1

Desempenho de reatores biológicos aeróbios de leito fluidizado inverso na remoçao de carga orgânica

Zim, Graziela January 2006 (has links)
Este estudo avaliou a eficiência de reatores biológicos aeróbios de leito fluidizado inverso na remoção de matéria orgânica quando submetidos a diferentes condições operacionais (vazão de recirculação e carga orgânica aplicada). O experimento, em escala de laboratório, foi realizado em três reatores cilíndricos (R1, R2 e R3) com altura total de 2,00 m, diâmetro interno de 0,10 m e volume útil de 15,70 L. Como meio suporte para o desenvolvimento do biofilme foram utilizadas partículas de polipropileno (PP) em volume equivalente a 40% do volume útil do reator. O afluente entrava nos reatores pelo topo e saía pelo fundo e o oxigênio era fornecido através de um aerador poroso. Os reatores R1, R2 e R3 foram operados com vazão de recirculação de 2,50 L/min, 4,00 L/min e 5,50 L/min, respectivamente, durante todo período experimental. Os reatores foram alimentados com esgoto sintético caracteristicamente doméstico e o experimento consistiu de três etapas, conforme a carga orgânica aplicada: Etapa de Menor Carga – 0,70 Kg DQO/m3.dia; Etapa de Carga Intermediária – 1,70 Kg DQO/m3.dia e Etapa de Maior Carga – 3,90 Kg DQO/m3.dia. A vazão de alimentação foi mantida constante durante todo período experimental correspondendo ao TDH de 12 horas.O acompanhamento dos reatores foi realizado com medidas de DQO, sólidos livres (suspensão) e aderidos (biofilme). Foi determinada também a velocidade ascensional das biopartículas no meio líquido, tendo como motivo a identificação das possíveis causas da expansão excessiva ocorrida durante a realização do experimento. Os resultados obtidos demonstraram elevada eficiência de remoção carbonácea em termos de DQO, com médias superior a 93% na etapa de Carga Intermediária e em torno de 90% para a etapa de Maior Carga. Conforme avaliação estatística, não houve evidências de que a vazão de recirculação tenha efeito sobre a eficiência de remoção carbonácea. O aumento da carga orgânica afluente reduziu de forma significativa a eficiência de remoção carbonácea apenas no reator de menor vazão de recirculação. Em relação à quantidade de sólidos voláteis, o aumento da vazão de recirculação resultou em aumento dos sólidos voláteis aderidos, porém não foi identificado efeito sobre a quantidade de sólidos voláteis livres.O aumento de carga aplicada resultou em aumento significativo na quantidade média de sólidos voláteis livres nos reatores. Quanto aos sólidos voláteis aderidos, o acréscimo de carga afluente repercutiu de forma diferente nos três reatores: para a menor vazão de recirculação houve redução na massa de sólidos voláteis aderidos, para a vazão de recirculação intermediária ocorreu aumento da massa de sólidos voláteis aderidos e para a maior vazão de recirculação o aumento da carga aplicada não influenciou a quantidade de sólidos aderidos voláteis presentes no reator. A velocidade ascensional média das biopartículas diminuiu com o aumento da vazão de recirculação, significando que quanto maior a vazão de recirculação maior a densidade das biopartículas. / This study evaluated the efficiency of down flow aerobic fluidized bed reactors for the removal of organic mater submitted to different operational conditions (recirculation flow and applied organic load). The experiment was run on 3 cylindrical lab scale reactors (R1, R2 and R3) with 2 m total height, 0.10 m internal diameter and working volume of 15.70 L. Polypropylene particles were used as the support material for the development of the biofilm occupying 40% of the working volume of the reactors. The influent were applied at the top of the columns and withdraw from the bottom and the oxygen was supplied throughout a porous stone. The reactors R1, R2 and R3 were operated with recirculation flow of 2,50, 4.00 and 5.50 L. min-1, respectively, throughout the experimental work.The reactors were fed with synthetic wastewater similar to sanitary wastewater and the experiment was performed in 3 steps, according to the applied organic