The Persistence of Retro-commissioning Savings in Ten University Buildings

Toole, Cory Dawson 2010 May 1900 (has links)
This study evaluated how well energy savings persisted over time in ten university buildings that had undergone retro-commissioning in 1996. The savings achieved immediately following retro-commissioning and in three subsequent years were documented in a previous study (Cho 2002). The current study expanded on this previous study by evaluating the performance of each building over nine additional years. Follow up retro-commissioning work performed in each building during that time was documented, as well as changes to the energy management control system. Savings were determined in accordance with the methodology outlined in the International Performance Measurement and Verification Protocol (IPMVP 2007), with ASHRAE Guideline 14 also serving as a reference. Total annualized savings for all buildings in 1997 (the year just after retro-commissioning) were 45(plus or minus 2)% for chilled water, 67(plus or minue 2)% for hot water, and 12% for electricity. Combining consumption from the most recent year for each building with valid energy consumption data showed a total savings of 39(plus or minus 1)% for chilled water, 64(plus or minus 2)% for heating water, and 22% for electricity. Uncertainty values were calculated in accordance with methodology in the IPMVP and ASHRAE Guideline 14, and were reported at the 90% confidence interval. The most recent year of data for most of the buildings was 2008-2009, although a few of the buildings did not have valid consumption data for that year. Follow up work performed in the buildings, lighting retrofits, and building metering changes beginning in 2005 were the major issues believed to have contributed to the high level of savings persistence in later years. When persistence trends were evaluated with adjustment for these factors, average savings for the buildings studied were found to degrade over time, and exponential models were developed to describe this degradation. The study concluded that on average energy savings after retro-commissioning will degrade over time in a way that can be modeled exponentially. It was also concluded that high levels of savings persistence can be achieved through performing retro-commissioning follow up, particularly when significant increases are observed in metered energy consumption data, but also at other times as retro-commissioning procedures and technology continually improve.
2

Optimal Investment Strategy for Energy Performance Improvements in Existing Buildings

Ramkrishnan, Karthik 15 November 2007 (has links)
Current global efforts for energy conservation and optimization are focused on improvements in energy supply and production systems, and on encouraging the adoption of energy-efficient devices and equipment. However, systematic assessments of economic and technical implications when adopting energy-efficient alternative systems in buildings have not yet been explored thoroughly. The uncertainty about the consequences of investing in alternative energy-efficient systems has led to a prolonged utilization of obsolete building systems (underperforming HVAC systems, inefficient lighting systems, badly maintained and equipment, and so forth). This has led to overall poor energy efficiency, creating considerable burden on the building operation budget. This research discusses the procedure for formulating an investment strategy to improve existing building energy performance. The approach is suitable for large building portfolios where a plethora of potential refurbishment interventions can be considered. This makes our approach especially suited for use on university campuses and most of this report will focus on that particular application utilization protocols especially for use on campuses. This investment model only looks at the energy related savings versus investments; it is well understood that the ultimate selection of the optimal set of improvement options of a portfolio will be determined by additional considerations, such as overall value, occupant satisfaction, productivity improvements, aesthetics, etc. Nevertheless, many campus managers are confronted with the question how much energy they can save with a given investment amount. This is exactly what our approach helps to answer. The investment optimization strategy is implemented in software "InvEnergy," which systematically calculates the costs and benefits of all possible building-technology pairings, taking uncertainties in the saving/investment calculations and estimates into account. This tool empowers decision makers in facility management to make complex investment decisions during continuous building commissioning.