• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Physical parameters of very small diameter 10 MV x-ray beams for linac-based stereotactic radiosurgery

Sham, Edwin. January 2008 (has links)
No description available.
2

Spinal radiation oncology using a conventional linear accelerator with add-on multileaf collimator and image-guided patient positioning system. / 常規直線加速器附加多葉準直器及影像導引病人定位系統於脊椎放射腫瘤學之應用 / CUHK electronic theses & dissertations collection / Chang gui zhi xian jia su qi fu jia duo ye zhun zhi qi ji ying xiang dao yin bing ren ding wei xi tong yu ji zhui fang she zhong liu xue zhi ying yong

January 2013 (has links)
Ngar, Yuen Kan. / Thesis (Ph.D.)--Chinese University of Hong Kong, 2013. / Includes bibliographical references (leaves 157-159). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstract also in Chinese.
3

Dosimetric evaluation of four techniques used in stereotactic radiosurgery

Charpentier, Pierre E. January 2007 (has links)
The thesis presents a comparison of four techniques used for stereotactic radiosurgery, consisting of the static conformal beam, static cone-based, proton therapy, and the Gamma Knife techniques. The comparisons involved six test cases in which phantom target lesions were created in the center of the modified anthropomorphic RandoRTM head. The phantom lesions presented in the study were extreme irregular cases that ranged in shape and volume and were near a critical structure to receive minimal dose during treatment planning. The best treatment plans from each technique for all studies were selected and the extracted data was analyzed using physical and biological parameters. Correlations between integral biological effective dose (normal brain) and normal tissue complication probability were analyzed as a function of dose conformity (PITV), and correlations between tumor control probability and integral biological effective dose (tumor) as a function of dose homogeneity (MDPD) were analyzed, as well. These parameter pairings showed strong links. The static conformal beam and the proton SOBP techniques consistently provided low PITV and MDPD values for all cases, including the most irregular and complicated cases. Higher PITV and MDPD values, typically associated with static cone-based and the Gamma Knife techniques, were due to normal tissue and tumor tissue, respectively, being irradiated at higher dose levels than the prescribed dose. For these cases, as the PITV increased, the NTCP increased, as well, due to high doses created within the normal tissue found within the prescription isodose surface.
4

Dosimetric evaluation of four techniques used in stereotactic radiosurgery

Charpentier, Pierre E. January 2007 (has links)
No description available.

Page generated in 0.0941 seconds