1

Gestão de perdas em redes de abastecimento de água - assistida pelo simulador EPANET

Moreira, Tiago Orlando Morais January 2011 (has links)
Tese de mestrado integrado. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 2011
2

Detecção de vazamentos em redes sob pressão baseada na análise dos sinais de pressão e vazão com um sistema de reconhecimento de padrões / Leak detection in water networks based on the analysis of flow and pressure signals by a pattern recognition system

Gamboa Medina, Maria Mercedes 29 July 2013 (has links)
O controle de perdas em sistemas de distribuição de água para abastecimento é uma preocupação constante, e uma tarefa fundamental para a solução do problema é a detecção rápida e confiável dos vazamentos que frequentemente iniciam em qualquer ponto da rede. Uma abordagem promissória é a detecção de vazamentos baseada na análise de sinais adquiridos pelo monitoramento das redes durante sua operação, e dentro dela se enquadra este trabalho. É desenvolvido um sistema de reconhecimento de padrões para análise de sinais de pressão e vazão que permite identificar se durante a aquisição do sinal aconteceu um vazamento ou não. Para a conformação desse sistema diversas técnicas são exploradas, incluindo a extração de características no domínio do tempo (energia, entropia, número de cruzamentos por zero) e na decomposição wavelet (distribuição da energia nas componentes). Também é explorado o uso de algoritmos para classificação de diferentes tipos (vizinhos mais próximos, árvore de decisão, regra de decisão, Naive Bayes, máquina de vetor suporte e rede neural artificial com funções de base radial). Sinais são adquiridos junto ao circuito hidráulico experimental, que permitiu a simulação da ocorrência de um vazamento na rede, para constituir uma amplia base de dados com sinais de exemplo. Além da revisão bibliográfica e os conceitos relativos às metodologias exploradas, são apresentadas neste documento as análises que conduzem à criação do sistema de reconhecimento de padrões mais apropriado para o problema. Das análises dos diferentes métodos considerados é definido o sistema de reconhecimento de padrões, em suas etapas de segmentação e padronização, extração de características e classificação. A avaliação do sistema proposto mostra um desempenho totalmente satisfatório, com reconhecimento acertado de sinais vinculados ou não a um vazamento em mais de 95% dos testes. / Control of losses in water supply systems is a constant concern, and a key to the solution of this problem is the rapid and reliable detection of leaks that often begin anywhere on the network. A promising approach to solve the problem is the leak detection based on the analysis of signals acquired by monitoring the network in operation, and this research fits with that approach. Its developed a pattern recognition system for the analysis of pressure and flow signals, which identifies whether a leak happened during signal acquisition. Several techniques are exploited for forming this system, including the feature extraction in the time domain (energy, entropy, zero crossings count) and in the wavelet decomposition (energy distribution in the components). Also, the use of different types of algorithms for classification (nearest neighbors, decision tree, decision rule, Naive Bayes, support vector machine and artificial neural network with radial basis functions) is explored. Signals are acquired from the experimental hydraulic circuit, allowing the simulation of the onset of a leak in the network, to form a big database of example signals. Besides the literature review and the concepts relating to the considered methods, in this document are shown the analyses leading to the creation of the pattern recognition system most appropriate for the problem. The analysis of the methods considered allows defining the pattern recognition system, which is composed by segmentation and standardization, feature extraction and classification. The evaluation of the proposed system shows a completely satisfactory performance, recognizing rightly the signals as linked or not to a leak in more than 95% of the tests.
3

Detecção de vazamentos em redes sob pressão baseada na análise dos sinais de pressão e vazão com um sistema de reconhecimento de padrões / Leak detection in water networks based on the analysis of flow and pressure signals by a pattern recognition system

