• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo comparativo entre oito sistemas de lagoas de estabilização da região noroeste do Estado de São Paulo / Comparative study of eight systems of stabilization ponds in the northwestern region of São Paulo

Gomes, João Luiz Cais da Silva 10 April 2002 (has links)
Este trabalho comparou oito lagoas de estabilização da região Noroeste do Estado de São Paulo, que tratam esgotos predominantemente sanitários de Coroados, Lourdes, Planalto, Zacarias, Alto Alegre, Pongaí, Irapuã e Adolfo, cidades pequenas, com no máximo 5500 habitantes (1700 ligações), onde os quatro primeiros sistemas são compostos apenas por lagoas facultativas primárias e os quatro últimos por lagoas anaeróbias e lagoas facultativas secundárias. Vinte e cinco variáveis físicas, químicas e biológicas foram analisadas em amostras compostas coletadas entre 24/05/2000 e 03/10/2000. A análise da batimetria efetuada fornece indicações de prazos para a remoção do lodo do fundo das lagoas. As taxas de acúmulo de lodo médias obtidas para as lagoas anaeróbias e facultativas primárias foram de 0,07 e 0,14 m3/hab.ano, respectivamente. O pH do efluente das lagoas anaeróbias e das facultativas foi em média 6,6 e 7,4. Nas lagoas anaeróbias observou-se alta remoção de sólidos suspensos e de Demanda Bioquímica de Oxigênio (DBO) com eficiência geral média de 64% e 61% respectivamente. Os sistemas não atenderam plenamente à legislação no tocante a eficiência de remoção de DBO de 80%, porém o valor médio encontrado para os oito sistemas foi de 78%, bastante próximo do exigido. Sugere-se para a região, para eficiência de remoção de DBO de 80%, lagoas anaeróbias com tempo de detenção de 5 dias e para as lagoas facultativas primárias e secundárias tempos de detenção de 25 e 15 dias respectivamente, e taxas de aplicação superficial de 140 e 130 kg DBO/ha.dia, respectivamente. Não foi atingido o limite máximo de 1000 coliformes fecais por 100 ml, obtendo-se média geral de remoção de 97,40% inferindo-se que há necessidade de um processo de tratamento complementar para a remoção de microrganismos. Não observou-se correlação entre eficiência do sistema e relação comprimento/largura das lagoas. Constatou-se maus odores mesmo na ausência de concentrações detectáveis de sulfeto. A remoção média geral de amônio (NH4+), nitrogênio total, fosfato total dissolvido e fósforo total foi de 31%, 12%, 24% e 27% respectivamente nos sistemas estudados. / The present work compared the performance of eight stabilization ponds in the Northwest region of São Paulo state, that treat predominantly the domestic sewage from eight small cities with a maximum of 5000 inhabitants (1700 links): Coroados, Lourdes, Planalto, Zacarias, Alto Alegre, Pongaí, Trapuã and Adolfo. The first four systems are made of four primary facultative ponds and the last four by anaerobic ponds and secondary facultative ponds. A total of twenty-five chemical, physical and biological variables were analyzed in integrated samples collected between 24/05/2000 and 03/10/2000. The bathymetric analysis performed has indicated deadlines for sludge removal from the stabilization pond bottom. Mean sludge accumulation rates o btained for anaerobic and primary facultative ponds were 0.07 and 0.14 m3/inhabt.year, respectively. Effluents from anaerobic and facultative ponds had a mean pH of 6.6 and 7.4. In anaerobic ponds a righ rate of suspended solids removal was found and the Biochemical Oxygen Demand (BOD) had an overall general efficiency of 64% and 61%, respectively. The systems did not completely attend the present legislation in respect to a BOD removal of 80%, as required, however the mean value for the eight systems monitored was 78%, very close to the established limit. It is therefore suggested that for this region, in order to attain the removal efficiency of 80% anaerobic ponds should have a residence time of 5 days and the primary and secondary facultative ones should have residence times of 25 and 15 days respectively, coupled to loading rates of 140 and 170 Kg BOD/ha.day respectively. Also, the maximum limit of 1000 fecal coliforms per 100 ml was not reached, and in general there was a mean removal efficiency of 97.40%, indicating that an additional treatment process needs to be implemented for a successful removal of coliforms. No correlation was found between the removal efficiency and morphometry (length/weight) pond characteristics. Bad smell was present even in the absence of detectable amounts of sulfide. The mean efficiency for the removal of ammonium (NH4+), total nitrogen, total dissolved phosphorus and total phosphorus were 31%, 12%, 24%, and 27% respectively, among the systems studied.
2

