• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utilização de reatores aeróbios como pós-tratamento de lixiviado antigo tratado por lagoas de estabilização / Use of aerobic reactors as post-treatment of leachate by old treaty stabilization ponds

Farias Filho, Antonio Lima 03 August 2010 (has links)
FARIAS FILHO, A. L. Utilização de reatores aeróbios como pós-tratamento de lixiviado antigo tratado por lagoas de estabilização. 2010. 84 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2010. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-04-22T13:55:44Z No. of bitstreams: 1 2010_dis_alfariasfilho.pdf: 1242877 bytes, checksum: 070051f4c3080bfb2c9c020a546f6e6f (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-04-22T17:11:46Z (GMT) No. of bitstreams: 1 2010_dis_alfariasfilho.pdf: 1242877 bytes, checksum: 070051f4c3080bfb2c9c020a546f6e6f (MD5) / Made available in DSpace on 2016-04-22T17:11:46Z (GMT). No. of bitstreams: 1 2010_dis_alfariasfilho.pdf: 1242877 bytes, checksum: 070051f4c3080bfb2c9c020a546f6e6f (MD5) Previous issue date: 2010-08-03 / The system of stabilization ponds, which is often present in landfills, is usually not efficient to meet environmental standards for disposal of treated leachate on surface waters. This study evaluated the use of submerged aerated reactor (SAR) and sequencing batch reactor (SBR) as post-treatment options for old leachate pre-treated in waste stabilization ponds. The leachate collection took place at the outflow of the last stabilization pond of the treatment system (two anaerobic em series, followed by a facultative pond) located in West Metropolitan Landfill (ASMOC), Caucaia municipality, metropolitan region of Fortaleza, Ceará state. A physical-chemical characterization of the leachate effluent was performed to verify the compliance to reach disposal standards. The SAR was operated in five phases, being divided between synthetic wastewater and leachate, the latter tested with and without dilution. We evaluated the effect of adding an external carbon source, ethanol, for the phase in which the reactor was fed with leachate without dilution. SBR was made of acrylic, in a cylindrical shape with a working volume of 5.0 L and the total time cycle of 24 hours was initially studied. The total time cycles of 12 and 48 hours were also evaluated in the SBR performance, as well as the effect of adding ethanol as carbon source. The reactors were installed at the Laboratory of Sanitation (Labosan) of the Department of Hydraulic and Environmental Engineering (DEHA), Federal University of Ceará (UFC). They were operated in the mesophilic range, with temperature near 27 ° C. Regarding the treated leachate, the physical-chemical characterization confirmed its recalcitrance and complexity, indicating that only the stabilization ponds did not fully meet the standards of disposal. The presence of recalcitrant and toxic compounds in the leachate influent to the SAR during the investigation period decreased COD removal, showing an inhibitory effect on the microorganisms present in the inoculum. However, in another research phase, both the SAR and SBR were stable and efficient on COD and ammonia removals, even when undiluted leachate was used. The addition of ethanol as external carbon source was beneficial to meet the microbial metabolic needs, increasing both the overall efficiency of SAR and SBR in terms of organic matter removal (COD) and operational stability. The SAR and SBR were also quite efficient in the nitrification process. The study with SBR with cycle times of 12, 24 and 48 h showed no considerable difference amongst the constituent removals, so that 12 h was considered as optimal time cycle in order to minimize the costs with reactor volume and aeration time. As a general conclusion of the experiment we can say that