Controle digital com malha dupla de tensão aplicado a um conversor formador de rede

Souza, Igor Dias Neto de 17 February 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-18T14:49:13Z No. of bitstreams: 1 igordiasnetodesouza.pdf: 13872772 bytes, checksum: 45517d7a6da7ae06ecacec6a7fb7ebd8 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-18T14:50:11Z (GMT) No. of bitstreams: 1 igordiasnetodesouza.pdf: 13872772 bytes, checksum: 45517d7a6da7ae06ecacec6a7fb7ebd8 (MD5) / Made available in DSpace on 2017-04-18T14:50:11Z (GMT). No. of bitstreams: 1 igordiasnetodesouza.pdf: 13872772 bytes, checksum: 45517d7a6da7ae06ecacec6a7fb7ebd8 (MD5) Previous issue date: 2017-02-17 / Esta dissertação apresenta um estudo de um conversor emulador de rede (CER) que faz parte de uma estrutura Power-Hardware-in-the-Loop (PHIL). O PHIL será futuramente utilizado para verificar os impactos causados pela integração de sistemas de geração fotovoltaico (PV) à rede elétrica, assim como a operação do sistema PV frente a distúrbios na rede. O CER, composto por um conversor fonte de tensão (VSC) de dois níveis e filtro de saída LC, é responsável por alimentar cargas isoladas emulando uma rede elétrica. A modelagem do conversor emulador de rede é feita no sistema de coordenadas estacionário (αβ0), fornecendo um sistema de equações diferenciais usado para descrever o comportamento dinâmico do sistema. O conversor é controlado no modo de tensão, através da estratégia de modulação vetorial. Duas malhas de controle em cascata são projetadas. A malha interna utiliza compensadores em avanço digitais para amortecer a ressonância do filtro LC sem a necessidade de uma realimentação interna de corrente. Já a externa utiliza controladores ressonantes digitais modificados para rejeitar distúrbios harmônicos e garantir a qualidade da forma de onda da tensão no ponto de acoplamento comum. Os controladores ressonantes são conectados em série e o projeto é baseado no amortecimento dos zeros. Resultados experimentais, obtidos com o protótipo de laboratório, cujos controladores foram implementados em um processador digital de sinais TMS320F28335 da Texas Instruments, são usados para validar as estratégias de controle propostas. / This dissertation presents a study on a grid-former converter (GFC) which is a part of a Power-Hardware-in-the-Loop (PHIL) structure. The PHIL will be used to verify the impacts caused by the integration of photovoltaic (PV) generation systems into grid, as well as to study the PV operation under grid disturbances. The GFC, composed by a two-level voltage source converter with a LC output filter, is responsible to feed isolated loads emulating an electrical grid. The modeling of the grid-former converter is done in the stationary frame (αβ0), providing a set of differential equations that describes the dynamical behavior of the system. The converter is controlled in voltage mode by means of the space vector modulation (SVM) strategy. Two control loops are designed to control the static converter. At the inner loop a novel discrete-time active damping technique is proposed in order to damp the filter resonance without the need of current feedback. The method is based on an inner feedback loop with digital lead compensator on the feedback path while the external loop uses a discretetime integrator and a modified digital resonant controller to guarantee a decreasing frequency response and ensure the quality of the voltage waveform at the point of common coupling, respectively. The resonant controllers are connected in series and the design is based on its zeros damping. Experimental results obtained with the prototype, which controllers were implemented in a Texas Instruments TMS320F28335 are used to validate the proposed control strategies.
22

Contribuições ao estudo de conexão de sistemas fotovoltaicos à rede elétrica sem filtros passivos: projeto de controladores digitais para redução do conteúdo harmônico