loading rate, namely: Lower Load - 0,70 Kg COD/m3.dia; Intermediate Load - 1,70 Kg COD/m3.dia; Higher Load - 3,90 Kg COD/m3.dia. The feeding flow was maintained constant throughout the experiment to obtain HDT equal to 12 hours. The reactors were monitored with conventional parameters such as COD, free suspended solids and attached suspended solids (biofilm). The upflow velocity of the bioparticles in the liquid phase was also determined with the purpose to identify the potential causes of the excessive expansion of the bed observed during the experimental work. The experimental results demonstrated high efficiency of carbonaceous COD removal, with average values above 93 % during the Intermediate Load step and around 90 % for the Higher Load. According to statistical evaluation, the recirculation flow did not provided significant effect upon the carbonaceous organic matter removal. The increase in applied organic load caused a significant decrease only to the reactor operated with the lower recirculation flow. Regarding the amount of volatile solids, the increase of the recirculation flow resulted in the increase of the attached volatile solids, however it was not identified any effect upon the amount of free volatile solids. The increase of applied organic load resulted in significant increase of the amount of the free volatile solids in the reactors. Regarding the attached volatile solids, the increase of applied organic load resulted in misleading behavior of the reactors, as follows: the lower recirculation flow resulted in a reduction of the amount of attached volatile solids; the intermediate recirculation flow resulted in an increase of the attached volatile solids, while it was not observed any significant variation in the amount of attached volatile solids inside the reactor operated with the higher recirculation flow. The average accession velocity of the bioparticles decreased with the increase of the recirculation flow, implying that the recirculation flow resulted in higher values of the bioparticles density.
2

Desempenho de reatores biológicos aeróbios de leito fluidizado inverso na remoçao de carga orgânica

Zim, Graziela January 2006 (has links)
Este estudo avaliou a eficiência de reatores biológicos aeróbios de leito fluidizado inverso na remoção de matéria orgânica quando submetidos a diferentes condições operacionais (vazão de recirculação e carga orgânica aplicada). O experimento, em escala de laboratório, foi realizado em três reatores cilíndricos (R1, R2 e R3) com altura total de 2,00 m, diâmetro interno de 0,10 m e volume útil de 15,70 L. Como meio suporte para o desenvolvimento do biofilme foram utilizadas partículas de polipropileno (PP) em volume equivalente a 40% do volume útil do reator. O afluente entrava nos reatores pelo topo e saía pelo fundo e o oxigênio era fornecido através de um aerador poroso. Os reatores R1, R2 e R3 foram operados com vazão de recirculação de 2,50 L/min, 4,00 L/min e 5,50 L/min, respectivamente, durante todo período experimental. Os reatores foram alimentados com esgoto sintético caracteristicamente doméstico e o experimento consistiu de três etapas, conforme a carga orgânica aplicada: Etapa de Menor Carga – 0,70 Kg DQO/m3.dia; Etapa de Carga Intermediária – 1,70 Kg DQO/m3.dia e Etapa de Maior Carga – 3,90 Kg DQO/m3.dia. A vazão de alimentação foi mantida constante durante todo período experimental correspondendo ao TDH de 12 horas.O acompanhamento dos reatores foi realizado com medidas de DQO, sólidos livres (suspensão) e aderidos (biofilme). Foi determinada também a velocidade ascensional das biopartículas no meio líquido, tendo como motivo a identificação das possíveis causas da expansão excessiva ocorrida durante a realização do experimento. Os resultados obtidos demonstraram elevada eficiência de remoção carbonácea em termos de DQO, com médias superior a 93% na etapa de Carga Intermediária e em torno de 90% para a etapa de Maior Carga. Conforme avaliação estatística, não houve evidências de que a vazão de recirculação tenha efeito sobre a eficiência de remoção carbonácea. O aumento