• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da vulnerabilidade natural à contaminação do Sistema Aquífero Serra Geral do Paraná

Borges, Vinícius Menezes January 2017 (has links)
Este trabalho teve como objetivo avaliar a vulnerabilidade natural à contaminação do Sistema Aquífero Serra Geral (SASG) no estado do Paraná, bem como realizar uma comparação dos métodos DRASTIC e GOD, visando estabelecer vantagens e desvantagens da aplicação cada método. A vulnerabilidade natural à contaminação indica a sensibilidade à poluição de um aquífero a partir de suas características intrínsecas. Para que fosse realizada a avaliação da vulnerabilidade pelo método DRASTIC, foi necessária a estimativa das taxas de recarga das águas subterrâneas na área de estudo. Para isso, foram aplicados e comparados dois métodos: balanço hídrico e separação do escoamento de base. No método DRASTIC, adaptações foram feitas nos parâmetros A (Meio Aquífero), em que foi utilizada a densidade de lineamentos; I (Impacto da Zona Vadosa), em que foi avaliada a aptidão dos solos para disposição de resíduos sólidos; e C (Condutividade Hidráulica), em que foram utilizados valores de transmissividade. Estas adaptações tiveram como objetivo adequar o método à avaliação da vulnerabilidade em aquíferos fraturados. Os mapas de vulnerabilidade pelos métodos DRASTIC e GOD foram comparados através da normalização dos índices, visando inseri-los em um mesmo intervalo. Para a estimativa de recarga, os resultados apresentaram taxas média por bacia variando de 156 a 489 mm/ano pelo método da separação do escoamento de base e de 179 a 365 mm/ano pelo método do balanço hídrico. As diferenças apresentadas podem ser consideradas como aceitáveis, se considerados as diversas incertezas envolvidas no processo de estimativa de recarga e o fato de que os métodos utilizam dados diferentes na análise. Quanto ao mapeamento da vulnerabilidade natural à contaminação, o método DRASTIC apresentou graus de vulnerabilidade baixa (5,01%), moderada (83,13%) e elevada (11,85%). Já o método GOD apresentou vulnerabilidades baixa (66,21%), moderada (0,67%), alta (14,32%) e extrema (18,81%). As principais diferenças relativas entre os dois métodos ocorreram em locais onde a vulnerabilidade é determinada por parâmetros que não são mútuos dos métodos. De maneira geral, o método DRASTIC se mostrou mais restritivo quanto ao uso e ocupação do solo que o método GOD, pois apresentou índices mais elevados de vulnerabilidade quando considerada a área de estudo como um todo. O método DRASTIC apresentou maior grau de detalhe na avaliação e mais valores intermediários. Já o método GOD apresentou variação brusca dos índices em muitas regiões. Isso se deve principalmente ao fato de que este utiliza apenas três parâmetros em sua avaliação, enquanto o DRASTIC utiliza sete. Apesar do método DRASTIC apresentar resultados mais satisfatórios, a escolha do método deve estar condicionada à disponibilidade de dados e de recursos humanos e financeiros. Ambos os métodos podem ser utilizados em estudos regionais, entretanto, os resultados aqui obtidos devem ser utilizados com cautela em estudos que requerem maior grau de detalhe. / This paper aimed to evaluate natural vulnerability to contamination on Serra Geral Aquifer System (SASG) in Paraná state, Brazil, as well as comparing DRASTIC and GOD methods, aiming to stablish advantages and disadvantages of each method. Natural vulnerability to contamination indicates the sensibility to pollution of an aquifer considering its intrinsic characteristics. In order to carry out the evaluation through DRASTIC method, it was necessary to estimate groundwater recharge rates in the study area. To do so, two methods were applied and compared: baseflow separation and water balance. Concerning the DRASTIC method, some adaptations were made in the following parameters: A (Aquifer Media), in which was used lineaments density; I (Impact of Vadose Zone), in which was considered the soil capacity to receive solid waste; and C (Hydraulic Conductivity), in which was used aquifer transmissivity. These adaptations aimed to adapt the method for vulnerability evaluation on fractured aquifers. Vulnerability maps by DRASTIC and GOD were compared through index normalization, inserting them at the same interval. For recharge estimation, results showed average values per basin of 156 to 489 mm/year by baseflow separation and 179 to 365 mm/year by water balance. The differences can be considered as acceptable when considered the various uncertainties involved and the fact that the methods uses different data on the analysis. Concerning the natural vulnerability to contamination mapping, DRASTIC method showed the following levels of vulnerability: low (5,01%), moderate (83,13%) and high (11,85%). GOD method showed the following levels: low (66,21%), moderate (0,67%), high (14,32%) and extreme (18,81%). The main differences related to both methods occurred in areas where the vulnerability is determined by mutual parameters. In general, DRASTIC method showed to be more restrictive in terms of land use than GOD, as it presented high indexes when considered all the study area. DRASTIC method showed a higher level of spatial detail and more intermediary values. The GOD method showed abrupt variation of indexes in many areas. This happens mainly because this method uses only three parameters on the evaluation, while DRASTIC uses seven. Although DRASTIC method presented more satisfactory results, the choice must be conditioned to data, human and financial resources availability. Both methods can be used in regional studies, but, the results showed in this paper must be used with caution in studies that requires higher levels of detail.