Almeida, Pedro Machado de 29 November 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-24T19:07:44Z No. of bitstreams: 1 pedromachadodealmeida.pdf: 10367147 bytes, checksum: 04b7cf913c75cb9f82395bf7b9769825 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-25T15:25:19Z (GMT) No. of bitstreams: 1 pedromachadodealmeida.pdf: 10367147 bytes, checksum: 04b7cf913c75cb9f82395bf7b9769825 (MD5) / Made available in DSpace on 2017-04-25T15:25:19Z (GMT). No. of bitstreams: 1 pedromachadodealmeida.pdf: 10367147 bytes, checksum: 04b7cf913c75cb9f82395bf7b9769825 (MD5) Previous issue date: 2013-11-29 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A presente tese contribui para a análise, modelagem e projeto de controladores discretos de um sistema de geração fotovoltaico de 30 kWp conectado à rede elétrica sem filtros passivos. O conversor fonte de tensão (VSC) de interface é interligado a rede elétrica usando somente as indutâncias de dispersão de um banco de transformadores monofásicos como filtros harmônicos. Modelos discretos são desenvolvidos tanto para o lado CC quanto para o lado CA do conversor. A modelagem do lado CA foi feita nos sistemas de coordenadas αβ0 e dq0. Já a modelagem da dinâmica do lado CC foi feita no sistema de coordenadas dq de acordo com balanço de potência entre os terminais do VSC. Baseado nos modelos obtidos, duas estratégias básicas foram investigadas e discutidas para projetar os compensadores discretos usados para controlar as correntes sintetizadas por um sistema de geração fotovoltaico no modo de corrente. Resultados experimentais mostram que o uso apenas de controladores lineares, proporcional–integral (PI) e proporcional–ressonante (PR), sintonizados na componente fundamental não é suficiente para manter a qualidade das correntes geradas dentro dos padrões internacionais, devido a operação não linear do transformador de conexão. Para contornar o problema anterior duas soluções foram investigadas: (i) inclusão de múltiplos controladores ressonantes nas coordenadas αβ; e (ii) inclusão de um controlador repetitivo em paralelo com o controlador PI nas coordenadas dq. Resultados experimentais mostraram que ambas estratégias são adequadas para compensar as componentes harmônicas. Finalmente, foi proposta uma estratégia para controlar o conversor durante faltas assimétricas (Fault–ride through) e eliminar as oscilações no barramento CC durante condições de desbalanço. O controlador proposto é composto por uma parcela PI e duas parcelas ressonantes, as quais controlam as componentes média e oscilante, através da injeção correntes de sequencia positiva e negativa na rede, respectivamente. Resultados de simulação mostram que o controlador proposto é adequado para eliminar as oscilações no barramento CC sem prejudicar as estabilidade do sistema. / The current thesis contributes to the analysis, modelling and design of discrete time controllers which aim is to control a 30 kWp photovoltaic dispersed generation system connected to the electric grid without passive filters. In fact, the interface voltage– sourced converter (VSC) is connected to the grid using only the leakage inductance of a single–phase transformer bank as harmonic filters. Initially, discrete time models are developed to the converter’s DC–side as well as to the AC–side. The AC–side modelling is performed on αβ0 and dq0 coordinate systems. On the other hand, the DC–side dynamics are modeled on the dq frame according to the power balance between the converter’s terminals. Based on the models obtained, strategies to control the converter in the current mode control on the αβ and dq are developed and a methodology to design the controllers are addressed in details. Experimental results shown that only the use of linear controllers, proportional–integral (PI) and proportional–resonant (PR), tuned on the fundamental component are not sufficient to guarantee the quality of the generated currents according to international standards. This is due to the operation of the connection transformer in a nonlinear region. In order to overcome this drawback, two solutions are taken into account: (i) inclusion of several parallel resonant controller in αβ frame; and (ii) inclusion of a repetitive controller in parallel with the PI controller in the dq frame. Experimental results shown that both strategies are suitable to compensate the harmonic components on the output current. Finally, a strategy is proposed to control the system under asymmetrical faults (fault–ride through) and to mitigate the voltage oscillation on the DC–side during unbalance conditions. The proposed controller is composed of a PI part and two resonant parts, which controls the average and the oscillating voltage components, through the injection of positive and negative sequence currents into the grid, respectively. Simulation results shown that the proposed controller is suitable to mitigate the DC–side voltage oscillations without jeopardizing the system stability.
23

Projeto e simulação de um filtro híbrido monofásico para correção do fator de potência e compensação harmônica em uma rede industrial