the aerobic biological treatment, using either submerged aerated reactor (SAR) or sequencing batch reactors (SBR), can be considered a good alternative for post-treatment of old leachate pre-treated in stabilization ponds, but still requires operational adjustments and associations with physical-chemical or advanced oxidation processes for accomplish all discharge standards. / Os sistemas de lagoas de estabilização, bastante presentes em aterros sanitários normalmente não são suficientes para o atendimento aos padrões ambientais de descarte de lixiviado tratado em águas superficiais. Este trabalho avaliou o emprego das tecnologias aeróbias do tipo reator aerado submerso (RAS) e reator em batelada seqüencial (RBS) como opções de pós-tratamento para lixiviado antigo pré-tratado em lagoas de estabilização. A coleta do lixiviado se deu na saída da última lagoa de estabilização do sistema de tratamento de lixiviado (duas anaeróbias em série, seguidas de uma facultativa) localizadas no Aterro Sanitário Metropolitano Oeste (ASMOC), município de Caucaia, Região Metropolitana de Fortaleza, estado do Ceará. Inicialmente foi realizada uma caracterização físico-química do lixiviado efluente e verificação do atendimento aos padrões de descarte. O RAS foi operado em cinco fases, sendo divididas entre esgoto sintético e lixiviado, este último testado com e sem diluição. Avaliou-se o efeito da adição de fonte externa de carbono, etanol, para a fase em que o reator era alimentado com lixiviado sem diluição. O RBS foi confeccionado em acrílico, em formato cilíndrico, com um volume útil de 5,0L, sendo inicialmente estudado o tempo de operação de cada ciclo de 24 horas. Posteriormente, foram avaliados no RBS os tempos totais de ciclo de 12 e 48 horas, além do efeito da adição de etanol no desempenho do reator. Os reatores foram instalados no Laboratório de Saneamento (Labosan) do Departamento de Engenharia Hidráulica e Ambiental (DEHA) da Universidade Federal do Ceará (UFC). Eles foram operados na faixa mesofílica, com temperatura ambiente próxima de 27ºC. Em relação ao lixiviado tratado, os valores encontrados na caracterização físico-química confirmam a recalcitrância e complexidade do lixiviado, indicando que apenas as lagoas de estabilização, não atendem plenamente os padrões de descarte. A presença de compostos recalcitrantes e tóxicos no lixiviado afluente ao RAS durante um dos períodos de investigação causou diminuição na remoção de DQO, mostrando efeito inibitório nos microrganismos presentes no inóculo. Entretanto, em outra fase de investigação, tanto o RAS quanto o RBS se mostraram eficientes e estáveis na remoção de DQO e nitrogênio amoniacal, mesmo tratando lixiviado sem diluição. A adição de etanol como fonte externa de carbono foi benéfica para suprir as necessidades metabólicas microbianas, fazendo aumentar tanto a eficiência global do RAS e RBS em termos de remoção de matéria orgânica (DQO), assim como na estabilidade operacional dos mesmos. O RAS e o RBS foram também bastante eficientes no processo de nitrificação. O estudo no RBS com os tempos de ciclo de 12, 24 e 48 h revelaram que não houve diferença entre os tempos em relação à remoção dos constituintes analisados, fazendo com que se considerasse 12 h como tempo ótimo de ciclo, de forma a minimizar os custos com volume do reator e tempo de aeração. Como conclusão geral do experimento pode-se dizer que o tratamento biológico aeróbio, tanto utilizando reatores aerados submerso (RAS) quanto reatores em batelada seqüencial (RBS), pode ser considerado uma boa alternativa para o pós-tratamento de lixiviado antigos provenientes de sistemas de lagoas de estabilização, mas ainda requer adequações operacionais ou associações com processos físico-químicos ou de oxidação avançados para o enquadramento de todos os constituintes.
