• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise física química e mecânica de um cimento experimental à base de MTA /

Massi, Santiago. January 2010 (has links)
Orientador: Mário Tanomaru Filho / Banca: José Milton Carlos Kuga / Banca: Marco Antonio Hungaro Duarte / Resumo: Modificações têm sido propostas ao MTA e cimento Portland para a obtenção de um cimento obturador de canal radicular. Um material experimental à base de MTA (CE-MTA) é avaliado neste estudo para emprego como cimento endodôntico, contendo cimento Portland, radiopacificador, aditivos e veículo. Assim, o objetivo deste estudo foi avaliar o cimento experimental, usando como parâmetros comparativos o cimento AHPlus (AHP), MTA-Angelus (MTA) e cimento Portland (CP). Foram realizados testes de tempo de presa; resistência à compressão; escoamento; radiopacidade; alteração do pH e liberação de íons cálcio. Todas as metodologias foram definidas usando como referência normas ISO e a literatura científica recente da área endodôntica. O teste de escoamento seguiu a metodologia proposta pela norma ISO, com a medição do diâmetro dos discos de cimento, assim como da área por meio de um programa de imagens. O tempo de presa foi avaliado pela norma da ADA/ASTM, verificando os períodos de tempo necessários para que as agulhas indentadoras (100g e 2mm de diâmetro na ponta; e 456g e 1 mm de diâmetro na ponta) não marcassem a superfície dos discos de cimento, fornecendo resultados para a presa inicial e final. No teste de radiopacidade foi feita uma comparação da radiopacidade de discos de cimento de 10mm de diâmetro e 1 mm de espessura, com uma escala de alumínio padronizada. A alteração de pH do foi avaliada com um pHmetro e a liberação de cálcio com um espectrofotômetro de absorção atômica. Para ambos os ensaios tubos preenchidos com o cimento foram imersos em frascos contendo água destilada. Os tubos foram passados para um novo frasco contendo mais água destilada nos períodos de tempo de 3, 6, 12, 24 e 48 horas, assim como 7, 14 e 28 dias. O líquido remanescente nos frascos foi avaliado para obter os resultados deste ensaio. Na resistência à compressão... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Modifications of MTA and Portland cement has been proposed to obtain an root canal sealer. This study evaluates an experimental MTA based root canal sealer (CE-MTA) which contains Portland cement, radiopacifier, addictives and a vehicle. The aim of this study was to evaluate the experimental endodontic sealer, using white Portland cement (CP), MTAAngelus(MTA) and AH Plus (AHP) as control groups. The tests realized were: setting time, radipacity, compressive strength, pH alterations, calcium release and flow. The flow test followed the ISO 6876 norms, and the the sealer discs' area was measured with a paquimeter and using an area measurement software. The setting time was measured based on the ADA/ASTM Norm, allowing initial and final setting time measurements. Radiopacity was measured using an aluminum scale as reference and sealer discs with 10 mm in diameter by 1 mm thick. The pH was measured using a pHmeter and the calcium release using an atomic absorption spectrophotometer. For compressive strength test the ISO 9917 methodology was used, testing specimens at 24 hours and 21 days. All the data was submitted to statistical analysis, a normality test, and after the data normality check, an ANOVA and a Tukey test using 5% significance were applyed. Results: The results showed that CE-MTA has flow similar to AH Plus and superior to the minimum required by the ISO standard. The setting time was faster than AH Plus and slower than MTA and Portland cement. The compressive strength was lower for the experimental sealer at 24 hours time compared with all the tested materials, and similar for the experimental sealer and MTA at 21 days. The experimental sealer had a superior calcium release in all period of time, and higher pH values until 48 hours period, being similar to MTA and Portland cement on posterior time periods. The experimental sealer radiopacity was lower... (Complete abstract click electronic access below) / Mestre
2

Avaliação "in vitro" de três diferentes técnicas de instrumentação quanto ao deslocamento do canal radicular /

Zanin, Fernando Perosa. January 2006 (has links)
Orientador: Renato de Toledo Leonardo / Banca: Idomeo Bonetti Filho / Banca: Celso Kenji Nishiyama / Resumo: Foram avaliadas comparativamente três técnicas híbridas automatizadas de preparo de canais radiculares, Free Tip, Endo-Eze Híbrida e Race. Neste trabalho, foram utilizados 24 pré-molares artificiais, confeccionados em resina, com canais radiculares únicos, com curvatura de quarenta graus e raio de quatro milímetros. Para a avaliação dos preparos dos canais radiculares, os dentes foram divididos em três grupos e seccionados no terço apical das raízes. As secções das raízes foram então captadas antes e após a instrumentação de forma padronizada e as imagens transferidas para o computador que procedeu às analises comparativas. A avaliação baseou-se na extensão do deslocamento e na direção do movimento do centro do canal radicular. Apesar de a técnica Endo-Eze Híbrida ter apresentado um menor deslocamento do centro do canal radicular do que as técnicas Free Tip e Race, não houve diferença estatisticamente significante entre as técnicas estudadas. / Abstract: Three different techniques of automated instrumentation of root canal preparation were evaluated, Free tip, Hybrid Endo-Eze and Race. Twenty four single rooted artificial resin pre-molars were manufactured whith an apical curvature of 40-degree angle and 4 millimeters of radius each. For the evaluation of root canal preparation, the artificial teeth were divided in three groups and sectioned at the apical third. The sections were taken before and after the instrumentation on a standardize way and the images obtained were transferred to a computer for comparative analysis. The evaluation was based on the extension of canal displacement and the direction of the canal center movement. Although the Hybrid Endo-Eze technique had presented a smaller deviation of root canal center than Free Tip and Race techniques, there was no statistical difference between the analysed techniques. / Doutor
3