Maria Mercedes Gamboa Medina 29 July 2013 (has links)
O controle de perdas em sistemas de distribuição de água para abastecimento é uma preocupação constante, e uma tarefa fundamental para a solução do problema é a detecção rápida e confiável dos vazamentos que frequentemente iniciam em qualquer ponto da rede. Uma abordagem promissória é a detecção de vazamentos baseada na análise de sinais adquiridos pelo monitoramento das redes durante sua operação, e dentro dela se enquadra este trabalho. É desenvolvido um sistema de reconhecimento de padrões para análise de sinais de pressão e vazão que permite identificar se durante a aquisição do sinal aconteceu um vazamento ou não. Para a conformação desse sistema diversas técnicas são exploradas, incluindo a extração de características no domínio do tempo (energia, entropia, número de cruzamentos por zero) e na decomposição wavelet (distribuição da energia nas componentes). Também é explorado o uso de algoritmos para classificação de diferentes tipos (vizinhos mais próximos, árvore de decisão, regra de decisão, Naive Bayes, máquina de vetor suporte e rede neural artificial com funções de base radial). Sinais são adquiridos junto ao circuito hidráulico experimental, que permitiu a simulação da ocorrência de um vazamento na rede, para constituir uma amplia base de dados com sinais de exemplo. Além da revisão bibliográfica e os conceitos relativos às metodologias exploradas, são apresentadas neste documento as análises que conduzem à criação do sistema de reconhecimento de padrões mais apropriado para o problema. Das análises dos diferentes métodos considerados é definido o sistema de reconhecimento de padrões, em suas etapas de segmentação e padronização, extração de características e classificação. A avaliação do sistema proposto mostra um desempenho totalmente satisfatório, com reconhecimento acertado de sinais vinculados ou não a um vazamento em mais de 95% dos testes. / Control of losses in water supply systems is a constant concern, and a key to the solution of this problem is the rapid and reliable detection of leaks that often begin anywhere on the network. A promising approach to solve the problem is the leak detection based on the analysis of signals acquired by monitoring the network in operation, and this research fits with that approach. Its developed a pattern recognition system for the analysis of pressure and flow signals, which identifies whether a leak happened during signal acquisition. Several techniques are exploited for forming this system, including the feature extraction in the time domain (energy, entropy, zero crossings count) and in the wavelet decomposition (energy distribution in the components). Also, the use of different types of algorithms for classification (nearest neighbors, decision tree, decision rule, Naive Bayes, support vector machine and artificial neural network with radial basis functions) is explored. Signals are acquired from the experimental hydraulic circuit, allowing the simulation of the onset of a leak in the network, to form a big database of example signals. Besides the literature review and the concepts relating to the considered methods, in this document are shown the analyses leading to the creation of the pattern recognition system most appropriate for the problem. The analysis of the methods considered allows defining the pattern recognition system, which is composed by segmentation and standardization, feature extraction and classification. The evaluation of the proposed system shows a completely satisfactory performance, recognizing rightly the signals as linked or not to a leak in more than 95% of the tests.
4

Decaimento da concentração de cloro residual livre nas redes de abastecimento de água / Determination of concentration of free residual chlorine in water supply networks

