Spelling suggestions: "subject:"residual water treatment"" "subject:"esidual water treatment""
1 |
Mejoramiento de las PTAR de uso minero usando un sistema integrado de clarificación de agua de 3 procesos, mina Coimolache - Cajamarca / Improvement of the WWTP for mining use using an integrated 3-process water clarification system, Coimolache mine - CajamarcaVillalta Yupanqui, Danny Willer, Lévano Lévano, William César 17 November 2021 (has links)
La minería es considerada un motor clave para el desarrollo económico de un país. En este sector, el mejoramiento en la eficiencia de usos del agua es un punto crítico desde el punto de vista económico y ambiental, por ello se siguen implementando nuevos procesos en el tratamiento del agua en el sector minero. Por tal motivo, el objetivo de esta investigación es demostrar que es posible mejorar las PTAR (planta de tratamiento de aguas residuales) de uso minero, lo que implica el mejor funcionamiento del sistema, usando de la mejor forma los recursos que se tienen.
Esta investigación se desarrolló bajo los lineamientos de una metodología experimental, donde se diseñó el coagulador, floculador y clarificador de agua de rastras y el diseño del sistema integrado de clarificación de agua de 3 procesos que lo reemplazaría. El propósito de esto es realizar un análisis comparativo entre ambos sistemas usado en la mina “Coimolache”
Con los resultados de los cálculos realizados para ambos diseños, tanto el clarificador de rastras y el sistema integrado de clarificación de agua de 3 procesos se demostrará que es posible una reducción en área (m2) a ocupar en el terreno, y de volumen (m3) de movimiento de tierra para contribuir la reducción del impacto ambiental. Así mismo, se evaluó la variación de los costos de implementación, operación y mantenimiento.
Finalmente se busca dar a conocer, documentar y demostrar que el uso del sistema integrado de clarificación de agua de 3 procesos tiene múltiples ventajas para promover su implementación al nivel nacional. / Mining is considered a key for the economic development of a country. In this sector, improvement in water use efficiency of use is a critical point from the economic and environmental point of view, is because this reason, new processes are being implemented in the treatment of water in the mining sector. For this reason, the principal objective of this research is to demonstrate that it is possible to optimize the WWTP (wastewater treatment plant) for mining even to get the best operation of the system using in the right way the resources that we have.
This research was developed under the guidelines of an experimental methodology, where coagulator, flocculator, and dredge water clarifier were designed and the design of the integrated 3-process water clarification system that would replace them. The purpose is to realize a comparative analysis between these systems used in the "Coimolache" mine.
With the results of the calculations carried out for both designs, dredge water clarifier and integrated 3-process water clarification system, it will demonstrate that a reduction in area (m2) to be occupied on the ground and volume (m3) of earth movement is possible to contribute to the reduction of environmental impact. Likewise, the variation in implementation, operation and maintenance costs it was evaluated.
Finally, this research intends to make known, document, and demonstrate that the use of the integrated 3-process water clarification system has multiple advantages to promote its implementation at the national level. / Tesis
|
2 |
Comportamento de reator anaeróbio operado em batelada seqüencial, contendo biomassa imobilizada e submetido a aumento progressivo da concentração de substrato de fácil degradação / Behavior of the anaerobic sequencing batch reactor containing immobilized biomass and submitted to a progressive increasing of the concetration of easy degradation substrateMiqueleto, Ana Paula 24 March 2003 (has links)
Os objetivos deste trabalho foram avaliar o desempenho do reator anaeróbio operado em batelada seqüencial quando submetido ao aumento progressivo da concentração de glicose e estimar os parâmetros cinéticos da degradação da glicose. Inicialmente o reator foi operado com ciclos de 8 horas, tratando glicose nas concentrações, aproximadas, de 500, 1000 e 2000 mg/L. Não foi detectada glicose no efluente nas três condições. O reator operou de maneira estável, tratando aproximadamente 500 mg/L de glicose, com eficiência na remoção da DQO filtrada entre 93% e 97%. Na operação com concentrações de glicose no afluente próximas de 1000 mg/L e 2000 mg/L, observou-se instabilidade operacional, principalmente devido à produção de polímeros extracelulares (EPS) que comprometeram a hidrodinâmica e a transferência de massa no sistema. Os valores médios da concentrações de ácidos voláteis no efluente foram de 159 ± 72 mg/L e 374 ± 92 mg/L, respectivamente. Aos perfis de concentração de glicose foi ajustado modelo de primeira ordem, enquanto que um modelo modificado, contemplando concentração residual de matéria orgânica, foi ajustado aos perfis temporais de DQO. Para verificar a formação do EPS, operou-se o reator com 3 horas de ciclo nas concentrações, aproximadas, de 500 e 1000 mg/L. Esta fase teve como objetivo verificar a hipótese, segundo a qual, a produção de EPS seria resultado da exposição da biomassa a baixas concentrações de matéria orgânica por longo período. Dessa forma, reduzindo o tempo de ciclo, a exposição a baixas concentrações também seria reduzida. No entanto, embora o reator tenha operado com relativa estabilidade, verificou-se formação de grande quantidade de EPS logo na primeira condição operacional, com aproximadamente, 500 mg/L de glicose no afluente, indicando que a hipótese não estava correta. / The main objectives of this study were to evaluate the performance of the anaerobic sequencing batch reactor when subjected to a progressive increasing of the influent glucose concentration and estimate the kinetic parameters of glucoses degradation. Initially the reactor was operated with 8-hour cycles, treating glucose at concentrations of 500, 1000 and 2000 mg/L. Glucose was not detected in the effluent in all these three conditions. The reactor showed operating stability treating glucose concentration of approximately 500mg/L, with efficiencies between 93% to 97% in the filtrated COD removal. In the operation with glucose concentrations of 1000 mg/L and 2000 mg/L, approximately, it could be noticed an operational instability, caused mainly by a production of extracellular polymers (EPS) leading to hydrodynamic and mass transfer problems in the reactor. The mean values of volatile acids concentration in the effluent were about 159 ± 72mg/L and 374 ± 92mg/L, respectively. A first order model was adjusted to glucose concentration profiles, and a modified model, including a residual concentration of substrate, was adjusted to COD temporal profiles. To verify the EPS formation, the reactor was operated with 3-hour cycle in the concentrations of 500 and 1000 mg/L This stage had the objective of verifying if the EPS production would result from the exposure of the biomass to low concentration of substrate for a long period of time. Thus, reducing the time cycle, the exposure to low concentrations would also be reduced. Nevertheless, even with the reactor operating with relative stability, the hypotheses could not be verified due the formation of a large amounts of EPS right in the first operational condition with approximately to 500 mg/L of glucose in the influent, showing that the hypothesis was not right.