da carga orgânica afluente reduziu de forma significativa a eficiência de remoção carbonácea apenas no reator de menor vazão de recirculação. Em relação à quantidade de sólidos voláteis, o aumento da vazão de recirculação resultou em aumento dos sólidos voláteis aderidos, porém não foi identificado efeito sobre a quantidade de sólidos voláteis livres.O aumento de carga aplicada resultou em aumento significativo na quantidade média de sólidos voláteis livres nos reatores. Quanto aos sólidos voláteis aderidos, o acréscimo de carga afluente repercutiu de forma diferente nos três reatores: para a menor vazão de recirculação houve redução na massa de sólidos voláteis aderidos, para a vazão de recirculação intermediária ocorreu aumento da massa de sólidos voláteis aderidos e para a maior vazão de recirculação o aumento da carga aplicada não influenciou a quantidade de sólidos aderidos voláteis presentes no reator. A velocidade ascensional média das biopartículas diminuiu com o aumento da vazão de recirculação, significando que quanto maior a vazão de recirculação maior a densidade das biopartículas. / This study evaluated the efficiency of down flow aerobic fluidized bed reactors for the removal of organic mater submitted to different operational conditions (recirculation flow and applied organic load). The experiment was run on 3 cylindrical lab scale reactors (R1, R2 and R3) with 2 m total height, 0.10 m internal diameter and working volume of 15.70 L. Polypropylene particles were used as the support material for the development of the biofilm occupying 40% of the working volume of the reactors. The influent were applied at the top of the columns and withdraw from the bottom and the oxygen was supplied throughout a porous stone. The reactors R1, R2 and R3 were operated with recirculation flow of 2,50, 4.00 and 5.50 L. min-1, respectively, throughout the experimental work.The reactors were fed with synthetic wastewater similar to sanitary wastewater and the experiment was performed in 3 steps, according to the applied organic loading rate, namely: Lower Load - 0,70 Kg COD/m3.dia; Intermediate Load - 1,70 Kg COD/m3.dia; Higher Load - 3,90 Kg COD/m3.dia. The feeding flow was maintained constant throughout the experiment to obtain HDT equal to 12 hours. The reactors were monitored with conventional parameters such as COD, free suspended solids and attached suspended solids (biofilm). The upflow velocity of the bioparticles in the liquid phase was also determined with the purpose to identify the potential causes of the excessive expansion of the bed observed during the experimental work. The experimental results demonstrated high efficiency of carbonaceous COD removal, with average values above 93 % during the Intermediate Load step and around 90 % for the Higher Load. According to statistical evaluation, the recirculation flow did not provided significant effect upon the carbonaceous organic matter removal. The increase in applied organic load caused a significant decrease only to the reactor operated with the lower recirculation flow. Regarding the amount of volatile solids, the increase of the recirculation flow resulted in the increase of the attached volatile solids, however it was not identified any effect upon the amount of free volatile solids. The increase of applied organic load resulted in significant increase of the amount of the free volatile solids in the reactors. Regarding the attached volatile solids, the increase of applied organic load resulted in misleading behavior of the reactors, as follows: the lower recirculation flow resulted in a reduction of the amount of attached volatile solids; the intermediate recirculation flow resulted in an increase of the attached volatile solids, while it was not observed any significant variation in the amount of attached volatile solids inside the reactor operated with the higher recirculation flow. The average accession velocity of the bioparticles decreased with the increase of the recirculation flow, implying that the recirculation flow resulted in higher values of the bioparticles density.