2

Avaliação da vulnerabilidade natural à contaminação do Sistema Aquífero Serra Geral do Paraná

Borges, Vinícius Menezes January 2017 (has links)
Este trabalho teve como objetivo avaliar a vulnerabilidade natural à contaminação do Sistema Aquífero Serra Geral (SASG) no estado do Paraná, bem como realizar uma comparação dos métodos DRASTIC e GOD, visando estabelecer vantagens e desvantagens da aplicação cada método. A vulnerabilidade natural à contaminação indica a sensibilidade à poluição de um aquífero a partir de suas características intrínsecas. Para que fosse realizada a avaliação da vulnerabilidade pelo método DRASTIC, foi necessária a estimativa das taxas de recarga das águas subterrâneas na área de estudo. Para isso, foram aplicados e comparados dois métodos: balanço hídrico e separação do escoamento de base. No método DRASTIC, adaptações foram feitas nos parâmetros A (Meio Aquífero), em que foi utilizada a densidade de lineamentos; I (Impacto da Zona Vadosa), em que foi avaliada a aptidão dos solos para disposição de resíduos sólidos; e C (Condutividade Hidráulica), em que foram utilizados valores de transmissividade. Estas adaptações tiveram como objetivo adequar o método à avaliação da vulnerabilidade em aquíferos fraturados. Os mapas de vulnerabilidade pelos métodos DRASTIC e GOD foram comparados através da normalização dos índices, visando inseri-los em um mesmo intervalo. Para a estimativa de recarga, os resultados apresentaram taxas média por bacia variando de 156 a 489 mm/ano pelo método da separação do escoamento de base e de 179 a 365 mm/ano pelo método do balanço hídrico. As diferenças apresentadas podem ser consideradas como aceitáveis, se considerados as diversas incertezas envolvidas no processo de estimativa de recarga e o fato de que os métodos utilizam dados diferentes na análise. Quanto ao mapeamento da vulnerabilidade natural à contaminação, o método DRASTIC apresentou graus de vulnerabilidade baixa (5,01%), moderada (83,13%) e elevada (11,85%). Já o método GOD apresentou vulnerabilidades baixa (66,21%), moderada (0,67%), alta (14,32%) e extrema (18,81%). As principais diferenças relativas entre os dois métodos ocorreram em locais onde a vulnerabilidade é determinada por parâmetros que não são mútuos dos métodos. De maneira geral, o método DRASTIC se mostrou mais restritivo quanto ao uso e ocupação do solo que o método GOD, pois apresentou índices mais elevados de vulnerabilidade quando considerada a área de estudo como um todo. O método DRASTIC apresentou maior grau de detalhe na avaliação e mais valores intermediários. Já o método GOD apresentou variação brusca dos índices em muitas regiões. Isso se deve principalmente ao fato de que este utiliza apenas três parâmetros em sua avaliação, enquanto o DRASTIC utiliza sete. Apesar do método DRASTIC apresentar resultados mais satisfatórios, a escolha do método deve estar condicionada à disponibilidade de dados e de recursos humanos e financeiros. Ambos os métodos podem ser utilizados em estudos regionais, entretanto, os resultados aqui obtidos devem ser utilizados com cautela em estudos que requerem maior grau de detalhe. / This paper aimed to evaluate natural vulnerability to contamination on Serra Geral Aquifer System (SASG) in Paraná state, Brazil, as well as comparing DRASTIC and GOD methods, aiming to stablish advantages and disadvantages of each method. Natural vulnerability to contamination indicates the sensibility to pollution of an aquifer considering its intrinsic characteristics. In order to carry out the evaluation through DRASTIC method, it was necessary to estimate groundwater recharge rates in the study area. To do so, two methods were applied and compared: baseflow separation and water balance. Concerning the DRASTIC method, some adaptations were made in the following parameters: A (Aquifer Media), in which was used lineaments density; I (Impact of Vadose Zone), in which was considered the soil capacity to receive solid waste; and C (Hydraulic Conductivity), in which was used aquifer transmissivity. These adaptations aimed to adapt the method for vulnerability evaluation on fractured aquifers. Vulnerability maps by DRASTIC