Tratamento de efluente anaeróbio em lagoas de polimento com alimentação contínua e batelada

Pontes, Tatiana Gomes de 25 February 2016 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2016-05-12T12:58:24Z No. of bitstreams: 1 PDF - Tatiana Gomes de Pontes.pdf: 2313753 bytes, checksum: 8db271a02b37c7328dd7cd2c48e554d5 (MD5) / Made available in DSpace on 2016-05-12T12:58:24Z (GMT). No. of bitstreams: 1 PDF - Tatiana Gomes de Pontes.pdf: 2313753 bytes, checksum: 8db271a02b37c7328dd7cd2c48e554d5 (MD5) Previous issue date: 2016-02-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work represents the post-treatment of effluent reactor UASB in polishing ponds fed with continuous flow and batch investigating different depths, in two experimental phases. In the first phase of work, the experimental system consisted of four polishing ponds in which two were monitored with continuous feed (LC57 and LC45) and two with semi-continuous (LB57 and LB45) and its tributary coming from pond transshipment, both ponds LC57 and LB57 (57 cm deep), for the ponds LC45 and LB45 (45 cm deep) had HDT 12 days. In the second phase of the work experimental consisted of three ponds, which two were fed in single and HDT batch of 8 days (LBT45 and LB245) with its arising tributaries respectively, LT and TE2, and fed continuously with HDT 12 days (LC245), both ponds of the second phase had 45 cm deep. In the first phase, the efficiencies of removals nitrogen overall kjeldahl, nitrogen ammonia and fecal coliforms of pond LC45 were respectively 55%, 71% and 99.3%, higher removals of ponds LC57 (53%, 62% and 99 , 3%), LB57 (39%, 47% and 96.9%) and LB45 (35%, 49% and 97.2%). In the second phase, the ponds with feeding batch and HDT eight days did not differ significantly from the pond with feed continuous and HDT of 12 days, but stood out for the displayed efficiencies, particularly thermotolerant coliforms, in which the pond LBT45 -1 obtained 1E + 03 UFC.100mL meet the WHO requirements for irrigation unrestricted. The ponds fed batch satisfactory results, allowing treat a greater number of tributaries in less time. / Neste trabalho foi avaliado o pós-tratamento do efluente do reator UASB em lagoas de polimento alimentadas com fluxo contínuo e batelada, investigando diferentes profundidades, em duas fases experimentais. Na primeira fase do trabalho, o sistema experimental era constituído de quatro lagoas de polimento, na qual duas foram monitoradas com alimentação contínua (LC57 e LC45) e duas com alimentação semicontínua (LB57 e LB45), sendo seu afluente oriundo da lagoa de transbordo, tanto as lagoas LC57 e LB57 (57 cm de profundidade), quanto às lagoas LC45 e LB45 (45 cm de profundidade) tinham TDH de 12 dias. Na segunda fase o trabalho experimental era constituído por três lagoas, na qual duas eram alimentadas em bateladas e TDH de 8 dias (LBT45 e LB245), com seus afluentes advindos respectivamente, da LT e do TE2, e uma alimentada continuamente com TDH de 12 dias (LC245), ambas as lagoas da segunda fase tinham 45 cm de profundidade. Na primeira fase, as eficiências de remoções de nitrogênio total kjeldahl, nitrogênio amoniacal e coliformes termotolerantes da lagoa LC45 foram, respectivamente de 55%, 71% e 99,3%, superiores as remoções das lagoas LC57 (53%, 62% e 99,3%), LB57 (39%, 47% e 96,9%) e LB45 (35%, 49% e 97,2%). Na segunda fase, as lagoas com alimentação em batelada e TDH de oito dias não diferiram significativamente da lagoa com alimentação contínua e TDH de 12 dias, mas destacaram-se pelas eficiências apresentadas, sobretudo de coliformes termotolerante, no qual a lagoa LBT45 -1 obteve 1E+03 UFC.100mL atendendo as exigências da OMS para irrigação irrestrita. As lagoas alimentadas em batelada obtiveram resultados satisfatórios, permitindo tratar uma quantidade superior de afluentes em menos tempo.
3

Estudo comparativo entre oito sistemas de lagoas de estabilização da região noroeste do Estado de São Paulo / Comparative study of eight systems of stabilization ponds in the northwestern region of São Paulo