2

Tratamento anaeróbio-aeróbio de águas residuárias de suinocultura e reúso na produção de milho para silagem

Cangani, Max Ternero [UNESP] 16 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-16Bitstream added on 2014-06-13T20:16:37Z : No. of bitstreams: 1 cangani_mt_me_jabo_parcial.pdf: 133174 bytes, checksum: 83fdce5233c859451850c9463579de75 (MD5) Bitstreams deleted on 2014-10-03T16:24:40Z: cangani_mt_me_jabo_parcial.pdf,Bitstream added on 2014-10-03T16:27:37Z : No. of bitstreams: 2 cangani_mt_me_jabo_parcial.pdf.txt: 17021 bytes, checksum: 1f48b80f9f09d5f8fc41694b0c3c56ea (MD5) 000681838.pdf: 3677573 bytes, checksum: 863c1c839ba825e42ba039dd26564761 (MD5) Bitstreams deleted on 2014-10-03T16:33:15Z: 000681838.pdf,Bitstream added on 2014-10-03T16:43:28Z : No. of bitstreams: 2 cangani_mt_me_jabo_parcial.pdf.txt: 17021 bytes, checksum: 1f48b80f9f09d5f8fc41694b0c3c56ea (MD5) 000681838.pdf: 3677573 bytes, checksum: 863c1c839ba825e42ba039dd26564761 (MD5) Bitstreams deleted on 2014-10-03T16:48:55Z: 000681838.pdf,Bitstream added on 2014-10-03T16:49:46Z : No. of bitstreams: 1 000681838.pdf: 3677573 bytes, checksum: 863c1c839ba825e42ba039dd26564761 (MD5) Bitstreams deleted on 2014-10-27T11:47:08Z: 000681838.pdf,Bitstream added on 2014-10-27T11:48:04Z : No. of bitstreams: 1 000681838.pdf: 3677573 bytes, checksum: 863c1c839ba825e42ba039dd26564761 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Neste trabalho, avaliou-se o desempenho de dois conjuntos de reatores anaeróbios de fluxo ascendente com manta de lodo (UASB) instalados em série. Os conjuntos I e II foram compostos por dois reatores UASB em série com volumes de 908 e 350 L e de 908 e 188 L, respectivamente. No conjunto II, foi realizado pós tratamento do efluente em um reator operado em batelada sequencial (RBS) com alimentação contínua, com volume de 3000 L. As cargas orgânicas volumétricas (COV) aplicadas no primeiro reator dos conjuntos I e II variaram de 8,36 a 9,95 g DQO total (L d)-1 e de 7,83 a 11,6 g DQO total (L d)-1, respectivamente. As eficiências médias de remoção de DQO total, nitrogênio Kjeldahl (NK), fósforo total (P-total) foram elevadas e variaram de 95 a 97% e de 97 a 99%, de 64 a 67% e de 53 a 69%, e de 80 a 87% e de 71 a 89%, nos conjuntos I e II, respectivamente. As eficiências também foram elevadas para os metais Cu, Fe, Mn e Zn nos conjuntos I e II e variaram de 80 a 91% e de 63 a 80%, de 59 a 80% e de 51 a 72%, de 89 a 97% e de 81 a 98%, de 87 a 98% e de 91 a 99%, respectivamente. A semeadura do milho, foi realizado na safrinha 2009 e na safra 2009/2010, ambos em sistema de plantio direto e convencional, para a confecção de silagem. Os valores do pH observados na silagem não diferiram entre os tratamentos nas duas épocas de semeadura e nos sitemas de plantio direto e convencional. A adubação do milho para confecção de silagem, com dejeto bruto de suíno, com dejetos tratados em sistema anaeróbio e com os dejetos do pós-tratamento, quando comparada com a adubação mineral, não apresentou resultados com diferenças significativas na silagem na maioria dos atributos avaliados. O reúso dos efluentes tratados e do dejeto bruto, não promoveu alterações na nutrição da planta, porém os efluentes... / This study evaluated the performance of two sets of upflow anaerobic sludge blanket (UASB) installed in series. The sets I and II were composed of two UASB reactors in series with volumes of 908 and 350 L and 908 L and 188, respectively. In set II was conducted after the treatment of the effluent in a sequencing batch reactor (SBR) with continuous flux, with a volume of 3000 L. The volumetric organic loads (VOC) applied to the first reactor of the sets I and II ranged from 8.36 to 9.95 g total COD (L d) -1 and 7.83 to 11.6 g total COD (L d) -1, respectively. The average removal efficiencies of total COD, Kjeldahl nitrogen (NK), total phosphorus (total P) were high and ranged from 95 to 97% and 97 to 99%, 64 to 67% and 53 to 69% and 80 to 87% and 71 to 89% in clusters I and