3

Desempenho de reatores biológicos aeróbios de leito fluidizado inverso na remoçao de carga orgânica

Zim, Graziela January 2006 (has links)
Este estudo avaliou a eficiência de reatores biológicos aeróbios de leito fluidizado inverso na remoção de matéria orgânica quando submetidos a diferentes condições operacionais (vazão de recirculação e carga orgânica aplicada). O experimento, em escala de laboratório, foi realizado em três reatores cilíndricos (R1, R2 e R3) com altura total de 2,00 m, diâmetro interno de 0,10 m e volume útil de 15,70 L. Como meio suporte para o desenvolvimento do biofilme foram utilizadas partículas de polipropileno (PP) em volume equivalente a 40% do volume útil do reator. O afluente entrava nos reatores pelo topo e saía pelo fundo e o oxigênio era fornecido através de um aerador poroso. Os reatores R1, R2 e R3 foram operados com vazão de recirculação de 2,50 L/min, 4,00 L/min e 5,50 L/min, respectivamente, durante todo período experimental. Os reatores foram alimentados com esgoto sintético caracteristicamente doméstico e o experimento consistiu de três etapas, conforme a carga orgânica aplicada: Etapa de Menor Carga – 0,70 Kg DQO/m3.dia; Etapa de Carga Intermediária – 1,70 Kg DQO/m3.dia e Etapa de Maior Carga – 3,90 Kg DQO/m3.dia. A vazão de alimentação foi mantida constante durante todo período experimental correspondendo ao TDH de 12 horas.O acompanhamento dos reatores foi realizado com medidas de DQO, sólidos livres (suspensão) e aderidos (biofilme). Foi determinada também a velocidade ascensional das biopartículas no meio líquido, tendo como motivo a identificação das possíveis causas da expansão excessiva ocorrida durante a realização do experimento. Os resultados obtidos demonstraram elevada eficiência de remoção carbonácea em termos de DQO, com médias superior a 93% na etapa de Carga Intermediária e em torno de 90% para a etapa de Maior Carga. Conforme avaliação estatística, não houve evidências de que a vazão de recirculação tenha efeito sobre a eficiência de remoção carbonácea. O aumento da carga orgânica afluente reduziu de forma significativa a eficiência de remoção carbonácea apenas no reator de menor vazão de recirculação. Em relação à quantidade de sólidos voláteis, o aumento da vazão de recirculação resultou em aumento dos sólidos voláteis aderidos, porém não foi identificado efeito sobre a quantidade de sólidos voláteis livres.O aumento de carga aplicada resultou em aumento significativo na quantidade média de sólidos voláteis livres nos reatores. Quanto aos sólidos voláteis aderidos, o acréscimo de carga afluente repercutiu de forma diferente nos três reatores: para a menor vazão de recirculação houve redução na massa de sólidos voláteis aderidos, para a vazão de recirculação intermediária ocorreu aumento da massa de sólidos voláteis aderidos e para a maior vazão de recirculação o aumento da carga aplicada não influenciou a quantidade de sólidos aderidos voláteis presentes no reator. A velocidade ascensional média das biopartículas diminuiu com o aumento da vazão de recirculação, significando que quanto maior a vazão de recirculação maior a densidade das biopartículas. / This study evaluated the efficiency of down flow aerobic fluidized bed reactors for the removal of organic mater submitted to different operational conditions (recirculation flow and applied organic load). The experiment was run on 3 cylindrical lab scale reactors (R1, R2 and R3) with 2 m total height, 0.10 m internal diameter and working volume of 15.70 L. Polypropylene particles were used as the support material for the development of the biofilm occupying 40% of the working volume of the reactors. The influent were applied at the top of the columns and withdraw from the bottom and the oxygen was supplied throughout a porous stone. The reactors R1, R2 and R3 were operated with recirculation flow of 2,50, 4.00 and 5.50 L. min-1, respectively, throughout the experimental work.The reactors were fed with synthetic wastewater similar to sanitary wastewater and the experiment was performed in 3 steps, according to the applied organic loading rate, namely: Lower Load - 0,70 Kg COD/m3.dia; Intermediate Load - 1,70 Kg COD/m3.dia; Higher Load - 3,90 Kg COD/m3.dia. The feeding flow was maintained constant throughout the experiment to obtain HDT equal to 12 hours. The reactors were monitored with conventional parameters such as COD, free suspended solids and attached suspended solids (biofilm). The upflow velocity of the bioparticles in the liquid phase was also determined with the purpose to identify the potential causes of the excessive expansion of the bed observed during the experimental work. The experimental results demonstrated high efficiency of carbonaceous COD removal, with average values above 93 % during the Intermediate Load step and around 90 % for the Higher Load. According to statistical evaluation, the recirculation flow did not provided significant effect upon the carbonaceous organic matter removal. The increase in applied organic load caused a significant decrease only to the reactor operated with the lower recirculation flow. Regarding the amount of volatile solids, the increase of the recirculation flow resulted in the increase of the attached volatile solids, however it was not identified any effect upon the amount of free volatile solids. The increase of applied organic load resulted in significant increase of the amount of the free volatile solids in the reactors. Regarding the attached volatile solids, the increase of applied organic load resulted in misleading behavior of the reactors, as follows: the lower recirculation flow resulted in a reduction of the amount of attached volatile solids; the intermediate recirculation flow resulted in an increase of the attached volatile solids, while it was not observed any significant variation in the amount of attached volatile solids inside the reactor operated with the higher recirculation flow. The average accession velocity of the bioparticles decreased with the increase of the recirculation flow, implying that the recirculation flow resulted in higher values of the bioparticles density.
