• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Espalhamento Thomson no toróide compacto TC-1

Berni, Luiz Angelo 29 August 1996 (has links)
Orientador: Munemasa Machida / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-21T20:00:36Z (GMT). No. of bitstreams: 1 Berni_LuizAngelo_D.pdf: 7474857 bytes, checksum: e352b50bbf0c05d94872b68f36f6467c (MD5) Previous issue date: 1996 / Resumo: Pela primeira vez foi instalado o diagnóstico de espalhamento Thomson no Toróide Compacto TC-1 da Unicamp. Primeiramente o diagnóstico foi realizado com uma única passagem do laser de rubi ( energia: 3 J -duração: 40 ns ) pelo plasma com injeção axial e radial do laser e observado a 90° .Com a injeção axial obtivemos uma densidade de (4,3 ± 0,7)x1021 m-3 e uma temperatura eletrônica de ( 8 ± 3) eV. Estes resultados foram confirmados com a geometria radial de injeção do laser com uma densidade de (5 ± 1)x1021 m-3 e uma temperatura de (5 ± 2) eV. A principal dificuldade neste tipo de experimento é a baixa razão entre a potência espalhada pelo plasma e a potência incidente do laser, que para um plasma típico de theta-pinch fica em torno de 10-12 .Para aumentar esta relação dois novos métodos foram estudados e aplicados no TC-1. O primeiro método que foi desenvolvido na Rússia consiste em fazer a luz do laser refletir várias vezes entre dois espelhos esféricos passando pela mesma região no plasma, aumentando desta forma o sinal espalhado. Com este método obtivemos um aumento do sinal de 5 vezes para 6 passagens do laser pelo plasma. Depois de algumas mudanças realizadas no TC-1 para aumentar a temperatura do plasma, conseguimos com o espalhamento Thomson multipasso uma temperatura de (24 ± 8) eV e uma densidade de (5,0 ± 0,8)x1021 m-3. O segundo método chamado de espalhamento Thomson em ângulo baixo, foi desenvolvido pela equipe do laboratório de Plasmas da Unicamp. Este método leva em consideração o fato de que para ângulos de observação menores de 90° a intensidade do espectro espalhado aumenta. Realizamos as medidas em um ângulo de 21° e através de um programa especialmente desenvolvido obtivemos uma temperatura de (15 ± 6) eV e uma densidade de (9 ± 2)x1021 m-3 que foram confirmados com espalhamento Thomson a 90°. Sendo que o nível de luz espúria do sistema ( do inglês "stray light" ) sempre foi mantida em níveis aceitáveis, a calibração do sistema foi realizada por espalhamento molecular Rayleigh com gás nitrogênio. Estes resultados de alta densidade e baixa temperatura que provavelmente são devidos a presença de impurezas no sistema, também foram confirmados pela espectroscopia V. U .V. e interferometria com CO2 instalados por outros membros da equipe / Abstract: For the first time, the 90° Thomson scattering diagnostic in the Compact Torus TC-1 at UNICAMP has been instaled. Firstly, this diagnostic has been done with traditional one pass of the rubi laser light ( energy : 3 J -duration : 40 ns ) through the plasma with axial and radial laser injection. By axial injection a density of (4.3 ± O.7)x1021 m-3 and a electronic temperature of ( 8 ± 3) eV was obtained . These results were confirmed with the radial geometry injection of the laser ( ne = (5 ± 1)x1021 m-3, Te = 5 ± 2 eV ). The main dificulty in this kind of experiment is the low ratio between the scattered power from the plasma and the incident laser power, which for a tipical theta-pinch plasma is about 10-12. To increase this relation, two new methods were studied and applied to the TC-1 device. The first method , developed recently in Russia, forces the laser light to pass several times in the same scattering region of the plasma through reflections in two spherical mirrors, increasing therefore the scattered light. An increase of 5 times was obtained with 6 passes of the laser through the plasma. After carrying out some changes in the TC-1 system, in order to increase the plasma temperature, the multipass Thomson scattering measurements were performed. With this method a temperature of (24 ± 8) eV and a density of (5.0 ± 0.8)x1021 m-3 were measured. The second method, the low angle Thomson scattering, was developed by the UNICAMP's plasma laboratory group. This method takes into account the fact that for observation angles less than 90° the scattered light increases. Our experiment has been carried out at 21° and the plasma parameters were calculated by using a specially developed code. A density of (9 ± 2 )x1021 m-3 and a temperature of (15 ± 6) eV were measured and confirmed by a single pass 90° Thomson scattering. As the stray light of the system has been kept to acceptable low levels, the calibration of the signals has been done by molecular Rayleigh scattering using nitrogen gas. These high density and low temperature results, that are probably due to the impurities in the system, were confirmed by V.U.V. spectroscopy and CO2 interferometry instaled by other members of the grou / Doutorado / Física / Doutor em Ciências
2

Equipamento para teste de desempenho de receptores celulares utilizando emulação de desvanecimento plano

Angulo Butron, Jose Boris 03 August 2018 (has links)
Orientador: Evandro Conforti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-03T17:27:13Z (GMT). No. of bitstreams: 1 AnguloButron_JoseBoris_M.pdf: 3718604 bytes, checksum: 3c919d32bad48bb481ab0a8daa87bc5e (MD5) Previous issue date: 2003 / Mestrado
3

Aumento da taxa para um esquema de cooperação e probabilidade de erro para detector 'lâmbda'-MRC em canal rayleigh / Data rate increase for cooperation scheme and error probability for the 'lâmbda' -MRC detector under rayleigh channel

Calderon Inga, Mitchell Omar 18 August 2018 (has links)
Orientador: Gustavo Fraidenraich / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-18T12:42:39Z (GMT). No. of bitstreams: 1 CalderonInga_MitchellOmar_M.pdf: 4733718 bytes, checksum: 3e71582f5976b8ea4eeca1018833957d (MD5) Previous issue date: 2011 / Resumo: Neste trabalho, propomos um esquema novo baseado na diversidade por cooperação de usuários. Os resultados apresentados mostram que o novo esquema de cooperação consegue um aumento substancial da taxa de dados, mantendo a média da probabilidade de erro de bit perto dos valores obtidos no artigo User Cooperation Diversity-Part II escrito por Sendonaris et al. Em particular, apresentamos uma análise de desempenho usando uma implementação CDMA (code division multiple access) convencional para dois usuários. Além disso, uma expressão exata para a probabilidade média de erro de bit foi obtida para o detector ?-MRC (maximal-ratio combining), proposto por Sendonaris et al., para um canal com desvanecimento Rayleigh. Dada a complexidade da expressão exata, uma aproximação muito boa foi obtida para calcular a probabilidade média de erro de bit para qualquer esquema de alocação de potência. Nossas expressões permitem investigar os possíveis ganhos e as situações onde a cooperação pode ser benéfica / Abstract: In this work, we propose a new scheme based on user cooperation diversity. The results presented here show that the new scheme of cooperation achieves substantial increase of data rate, keeping the average bit error probability close to values obtained in the paper User Cooperation Diversity-Part II written by Sendonaris et al. In particular, we present performance analysis using conventional CDMA (code division multiple access) implementation for two users. Moreover, an exact expression for the average bit error probability was obtained for the ?-MRC (maximal-ratio combining) detector, proposed in Sendonaris et al., under Rayleigh fading channel. Given the complexity of the exact expression, a very good approximation was obtained to calculate the average bit error probability for any power allocation scheme. Our expressions allow to investigate the possible gains and situations where cooperation can be beneficial / Mestrado / Telecomunicações e Telemática / Mestre em Engenharia Elétrica

Page generated in 0.0949 seconds