II, respectively. The efficiencies were also high for Cu, Fe, Mn and Zn in clusters I and II, and ranged from 80 to 91% and 63 to 80%, 59 to 80% and 51 to 72% from 89 to 97 and 81% to 98%, 87 to 98% and 91 to 99%, respectively. We carried out the swing of maize in the 2009 off-season and 2009/2010 season, both in no-tillage and conventional sistems for making silage. The pH values observed in the silage did not differ significantly between treatments in both seasons of swing and in the sistems of tillage and no-tillage. The fertilization of corn for silage making, with raw pig manure with waste treated in anaerobic system and the waste from the post-treatment compared to mineral fertilization, results showed no significant difference in silage in most parameters. The reuse of treated effluent and raw manure, did not promote changes in the nutrition of corn but the application of treated effluent increased concentrations of N readily available for plants in soil. Even in much larger doses applied compared to the raw waste, the treated effluent, promoted soil contamination by total coliforms and thermotolerant lower
3

UtilizaÃÃo de Reatores AerÃbios como PÃs-Tratamento de Lixiviado Antigo Tratado por Lagoas de EstabilizaÃÃo / Use of Aerobic Reactors as Post-Treatment of leachate by Old Treaty Stabilization Ponds

Antonio Lima Farias Filho 03 August 2010 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Os sistemas de lagoas de estabilizaÃÃo, bastante presentes em aterros sanitÃrios normalmente nÃo sÃo suficientes para o atendimento aos padrÃes ambientais de descarte de lixiviado tratado em Ãguas superficiais. Este trabalho avaliou o emprego das tecnologias aerÃbias do tipo reator aerado submerso (RAS) e reator em batelada seqÃencial (RBS) como opÃÃes de pÃs-tratamento para lixiviado antigo prÃ-tratado em lagoas de estabilizaÃÃo. A coleta do lixiviado se deu na saÃda da Ãltima lagoa de estabilizaÃÃo do sistema de tratamento de lixiviado (duas anaerÃbias em sÃrie, seguidas de uma facultativa) localizadas no Aterro SanitÃrio Metropolitano Oeste (ASMOC), municÃpio de Caucaia, RegiÃo Metropolitana de Fortaleza, estado do CearÃ. Inicialmente foi realizada uma caracterizaÃÃo fÃsico-quÃmica do lixiviado efluente e verificaÃÃo do atendimento aos padrÃes de descarte. O RAS foi operado em cinco fases, sendo divididas entre esgoto sintÃtico e lixiviado, este Ãltimo testado com e sem diluiÃÃo. Avaliou-se o efeito da adiÃÃo de fonte externa de carbono, etanol, para a fase em que o reator era alimentado com lixiviado sem diluiÃÃo. O RBS foi confeccionado em acrÃlico, em formato cilÃndrico, com um volume Ãtil de 5,0L, sendo inicialmente estudado o tempo de operaÃÃo de cada ciclo de 24 horas. Posteriormente, foram avaliados no RBS os tempos totais de ciclo de 12 e 48 horas, alÃm do efeito da adiÃÃo de etanol no desempenho do reator. Os reatores foram instalados no LaboratÃrio de Saneamento (Labosan) do Departamento de Engenharia HidrÃulica e Ambiental (DEHA) da Universidade Federal do Cearà (UFC). Eles foram operados na faixa mesofÃlica, com temperatura ambiente prÃxima de 27ÂC. Em relaÃÃo ao lixiviado tratado, os valores encontrados na caracterizaÃÃo fÃsico-quÃmica confirmam a recalcitrÃncia e complexidade do lixiviado, indicando que apenas as lagoas de estabilizaÃÃo, nÃo atendem plenamente os padrÃes de descarte. A presenÃa de compostos recalcitrantes e tÃxicos no lixiviado afluente ao RAS durante um dos perÃodos de investigaÃÃo causou diminuiÃÃo na remoÃÃo de DQO, mostrando efeito inibitÃrio nos microrganismos presentes no inÃculo. Entretanto, em outra fase de investigaÃÃo, tanto o RAS quanto o RBS se mostraram eficientes e estÃveis na remoÃÃo de DQO e nitrogÃnio amoniacal, mesmo tratando lixiviado sem diluiÃÃo. A adiÃÃo de etanol como fonte externa de carbono foi benÃfica para suprir as necessidades metabÃlicas microbianas, fazendo aumentar tanto a eficiÃncia global do RAS e RBS em termos de remoÃÃo de matÃria orgÃnica (DQO), assim como na estabilidade