4

Desempenho de reatores UASB expostos a choques de carga hidráulica e diluição de matéria orgânica devidos a eventos de chuva

Salazar Peláez, Mónica Liliana January 2007 (has links)
Os sistemas de esgotos urbanos são classificados em separador absoluto, separador parcial e unitário, conforme o grau de separação que existe no recolhimento dos esgotos sanitários e das águas de drenagem pluviais. Embora a diretriz das cidades brasileiras seja a adoção do sistema separador, na prática ocorre uma importante contribuição das águas de chuvas nas vazões afluentes às estações de tratamento de esgotos como produto das interconexões existentes, clandestinas ou não, entre as redes de esgotos sanitários e pluviais. Esta pesquisa investigou os impactos causados pelos choques de carga orgânica e hidráulica provocados pela contribuição das águas pluviais no desempenho de reatores UASB e seu tempo de recuperação depois de sofrer estes choques. Três reatores de acrílico de 17 litros foram construídos no Laboratório de Saneamento Ambiental do IPH. Os reatores trataram esgoto sintético simulando a concentração de DQO de esgotos domésticos a uma temperatura de 30 ± 2 °C. Um dos reatores serviu de controle enquanto os outros dois receberam choques de carga hidráulica (aumento de vazão) e diluição de matéria orgânica, simultaneamente. A operação dos reatores foi dividida em três fases: 1°) aclimatação, 2°) choques individuais de carga hidráulica e diluição de matéria orgânica 3°) simulação de uma temporada de chuva. Os choques tiveram um efeito deletério na qualidade do efluente, ocasionando quedas na eficiência de remoção de DQO total de até quase 600% e de 200% na eficiência de remoção de DQO dissolvida nos choques mais severos. Também constatou-se perda de parte da biomassa presente nos reatores devido ao aumento excessivo na velocidade ascensional do fluxo. Esta perda tornou-se menor com o tempo devido à pressão de seleção exercida pelos sucessivos choques. O pH dentro dos reatores manteve-se sempre perto da faixa neutra, porém apresentou-se um consumo de alcalinidade que se prolongou por até três vezes o tempo de detenção hidráulica após o início dos choques, devido provavelmente ao aumento na concentração de ácidos graxos voláteis no efluente. A produção de biogás também diminuiu como conseqüência da diluição da carga orgânica afluente. Os efeitos e o tempo de recuperação após os choques dependeram da sua duração e magnitude, sendo que os choques mais severos (menor concentração de matéria orgânica afluente e TDH) causaram maior deterioração na qualidade do efluente e requereram maior tempo de recuperação.Já no que diz respeito às características físico-químicas e biológicas do lodo, verificou-se que os choques causaram diminuição no tamanho médio dos grânulos do lodo e na sua velocidade de sedimentação, provavelmente devido ao aumento das forças abrasivas v provocado pelo incremento na velocidade ascensional do fluxo. De igual modo, a atividade metanogênica específica também apresentou quedas devidas, provavelmente, à diluição da carga orgânica afluente e à diminuição do tamanho das partículas do lodo. / Sewerage systems are classified as separate, partially separated, or combined, according to the degree of separation that exists in the collection of municipal wastewater and stormwater runoff. Although the official policy of brazilian cities is for adoption of the separate system, the actual scenario shows that there are significant contributions of stormwater to the flows that are transported to the wastewater treatment plants, partly because of the inappropriate interconnections that exist between the systems. This research investigated the impacts that organic and hydraulic shock loads brought by stormwater contributions have on the efficiency of UASB