and GOD were compared through index normalization, inserting them at the same interval. For recharge estimation, results showed average values per basin of 156 to 489 mm/year by baseflow separation and 179 to 365 mm/year by water balance. The differences can be considered as acceptable when considered the various uncertainties involved and the fact that the methods uses different data on the analysis. Concerning the natural vulnerability to contamination mapping, DRASTIC method showed the following levels of vulnerability: low (5,01%), moderate (83,13%) and high (11,85%). GOD method showed the following levels: low (66,21%), moderate (0,67%), high (14,32%) and extreme (18,81%). The main differences related to both methods occurred in areas where the vulnerability is determined by mutual parameters. In general, DRASTIC method showed to be more restrictive in terms of land use than GOD, as it presented high indexes when considered all the study area. DRASTIC method showed a higher level of spatial detail and more intermediary values. The GOD method showed abrupt variation of indexes in many areas. This happens mainly because this method uses only three parameters on the evaluation, while DRASTIC uses seven. Although DRASTIC method presented more satisfactory results, the choice must be conditioned to data, human and financial resources availability. Both methods can be used in regional studies, but, the results showed in this paper must be used with caution in studies that requires higher levels of detail.
3

Avaliação da vulnerabilidade natural à contaminação do Sistema Aquífero Serra Geral do Paraná

Borges, Vinícius Menezes January 2017 (has links)
Este trabalho teve como objetivo avaliar a vulnerabilidade natural à contaminação do Sistema Aquífero Serra Geral (SASG) no estado do Paraná, bem como realizar uma comparação dos métodos DRASTIC e GOD, visando estabelecer vantagens e desvantagens da aplicação cada método. A vulnerabilidade natural à contaminação indica a sensibilidade à poluição de um aquífero a partir de suas características intrínsecas. Para que fosse realizada a avaliação da vulnerabilidade pelo método DRASTIC, foi necessária a estimativa das taxas de recarga das águas subterrâneas na área de estudo. Para isso, foram aplicados e comparados dois métodos: balanço hídrico e separação do escoamento de base. No método DRASTIC, adaptações foram feitas nos parâmetros A (Meio Aquífero), em que foi utilizada a densidade de lineamentos; I (Impacto da Zona Vadosa), em que foi avaliada a aptidão dos solos para disposição de resíduos sólidos; e C (Condutividade Hidráulica), em que foram utilizados valores de transmissividade. Estas adaptações tiveram como objetivo adequar o método à avaliação da vulnerabilidade em aquíferos fraturados. Os mapas de vulnerabilidade pelos métodos DRASTIC e GOD foram comparados através da normalização dos índices, visando inseri-los em um mesmo intervalo. Para a estimativa de recarga, os resultados apresentaram taxas média por bacia variando de 156 a 489 mm/ano pelo método da separação do escoamento de base e de 179 a 365 mm/ano pelo método do balanço hídrico. As diferenças apresentadas podem ser consideradas como aceitáveis, se considerados as diversas incertezas envolvidas no processo de estimativa de recarga e o fato de que os métodos utilizam dados diferentes na análise. Quanto ao mapeamento da vulnerabilidade natural à contaminação, o método DRASTIC apresentou graus de vulnerabilidade baixa (5,01%), moderada (83,13%) e elevada (11,85%). Já o método GOD apresentou vulnerabilidades baixa (66,21%), moderada (0,67%), alta (14,32%) e extrema (18,81%). As principais diferenças relativas entre os dois métodos ocorreram em locais onde a vulnerabilidade é determinada por parâmetros que não são mútuos dos métodos. De maneira geral, o método DRASTIC se mostrou mais restritivo quanto ao uso e ocupação do solo que o método GOD, pois apresentou índices mais elevados de vulnerabilidade quando considerada a área de estudo como um todo. O método DRASTIC apresentou maior grau de detalhe na avaliação e mais valores intermediários. Já o método GOD apresentou variação brusca dos índices em muitas