• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Experimental investigations and finite element analyses of interface heat partition in a friction brake system. New modelling paradigm for describing friction brake systems to support studies of interface temperature, contact pressure, heat flux distribution and heat partition ratio by experiment and FE simulation

Qui, Le January 2018 (has links)
Operating temperature range is one of the primary design considerations for developing effective disc brake system performance. Very high braking temperatures can introduce effects detrimental to performance such as brake fade, premature wear, brake fluid vaporization, bearing failure, thermal cracks, and thermally-excited vibration [2]. This project is concerned with investigating deficiencies and proposing improvements in brake system Finite Element (FE) models in order to provide high quality descriptions of thermal behaviour during braking events. The work focuses on brake disc/pad models and the degree of rotational freedom allowed for the pad. Conventional models [10] allow no motion/or free motion of the pad. The present work investigates the effect on disc/pad interface temperature and pressure distributions of limited relaxations of this rotational restriction. Models are proposed, developed and validated that facilitate different rotational degrees of freedom (DoF) of the pad. An important influencing factor in friction brake performance is the development of an interface tribo-layer (ITL). It is reasonable to assume that allowing limited rotational motion of the pad will impact the development of the ITL (e.g. due to different friction force distributions) and hence influence temperature. Here the ITL is modelled in the numerical simulations as a function of its thickness distribution and thermal conductivity. Different levels of ITL thermal conductivity are defined in this work and results show that conductivity significantly a1qwffects interface temperature and heat partition ratio. The work is based around a set of test-rig experiments and FE model developments and simulations. For the experimental work, a small-scale test rig is used to investigate the friction induced bending moment effect on the pad/disc temperature. Significant non-uniform wear is observed across the friction surface of the pad, and reasons for the different wear rates are proposed and analyzed together with their effect on surface temperature. Following on from experiment a suite of models is developed in order to evidence the importance of limited pad motion and ITL behaviours. A 2D coupled temperature-displacement FE model is used to quantify the influence of different pad rotational degrees of freedom and so provide evidence for proposing realistic pad boundary settings for 3D models. Normal and high interface thermal conductance is used in 2D models and results show that the ITL thermal conductivity is an important factor influencing the maximum temperature of contact surfaces and therefore brake performance. The interface heat partition ratio is calculated by using the heat flux results and it is confirmed that this value is neither constant nor uniform across the interface surfaces. Key conclusions from the work are (i) that ITL thermal conductivity is an important factor influencing the interface temperature/heat flux distribution and their maximum values, (ii) that allowed motion of the pad significantly affects the interface pressure distribution and subsequently the temperature distribution, (iii) that the transient heat partition in friction braking is clearly quite different to the conventional friction-pair steady heat partition (the heat partition ratio is not uniformly distributed along the interface) and (iv) that the thickness of the ITL increases through braking events, reducing the heat transfer to the disc, and so providing a possible explanation for increasing pad temperature observed over the life time of a brake pad.
2

Análise da liberdade rotacional de pilares para prótese unitária de hexágono externo submetidos à ciclagem mecânica / Evaluation of abutment rotational freedom of external hexagon single implat restoration after mechanical cycling