reactors, as well as the recovery time after the ending of the shocks. Three 17-liters acrylic reactors were built in the Environmental Technology Laboratory at IPH. The reactors were fed with synthetic wastewater prepared to resemble the organic content of wastewater. All reactors were operated at a temperature of 30 ± 2ºC. One of the reactors was used as control while the other two received hydraulic shocks with organic matter dilution, simultaneously. Reactor’s operation was divided in three phases: 1º) star-up, 2º) single organic and hydraulic shocks, and 3º) rain season simulation, with multiple shocks.Shocks have a deleterious effect on the reactor effluent quality. In the most severe cases, drops in removal efficiencies reached up to 200% and 600% for dissolved and total DQO, respectively. Reactor biomass washout occurred due to the increasing upflow velocity. This loss was dampened by the selective pressure exerted by successive shocks. pH in the reactors remained in the neutral range, although alkalinity was consumed for as long as three detention times, probably due to an increase in the concentration of volatile fatty acids in the liquid. Dilution also caused a decrease in biogas production. Recovery time depended on the duration and intensity of the shock, with more severe shocks demanding more time for recovery. The impacts of the shocks on the treatment efficiency depended on duration, organic dilution rate and flowrate increase. Longer shocks, with higher flowrates and dilution rate resulted in the worst conditions for the reactor. Shocks loads caused a decrease in the mean size of the sludge granule, as well as in their sedimentation velocities, probably because of an increase in the abrasive forces acting on the granules brought by the upflow velocity. The specific methanogenic activity also decreased with higher dilution and smaller sized sludge granules.
5

Desempenho de reatores UASB expostos a choques de carga hidráulica e diluição de matéria orgânica devidos a eventos de chuva

Salazar Peláez, Mónica Liliana January 2007 (has links)
Os sistemas de esgotos urbanos são classificados em separador absoluto, separador parcial e unitário, conforme o grau de separação que existe no recolhimento dos esgotos sanitários e das águas de drenagem pluviais. Embora a diretriz das cidades brasileiras seja a adoção do sistema separador, na prática ocorre uma importante contribuição das águas de chuvas nas vazões afluentes às estações de tratamento de esgotos como produto das interconexões existentes, clandestinas ou não, entre as redes de esgotos sanitários e pluviais. Esta pesquisa investigou os impactos causados pelos choques de carga orgânica e hidráulica provocados pela contribuição das águas pluviais no desempenho de reatores UASB e seu tempo de recuperação depois de sofrer estes choques. Três reatores de acrílico de 17 litros foram construídos no Laboratório de Saneamento Ambiental do IPH. Os reatores trataram esgoto sintético simulando a concentração de DQO de esgotos domésticos a uma temperatura de 30 ± 2 °C. Um dos reatores serviu de controle enquanto os outros dois receberam choques de carga hidráulica (aumento de vazão) e diluição de matéria orgânica, simultaneamente. A operação dos reatores foi dividida em três fases: 1°) aclimatação, 2°) choques individuais de carga hidráulica e diluição de matéria orgânica 3°) simulação de uma temporada de chuva. Os choques tiveram um efeito deletério na qualidade do efluente, ocasionando quedas na eficiência de remoção de DQO total de até quase 600% e de 200% na eficiência de remoção de DQO dissolvida nos choques mais severos. Também constatou-se perda de parte da biomassa presente nos reatores devido ao aumento excessivo na velocidade ascensional do fluxo. Esta perda tornou-se menor com o