• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ferramenta para maximização de carga na fase fluente de recomposição de sistemas elétricos

Viana, Eduardo Martins 13 August 2008 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-24T13:25:57Z No. of bitstreams: 1 eduardomartinsviana.pdf: 1013683 bytes, checksum: 5d87e6aef68844b7f67e1941a0337702 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-24T16:55:49Z (GMT) No. of bitstreams: 1 eduardomartinsviana.pdf: 1013683 bytes, checksum: 5d87e6aef68844b7f67e1941a0337702 (MD5) / Made available in DSpace on 2017-04-24T16:55:49Z (GMT). No. of bitstreams: 1 eduardomartinsviana.pdf: 1013683 bytes, checksum: 5d87e6aef68844b7f67e1941a0337702 (MD5) Previous issue date: 2008-08-13 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho propõe uma metodologia para auxiliar os estudos relacionados à recomposição fluente de sistemas elétricos de potência. Nesta fase inicial de recomposição, o sistema de potência encontra-se estruturado em longos corredores de transmissão e a definição de uma configuração de reatores constitui uma das estratégias adotadas para a eliminação de sobretensões. A ferramenta proposta, baseada em um modelo de otimização, visa o estabelecimento de procedimentos de rede que conduza a uma configuração mínima de reatores conectados ao sistema e a máxima tomada de carga durante esta fase de recomposição. Os diversos cenários de recomposição fluente, correspondentes à energização de novos trechos de linhas de transmissão, são representados através de subproblemas. A técnica de decomposição de Benders associada à metodologia primal-dual de pontos interiores é utilizada para solução do problema de otimização não-linear proposto. São realizados estudos de caso em ramos de recomposição fluente do Sistema Elétrico Brasileiro interligado para verificar a eficácia da metodologia. Os resultados obtidos são comparados com outros métodos propostos na literatura. / This work proposes a methodology to help the studies related to electric power systems fluent restoration. At this early restoration stage, power system is structured in long transmission corridors and the reactors set definition is one of the adopted strategies for overvoltages disposal. The proposed tool, based on an optimization model, aims the network procedures establishment leading to a minimum reactors configuration connected to the system and maximum load pick-up during this restoration phase. The various fluent restoration scenarios, corresponding to new transmission lines sections inrush, are represented by sub problems. Benders decomposition technique associated to primal-dual interior points methodology is used to solve the proposed nonlinear optimization problem. Case studies are conducted in fluent restoration branches of Brazilian Electric interconnected System to verify the methodology effectiveness. The results are compared with other proposed methods in the literature.
2

Contribuições ao estudo de recomposição fluente de sistemas elétricos de potência / Contributions to study of electrical power systems fluent restoration

Peres, Wesley 05 March 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-06-09T11:56:03Z No. of bitstreams: 1 wesleyperes.pdf: 1629298 bytes, checksum: 979f44672c05a9876154ebaff4efaf74 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T13:30:59Z (GMT) No. of bitstreams: 1 wesleyperes.pdf: 1629298 bytes, checksum: 979f44672c05a9876154ebaff4efaf74 (MD5) / Made available in DSpace on 2016-07-13T13:30:59Z (GMT). No. of bitstreams: 1 wesleyperes.pdf: 1629298 bytes, checksum: 979f44672c05a9876154ebaff4efaf74 (MD5) Previous issue date: 2012-03-05 / Este trabalho apresenta uma metodologia baseada em Fluxo de Potência Ótimo (FPO) e Análise de Sensibilidade para a definição da configuração mínima de rede necessária para garantir, com segurança, o processo de recomposição fluente de corredores radiais de transmissão. Nos instantes iniciais de recomposição, devido à baixa capacidade de geração que o sistema se encontra, uma estratégia importante consiste em elevar a Capacidade de Curto Circuito das barras. Neste sentido, a metodologia proposta baseia-se na incorporação, na função objetivo do FPO, da maximização da potência de curto circuito das barras. Para tanto, uma Análise de Sensibilidade é realizada a cada iteração do processo iterativo para determinar os fatores de ponderação de alocação associados à impedância equivalente permitindo a inclusão no FPO da maximização da potência de curto circuito das barras. Na metodologia proposta os reatores que mais reduzirem a impedância receberão menores fatores de ponderação de alocação. Adicionalmente, o FPO contempla a modelagem das máquinas síncronas, curva de capabilidade e o estudo de cada cenário de recomposição em regime permanente, pré e pós rejeição de carga. O programa desenvolvido em MATLAB é utilizado para a simulação de corredores de recomposição fluente do sistema elétrico brasileiro. Os resultados obtidos apontam para uma ferramenta eficaz ao estudo de recomposição fluente. / This work presents a methodology based on Optimal Power Flow (OPF) and Sensitivity Analysis to define a minimum network configuration for a power system fluent restoration taking security issues into account. At this early restoration stage, the system has low Short-Circuit Capacity due to the low generation capacity. An important strategy is to increase the Short Circuit Capacity at this operation stage through search network configurations with low bus equivalent impedance. In this work, the Short-Circuit Capacity is incorporated in the objective function of the OPF formulation by using sensitivity analysis which yields lowest allocation factors for more suitable reactors to reduce the equivalents impedances. The proposed OPF takes into account the synchronous machine model, the capability curves and the set of overvoltage critical restoration scenarios following load rejection. The restoration scenarios are represented at steady state prior and after load rejection. The computational tool is developed in the MATLAB platform and it is used to conduct case studies for fluent restoration branches of Brazilian Electric System. The results show that the proposed methodology is effective.

Page generated in 0.1109 seconds