Piantino, Marcela Caffarena Junqueira 30 August 2010 (has links)
A estabilidade da prótese na junção parafusada está diretamente relacionada ao seu grau de adaptação e assentamento bem como à pré-carga que é gerada para unir os componentes. O afrouxamento e/ ou fratura do parafuso do pilar e também a desadaptação rotacional na interface implante/ pilar têm sido relatados como os maiores problemas encontrados em reabilitações unitárias parafusadas, em especial áreas de pré-molares e molares. Desta forma, o objetivo deste estudo foi avaliar a liberdade rotacional (LR) de 20 pilares protéticos tipo UCLA calcináveis (10 totalmente plásticos e 10 com a base usinada em Tilite - Neodent Implante Osteointegrável), fundidos em liga de NiCr e Tilite, respectivamente, sobre 10 implantes de hexágono externo (Hexágono Externo, HE Neodent Implante Osteointegrável) para próteses unitárias e, também o torque de afrouxamento do parafuso do pilar, submetidos à ciclagem mecânica. Um dispositivo foi fabricado para medir os ângulos de liberdade rotacional entre os hexágonos de implante e pilar em três diferentes tempos: antes e após o processo de fundição e depois da ciclagem mecânica. Os grupos foram classificados de acordo com as leituras de LR: (1) pilares novos + implantes novos; (2) pilares fundidos + implantes novos; (3) pilares fundidos + implantes, ambos ciclados; (4) outros pilares novos + implantes ciclados e (5) os mesmos pilares após fundição + implantes ciclados. Foram medidas as distâncias entre os lados e vértices do hexágono externo dos implantes e interno dos pilares. Para a realização da ciclagem mecânica, foi utilizada uma máquina de ensaio cuja carga média aplicada foi de 120 N em sentido axial, com componente oblíquo, a uma freqüência de 101 ciclos por minuto (1,8 Hz), durante 500.000 ciclos. O torque de aperto dos parafusos de fixação foi de 32 N.cm e o de afrouxamento mensurado após fadiga. Atestada a normalidade da amostra aplicou-se o teste t de Student para comparações em par (p<0,05). Os resultados encontrados foram: para LR (em graus): Grupo Tilite (1) 2,930 ± 0,273; (2) 4,506 ± 2,448; (3) 5,126 ± 2,885; (4) 3,229 ± 0,235; (5) 2,813 ± 0,406; Grupo NiCr: (1) 4,684 ± 0,788; (2) 3,21 ± 1,370; (3) 3,818 ± 1,904; (4) 6,029 ± 0,503; (5) 4,421 ± 2,499. A análise estatística revelou que não houve significância entre nenhuma das diferentes leituras de LR tanto para os pilares do grupo NiCr quanto para os do Tilite; todavia, quando a comparação foi feita entre os pilares, houve diferença estatística significativa para as leituras (1) e (4), com maiores valores para os pilares plásticos calcináveis. O destorque para o grupo NiCr foi de 13,26 ± 4,32 N.cm com perda de torque de 41,44% e, para o grupo Tilite de 13,72 ± 7,36 N.cm e perda de torque de 42,88%. Houve expressiva perda de torque para ambos os grupos, porém não houve diferença estatística na comparação entre as ligas. A quantidade de ciclos aplicada não foi suficiente para alterar de forma significativa a LR nos conjuntos implante/ pilar quando avaliados para cada tipo de liga. A aplicação de cargas cíclicas alterou de forma significativa as dimensões dos implantes. / Prosthesis stability is related to misfit and screw joint preload. The screw loosening or fracture and rotational misfit have been related as the major problems in screwed single implant restorations, especially in molar or premolar areas. The aim of this study was to evaluate the rotational freedom and detorque of 20 UCLA type abutment (10 plastic and 10 machined abutments) cast in NiCr and NiCrTi alloys respectively, over 10 external hexagon implants submitted to mechanical cycling. A device was made to measure the rotational freedom between the implant hexagon and abutment in three different times: before and after the cast procedure and after the mechanical cycling. Groups were classified according the rotational misfit register: (1) new abutments + new implants; (2) cast abutments + new implants; (3) cycled cast abutments + cycled implants; (4) new abutments + cycled implants, and, (5) cast abutments + cycled implants. Measurements were made in the sides and vertices of external hexagon of the implants and internal hexagon of the abutments. Specimens were positioned with 30° of inclination in relation to the vertical axis in an eletromechanical machine for mechanical cycling (5.0x105 cycles) using 120N axial load and 1.8 Hz of frequence. The abutment screws were tightened to a torque of 32N.cm and the detorque measurement was registered after mechanical cycling. The rotational freedom results were: NiCrTi groups - (1) 2.930 ± 0.273; (2) 4.506 ± 2.448; (3) 5.126 ± 2.885; (4) 3.229 ± 0.235; (5) 2.813 ± 0.406; and NiCr groups - (1) 4.684 ± 0.788; (2) 3.21 ± 1.370; (3) 3.818 ± 1.904; (4) 6.029 ± 0.503; (5) 4.421 ± 2.499. Statistical analysis (p<0.05) showed that there is not significance among the different rotational freedom of NiCrTi or NiCr abutments; but there is statistically significant difference between (1) and (4) with higher values to the plastic abutments. Detorque of NiCr group was 13.26±4.32N.cm (-41.44%) and to the NiCrTi group was 13.72±7.36N.cm (-42.88%) but there is not statistically significant difference between the alloys. The mechanical cycling did not statistically influence the rotational freedom in the abutment/implant system when evaluated to each alloy but influenced the implant dimension.
3

Análise da liberdade rotacional de pilares para prótese unitária de hexágono externo submetidos à ciclagem mecânica / Evaluation of abutment rotational freedom of external hexagon single implat restoration after mechanical cycling

