 68Ge/68Ga utilizando o TiO2 como material adsorvedor: sistema de eluição com pressão manual e sistema de eluição a vácuo, controlado. As eficiências dos geradores foram similares às encontradas nos geradores comerciais, assim como os níveis de impurezas no eluato. Um novo método para o controle radionuclídico foi desenvolvido e apresentou resultados satisfatórios para determinação da contaminação do 68Ge no eluato do gerador. Foi proposto um protótipo de gerador capaz de fornecer 68Ga com a qualidade necessária para ser utilizado em aplicações médicas. / The 68Ga is a promising radionuclide for nuclear medicine, decaying by positron emission with an abundance of 89%, with physical half-life of 68 minutes, which is compatible with the pharmacokinetics of many biomolecules and low molecular weight substrates. Another important feature is its availability through a generator system, where the parent radionuclide, 68Ge (t1/2 = 270.95 days) is adsorbed on a column and the daughter, 68Ga, is eluted in an ionic form 68Ga3+. The development of 68Ge/68Ga generators began in the 60s, but its clinical use began to be acceptable and relevant only recently. The method of separation of 68Ge and 68Ga most used is the ion-exchange chromatographic system, due to its practical operation, but other generator systems have been proposed, such as solvent extraction and evaporation technique. Currently, 68Ge/68Ga generators are commercially available using inorganic matrices columns prepared with TiO2 or SnO2 as well using organic resin. The efficiency of 68Ga elution ranges from 70% to 80%, decreasing over time. The 68Ge breakthrough varies from 10-2 to10-3 % or lower in a fresh generator, but there is an increase in the levels of contamination after long periods of use. Even with all the technological advances in the development of 68Ge/68Ga generators in the past decades, the 68Ga eluted from commercial generators is not suitable for direct use in humans and some improvements in the systems need to be made to reduce the 68Ge breakthrough and chemical impurities levels. The main objective of this work was to develop a 68Ge/68Ga generator system is which 68Ga could be eluted with quality required for clinical use. The chemical behavior of Ge and Ga was evaluated on various inorganic adsorbents materials. Two types of 68Ge/68Ga generator systems were developed using TiO2 as adsorbent material: elution system with manual pressure and vacuum controlled. The efficiencies of the generators were similar to those found in commercial generators, as well as the impurity levels in the eluate. A new method for radionuclidic control was developed and showed good results for the determination of 68Ge breakthrough in 68Ga eluate. It was proposed a prototype 68Ga generator capable of providing the quality needed for use in medical applications.

Page generated in 0.1129 seconds