regiões. Isso se deve principalmente ao fato de que este utiliza apenas três parâmetros em sua avaliação, enquanto o DRASTIC utiliza sete. Apesar do método DRASTIC apresentar resultados mais satisfatórios, a escolha do método deve estar condicionada à disponibilidade de dados e de recursos humanos e financeiros. Ambos os métodos podem ser utilizados em estudos regionais, entretanto, os resultados aqui obtidos devem ser utilizados com cautela em estudos que requerem maior grau de detalhe. / This paper aimed to evaluate natural vulnerability to contamination on Serra Geral Aquifer System (SASG) in Paraná state, Brazil, as well as comparing DRASTIC and GOD methods, aiming to stablish advantages and disadvantages of each method. Natural vulnerability to contamination indicates the sensibility to pollution of an aquifer considering its intrinsic characteristics. In order to carry out the evaluation through DRASTIC method, it was necessary to estimate groundwater recharge rates in the study area. To do so, two methods were applied and compared: baseflow separation and water balance. Concerning the DRASTIC method, some adaptations were made in the following parameters: A (Aquifer Media), in which was used lineaments density; I (Impact of Vadose Zone), in which was considered the soil capacity to receive solid waste; and C (Hydraulic Conductivity), in which was used aquifer transmissivity. These adaptations aimed to adapt the method for vulnerability evaluation on fractured aquifers. Vulnerability maps by DRASTIC and GOD were compared through index normalization, inserting them at the same interval. For recharge estimation, results showed average values per basin of 156 to 489 mm/year by baseflow separation and 179 to 365 mm/year by water balance. The differences can be considered as acceptable when considered the various uncertainties involved and the fact that the methods uses different data on the analysis. Concerning the natural vulnerability to contamination mapping, DRASTIC method showed the following levels of vulnerability: low (5,01%), moderate (83,13%) and high (11,85%). GOD method showed the following levels: low (66,21%), moderate (0,67%), high (14,32%) and extreme (18,81%). The main differences related to both methods occurred in areas where the vulnerability is determined by mutual parameters. In general, DRASTIC method showed to be more restrictive in terms of land use than GOD, as it presented high indexes when considered all the study area. DRASTIC method showed a higher level of spatial detail and more intermediary values. The GOD method showed abrupt variation of indexes in many areas. This happens mainly because this method uses only three parameters on the evaluation, while DRASTIC uses seven. Although DRASTIC method presented more satisfactory results, the choice must be conditioned to data, human and financial resources availability. Both methods can be used in regional studies, but, the results showed in this paper must be used with caution in studies that requires higher levels of detail.
4

Interações entre as aguas superficiais e o Sistema Aquífero Serra Geral do Paraná 3, estado do Paraná

Melati, Maurício Dambrós January 2018 (has links)
Em regiões úmidas a relação entre os mananciais superficiais e subterrâneos se dá principalmente por meio da descarga dos aquíferos para os rios, essa dinâmica é “alimentada” principalmente pela recarga subterrânea. A área de estudo foi a Bacia do Paraná 3, localizada no Sistema Aquífero Serra Geral, no estado do Paraná. O presente trabalho estudou a recarga subterrânea em duas bacias monitoradas por estações fluviométricas a partir de três diferentes métodos, o balanço hídrico, a separação do escoamento de base usando três diferentes formas de obtenção do parâmetro BFImax (tabelado, curva de permanência e filtro inverso), e a modelagem hidrológica a partir da análise dos reservatórios subterrâneo e subsuperficial do modelo MGB-IPH. Para melhor entender as águas subterrâneas, também se utilizou o TWS do GRACE para avaliar as variações do armazenamento de água na área. Os resultados obtidos mostraram que a maioria dos métodos e suas variações convergiram em