Marcela Caffarena Junqueira Piantino 30 August 2010 (has links)
A estabilidade da prótese na junção parafusada está diretamente relacionada ao seu grau de adaptação e assentamento bem como à pré-carga que é gerada para unir os componentes. O afrouxamento e/ ou fratura do parafuso do pilar e também a desadaptação rotacional na interface implante/ pilar têm sido relatados como os maiores problemas encontrados em reabilitações unitárias parafusadas, em especial áreas de pré-molares e molares. Desta forma, o objetivo deste estudo foi avaliar a liberdade rotacional (LR) de 20 pilares protéticos tipo UCLA calcináveis (10 totalmente plásticos e 10 com a base usinada em Tilite - Neodent Implante Osteointegrável), fundidos em liga de NiCr e Tilite, respectivamente, sobre 10 implantes de hexágono externo (Hexágono Externo, HE Neodent Implante Osteointegrável) para próteses unitárias e, também o torque de afrouxamento do parafuso do pilar, submetidos à ciclagem mecânica. Um dispositivo foi fabricado para medir os ângulos de liberdade rotacional entre os hexágonos de implante e pilar em três diferentes tempos: antes e após o processo de fundição e depois da ciclagem mecânica. Os grupos foram classificados de acordo com as leituras de LR: (1) pilares novos + implantes novos; (2) pilares fundidos + implantes novos; (3) pilares fundidos + implantes, ambos ciclados; (4) outros pilares novos + implantes ciclados e (5) os mesmos pilares após fundição + implantes ciclados. Foram medidas as distâncias entre os lados e vértices do hexágono externo dos implantes e interno dos pilares. Para a realização da ciclagem mecânica, foi utilizada uma máquina de ensaio cuja carga média aplicada foi de 120 N em sentido axial, com componente oblíquo, a uma freqüência de 101 ciclos por minuto (1,8 Hz), durante 500.000 ciclos. O torque de aperto dos parafusos de fixação foi de 32 N.cm e o de afrouxamento mensurado após fadiga. Atestada a normalidade da amostra aplicou-se o teste t de Student para comparações em par (p<0,05). Os resultados encontrados foram: para LR (em graus): Grupo Tilite (1) 2,930 ± 0,273; (2) 4,506 ± 2,448; (3) 5,126 ± 2,885; (4) 3,229 ± 0,235; (5) 2,813 ± 0,406; Grupo NiCr: (1) 4,684 ± 0,788; (2) 3,21 ± 1,370; (3) 3,818 ± 1,904; (4) 6,029 ± 0,503; (5) 4,421 ± 2,499. A análise estatística revelou que não houve significância entre nenhuma das diferentes leituras de LR tanto para os pilares do grupo NiCr quanto para os do Tilite; todavia, quando a comparação foi feita entre os pilares, houve diferença estatística significativa para as leituras (1) e (4), com maiores valores para os pilares plásticos calcináveis. O destorque para o grupo NiCr foi de 13,26 ± 4,32 N.cm com perda de torque de 41,44% e, para o grupo Tilite de 13,72 ± 7,36 N.cm e perda de torque de 42,88%. Houve expressiva perda de torque para ambos os grupos, porém não houve diferença estatística na comparação entre as ligas. A quantidade de ciclos aplicada não foi suficiente para alterar de forma significativa a LR nos conjuntos implante/ pilar quando avaliados para cada tipo de liga. A aplicação de cargas cíclicas alterou de forma significativa as dimensões dos implantes. / Prosthesis stability is related to misfit and screw joint preload. The screw loosening or fracture and rotational misfit have been related as the major problems in screwed single implant restorations, especially in molar or premolar areas. The aim of this study was to evaluate the rotational freedom and detorque of 20 UCLA type abutment (10 plastic and 10 machined abutments) cast in NiCr and NiCrTi alloys respectively, over 10 external hexagon implants submitted to mechanical cycling. A device was made to measure the rotational freedom between the implant hexagon and abutment in three different times: before and after the cast procedure and after the mechanical cycling. Groups were classified according the rotational misfit register: (1) new abutments + new implants; (2) cast abutments + new implants; (3) cycled cast abutments + cycled implants; (4) new abutments + cycled implants, and, (5) cast abutments + cycled implants. Measurements were made in the sides and vertices of external hexagon of the implants and internal hexagon of the abutments. Specimens were positioned with 30° of inclination in relation to the vertical axis in an eletromechanical machine for mechanical cycling (5.0x105 cycles) using 120N axial load and 1.8 Hz of frequence. The abutment screws were tightened to a torque of 32N.cm and the detorque measurement was registered after mechanical cycling. The rotational freedom results were: NiCrTi groups - (1) 2.930 ± 0.273; (2) 4.506 ± 2.448; (3) 5.126 ± 2.885; (4) 3.229 ± 0.235; (5) 2.813 ± 0.406; and NiCr groups - (1) 4.684 ± 0.788; (2) 3.21 ± 1.370; (3) 3.818 ± 1.904; (4) 6.029 ± 0.503; (5) 4.421 ± 2.499. Statistical analysis (p<0.05) showed that there is not significance among the different rotational freedom of NiCrTi or NiCr abutments; but there is statistically significant difference between (1) and (4) with higher values to the plastic abutments. Detorque of NiCr group was 13.26±4.32N.cm (-41.44%) and to the NiCrTi group was 13.72±7.36N.cm (-42.88%) but there is not statistically significant difference between the alloys. The mechanical cycling did not statistically influence the rotational freedom in the abutment/implant system when evaluated to each alloy but influenced the implant dimension.

Page generated in 0.1023 seconds