Oliveira, Luciano de 13 July 2018 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2018-08-13T11:23:42Z No. of bitstreams: 2 Dissertação - Luciano de Oliveira - 2018.pdf: 5027134 bytes, checksum: a0469fdd822b10eda9e451f4b9c889b2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-08-13T11:51:19Z (GMT) No. of bitstreams: 2 Dissertação - Luciano de Oliveira - 2018.pdf: 5027134 bytes, checksum: a0469fdd822b10eda9e451f4b9c889b2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-08-13T11:51:19Z (GMT). No. of bitstreams: 2 Dissertação - Luciano de Oliveira - 2018.pdf: 5027134 bytes, checksum: a0469fdd822b10eda9e451f4b9c889b2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-07-13 / The chlorination process is the most used to promote disinfection of water intended for human consumption. During the course of chlorinated water in the supply systems, the concentration of free residual chlorine (FRC), whose reaction rate depends on the characteristics of the natural water, occurs. In this work, we studied the decay of the FRC concentration related to the reactions in the liquid mass in two types of water, of subterranean and superficial origin, with different concentrations of organic matter, with the perspective of the influence of the water travel time, dependent on consumption scenarios in real distribution networks, whose supply modules are characterized by low population density and that operate under the initial demand conditions predicted in the projects. The effect of temperature and total organic carbon on the values of mass decay kinetic constants (k b ), used in mathematical models that simulate water quality, was considered. The results showed that the variation of the kb values is directly proportional to the water temperature and the TOC. For initial concentrations close to 1.00 mg.L -1 , the values of the kinetic constants for waters from surface water sources maintained in the temperature ranges of 20 to 21 °C and 30 to 31 °C were respectively 0.0888 day -1 and 0.1200 day -1 for samples collected at the ETA filter output of the DAIAsystem and TOC value of 0.4798 mg.L -1 and equal to and 0.1680 day -1 and 0.3024 day -1 for the samples collected at the filter outputs of the Piancó and TOC system ETA of 0.8750 mg.L - . In samples of groundwater with TOC of 0.1740 mg.L -1 , maintained at the same temperature 1 ranges, the kinetic coefficients were 0.0264 day -1 and 0.0480 day -1 , respectively. Experiments for temperature between 30 and 31 °C and near test duration showed a significant difference in chlorine decay behavior in filtered water samples collected at conventional treatment plants, which showed a residual chlorine loss percentage of 64.81% in relation to the initial concentration of 1.08 mg.L -1 of disinfectant (ETA DAIA) and 33.65% in relation to the initial concentration of 1.05 mg.L -1 of disinfectant (ETA Piancó). Raw water samples from the underground spring lost 14.33% of the initial concentration of 1.04 mg.L -1 . The travel times for the most critical nodes and the minimum disinfectant concentrations at the entrance of the supply modules to comply with the legislation were 40 hours and 0.27-0.28 mg.L -1 for the distribution networks of the condominium Valley of the Birds and 144 hours and 0.30-0.36 mg.L -1 for the condominium Terras Alphaville. / O processo de cloração é o mais utilizado para promover a desinfecção das águas destinadas ao consumo humano. Durante o percurso da água clorada nos sistemas de abastecimento ocorre o decaimento da concentração do cloro residual livre (CRL), cuja taxa de reação depende das características da água natural. Neste trabalho estudou-se o decaimento da concentração do CRL relacionado às reações na massa líquida em dois tipos de águas, de origem subterrânea e superficial, com diferentes concentrações de matéria orgânica, com aperspectiva da influência do tempo de percurso da água, dependente de cenários de consumo em redes de distribuição reais, cujos módulos de abastecimento são caracterizados pelo baixo adensamento populacional e que operam nas condições iniciais de demanda previstas nos projetos. Considerou-se o efeito da temperatura e do carbono orgânico total sobre os valores das constantes cinéticas de decaimento em massa (k b ), utilizadas nos modelos matemáticos que simulam a qualidade da água. Os resultados mostraram que a variação dos valores de k b é diretamente proporcional à temperatura da água e ao COT. Para concentrações iniciais próximas a 1,00 mg.L -1 os valores das constantes cinéticas, para águas provenientes de mananciais superficiais mantidas nas faixas de temperatura de foram, respectivamente, iguais a 0,0888 20 a 21 °C e 30 a 31 °C, dia -1 e 0,1200 dia -1 para amostras coletas na saída do filtro da ETA do sistema DAIA e valor de COT de 0,4798 mg.L -1 e iguais a e 0,1680 dia -1 e 0,3024 dia -1 para as amostras coletas na saídas do filtro da ETA do sistema Piancó e COT de 0,8750 mg.L -1 . Em amostras de água subterrânea com COT de 0,1740 mg.L -1 , mantidas nas mesmas faixas de temperatura, os coeficientes cinéticos foram iguais a 0,0264 dia -1 e 0,0480 dia -1 , respectivamente. Os experimentos para temperatura entre 30 e 31 °C e tempos próximos de duração dos testes demonstraram diferença significativa no comportamento do decaimento do cloro em amostras de água filtrada coletadas nas estações de tratamento convencional que apresentaram porcentagem de perda de cloro residual de 64,81 % em relação à concentração inicial de 1,08 mg.L -1 de desinfetante (ETA DAIA) e 33,65 % em relação à concentração inicial de 1,05 mg.L -1 de desinfetante (ETA Piancó). Amostras de água bruta do manancial subterrâneo perderam 14,33 % da concentração inicial de 1,04 mg.L -1 . Os tempos de percurso para os nós mais críticos e as concentrações mínimas de desinfetante na entrada dos módulo de abastecimento para atendimento à legislação foram iguais a 40 horas e 0,27-0,28 mg.L -1 para as redes de distribuição do condomínio Vale dos Pássaros e 144 horas e 0,30-0,36 mg.L -1 para o condomínio Terras Alphaville.
5