operacional dos mesmos. O RAS e o RBS foram tambÃm bastante eficientes no processo de nitrificaÃÃo. O estudo no RBS com os tempos de ciclo de 12, 24 e 48 h revelaram que nÃo houve diferenÃa entre os tempos em relaÃÃo à remoÃÃo dos constituintes analisados, fazendo com que se considerasse 12 h como tempo Ãtimo de ciclo, de forma a minimizar os custos com volume do reator e tempo de aeraÃÃo. Como conclusÃo geral do experimento pode-se dizer que o tratamento biolÃgico aerÃbio, tanto utilizando reatores aerados submerso (RAS) quanto reatores em batelada seqÃencial (RBS), pode ser considerado uma boa alternativa para o pÃs-tratamento de lixiviado antigos provenientes de sistemas de lagoas de estabilizaÃÃo, mas ainda requer adequaÃÃes operacionais ou associaÃÃes com processos fÃsico-quÃmicos ou de oxidaÃÃo avanÃados para o enquadramento de todos os constituintes. / The system of stabilization ponds, which is often present in landfills, is usually not efficient to meet environmental standards for disposal of treated leachate on surface waters. This study evaluated the use of submerged aerated reactor (SAR) and sequencing batch reactor (SBR) as post-treatment options for old leachate pre-treated in waste stabilization ponds. The leachate collection took place at the outflow of the last stabilization pond of the treatment system (two anaerobic em series, followed by a facultative pond) located in West Metropolitan Landfill (ASMOC), Caucaia municipality, metropolitan region of Fortaleza, Cearà state. A physical-chemical characterization of the leachate effluent was performed to verify the compliance to reach disposal standards. The SAR was operated in five phases, being divided between synthetic wastewater and leachate, the latter tested with and without dilution. We evaluated the effect of adding an external carbon source, ethanol, for the phase in which the reactor was fed with leachate without dilution. SBR was made of acrylic, in a cylindrical shape with a working volume of 5.0 L and the total time cycle of 24 hours was initially studied. The total time cycles of 12 and 48 hours were also evaluated in the SBR performance, as well as the effect of adding ethanol as carbon source. The reactors were installed at the Laboratory of Sanitation (Labosan) of the Department of Hydraulic and Environmental Engineering (DEHA), Federal University of Cearà (UFC). They were operated in the mesophilic range, with temperature near 27  C. Regarding the treated leachate, the physical-chemical characterization confirmed its recalcitrance and complexity, indicating that only the stabilization ponds did not fully meet the standards of disposal. The presence of recalcitrant and toxic compounds in the leachate influent to the SAR during the investigation period decreased COD removal, showing an inhibitory effect on the microorganisms present in the inoculum. However, in another research phase, both the SAR and SBR were stable and efficient on COD and ammonia removals, even when undiluted leachate was used. The addition of ethanol as external carbon source was beneficial to meet the microbial metabolic needs, increasing both the overall efficiency of SAR and SBR in terms of organic matter removal (COD) and operational stability. The SAR and SBR were also quite efficient in the nitrification process. The study with SBR with cycle times of 12, 24 and 48 h showed no considerable difference amongst the constituent removals, so that 12 h was considered as optimal time cycle in order to minimize the costs with reactor volume and aeration time. As a general conclusion of the experiment we can say that the aerobic biological treatment, using either submerged aerated reactor (SAR) or sequencing batch reactors (SBR), can be considered a good alternative for post-treatment of old leachate pre-treated in stabilization ponds, but still requires operational adjustments and associations with physical-chemical or advanced oxidation processes for accomplish all discharge standards.
