Estratégia de partida para a granulação aeróbia em reator em bateladas sequenciais tratando esgoto doméstico diluídoARAÚJO, Julliana Melo Pinheiro de 15 February 2016 (has links)
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2016-07-07T18:40:49Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação Julliana Melo - Times.pdf: 2376859 bytes, checksum: d48b49e600f24789b26dc66a89f1f59e (MD5) / Made available in DSpace on 2016-07-07T18:40:49Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação Julliana Melo - Times.pdf: 2376859 bytes, checksum: d48b49e600f24789b26dc66a89f1f59e (MD5)
Previous issue date: 2016-02-15 / A granulação aeróbia surge como melhoria ao sistema de lodos ativados convencional, aumentando a retenção de biomassa no sistema e possibilitando a remoção simultânea de nutrientes e matéria orgânica. No entanto, são poucos os trabalhos que utilizam esgoto sanitário em escala piloto. O presente trabalho tem como objetivo investigar a influência de diferentes trocas volumétricas em reatores em bateladas sequenciais (RBS’s) como condição operacional para o desenvolvimento de grânulos aeróbios no tratamento de esgoto doméstico diluído. Considerando que o processo de granulação aeróbia ocorre sob condições operacionais específicas, foi utilizada como estratégia metodológica dois RBS’s com diferentes trocas volumétricas, RBS1 de 59% e RBS2 de 71%. Também utilizou-se velocidade de aeração entre 1,2 e 1,4 cm.s-1, relação altura diâmetro de 10, e tempo de sedimentação final entre 10 e 15 minutos, para ambos os reatores. Foram observadas oscilações no comportamento dos sólidos suspensos e redução da retenção celular associadas ao curto tempo de sedimentação. A observação de grânulos aeróbios foi possível após 71 dias de operação para o RBS1 e 91 dias de operação para o RBS2. Percebeu-se a estabilização da idade do lodo em aproximadamente 6,3 dias no RBS1 e, no RBS2, valores próximos a 1 dia, indicando a menor retenção de biomassa neste reator. Em termos de eficiência de remoção de DQOs, DQOt, NH4+ e NTK, a troca volumétrica de 59% (RBS1) apresentou resultado de 72 ± 10%, 65 ± 21%, 48 ± 29% e 50 ± 34%, respectivamente, enquanto a troca de 71% (RBS2) apresentou 65 ± 12%, 58 ± 21%, 28 ± 26% e 30 ± 24%, respectivamente. Devido a não maturação dos grânulos, e a consequente ausência de microzonas anaeróbias, não foi observada remoção de fósforo em ambos os reatores. Ao final deste trabalho, verificou-se a viabilidade do processo de granulação utilizando esgoto doméstico diluído como substrato sem a presença de inóculo. Também foi possível verificar que com a utilização de troca volumétrica menor este processo é qualitativamente melhor, apresentando granulação mais rápida, presença de lodo com melhor sedimentabilidade e maior remoção de NH4+ e NTK. / Aerobic granulation could to improve the conventional activated sludge system increasing the biomass retention in the system and enabling the simultaneous removal of organic matter and nutrients. However, few research has been reported using domestic wastewater in pilot scale. This study aims to investigate the influence of different volumetric changes in sequencing batch reactors (SBR's) as operating condition for development of aerobic granules in treatment of diluted domestic wastewater. Whereas aerobic granulation process occurs under specific operating conditions, then as a methodological strategy were used two SBRs with different volumetric changes, SBR1 59% and SBR2 71%. Aeration rate of 1.2 to 1.4 cm.s-1, ratio of height: diameter of 10 and the final sedimentation time between 10 and 15 minutes for both reactors were used as parameters. During the experiment if was possible to observe fluctuations in the behavior of the suspended solids and reduction of cell retention associated to sedimentation short time. The observation of aerobic granules was possible after 71 days of operation for SBR1 and 91 days to SBR2. The sludge age stabilized at approximately 6.3 days in the SBR1 and 1 day to SBR2, indicating the lowest retaining biomass in this reactor. In terms of CODs, CODt, NH4+ and NTK removal efficiency, the volumetric exchange of 59% (SBR1) showed results of 72 ± 10%, 65 ± 21%, 48 ± 29% and 50 ± 34%, respectively, while the volumetric exchange of 71% (SBR2) showed results 65 ± 12%, 58 ± 21%, 28% ± 26 and 30 ± 24%, respectively. Due to the non-maturation of granules and the consequent lack of anaerobic micro-zones, phosphorus removal was not observed in both reactors. The end of this study found the viability of the granulation process using domestic wastewater diluted as a substrate without the presence of inoculum. This study also observed that using lower volumetric exchange this process is qualitatively better, with faster granulation, better sludge settleability and increase in nitrogen removal.
