• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Techniques adaptatives pour l'imagerie par résonance magnétique des organes en mouvement / Adaptive Technics for Magnetic Resonance Imaging of Organs in Motion

Fernandez, Brice 12 November 2010 (has links)
L'imagerie par résonance magnétique (IRM) est un outil remarquable pour le diagnostic clinique, aussi bien pour l'imagerie cérébrale que pour l'imagerie cardiaque et abdominale. En IRM cardiaque, deux problèmes sont récurrents : la non reproductibilité des cycles cardiaques et le mouvement respiratoire. L'IRM cardiaque morphologique est généralement faite avec une séquence composée d'une préparation longue, visant à annuler le signal du sang pour accentuer le contraste au niveau du myocarde, et de l?acquisition à proprement parler. Ces acquisitions sont généralement faites en mésodiastole (phase de relaxation passive du coeur) ce qui permet de satisfaire les contraintes liées à l'annulation du sang et d'éviter les problèmes liés aux non reproductibilités des cycles cardiaques car la mésodiastole est longue. Il est donc difficile de satisfaire les contraintes liées à l?annulation du sang pour faire les acquisitions en télésystole (phase où le coeur est contracté) à cause des non reproductibilités cardiaques car la télésystole est courte. Afin de passer outre ces limitations et de pouvoir acquérir ces mêmes images morphologiques en télésystole, nous proposons une nouvelle méthode adaptative qui permet à la fois de placer la fenêtre d'acquisition de manière optimale et de satisfaire les contraintes liées à l'annulation du sang. Une application de cette méthode a également été mise en place pour estimer et comparer les temps de relaxation transversale (T2) entre télésystole et mésodiastole. Pour la gestion prospective du mouvement respiratoire, le point crucial est d'estimer les mouvements en temps réel en perturbant au minimum les signaux de résonance magnétique. Pour ce faire nous proposons une méthode basée sur l'estimation paramétrique des mouvements en temps réel à partir des signaux physiologiques disponibles (ceintures respiratoires et ECG). Cette méthode a été testée et les résultats montrent son intérêt et sa fiabilité par rapport aux erreurs faites au niveau du mouvement. Une méthode de reconstruction incluant les mouvements a également été utilisée pendant ces travaux afin de faire de l'imagerie en télésystole en respiration libre et d'utiliser d'autres types de capteurs respiratoires comme certains signaux de résonance magnétique. Ainsi pendant ces travaux, des méthodes adaptatives ont été mises en place afin de mieux gérer le mouvement et de prendre en compte les spécificités de chaque patient. Ces travaux ouvrent la voie de l'imagerie par résonance magnétique adaptative pleinement fonctionnelle dans un contexte clinique / Magnetic resonance imaging (MRI) is a valuable tool for the clinical diagnosis for brain imaging as well as cardiac and abdominal imaging. In cardiac MRI, there are two challenging issues: the non reproducibility of cardiac cycles and respiratory motion. Morphological cardiac MRI is generally performed with a pulse sequence composed of a long preparation, to cancel the blood signal and thus enhance the contrast of the myocardium, and the acquisition itself. These acquisitions are performed during the mid-diastolic rest (relaxation period of the heart) to satisfy constraints to cancel the blood signal and to avoid problems linked to the cardiac non reproducibility because the mid-diastolic rest is long. Consequently, to acquire images in end-systolic rest (when the heart is fully contracted) while taking into account constraints to cancel the blood signal is not straight forward due to cardiac non reproducibility because the end-systolic rest is short. To overcome these limitations and to acquire images in end-systolic rest, a new adaptive method is introduced that allows to optimally placing acquisition windows while taking constraint for the cancellation of the blood signal into account. This method was applied to measure and compare transverse relaxation time (T2) between end-systolic and mid-diastolic rests. For prospective respiratory motion correction, the crucial point is to estimate motion in real-time without perturbing MR signal used for imaging. In order to solve this issue, a new method is introduced aiming at estimating motion parameters in real-time based on physiological signals such as respiratory bellows and ECG. This method is evaluated and results show its interest and its reliability regarding motion estimation errors. A reconstructions algorithm is also used in order to perform cardiac imaging during the end-systolic rest in free breathing and to use different kind of respiratory motion sensors such as MR signals. Hence, during this research work, several adaptive method were developed to get a better management of motion and to take into account specificity of each patient. These works open the way of fully functional adaptive magnetic resonance imaging in a clinical situation
2

Propriétés magnétiques et optiques de monocristaux dopés terres rares pour l'information quantique

Marino, Robert 30 December 2011 (has links) (PDF)
La maitrise de l'information représente un avantage concurrentiel de nos jours. Malgré une intensification des moyens développés pour protéger les flux de données, il n'est actuellement pas possible d'échanger à distance et de façon complètement sure, une information entre deux interlocuteurs. Néanmoins, des travaux menés par Bennett et Brassard ont montré qu'il est possible d'atteindre un niveau de sécurité maximum en utilisant un protocole quantique de transmission de l'information. Ce protocole se base sur l'utilisation de réseaux télécom utilisant des répéteurs quantiques à la place des répéteurs classiques. La voie étudiée dans cette thèse, réalisée en partie dans le cadre du projet européen QuRep, a pour but l'amélioration des connaissances sur les monocristaux dopés aux ions de terre rare qui sont des candidats de choix pour la mise au point de répéteurs quantiques. Deux grands axes ont émergés : dans un premier temps nous avons essayé de comprendre quels sont les facteurs de succès et limitatifs dans l'utilisation du cristal de Nd : YSO en tant qu'hôte pour les mémoires quantiques avec pour objectif le transfert de la cohérence électronique vers des niveaux hyperfins. Dans un second temps, nous avons étudié un cristal présentant une structure hyperfine directement accessible en optique, Er : YLF afin de vérifier sa potentielle utilisation pour les mémoires quantiques. Ces travaux ont permis, entre autre, de réaliser un transfert de cohérence d'un niveau Zeeman électronique vers un niveau hyperfin avec un temps de stockage de plus de 300 μs, ce qui permet d'envisager une mémoire quantique dans Nd : YSO permettant de réémettre un photon à la demande

Page generated in 0.1078 seconds