4

Aplicação do modelo ASM2d para remoção de carbono, nitrogênio e fósforo em reator em batelada sequencial

CANDIDO, Laíse Alves 21 December 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-07-15T11:55:55Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO LAÍSE ALVES CANDIDO.pdf: 1717138 bytes, checksum: 7884517a24d4674909faeecc260c672f (MD5) / Made available in DSpace on 2016-07-15T11:55:55Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO LAÍSE ALVES CANDIDO.pdf: 1717138 bytes, checksum: 7884517a24d4674909faeecc260c672f (MD5) Previous issue date: 2015-12-21 / O objetivo deste estudo foi avaliar a capacidade de previsão do algoritmo ASM2d modificado, utilizando o programa AQUASIM 2.0® após sua calibração para um reator de bateladas sequenciais com adição de fonte externa de carbono para tratamento de esgoto doméstico objetivando a remoção de matéria orgânica, fósforo e nitrogênio. O sistema piloto está instalado na área experimental da UFPE localizada na Estação de Tratamento de Esgotos da Mangueira que recebe os esgotos de uma comunidade de baixa renda da cidade de Recife-PE. O reator tem volume útil de 160 L (cento e sessenta litros) e opera em batelada com ciclos de 08h (oito horas) dividas em: enchimento e fase anaeróbia (120 min), fase aeróbia (260 min), fase anóxica (50 min), sedimentação (45 min) e esvaziamento (5 min). Os comportamentos previstos pelo modelo para as frações de matéria orgânica, de nitrogênio e de fósforo e do oxigênio dissolvido (OD) e taxa de consumo de oxigênio são coerentes com o descrito pela literatura e concordam com os dados medidos durante a fase de operação do reator. No entanto, faz-se necessária sua validação com maiores séries temporais de dados para maximizar sua confiabilidade, assim como é imprescindível que sejam instalados equipamentos para medição do volume de oxigênio adicionado, monitoramento online do OD e da alcalinidade e controle rigoroso do volume e características do lodo descartado e das frações de sólidos em todas as fases da operação do reator. Embora o modelo não tenha tido sua capacidade de previsão dos parâmetros validada, foi possível verificar a aplicabilidade do ASM2d para a configuração de fases escolhida e com temperatura próxima à real. / The objective of this study was to evaluate the modified ASM2d algorithm foresight capacity using the AQUASIM 2.0® program after its calibration for sequencing batch reactor with the addition of external carbon source for domestic sewage treatment aiming at removal of organic matter, phosphorus and nitrogen. The pilot plant is installed at UFPE’s experimental area at the Wastewater Treatment Plant of Mangueira which receives influent from a low-income community in the city of Recife-PE. The reactor has an effective volume of 160 L (one hundred sixty liters) and operates in batch with cycles of 08h (eight hours) divided into: filling and anaerobic stage (120 min), aerobic phase (260 min), anoxic phase (50 min), sedimentation (45 minutes) and emptying (5 min). The behavior predicted by the model for fractions of organic matter, nitrogen and phosphorus, dissolved oxygen (DO) and oxygen uptake rate are consistent with that described in the literature and agree with the measured data during reactor operation phase. However, a validation with larger data time series is necessary to maximize its reliability, as it is indispensable to have installed equipment for measuring oxygen input, online monitoring of DO and alkalinity and strict control of the volume and characteristics of the excess sludge and solid fractions for all phases of reactor operation. Although the model has not had its predictive power validated, it was possible to verify the applicability of ASM2d for the chosen stage setting and at a temperature close to the operational.

Page generated in 0.1226 seconds