grandeza (resultados médio de 491,4±31,9mm para a bacia SFV e 270,1±39,4mm para a bacia SFF), com exceção dos resultados da aplicação da separação do escoamento de base usando o BFImax tabelado (212,0mm para a bacia SFV e 160,6mm para a bacia SFF), além disso, verificou-se que o uso do esvaziamento do reservatório subsuperficial e subterrâneo juntos (612,9±18,1mm para a bacia SFV e 372,8±25,2mm para a bacia SFF) apresenta resultados similares ao uso de filtros e ao balanço hídrico, entretanto, quando se utiliza somente o esvaziamento do reservatório subterrâneo (509,1±17,3mm para a bacia SFV e 53,5±9,7mm para a bacia SFF), somente uma estação converge em resultados, a outra apresenta valores bastante inferiores, esses resultados foram explicados pelas diferentes geomorfologias das bacias. Foi verificado que a aplicação dos filtros de separação do escoamento de base em dados simulados no modelo MGB-IPH não apresenta prejuízos em relação a aplicação dos mesmos em dados observados (<4%). A variação mensal da recarga subterrânea apresentou um comportamento concordante ao TWS do GRACE. Com os resultados obtidos um modelo hidrogeológico conceitual da área foi proposto com base nas características físicas (geomorfologia, solos, características hidráulicas e hidrológicas e dados dos poços) e com base nos resultados obtidos pela aplicação dos métodos de recarga subterrânea. O modelo mostrou que a existência de topos alongados e aplainados em regiões de baixa de declividade favorecem a recarga subterrânea frente a regiões sem topos aplainados e de maior declividade, além disso, a profundidade dos solos também explicou os resultados. / In humid regions, the relationship between groundwater sources and the rivers is mainly governed by the discharge of aquifers into rivers, this dynamics is fed mainly by groundwater recharge. The study area was the Paraná Basin 3, located in the Serra Geral Aquifer System, in the state of Paraná. The present work studied the groundwater recharge in two basins monitored by gauge stations using three different methods: the water-budget method, the hydrograph separation method using three different ways of obtaining the BFImax parameter (Eckhardt pre-defined values, Q90/Q50 ratio and backwards filter) and the hydrological modeling from the analysis of the groundwater and subsurface reservoirs of the MGB-IPH model. To better understand groundwater, TWS obtained from GRACE was also used to assess variations in water storage in the area. The results showed that most of the methods and their variations converged in magnitude (average of 491,4±31,9mm for SFV basin and 270,1±39,4mm for SFF basin), except for the results of the hydrograph separation using the Eckhardt pre-defined values of BFImax (212,0mm for SFV basin and 160,6mm for SFF basin), in addition, it was verified that the use of the emptying of the subsurface and groundwater reservoir together (612,9±18,1mm for SFV basin and 372,8±25,2mm for SFF basin) presents results similar to the use of hydrograph separation and to the water-budget method, however, when only the emptying of the groundwater reservoir is used (509,1±17,3mm for SFV basin and 53,5±9,7mm for SFF basin), only one station converged in results, the other presented lower values, these results were explained by the different geomorphologies of the basins. It was verified that the application of the hydrograph separation in simulated data does not present damages in relation to the application of the same in observed data (<4%). The monthly variation of the groundwater recharge presented a concordant behavior to the TWS. With the results obtained a conceptual hydrogeological model of the area was proposed based on the physical characteristics (geomorphology, soils, hydraulic and hydrological characteristics and hydrodynamic characteristics of the wells) and based on the results obtained by the application of groundwater recharge methods. The model showed that the existence of elongated and flattened tops in low declivity regions favors groundwater recharge compared to regions with no flattened tops and with greater declivity, in addition, soil depth also influenced the results.