Braga, Mateus Freitas 20 March 2017 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-07-03T11:17:42Z No. of bitstreams: 1 mateusfreitasbraga.pdf: 1732565 bytes, checksum: f8ebb1cc4fe4d9ecbd9cc50ba3eb3f2a (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-07T21:17:21Z (GMT) No. of bitstreams: 1 mateusfreitasbraga.pdf: 1732565 bytes, checksum: f8ebb1cc4fe4d9ecbd9cc50ba3eb3f2a (MD5) / Made available in DSpace on 2017-08-07T21:17:21Z (GMT). No. of bitstreams: 1 mateusfreitasbraga.pdf: 1732565 bytes, checksum: f8ebb1cc4fe4d9ecbd9cc50ba3eb3f2a (MD5) Previous issue date: 2017-03-20 / Cresce a cada dia o n úmero de cargas não lineares conectadas aos diversos sistemas el étricos, seja em ní vel de transmissão ou distribui ção. Como consequência desse crescimento, e possí vel encontrar casos de consumidores enfrentando problemas relacionados a desarmes de disjuntores e sobreaquecimento de condutores, entre outros efeitos indesejados. Tomando um desses casos como base para este estudo, esta disserta ção tem o objetivo de avaliar e propor uma solu ção para uma rede monof asica real, que possivelmente e comum a outros consumidores. A carga monof ásica composta por lumin árias a LED (t picas cargas não lineares) e cargas indutivas se apresenta aos terminais da fonte com um comportamento de elevado conte udo harmônico (THD) de corrente e baixo fator de potência. Essa condi ção adversa pode ser mitigada de diversas maneiras, como por exemplo pela a ção de um fi ltro passivo,fi ltro ativo ou ainda fi ltro h brido (o qual e composto por uma combina ção dos dois primeiros). Ser a proposto nesta disserta ção uma metodologia de projeto relacionada a aplica ção de um fi ltro hi brido monof ásico visando corrigir o fator de potência e reduzir o conte udo harmônico de corrente presente na fonte, tomando como base as caracterí sticas do sistema avaliado em uma ind ústria gr áfi ca t ípica. Serão investigadas algumas con gura ções de filtros com o objetivo de mitigar problemas de Qualidade de Energia El étrica. Como consequência, ser a desenvolvida a an álise matem atica da topologia adotada e o projeto do controlador, baseado em um controlador proporcional-ressonante e na Teoria p-q Monof asica. A veri ca ção da solu ção proposta e sustentada pelos resultados de simula ção obtidos via software PSIM. / The amount of non-linear loads connected to the various electrical systems grows on a daily basis, regardless those loads are tied to a transmission or distribution bar. As a consequence of this growth, it is possible to nd cases of consumers facing problems such as tripping of breakers and cables overheating, among other undesired e ects. Taking one of these cases as the focus of this study, this dissertation aims to evaluate and propose a solution to a real single-phase system, which could be considered similar to other consumers. The single-phase load composed of LED luminaires (typical non-linear load) and inductive loads presents high THD and low power factor behavior at source terminals. This condition can be mitigated by using some well-known techniques, such as passive lters, active lters or hybrid lters, (which are composed by the combination of the former two). This Master document Thesis proposes a design methodology of a single-phase hybrid lter aiming power factor correction and reduction of the harmonic content of the current delivered by the AC power supply when feeding a typical printing factory. It will be reviewed and discussed some possible lter con gurations aimed to solve the case under evaluation. It is also included the mathematical analysis of the proposed topology, along with the design of the control system of the inverter. The Single-Phase p-q Theory is reviewed in order to design the control. The closed-loop control is desinged by a proportional-resonant compensator. Simulation results, by employing the PSIM software, are provided aiming to validate the solution proposed.
24

Controle de potência do gerador de relutância variável de 12/8 utilizando o controlador fuzzy pi auto-ajustável

Ccantuta Chirapo, Karlos Alexander January 2018 (has links)
Orientador: Prof. Dr. José Luis Azcue Puma / Coorientador: Prof. Dr. José Alberto Torrico Altuna / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, Santo André, 2018. / Este trabalho apresenta o controle de potência do gerador de relutância variável de 12/8 utilizando o controlador Fuzzy PI auto-ajustável e o controlador P+ressonante para o conversor conectado à rede elétrica. Inicialmente são estudados os princípios de operação da máquina e a topologia do conversor eletrônico de potência. Usando o software de simulação Matlab/Simulink é implementado o modelo da máquina de relutância variável utilizando as curvas características de corrente e de torque. Com o objetivo de controlar a potência gerada pela máquina e utilizando seu modelo matemático dinâmico projeta-se o controlador PI, e implementa-se o controlador Fuzzy PI auto-ajustável para atingir o mesmo objetivo. Assim, projeta-se também um controlador PI para o controle da tensão CC além de um controlador P+ressonante com o objetivo de melhorar a resposta em regime permanente da potência injetada na rede elétrica. Para este propósito é utilizado um conversor monofásico de dois níveis. Os resultados das simulações mostram o bom desempenho do sistema proposto e o controlador de potência é validado também através de resultados experimentais. / This work presents the power control of the 12/8 variable reluctance generator using Fuzzy self-tuning PI controller and the P+resonant controller for the converter connected to the electric network. Initially are studied the principles of operation of the machine and power electronic converter topology. Using the Matlab/Simulink simulation software is implemented the model of switched reluctance machine using the current and its torque characteristic curves. With the purpose of controlling the power generated by the machine and using his dynamic mathematical model is designed the PI controller, and the Fuzzy self-tuning PI controller is implemented to achieve the same objective. So, also is designed a PI controller for control of the link DC, in addition to the P+resonant controller with the objective of improving the response to its steady state of the injected power into the electric network. For this purpose it is used a single-phase two-level converter. The results of the simulations show the good performance of the proposed system and the power controller is validated by experimental results.