tempo devido à pressão de seleção exercida pelos sucessivos choques. O pH dentro dos reatores manteve-se sempre perto da faixa neutra, porém apresentou-se um consumo de alcalinidade que se prolongou por até três vezes o tempo de detenção hidráulica após o início dos choques, devido provavelmente ao aumento na concentração de ácidos graxos voláteis no efluente. A produção de biogás também diminuiu como conseqüência da diluição da carga orgânica afluente. Os efeitos e o tempo de recuperação após os choques dependeram da sua duração e magnitude, sendo que os choques mais severos (menor concentração de matéria orgânica afluente e TDH) causaram maior deterioração na qualidade do efluente e requereram maior tempo de recuperação.Já no que diz respeito às características físico-químicas e biológicas do lodo, verificou-se que os choques causaram diminuição no tamanho médio dos grânulos do lodo e na sua velocidade de sedimentação, provavelmente devido ao aumento das forças abrasivas v provocado pelo incremento na velocidade ascensional do fluxo. De igual modo, a atividade metanogênica específica também apresentou quedas devidas, provavelmente, à diluição da carga orgânica afluente e à diminuição do tamanho das partículas do lodo. / Sewerage systems are classified as separate, partially separated, or combined, according to the degree of separation that exists in the collection of municipal wastewater and stormwater runoff. Although the official policy of brazilian cities is for adoption of the separate system, the actual scenario shows that there are significant contributions of stormwater to the flows that are transported to the wastewater treatment plants, partly because of the inappropriate interconnections that exist between the systems. This research investigated the impacts that organic and hydraulic shock loads brought by stormwater contributions have on the efficiency of UASB reactors, as well as the recovery time after the ending of the shocks. Three 17-liters acrylic reactors were built in the Environmental Technology Laboratory at IPH. The reactors were fed with synthetic wastewater prepared to resemble the organic content of wastewater. All reactors were operated at a temperature of 30 ± 2ºC. One of the reactors was used as control while the other two received hydraulic shocks with organic matter dilution, simultaneously. Reactor’s operation was divided in three phases: 1º) star-up, 2º) single organic and hydraulic shocks, and 3º) rain season simulation, with multiple shocks.Shocks have a deleterious effect on the reactor effluent quality. In the most severe cases, drops in removal efficiencies reached up to 200% and 600% for dissolved and total DQO, respectively. Reactor biomass washout occurred due to the increasing upflow velocity. This loss was dampened by the selective pressure exerted by successive shocks. pH in the reactors remained in the neutral range, although alkalinity was consumed for as long as three detention times, probably due to an increase in the concentration of volatile fatty acids in the liquid. Dilution also caused a decrease in biogas production. Recovery time depended on the duration and intensity of the shock, with more severe shocks demanding more time for recovery. The impacts of the shocks on the treatment efficiency depended on duration, organic dilution rate and flowrate increase. Longer shocks, with higher flowrates and dilution rate resulted in the worst conditions for the reactor. Shocks loads caused a decrease in the mean size of the sludge granule, as well as in their sedimentation velocities, probably because of an increase in the abrasive forces acting on the granules brought by the upflow velocity. The specific methanogenic activity also decreased with higher dilution and smaller sized sludge granules.