5

Interações entre as aguas superficiais e o Sistema Aquífero Serra Geral do Paraná 3, estado do Paraná

Melati, Maurício Dambrós January 2018 (has links)
Em regiões úmidas a relação entre os mananciais superficiais e subterrâneos se dá principalmente por meio da descarga dos aquíferos para os rios, essa dinâmica é “alimentada” principalmente pela recarga subterrânea. A área de estudo foi a Bacia do Paraná 3, localizada no Sistema Aquífero Serra Geral, no estado do Paraná. O presente trabalho estudou a recarga subterrânea em duas bacias monitoradas por estações fluviométricas a partir de três diferentes métodos, o balanço hídrico, a separação do escoamento de base usando três diferentes formas de obtenção do parâmetro BFImax (tabelado, curva de permanência e filtro inverso), e a modelagem hidrológica a partir da análise dos reservatórios subterrâneo e subsuperficial do modelo MGB-IPH. Para melhor entender as águas subterrâneas, também se utilizou o TWS do GRACE para avaliar as variações do armazenamento de água na área. Os resultados obtidos mostraram que a maioria dos métodos e suas variações convergiram em grandeza (resultados médio de 491,4±31,9mm para a bacia SFV e 270,1±39,4mm para a bacia SFF), com exceção dos resultados da aplicação da separação do escoamento de base usando o BFImax tabelado (212,0mm para a bacia SFV e 160,6mm para a bacia SFF), além disso, verificou-se que o uso do esvaziamento do reservatório subsuperficial e subterrâneo juntos (612,9±18,1mm para a bacia SFV e 372,8±25,2mm para a bacia SFF) apresenta resultados similares ao uso de filtros e ao balanço hídrico, entretanto, quando se utiliza somente o esvaziamento do reservatório subterrâneo (509,1±17,3mm para a bacia SFV e 53,5±9,7mm para a bacia SFF), somente uma estação converge em resultados, a outra apresenta valores bastante inferiores, esses resultados foram explicados pelas diferentes geomorfologias das bacias. Foi verificado que a aplicação dos filtros de separação do escoamento de base em dados simulados no modelo MGB-IPH não apresenta prejuízos em relação a aplicação dos mesmos em dados observados (<4%). A variação mensal da recarga subterrânea apresentou um comportamento concordante ao TWS do GRACE. Com os resultados obtidos um modelo hidrogeológico conceitual da área foi proposto com base nas características físicas (geomorfologia, solos, características hidráulicas e hidrológicas e dados dos poços) e com base nos resultados obtidos pela aplicação dos métodos de recarga subterrânea. O modelo mostrou que a existência de topos alongados e aplainados em regiões de baixa de declividade favorecem a recarga subterrânea frente a regiões sem topos aplainados e de maior declividade, além disso, a profundidade dos solos também explicou os resultados. / In humid regions, the relationship between groundwater sources and the rivers is mainly governed by the discharge of aquifers into rivers, this dynamics is fed mainly by groundwater recharge. The study area was the Paraná Basin 3, located in the Serra Geral Aquifer System, in the state of Paraná. The present work studied the groundwater recharge in two basins monitored by gauge stations using three different methods: the water-budget method, the hydrograph separation method using three different ways of obtaining the BFImax parameter (Eckhardt pre-defined values, Q90/Q50 ratio and backwards filter) and the hydrological modeling from the analysis of the groundwater and subsurface reservoirs of the MGB-IPH model. To better understand groundwater, TWS obtained from GRACE was also used to assess variations in water storage in the area. The results showed that most of the methods and their variations converged in magnitude (average of 491,4±31,9mm for SFV basin and 270,1±39,4mm for SFF basin), except for the results of the hydrograph separation using the Eckhardt pre-defined values of BFImax (212,0mm for SFV basin and 160,6mm for SFF basin), in addition, it was verified that the use of the emptying of the subsurface and groundwater reservoir together (612,9±18,1mm for SFV basin and 372,8±25,2mm for SFF basin) presents results similar to the use of hydrograph separation and to the water-budget method, however, when only the emptying of the groundwater reservoir is used (509,1±17,3mm for SFV basin and 53,5±9,7mm for SFF basin), only one station converged in results, the other presented lower values, these results were explained by the different geomorphologies of the basins. It was verified that the application of the hydrograph separation in simulated data does not present damages in relation to the application of the same in observed data (<4%). The monthly variation of the groundwater recharge presented a concordant behavior to the TWS. With the results obtained a conceptual hydrogeological model of the area was proposed based on the physical characteristics (geomorphology, soils, hydraulic and hydrological characteristics and hydrodynamic characteristics of the wells) and based on the results obtained by the application of groundwater recharge methods. The model showed that the existence of elongated and flattened tops in low declivity regions favors groundwater recharge compared to regions with no flattened tops and with greater declivity, in addition, soil depth also influenced the results.