|
2 |
Efeito da aeração e do tempo de ciclo na remoção biológica de nitrogênio de efluente da indústria avícola / Effect of aeration and cycle time in biological nitrogen removal of wastewater from poultry slaughterhouseLopes, Carla Limberger 01 July 2011 (has links)
Made available in DSpace on 2017-07-10T19:24:51Z (GMT). No. of bitstreams: 1
Carla Limberger Lopes_protegido.pdf: 1510356 bytes, checksum: 558cae02592904f9e836e71f9aa4036f (MD5)
Previous issue date: 2011-07-01 / This study aimed to evaluate the influence of air flow (0.25, 0.50 and 0.75 L.min-1.Lreator-1) and cycle time (11.35 h, 15.15 h and 18.25 h) in the performance of a sequencing batch reactor (SBR) to promote nitrification and denitrification of wastewater from slaughterhouse's poultry and refrigerator. The operation included the steps of feeding, aerobic and anoxic reaction, sedimentation, discharge and rest. SBR was operated on a laboratory scale with a working volume of 4 L, keeping 25% of biomass retained in the reactor as an inoculum for the next batch. The "manipueira" was added as a carbon source at the beginning of anoxic phase in order to keep the C: N ratio between 5 and 6. During this process, parameters monitored included: pH, alkalinity, dissolved oxygen and temperature. It was developed a factorial design (22) with five repetitions at the central point to check the influence of the response variable removal of total inorganic nitrogen (NH4+-N + NO2--N + NO3--N) in the whole process (%). Data were analyzed with 95% confidence, and experimentally, a higher removal of total inorganic nitrogen (85.75%) on average was observed when using air flow of 0.50 L.min-1.Lreator-1 in time cycle of 15.15 h. However, there was no statistically significant factor for the air flow, and during the progress of study, this variable was kept stable at 0.25 L.min-1.Lreator-1 while the cycle time was gradually increased until efficiency in the removal of constant nitrogen could be observed, which occurred at time 15.1 h with 92.78% in removal efficiency of total inorganic nitrogen. / Esta pesquisa teve por objetivo avaliar a influência da vazão de ar (0,25, 0,50 e 0,75 L.min-1.Lreator-1) e do tempo de ciclo (11,35 h, 15,15 h e 18,25 h) no desempenho de um reator em bateladas sequenciais (RBS), em promover a nitrificação e a desnitrificação de água residuária de abatedouro e frigorífico de aves. A operação contemplou as etapas de alimentação, reação aerada e anóxica, sedimentação, descarte e repouso. O RBS foi operado em escala de laboratório com volume útil de 4 L, mantendo-se 25% da biomassa no reator, como inóculo para a próxima batelada. A manipueira foi adicionada como fonte de carbono no início da fase anóxica, de modo a manter a relação C:N entre 5 e 6. Durante o processo foram monitorados os parâmetros pH, alcalinidade, oxigênio dissolvido e temperatura. Elaborou-se um planejamento fatorial (22) com cinco repetições no ponto central para verificar a influência dos fatores na variável resposta remoção de nitrogênio inorgânico total (N-NH4++N-NO2-+N-NO3-) no processo completo (%). Os dados foram analisados com 95% de confiança e, experimentalmente, a maior remoção de nitrogênio inorgânico total (85,75%) em média foi observada quando se utilizou vazão ar de 0,50 L.min-1.Lreator-1, no tempo de ciclo de 15,15 h. Entretanto, não foi verificada significância estatística para o fator vazão de ar e, na continuidade do estudo, esta variável foi mantida estável em 0,25 L.min-1.Lreator-1, enquanto o tempo de ciclo foi gradativamente elevado até ser observada eficiência de remoção de nitrogênio constante, o que foi verificado a partir do tempo de 15,1 h com 92,78% na eficiência de remoção de nitrogênio inorgânico total.