6

Desempenho de reatores UASB expostos a choques de carga hidráulica e diluição de matéria orgânica devidos a eventos de chuva

Salazar Peláez, Mónica Liliana January 2007 (has links)
Os sistemas de esgotos urbanos são classificados em separador absoluto, separador parcial e unitário, conforme o grau de separação que existe no recolhimento dos esgotos sanitários e das águas de drenagem pluviais. Embora a diretriz das cidades brasileiras seja a adoção do sistema separador, na prática ocorre uma importante contribuição das águas de chuvas nas vazões afluentes às estações de tratamento de esgotos como produto das interconexões existentes, clandestinas ou não, entre as redes de esgotos sanitários e pluviais. Esta pesquisa investigou os impactos causados pelos choques de carga orgânica e hidráulica provocados pela contribuição das águas pluviais no desempenho de reatores UASB e seu tempo de recuperação depois de sofrer estes choques. Três reatores de acrílico de 17 litros foram construídos no Laboratório de Saneamento Ambiental do IPH. Os reatores trataram esgoto sintético simulando a concentração de DQO de esgotos domésticos a uma temperatura de 30 ± 2 °C. Um dos reatores serviu de controle enquanto os outros dois receberam choques de carga hidráulica (aumento de vazão) e diluição de matéria orgânica, simultaneamente. A operação dos reatores foi dividida em três fases: 1°) aclimatação, 2°) choques individuais de carga hidráulica e diluição de matéria orgânica 3°) simulação de uma temporada de chuva. Os choques tiveram um efeito deletério na qualidade do efluente, ocasionando quedas na eficiência de remoção de DQO total de até quase 600% e de 200% na eficiência de remoção de DQO dissolvida nos choques mais severos. Também constatou-se perda de parte da biomassa presente nos reatores devido ao aumento excessivo na velocidade ascensional do fluxo. Esta perda tornou-se menor com o tempo devido à pressão de seleção exercida pelos sucessivos choques. O pH dentro dos reatores manteve-se sempre perto da faixa neutra, porém apresentou-se um consumo de alcalinidade que se prolongou por até três vezes o tempo de detenção hidráulica após o início dos choques, devido provavelmente ao aumento na concentração de ácidos graxos voláteis no efluente. A produção de biogás também diminuiu como conseqüência da diluição da carga orgânica afluente. Os efeitos e o tempo de recuperação após os choques dependeram da sua duração e magnitude, sendo que os choques mais severos (menor concentração de matéria orgânica afluente e TDH) causaram maior deterioração na qualidade do efluente e requereram maior tempo de recuperação.Já no que diz respeito às características físico-químicas e biológicas do lodo, verificou-se que os choques causaram diminuição no tamanho médio dos grânulos do lodo e na sua velocidade de sedimentação, provavelmente devido ao aumento das forças abrasivas v provocado pelo incremento na velocidade ascensional do fluxo. De igual modo, a atividade metanogênica específica também apresentou quedas devidas, provavelmente, à diluição da carga orgânica afluente e à diminuição do tamanho das partículas do lodo. / Sewerage systems are classified as separate, partially separated, or combined, according to the degree of separation that exists in the collection of municipal wastewater and stormwater runoff. Although the official policy of brazilian cities is for adoption of the separate system, the actual scenario shows that there are significant contributions of stormwater to the flows that are transported to the wastewater treatment plants, partly because of the inappropriate interconnections that exist between the systems. This research investigated the impacts that organic and hydraulic shock loads brought by stormwater contributions have on the efficiency of UASB reactors, as well as the recovery time after the ending of the shocks. Three 17-liters acrylic reactors were built in the Environmental Technology Laboratory at IPH. The reactors were fed with synthetic wastewater prepared to resemble the organic content of wastewater. All reactors were operated at a temperature of 30 ± 2ºC. One of the reactors was used as control while the other two received hydraulic shocks with organic matter dilution, simultaneously. Reactor’s operation was divided in three phases: 1º) star-up, 2º) single organic and hydraulic shocks, and 3º) rain season simulation, with multiple shocks.Shocks have a deleterious effect on the reactor effluent quality. In the most severe cases, drops in removal efficiencies reached up to 200% and 600% for dissolved and total DQO, respectively. Reactor biomass washout occurred due to the increasing upflow velocity. This loss was dampened by the selective pressure exerted by successive shocks. pH in the reactors remained in the neutral range, although alkalinity was consumed for as long as three detention times, probably due to an increase in the concentration of volatile fatty acids in the liquid. Dilution also caused a decrease in biogas production. Recovery time depended on the duration and intensity of the shock, with more severe shocks demanding more time for recovery. The impacts of the shocks on the treatment efficiency depended on duration, organic dilution rate and flowrate increase. Longer shocks, with higher flowrates and dilution rate resulted in the worst conditions for the reactor. Shocks loads caused a decrease in the mean size of the sludge granule, as well as in their sedimentation velocities, probably because of an increase in the abrasive forces acting on the granules brought by the upflow velocity. The specific methanogenic activity also decreased with higher dilution and smaller sized sludge granules.