Implementation of radiation film dosimetry system to be used for the verification of a 3-D electron pencil-beam algorithm on a radiation treatment planning system

Jones, Quyen L. 11 June 2004 (has links)
Radiation film dosimetry process using the RIT 113 v.4 dosimetry software and the film digitizer VXR-l2plus was used to evaluate the accuracy of electron dose calculations of the RAHD radiation therapy treatment planning system at Samaritan Regional Cancer Center. Kodak Ready-Pack EDR-2 film is recommended for dose distribution analysis in clinically practical dose ranges. The pencil-beam algorithm has a limitation for calculating dose in the penumbra region and in the tail region where the dose falls off. / Graduation date: 2005
2

An Investigation into EPID Flood Fields Independent from the Linear Accelerator Beam

Satory, Philip Reynard January 2008 (has links)
The EPID (electronic portal imaging device) was designed for in vivo imaging of patients during radiotherapy treatment. The ability of EPIDs to promptly acquire two dimensional data, lends them to be considered for use in quality assurance of the linac. This thesis set out to investigate the possibility of using a radionuclide, technetium 99 m (Tc99m), to produce a flood field for the calibration of an EPID, because using a beam calibrated EPID to measure the beam is self-referential. The difference in relative response between the energy spectrum of a 6MV beam and the Tc99m was investigated using EGSNRC DoseXYZ Monte Carlo Modelling. The relative output ratio was calculated to be less than 1.6%. The dose response of the EPID with respect to dose rate was checked using different activities of Tc99m and found to be linear. The flatness from a phantom was calculated, with a model in MATLAB, for a range of heights, overlaps, thickness, and deformations, to find the optimum balances between signal strength and flatness. This model was checked for accuracy using diagnostic radiographic film. The culmination of the energy response, linearity and the calculated flatness is a flood field taken with a flood phantom on the EPID with low signal strength. To get a signal to noise ratio of 3% the mean of over 2000 flood field images were used. This accuracy was not adequate for clinical use but the averaging of pixels it is accurate enough for QA.
3

An Investigation into EPID Flood Fields Independent from the Linear Accelerator Beam

Satory, Philip Reynard January 2008 (has links)
The EPID (electronic portal imaging device) was designed for in vivo imaging of patients during radiotherapy treatment. The ability of EPIDs to promptly acquire two dimensional data, lends them to be considered for use in quality assurance of the linac. This thesis set out to investigate the possibility of using a radionuclide, technetium 99 m (Tc99m), to produce a flood field for the calibration of an EPID, because using a beam calibrated EPID to measure the beam is self-referential. The difference in relative response between the energy spectrum of a 6MV beam and the Tc99m was investigated using EGSNRC DoseXYZ Monte Carlo Modelling. The relative output ratio was calculated to be less than 1.6%. The dose response of the EPID with respect to dose rate was checked using different activities of Tc99m and found to be linear. The flatness from a phantom was calculated, with a model in MATLAB, for a range of heights, overlaps, thickness, and deformations, to find the optimum balances between signal strength and flatness. This model was checked for accuracy using diagnostic radiographic film. The culmination of the energy response, linearity and the calculated flatness is a flood field taken with a flood phantom on the EPID with low signal strength. To get a signal to noise ratio of 3% the mean of over 2000 flood field images were used. This accuracy was not adequate for clinical use but the averaging of pixels it is accurate enough for QA.