6

Interações entre as aguas superficiais e o Sistema Aquífero Serra Geral do Paraná 3, estado do Paraná

Melati, Maurício Dambrós January 2018 (has links)
Em regiões úmidas a relação entre os mananciais superficiais e subterrâneos se dá principalmente por meio da descarga dos aquíferos para os rios, essa dinâmica é “alimentada” principalmente pela recarga subterrânea. A área de estudo foi a Bacia do Paraná 3, localizada no Sistema Aquífero Serra Geral, no estado do Paraná. O presente trabalho estudou a recarga subterrânea em duas bacias monitoradas por estações fluviométricas a partir de três diferentes métodos, o balanço hídrico, a separação do escoamento de base usando três diferentes formas de obtenção do parâmetro BFImax (tabelado, curva de permanência e filtro inverso), e a modelagem hidrológica a partir da análise dos reservatórios subterrâneo e subsuperficial do modelo MGB-IPH. Para melhor entender as águas subterrâneas, também se utilizou o TWS do GRACE para avaliar as variações do armazenamento de água na área. Os resultados obtidos mostraram que a maioria dos métodos e suas variações convergiram em grandeza (resultados médio de 491,4±31,9mm para a bacia SFV e 270,1±39,4mm para a bacia SFF), com exceção dos resultados da aplicação da separação do escoamento de base usando o BFImax tabelado (212,0mm para a bacia SFV e 160,6mm para a bacia SFF), além disso, verificou-se que o uso do esvaziamento do reservatório subsuperficial e subterrâneo juntos (612,9±18,1mm para a bacia SFV e 372,8±25,2mm para a bacia SFF) apresenta resultados similares ao uso de filtros e ao balanço hídrico, entretanto, quando se utiliza somente o esvaziamento do reservatório subterrâneo (509,1±17,3mm para a bacia SFV e 53,5±9,7mm para a bacia SFF), somente uma estação converge em resultados, a outra apresenta valores bastante inferiores, esses resultados foram explicados pelas diferentes geomorfologias das bacias. Foi verificado que a aplicação dos filtros de separação do escoamento de base em dados simulados no modelo MGB-IPH não apresenta prejuízos em relação a aplicação dos mesmos em dados observados (<4%). A variação mensal da recarga subterrânea apresentou um comportamento concordante ao TWS do GRACE. Com os resultados obtidos um modelo hidrogeológico conceitual da área foi proposto com base nas características físicas (geomorfologia, solos, características hidráulicas e hidrológicas e dados dos poços) e com base nos resultados obtidos pela aplicação dos métodos de recarga subterrânea. O modelo mostrou que a existência de topos alongados e aplainados em regiões de baixa de declividade favorecem a recarga subterrânea frente a regiões sem topos aplainados e de maior declividade, além disso, a profundidade dos solos também explicou os resultados. / In humid regions, the relationship between groundwater sources and the rivers is mainly governed by the discharge of aquifers into rivers, this dynamics is fed mainly by groundwater recharge. The study area was the Paraná Basin 3, located in the Serra Geral Aquifer System, in the state of Paraná. The present work studied the groundwater recharge in two basins monitored by gauge stations using three different methods: the water-budget method, the hydrograph separation method using three different ways of obtaining the BFImax parameter (Eckhardt pre-defined values, Q90/Q50 ratio and backwards filter) and the hydrological modeling from the analysis of the groundwater and subsurface reservoirs of the MGB-IPH model. To better understand groundwater, TWS obtained from GRACE was also used to assess variations in water storage in the area. The results showed that most of the methods and their variations converged in magnitude (average of 491,4±31,9mm for SFV basin and 270,1±39,4mm for SFF basin), except for the results of the hydrograph separation using the Eckhardt pre-defined values of BFImax (212,0mm for SFV basin and 160,6mm for SFF basin), in addition, it was verified that the use of the emptying of the subsurface and groundwater reservoir together (612,9±18,1mm for SFV basin and 372,8±25,2mm for SFF basin) presents results similar to the use of hydrograph separation and to the water-budget method, however, when only the emptying of the groundwater reservoir is used (509,1±17,3mm for SFV basin and 53,5±9,7mm for SFF basin), only one station converged in results, the other presented lower values, these results were explained by the different geomorphologies of the basins. It was verified that the application of the hydrograph separation in simulated data does not present damages in relation to the application of the same in observed data (<4%). The monthly variation of the groundwater recharge presented a concordant behavior to the TWS. With the results obtained a conceptual hydrogeological model of the area was proposed based on the physical characteristics (geomorphology, soils, hydraulic and hydrological characteristics and hydrodynamic characteristics of the wells) and based on the results obtained by the application of groundwater recharge methods. The model showed that the existence of elongated and flattened tops in low declivity regions favors groundwater recharge compared to regions with no flattened tops and with greater declivity, in addition, soil depth also influenced the results.

Page generated in 0.0428 seconds