João Luiz Cais da Silva Gomes 10 April 2002 (has links)
Este trabalho comparou oito lagoas de estabilização da região Noroeste do Estado de São Paulo, que tratam esgotos predominantemente sanitários de Coroados, Lourdes, Planalto, Zacarias, Alto Alegre, Pongaí, Irapuã e Adolfo, cidades pequenas, com no máximo 5500 habitantes (1700 ligações), onde os quatro primeiros sistemas são compostos apenas por lagoas facultativas primárias e os quatro últimos por lagoas anaeróbias e lagoas facultativas secundárias. Vinte e cinco variáveis físicas, químicas e biológicas foram analisadas em amostras compostas coletadas entre 24/05/2000 e 03/10/2000. A análise da batimetria efetuada fornece indicações de prazos para a remoção do lodo do fundo das lagoas. As taxas de acúmulo de lodo médias obtidas para as lagoas anaeróbias e facultativas primárias foram de 0,07 e 0,14 m3/hab.ano, respectivamente. O pH do efluente das lagoas anaeróbias e das facultativas foi em média 6,6 e 7,4. Nas lagoas anaeróbias observou-se alta remoção de sólidos suspensos e de Demanda Bioquímica de Oxigênio (DBO) com eficiência geral média de 64% e 61% respectivamente. Os sistemas não atenderam plenamente à legislação no tocante a eficiência de remoção de DBO de 80%, porém o valor médio encontrado para os oito sistemas foi de 78%, bastante próximo do exigido. Sugere-se para a região, para eficiência de remoção de DBO de 80%, lagoas anaeróbias com tempo de detenção de 5 dias e para as lagoas facultativas primárias e secundárias tempos de detenção de 25 e 15 dias respectivamente, e taxas de aplicação superficial de 140 e 130 kg DBO/ha.dia, respectivamente. Não foi atingido o limite máximo de 1000 coliformes fecais por 100 ml, obtendo-se média geral de remoção de 97,40% inferindo-se que há necessidade de um processo de tratamento complementar para a remoção de microrganismos. Não observou-se correlação entre eficiência do sistema e relação comprimento/largura das lagoas. Constatou-se maus odores mesmo na ausência de concentrações detectáveis de sulfeto. A remoção média geral de amônio (NH4+), nitrogênio total, fosfato total dissolvido e fósforo total foi de 31%, 12%, 24% e 27% respectivamente nos sistemas estudados. / The present work compared the performance of eight stabilization ponds in the Northwest region of São Paulo state, that treat predominantly the domestic sewage from eight small cities with a maximum of 5000 inhabitants (1700 links): Coroados, Lourdes, Planalto, Zacarias, Alto Alegre, Pongaí, Trapuã and Adolfo. The first four systems are made of four primary facultative ponds and the last four by anaerobic ponds and secondary facultative ponds. A total of twenty-five chemical, physical and biological variables were analyzed in integrated samples collected between 24/05/2000 and 03/10/2000. The bathymetric analysis performed has indicated deadlines for sludge removal from the stabilization pond bottom. Mean sludge accumulation rates o btained for anaerobic and primary facultative ponds were 0.07 and 0.14 m3/inhabt.year, respectively. Effluents from anaerobic and facultative ponds had a mean pH of 6.6 and 7.4. In anaerobic ponds a righ rate of suspended solids removal was found and the Biochemical Oxygen Demand (BOD) had an overall general efficiency of 64% and 61%, respectively. The systems did not completely attend the present legislation in respect to a BOD removal of 80%, as required, however the mean value for the eight systems monitored was 78%, very close to the established limit. It is therefore suggested that for this region, in order to attain the removal efficiency of 80% anaerobic ponds should have a residence time of 5 days and the primary and secondary facultative ones should have residence times of 25 and 15 days respectively, coupled to loading rates of 140 and 170 Kg BOD/ha.day respectively. Also, the maximum limit of 1000 fecal coliforms per 100 ml was not reached, and in general there was a mean removal efficiency of 97.40%, indicating that an additional treatment process needs to be implemented for a successful removal of coliforms. No correlation was found between the removal efficiency and morphometry (length/weight) pond characteristics. Bad smell was present even in the absence of detectable amounts of sulfide. The mean efficiency for the removal of ammonium (NH4+), total nitrogen, total dissolved phosphorus and total phosphorus were 31%, 12%, 24%, and 27% respectively, among the systems studied.

Page generated in 0.0613 seconds