Avaliação da instrumentação rotatória com limas de níquel e titânio, K3 e RaCe, em canais radiculares curvos simulados /

Leonardi, Denise Piotto. January 2004 (has links)
Orientador: Roberto Miranda Esberard / Banca: Renato de Toledo Leonardo / Banca: Giulio Gavini / Resumo: Foram analisadas, comparativamente, a ação e a presença de deformações proporcionadas pela instrumentação com limas manuais Flexofile e dois Sistemas Rotatórios de Limas Endodônticas de Níquel e Titânio: o Sistema K3 (SDS Kerr) e o Sistema Race (FKG), sobre as paredes dos canais radiculares curvos simulados em blocos de resina. Foram utilizadasa as técnicas manual e ultra-sônica de irrigação. Após a instrumentação, os blocos de resina foram digitalizados, analisados e estabelecido escores de acordo com a qualidade do preparo biomecânico obtido em cada uma das técnicas. Concluímos que os melhores resultados foram obtidos com as duas técnicas de instrumentação rotatória associadas à irrigação manual. / Abstract: It were comparatively analyzed the action and aberrations provided by the instrumentation using manual files Flexofile and two Rotary Systems of Endodontic Nickel-Titanium files, the K3 (SDS Kerr) System and the Race (FKG) System, in the curved root canal walls simulated in resin blocks, with two irrigations techniques: a manual and an ultrasonic technique. Thereafter the instrumentation, the resin blocks were digitalized, analysed and scores were set according to the preparation's quality achieved in each technique. It was ended that the best results were obtained with the two techniques of rotary instrumentation associated to the manual irrigation. / Mestre
4

Avaliação da eficácia das instrumentações rotatórias (Sistema Quantec LX, Pow-R, Profile e Profile Série 29) em canais radiculares curvos simulados /

Camargo, Maurício. January 2000 (has links)
Orientador: Roberto Miranda Esberard / Banca: Renato de Toledo Leonardo / Banca: Giulio Gavini / Resumo: Foram avaliadas comparativamente as técnicas Quantec LX, Pow-R, Profile e Profile série 29, em blocos de resina com canais radiculares simulados, as deformações produzidas nas paredes côncavas e convexas, através da editoração de imagens com a utilização do programa AutoCAD. Os resultados nos permitiram concluir que o sistema que mais provocou a ampliação foi o sistema Quantec LX seguido respectivamente pelo sistema Profile série 29, sistema Profile e sistema Pow-R. Permitiu também fazer uma análise matemática de qual a quantidade e local do desgaste nos níveis 1, 3, 5, 7, 12 e 16 milímetros. / Abstract: It was comparatively evaluated the Quantec LX, Pow-R, Profile and Profile series 29 techniques, utilizing resin blocks, with simulated canals. The evaluation was done with the AutoCAD program after image editoration. The results led us to conclude that, the Quantec LX system promoted the greater amplification of the root canal, folowed by Profile series 29, Profile and Pow-R systems. This kind of analysis, alowed us to concluse also, where and the quantity of wear in different levels. / Mestre
5

Estudo comparativo do preparo do canal radicular de dentes artificiais utilizando diferentes técnicas automatizadas de instrumentação /

Camargo, Maurício. January 2004 (has links)
Orientador: Renato de Toledo Leonardo / Banca: Idomeo Bonetti Filho / Banca: Roberto Miranda Esberard / Banca: Manoel Eduardo de Lima Machado / Banca: Carlos Alberto Ferreira Murgel / Resumo: Foram avaliados comparativamente três sistemas de técnicas automatizadas de preparo dos canais radiculares, Endo-Eze, K3 e Race. Neste trabalho, foram utilizados 30 pré-molares artificiais, confeccionados em resina, com canais radiculares únicos, com curvatura de quarenta graus. Para a avaliação do preparo dos canais radiculares, os dentes foram divididos em três grupos, incluídos em blocos de resina e seccionados no terço apical das raízes. As secções das raízes foram fotografadas antes e após a instrumentação de forma padronizada e as imagens transferidas para o computador que procedeu às análises comparativas. A avaliação baseou-se na extensão do deslocamento, na direção do movimento do centro do canal radicular e na área desgastada. Em relação ao preparo dos canais, os sistemas Endo-Eze e K3, apresentaram um deslocamento do centro do canal radicular maior do que o sistema Race. Menores valores de desgaste foram observados para o sistema Race, seguido dos sistemas K3 e Endo-Eze. Os dentes utilizados neste estudo mostraram-se eficazes na avaliação de diferentes técnicas de instrumentação. / Abstract: Three different systems of automated instrumentation techniques of root canal preparation were evaluated, Endo-Eze, K3 and Race. Thirty single rooted artificial resin pre-molars were manufacture with an apical curvature of 40-degree angle each. For the evaluation of the root canal preparation, the artificial teeth were divide in three groups, included in resin blocks and sectioned at the apical third. The sections were photographed before and after the instrumentation on a standardize way and the images obtained were transferred to a computer for the comparative analysis. The evaluation was based on the extension of canal displacement, the direction of the canal center movement and at the removed area. Concerning the root canal preparations, the Endo-Eze and K3 systems presented a bigger deviation of the center of the original root canal bigger them the Race system. Lower values for the Race system were observed fallowed by the K3 and Endo-Eze. The artificial teeth utilized in this study were efficient for the evaluation of different automated instrumentation techniques. / Doutor

Page generated in 0.1101 seconds