|
3 |
Comportamento de reator anaeróbio operado em batelada seqüencial, contendo biomassa imobilizada e submetido a aumento progressivo da concentração de substrato de fácil degradação / Behavior of the anaerobic sequencing batch reactor containing immobilized biomass and submitted to a progressive increasing of the concetration of easy degradation substrateAna Paula Miqueleto 24 March 2003 (has links)
Os objetivos deste trabalho foram avaliar o desempenho do reator anaeróbio operado em batelada seqüencial quando submetido ao aumento progressivo da concentração de glicose e estimar os parâmetros cinéticos da degradação da glicose. Inicialmente o reator foi operado com ciclos de 8 horas, tratando glicose nas concentrações, aproximadas, de 500, 1000 e 2000 mg/L. Não foi detectada glicose no efluente nas três condições. O reator operou de maneira estável, tratando aproximadamente 500 mg/L de glicose, com eficiência na remoção da DQO filtrada entre 93% e 97%. Na operação com concentrações de glicose no afluente próximas de 1000 mg/L e 2000 mg/L, observou-se instabilidade operacional, principalmente devido à produção de polímeros extracelulares (EPS) que comprometeram a hidrodinâmica e a transferência de massa no sistema. Os valores médios da concentrações de ácidos voláteis no efluente foram de 159 ± 72 mg/L e 374 ± 92 mg/L, respectivamente. Aos perfis de concentração de glicose foi ajustado modelo de primeira ordem, enquanto que um modelo modificado, contemplando concentração residual de matéria orgânica, foi ajustado aos perfis temporais de DQO. Para verificar a formação do EPS, operou-se o reator com 3 horas de ciclo nas concentrações, aproximadas, de 500 e 1000 mg/L. Esta fase teve como objetivo verificar a hipótese, segundo a qual, a produção de EPS seria resultado da exposição da biomassa a baixas concentrações de matéria orgânica por longo período. Dessa forma, reduzindo o tempo de ciclo, a exposição a baixas concentrações também seria reduzida. No entanto, embora o reator tenha operado com relativa estabilidade, verificou-se formação de grande quantidade de EPS logo na primeira condição operacional, com aproximadamente, 500 mg/L de glicose no afluente, indicando que a hipótese não estava correta. / The main objectives of this study were to evaluate the performance of the anaerobic sequencing batch reactor when subjected to a progressive increasing of the influent glucose concentration and estimate the kinetic parameters of glucoses degradation. Initially the reactor was operated with 8-hour cycles, treating glucose at concentrations of 500, 1000 and 2000 mg/L. Glucose was not detected in the effluent in all these three conditions. The reactor showed operating stability treating glucose concentration of approximately 500mg/L, with efficiencies between 93% to 97% in the filtrated COD removal. In the operation with glucose concentrations of 1000 mg/L and 2000 mg/L, approximately, it could be noticed an operational instability, caused mainly by a production of extracellular polymers (EPS) leading to hydrodynamic and mass transfer problems in the reactor. The mean values of volatile acids concentration in the effluent were about 159 ± 72mg/L and 374 ± 92mg/L, respectively. A first order model was adjusted to glucose concentration profiles, and a modified model, including a residual concentration of substrate, was adjusted to COD temporal profiles. To verify the EPS formation, the reactor was operated with 3-hour cycle in the concentrations of 500 and 1000 mg/L This stage had the objective of verifying if the EPS production would result from the exposure of the biomass to low concentration of substrate for a long period of time. Thus, reducing the time cycle, the exposure to low concentrations would also be reduced. Nevertheless, even with the reactor operating with relative stability, the hypotheses could not be verified due the formation of a large amounts of EPS right in the first operational condition with approximately to 500 mg/L of glucose in the influent, showing that the hypothesis was not right.
|
Page generated in 0.0828 seconds