Detecção de vazamentos e alterações em redes de distribuição de água para abastecimento, durante a operação, usando sinais de pressão / Leak and anomaly detection on water supply networks, while operating, using pressure signals

Maria Mercedes Gamboa Medina 16 August 2017 (has links)
O controle ativo de vazamentos é fundamental para o gerenciamento dos recursos hídricos, e particularmente o problema de sua detecção precisa de alternativas de solução. Nesta pesquisa foram desenvolvidos três métodos para detecção da ocorrência de vazamentos ou outras alterações em redes de distribuição de água para abastecimento, durante operação, com base na análise dos sinais de pressão adquiridos por monitoramento permanente na rede. Os métodos foram desenvolvidos com informações de um estudo de caso real, e fundamentam-se em cadeias de Markov, em controle estatístico de processos, e em comparação com padrões, respetivamente. Seu desempenho global foi quantificado com a área abaixo da curva ROC, obtendo valores médios de 0,67, 0,65 e 0,71, respetivamente. Foi encontrado que a ocorrência de vazamentos produz mudanças nas pressões medidas na rede, mas tais mudanças podem ser próximas às que acontecem pela operação normal, de forma que os métodos propostos constituem ferramentas de suporte ao gerenciamento úteis, sem atingir a detecção e diferenciação da totalidade dos vazamentos e alterações. / Active leak control is fundamental on water resources managment, and particullary the detection problem needs alternative solutions. On this research three methods for leak or anomaly detection on operating supply systems were developed, based on analisys of pressure signals acquired by network monitoring. The proposed methods used real data from a case study, and are based on Markov chains, statistical process control, and pattern comparison, respectively. Their overall performances on case study were measured using the area under ROC curve, reaching averages 0,67, 0,65 and 0,71, respectively. It was found that a leak onset result in disturbances on measured preassure, but sometimes those disturbances are close to those of normal operation, therefore proposed methods are useful decision tools, not reaching detection and distinction for all the leaks or anomalies.
6

Detecção de vazamentos e alterações em redes de distribuição de água para abastecimento, durante a operação, usando sinais de pressão / Leak and anomaly detection on water supply networks, while operating, using pressure signals

Gamboa Medina, Maria Mercedes 16 August 2017 (has links)
O controle ativo de vazamentos é fundamental para o gerenciamento dos recursos hídricos, e particularmente o problema de sua detecção precisa de alternativas de solução. Nesta pesquisa foram desenvolvidos três métodos para detecção da ocorrência de vazamentos ou outras alterações em redes de distribuição de água para abastecimento, durante operação, com base na análise dos sinais de pressão adquiridos por monitoramento permanente na rede. Os métodos foram desenvolvidos com informações de um estudo de caso real, e fundamentam-se em cadeias de Markov, em controle estatístico de processos, e em comparação com padrões, respetivamente. Seu desempenho global foi quantificado com a área abaixo da curva ROC, obtendo valores médios de 0,67, 0,65 e 0,71, respetivamente. Foi encontrado que a ocorrência de vazamentos produz mudanças nas pressões medidas na rede, mas tais mudanças podem ser próximas às que acontecem pela operação normal, de forma que os métodos propostos constituem ferramentas de suporte ao gerenciamento úteis, sem atingir a detecção e diferenciação da totalidade dos vazamentos e alterações. / Active leak control is fundamental on water resources managment, and particullary the detection problem needs alternative solutions. On this research three methods for leak or anomaly detection on operating supply systems were developed, based on analisys of pressure signals acquired by network monitoring. The proposed methods used real data from a case study, and are based on Markov chains, statistical process control, and pattern comparison, respectively. Their overall performances on case study were measured using the area under ROC curve, reaching averages 0,67, 0,65 and 0,71, respectively. It was found that a leak onset result in disturbances on measured preassure, but sometimes those disturbances are close to those of normal operation, therefore proposed methods are useful decision tools, not reaching detection and distinction for all the leaks or anomalies.