|
3 |
Efeito da aeração e do tempo de ciclo na remoção biológica de nitrogênio de efluente da indústria avícola / Effect of aeration and cycle time in biological nitrogen removal of wastewater from poultry slaughterhouseLopes, Carla Limberger 01 July 2011 (has links)
Made available in DSpace on 2017-05-12T14:48:14Z (GMT). No. of bitstreams: 1
Carla Limberger Lopes_protegido.pdf: 1510356 bytes, checksum: 558cae02592904f9e836e71f9aa4036f (MD5)
Previous issue date: 2011-07-01 / This study aimed to evaluate the influence of air flow (0.25, 0.50 and 0.75 L.min-1.Lreator-1) and cycle time (11.35 h, 15.15 h and 18.25 h) in the performance of a sequencing batch reactor (SBR) to promote nitrification and denitrification of wastewater from slaughterhouse's poultry and refrigerator. The operation included the steps of feeding, aerobic and anoxic reaction, sedimentation, discharge and rest. SBR was operated on a laboratory scale with a working volume of 4 L, keeping 25% of biomass retained in the reactor as an inoculum for the next batch. The "manipueira" was added as a carbon source at the beginning of anoxic phase in order to keep the C: N ratio between 5 and 6. During this process, parameters monitored included: pH, alkalinity, dissolved oxygen and temperature. It was developed a factorial design (22) with five repetitions at the central point to check the influence of the response variable removal of total inorganic nitrogen (NH4+-N + NO2--N + NO3--N) in the whole process (%). Data were analyzed with 95% confidence, and experimentally, a higher removal of total inorganic nitrogen (85.75%) on average was observed when using air flow of 0.50 L.min-1.Lreator-1 in time cycle of 15.15 h. However, there was no statistically significant factor for the air flow, and during the progress of study, this variable was kept stable at 0.25 L.min-1.Lreator-1 while the cycle time was gradually increased until efficiency in the removal of constant nitrogen could be observed, which occurred at time 15.1 h with 92.78% in removal efficiency of total inorganic nitrogen. / Esta pesquisa teve por objetivo avaliar a influência da vazão de ar (0,25, 0,50 e 0,75 L.min-1.Lreator-1) e do tempo de ciclo (11,35 h, 15,15 h e 18,25 h) no desempenho de um reator em bateladas sequenciais (RBS), em promover a nitrificação e a desnitrificação de água residuária de abatedouro e frigorífico de aves. A operação contemplou as etapas de alimentação, reação aerada e anóxica, sedimentação, descarte e repouso. O RBS foi operado em escala de laboratório com volume útil de 4 L, mantendo-se 25% da biomassa no reator, como inóculo para a próxima batelada. A manipueira foi adicionada como fonte de carbono no início da fase anóxica, de modo a manter a relação C:N entre 5 e 6. Durante o processo foram monitorados os parâmetros pH, alcalinidade, oxigênio dissolvido e temperatura. Elaborou-se um planejamento fatorial (22) com cinco repetições no ponto central para verificar a influência dos fatores na variável resposta remoção de nitrogênio inorgânico total (N-NH4++N-NO2-+N-NO3-) no processo completo (%). Os dados foram analisados com 95% de confiança e, experimentalmente, a maior remoção de nitrogênio inorgânico total (85,75%) em média foi observada quando se utilizou vazão ar de 0,50 L.min-1.Lreator-1, no tempo de ciclo de 15,15 h. Entretanto, não foi verificada significância estatística para o fator vazão de ar e, na continuidade do estudo, esta variável foi mantida estável em 0,25 L.min-1.Lreator-1, enquanto o tempo de ciclo foi gradativamente elevado até ser observada eficiência de remoção de nitrogênio constante, o que foi verificado a partir do tempo de 15,1 h com 92,78% na eficiência de remoção de nitrogênio inorgânico total.
|